{"title":"Honeywell C300","description":"\u003cp\u003eKontroler Honeywell C300 to serce platformy Experion PKS. Posiadamy szeroki asortyment modułów I\/O serii C oraz zasilaczy zaprojektowanych do zastosowań procesowych o dużej gęstości. Nasz magazyn obejmuje najnowsze wersje sprzętowe, aby zapewnić bezproblemową integrację z Twoim istniejącym środowiskiem Experion.\u003c\/p\u003e","products":[{"product_id":"cc-taix61-51307077-175-honeywell-experion-analog-input","title":"CC-TAIX61 51307077-175 Honeywell Experion Analog Input","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #007bff;\"\u003eHoneywell CC-TAIX61 51307077-175\u003c\/strong\u003e performs as a high-integrity 8-channel Analog Input Field Termination Assembly (IOTA) optimized for the Experion Process Knowledge System (PKS) C300 controller platform. This module converts field-side instrumentation signals directly into precise process variables. It delivers efficient, deterministic data transmission for real-time monitoring and exact loop feedback across hazardous process environments.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technological Advantages\u003c\/h2\u003e\n\u003ch3\u003eVersatile Signal Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module hardware adapts natively to multiple field interfaces, reading both 0-10 V DC voltage loops and 4-20 mA current loops across 8 independent channels without requiring external signal converters.\u003c\/p\u003e\n\n\u003ch3\u003eAdvanced Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eIntegrated hardware filtering conditions incoming data streams and eliminates high-frequency line noise, ensuring smooth, highly reliable process metrics are transmitted directly to the C300 controller core.\u003c\/p\u003e\n\n\u003ch3\u003eIndustrial Grade Power Efficiency\u003c\/h3\u003e\n\u003cp\u003eThe engineered circuitry runs reliably on a standard 24 V DC supply while drawing a tight power envelope limited to a maximum consumption of 4 W, lowering internal enclosure temperatures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #1a365d; color: #ffffff;\"\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eValue \/ Operational Limit\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCC-TAIX61\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e51307077-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eChannel Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e8 Configurable Input Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eInput Ranges Supported\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0-10 V DC \/ 4-20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003ePower Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e24 V DC ± 10%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eMaximum Power Draw\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e4 W maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e1.6 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e-25°C to +65°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eRelative Ambient Humidity\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0% to 95% (Non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eEnclosure Space and Mounting\u003c\/h3\u003e\n\u003cp\u003eMount the unit securely onto the Experion standard hardware carrier. Maintain its sleek 2.2 cm profile alignment with adjacent modules. Ensure unhindered vertical convective airflow within the cabinet grid to handle thermal regulation.\u003c\/p\u003e\n\n\u003ch3\u003eWiring Best Practices\u003c\/h3\u003e\n\u003cp\u003eRoute current and voltage instrument wires using separate shielded pairs. Terminate loops neatly at designated block screws. Keep low-voltage lines isolated from nearby high-current induction cables to secure real-time data integrity.\u003c\/p\u003e\n\n\u003ch3\u003eOperational Boundaries\u003c\/h3\u003e\n\u003cp\u003eVerify that continuous operating conditions remain within strict thermal lines of -25°C to +65°C and that ambient relative humidity never breaches 95% to avoid moisture-induced board tracks degradation.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eNative DCS Communication\u003c\/h3\u003e\n\u003cp\u003eThe module establishes fast and efficient data loops with Honeywell controllers, supporting real-time industrial monitoring without communication latency or driver mismatches.\u003c\/p\u003e\n\n\u003ch3\u003eSevere Climate Resilience\u003c\/h3\u003e\n\u003cp\u003eEngineered for brutal process setups, the rugged component structure maintains stable, uncompromised calibration metrics down to -25°C freezing points and up to +65°C peak temperatures.\u003c\/p\u003e\n\n\u003ch3\u003eOptimized Form Factor\u003c\/h3\u003e\n\u003cp\u003eThe 2.2 cm profile saves precious rail space, allowing system builders to pack high I\/O density inside compact control enclosures without violating thermal clear spaces.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does this specific assembly process both voltage and current signals simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes, the 8 channels are flexible and accommodate wide ranges including 0-10 V DC and 4-20 mA configurations depending on system parameter maps.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What power tolerances apply to the CC-TAIX61 board?\u003c\/strong\u003e\u003cbr\u003e\nA2: The module operates on a nominal 24 V DC bus and absorbs active fluctuations up to ± 10% without dropping input measurement data.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is this hardware designed for high-density control configurations?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, its thin 2.2 cm footprint combined with a low 4 W max thermal profile makes it suitable for dense multi-channel marshalling enclosures.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050730848388,"sku":"CC-TAIX61","price":261.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TAIX61_51307077-175.jpg?v=1779546965"},{"product_id":"honeywell-cc-pcnt02-c300-module-controller","title":"Honeywell CC-PCNT02 C300 Module Controller","description":"\u003ch2 style=\"color: #e67e22;\"\u003eHoneywell CC-PCNT02 C300 Module Controller\u003c\/h2\u003e\n\u003cp\u003eExperience \u003cstrong style=\"color: #e67e22;\"\u003eadvanced process control\u003c\/strong\u003e with the upgraded \u003cstrong style=\"color: #e67e22;\"\u003eCC-PCNT02\u003c\/strong\u003e module. This high-performance controller delivers reliable operation in demanding industrial environments with enhanced processing capabilities.\u003c\/p\u003e\n\u003ch3\u003eCore Technical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eModel:\u003c\/strong\u003e CC-PCNT02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eMeasurement Range:\u003c\/strong\u003e Programmable for various process variables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eAccuracy:\u003c\/strong\u003e ±0.1% of calibrated span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eOutput Signal:\u003c\/strong\u003e Ethernet with redundant communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eOperating Temperature:\u003c\/strong\u003e -30°C to 60°C (-22°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003ePower Requirements:\u003c\/strong\u003e 24V DC ±10%, 0.4A maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003ePhysical Dimensions:\u003c\/strong\u003e 89mm x 140mm x 38mm (3.5\" x 5.5\" x 1.5\")\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eUnit Weight:\u003c\/strong\u003e 0.3 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount in standard C300 mounting racks\u003c\/li\u003e\n\u003cli\u003eEnsure proper power supply (24V DC ±10%)\u003c\/li\u003e\n\u003cli\u003eConnect Ethernet cables for communication\u003c\/li\u003e\n\u003cli\u003eVerify grounding for optimal performance\u003c\/li\u003e\n\u003cli\u003eAllow adequate ventilation around the unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect upgrade replacement for \u003cstrong style=\"color: #e67e22;\"\u003eCC-PCNT01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFully compatible with C300 system architecture\u003c\/li\u003e\n\u003cli\u003eWorks with existing Honeywell control systems\u003c\/li\u003e\n\u003cli\u003eSupports legacy I\/O modules and components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE certified for European market\u003c\/li\u003e\n\u003cli\u003eUL listed for safety standards\u003c\/li\u003e\n\u003cli\u003eATEX certified for explosive atmospheres\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for hazardous substances\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2 industrial standard compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003e1-year limited warranty\u003c\/strong\u003e from date of purchase\u003c\/li\u003e\n\u003cli\u003eCovers manufacturing defects and component failures\u003c\/li\u003e\n\u003cli\u003eIncludes technical support during warranty period\u003c\/li\u003e\n\u003cli\u003eWarranty validation requires proof of purchase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eWhat are the main improvements in CC-PCNT02 compared to CC-PCNT01?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong style=\"color: #e67e22;\"\u003eCC-PCNT02\u003c\/strong\u003e features enhanced processing power, improved communication capabilities, and better integration with modern control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eCan I use this controller with my existing C300 system?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong style=\"color: #e67e22;\"\u003eCC-PCNT02\u003c\/strong\u003e is designed for seamless integration with current C300 architecture and existing installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eWhat is the warranty coverage for this product?\u003c\/strong\u003e\u003cbr\u003eHoneywell provides a comprehensive 1-year warranty covering manufacturing defects and component failures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050791436420,"sku":"CC-PCNT02","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PCNT02.jpg?v=1761743023"},{"product_id":"honeywell-cc-paoh01-hart-analog-output-module","title":"Honeywell CC-PAOH01 HART Analog Output Module","description":"\u003ch2\u003eHoneywell CC-PAOH01 HART Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAOH01\u003c\/strong\u003e delivers \u003cstrong style=\"color: #2e86ab;\"\u003eprecise 16-channel analog control\u003c\/strong\u003e with HART communication capability. This high-density output module provides \u003cstrong\u003eexceptional accuracy\u003c\/strong\u003e and \u003cstrong\u003efast response times\u003c\/strong\u003e for critical process control applications.\u003c\/p\u003e\n\u003ch3\u003eCore Technical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModel:\u003c\/strong\u003e CC-PAOH01 HART Analog Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOutput Type:\u003c\/strong\u003e 4-20 mA with HART protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eChannel Count:\u003c\/strong\u003e 16 isolated outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOutput Range:\u003c\/strong\u003e 0-21.1 mA directly settable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCalibrated Accuracy:\u003c\/strong\u003e ±0.35% of full scale at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eResolution:\u003c\/strong\u003e ±0.05% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eResponse Time:\u003c\/strong\u003e 80 ms to within 1% of final value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eTemperature Drift:\u003c\/strong\u003e 0.005% of FS\/°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eMax Load:\u003c\/strong\u003e 800Ω at 24VDC supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOutput Ripple:\u003c\/strong\u003e \u0026lt;100 mV peak-to-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eLinearity:\u003c\/strong\u003e ±0.05% of full scale nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eReadback Accuracy:\u003c\/strong\u003e ±4% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCompliant Voltage:\u003c\/strong\u003e 16V maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOpen Circuit Voltage:\u003c\/strong\u003e 22V maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eRedundancy Gap:\u003c\/strong\u003e 10ms maximum on switchover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOperating Temperature:\u003c\/strong\u003e -40°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eIsolation:\u003c\/strong\u003e 1500V AC channel-to-channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounts in standard 19-inch control racks\u003c\/li\u003e\n\u003cli\u003eRequires 22-28VDC power supply\u003c\/li\u003e\n\u003cli\u003eField wiring with shielded cables recommended\u003c\/li\u003e\n\u003cli\u003eHot-swappable design for easy maintenance\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting options available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne-year manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eCoverage for defects in materials and workmanship\u003c\/li\u003e\n\u003cli\u003eTechnical support included\u003c\/li\u003e\n\u003cli\u003eAdvanced replacement available\u003c\/li\u003e\n\u003cli\u003eGlobal service network support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat is the maximum load impedance supported?\u003c\/strong\u003e\u003cbr\u003eThe module supports up to 800Ω load resistance with 24VDC supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eDoes this module support HART communication?\u003c\/strong\u003e\u003cbr\u003eYes, the CC-PAOH01 fully supports HART protocol on all 16 channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat is the response time for output changes?\u003c\/strong\u003e\u003cbr\u003eThe output settles within 80 milliseconds to within 1% of the final value.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050791698564,"sku":"CC-PAOH01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAOH01.jpg?v=1761655914"},{"product_id":"cc-pdob01-24vdc-output-module-honeywell","title":"CC-PDOB01 24VDC Output Module | Honeywell","description":"\u003ch2\u003eHoneywell CC-PDOB01 Digital Output Card: High-Density 32-Channel Control Solution\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PDOB01\u003c\/strong\u003e digital output module provides \u003cstrong style=\"color: #2e86ab;\"\u003e32-channel digital control\u003c\/strong\u003e for industrial automation systems. Operating at \u003cstrong\u003e24VDC\u003c\/strong\u003e with \u003cstrong style=\"color: #2e86ab;\"\u003e1500V isolation\u003c\/strong\u003e, this card ensures reliable performance in demanding environments with zero interruption during redundancy switching.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModel:\u003c\/strong\u003e CC-PDOB01 with complete suffix information\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eChannels:\u003c\/strong\u003e 32 isolated outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eVoltage Range:\u003c\/strong\u003e 19-30VDC operating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCurrent Capacity:\u003c\/strong\u003e 0.5A per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eAccuracy:\u003c\/strong\u003e High precision digital output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eResponse Time:\u003c\/strong\u003e 10ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eIsolation Rating:\u003c\/strong\u003e 1500V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eTemperature Range:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Experion PKS systems\u003c\/li\u003e\n\u003cli\u003eC300 process controller\u003c\/li\u003e\n\u003cli\u003eSeries C I\/O modules\u003c\/li\u003e\n\u003cli\u003eIndustrial Ethernet networks\u003c\/li\u003e\n\u003cli\u003eStandard 19-inch racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE marked for European compliance\u003c\/li\u003e\n\u003cli\u003eUL certified for safety requirements\u003c\/li\u003e\n\u003cli\u003eATEX for hazardous locations\u003c\/li\u003e\n\u003cli\u003eIP67 environmental protection\u003c\/li\u003e\n\u003cli\u003eEMC directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Honeywell \u003cstrong\u003eCC-PDOB01\u003c\/strong\u003e digital output card\u003c\/li\u003e\n\u003cli\u003eComprehensive installation guide\u003c\/li\u003e\n\u003cli\u003eRequired mounting components\u003c\/li\u003e\n\u003cli\u003eOne-year manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eTechnical documentation CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat is the maximum load current per channel?\u003c\/strong\u003e\u003cbr\u003eEach channel supports 0.5A continuous current at 24VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCan this card be replaced during operation?\u003c\/strong\u003e\u003cbr\u003eYes, it features hot-swap capability for zero downtime maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat control systems support this module?\u003c\/strong\u003e\u003cbr\u003eCompatible with Honeywell Experion PKS and C-series control platforms.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050791731332,"sku":"CC-PDOB01","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PDOB01.jpg?v=1761654982"},{"product_id":"honeywell-cc-psv201-servo-output-module","title":"Moduł wyjściowy serwo Honeywell CC-PSV201","description":"\u003ch2\u003ePrzegląd produktu\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCC-PSV201\u003c\/strong\u003e to wysokoprecyzyjny pozycjoner zaworu serwo zaprojektowany dla platformy Honeywell Experion PKS. Steruje krytycznymi siłownikami hydraulicznymi w turbinach parowych i sprężarkach odśrodkowych, łącząc 16-bitowe bipolarne wyjścia prądowe z dwukanałową informacją zwrotną LVDT. Moduł eliminuje mechaniczne zacinanie dzięki programowalnym częstotliwościom drgań, zapewniając ultra-płynne pozycjonowanie zaworu i reakcję na poziomie milisekund w wymagających środowiskach przemysłowych.\u003c\/p\u003e\n\n\u003ch2\u003eKonfiguracja techniczna\u003c\/h2\u003e\n\u003ch3\u003eKluczowe zalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003eTen sprzęt zapewnia wszechstronny interfejs dla konfiguracji LVDT 3\/4\/5\/6-przewodowych, gwarantując bezproblemową integrację z różnorodnymi czujnikami informacji zwrotnej. Obsługuje sześć zakresów bipolarnego prądu do ±320 mA i posiada szybki 15 ms czas przełączania dla systemów redundantnych o wysokiej dostępności. Transformatorowa izolacja galwaniczna ±500 VDC chroni sieć sterującą przed zakłóceniami elektrycznymi po stronie pola.\u003c\/p\u003e\n\n\u003ch2\u003eDane techniczne\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"padding: 10px; text-align: left;\"\u003eParametr\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; text-align: left;\"\u003eSpecyfikacje\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px;\"\u003eKanały\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px;\"\u003e2 wyjścia serwomechanizmu \/ 2 wejścia LVDT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px;\"\u003eRozdzielczość\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px;\"\u003e16-bitowy DAC i ADC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px;\"\u003eZakres bipolarnego prądu\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px;\"\u003e±10 do ±320 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px;\"\u003eWzbudzenie LVDT\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px;\"\u003e8 V RMS przy 2,5–3,2 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px;\"\u003eDokładność\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px;\"\u003e±0,075% FS (przy 23,5 ±2°C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px;\"\u003eCzęstotliwość skanowania\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px;\"\u003e2,5 ms (LVDT)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px;\"\u003eWaga\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px;\"\u003e0,3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstrukcja instalacji i konserwacji\u003c\/h2\u003e\n\u003cp\u003eUpewnij się, że całe okablowanie LVDT wykorzystuje wysokiej jakości ekranowane skrętkowe kable, aby zachować integralność sygnału na odległość. \u003cstrong\u003eCC-PSV201\u003c\/strong\u003e wymaga, aby częstotliwość wzbudzenia mieściła się w ±5 Hz od skonfigurowanego punktu nastawczego dla optymalnej stabilności. Przy konfigurowaniu amplitudy drgań (0–10%) zacznij od dolnego progu, aby zrównoważyć szybkość reakcji zaworu z trwałością mechaniczną.\u003c\/p\u003e\n\n\u003ch2\u003eZalety inżynieryjne\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZapobieganie zacinaniu:\u003c\/strong\u003e Regulowany drganie 25–60 Hz utrzymuje trzpienie zaworów w mikroruchu, zapobiegając zacinaniu.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWysoka precyzja:\u003c\/strong\u003e Rozdzielczość 16-bitowa rejestruje drobne zmiany procesu dla doskonałej stabilności pętli.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKompaktowa forma:\u003c\/strong\u003e Moduł o wadze 0,3 kg pasuje do standardowego mocowania Honeywell IOTA, umożliwiając wysoką gęstość układu w szafach.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eNajczęściej zadawane pytania techniczne\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Jak moduł radzi sobie z redundancją informacji zwrotnej?\u003c\/strong\u003e\u003cbr\u003e\nA1: Sprzęt obsługuje dwukanałowe wejścia LVDT, umożliwiając lustrzaną informację zwrotną lub niezależne sterowanie dwoma oddzielnymi zespołami zaworów.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Czy analogowe wejścia i kanały LVDT mogą być używane jednocześnie?\u003c\/strong\u003e\u003cbr\u003e\nA2: Nie, wejścia 4–20 mA lub napięciowe wykluczają się wzajemnie z interfejsem LVDT na tym sprzęcie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Jaki jest maksymalny zasięg sygnałów LVDT?\u003c\/strong\u003e\u003cbr\u003e\nA3: Zasięg zależy od pojemności kabla, ale wysoka impedancja wejściowa 25 kΩ zapewnia silne odzyskiwanie sygnału w większości standardowych przemysłowych instalacji kablowych.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050791764100,"sku":"CC-PSV201","price":227.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PSV201.jpg?v=1777970762"},{"product_id":"honeywell-cc-puio01-universal-i-o-module-32-channel","title":"Honeywell CC-PUIO01 Universal I\/O Module | 32-Channel","description":"\u003ch2\u003eHoneywell CC-PUIO01 Universal I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #e67e22;\"\u003eHoneywell CC-PUIO01\u003c\/strong\u003e (51454205-175) is a versatile 32-channel universal input\/output module designed for flexible process control applications. This reliable module supports multiple signal types and operates in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eModel:\u003c\/strong\u003e CC-PUIO01 (51454205-175)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eInput Channels:\u003c\/strong\u003e 32 universal channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eAnalog Input Range:\u003c\/strong\u003e 0-20mA or 4-20mA (active)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eAnalog Output Range:\u003c\/strong\u003e 4-20mA (active)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eOperating Voltage:\u003c\/strong\u003e 24V DC typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C (-4°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eWeight:\u003c\/strong\u003e 0.35kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eDimensions:\u003c\/strong\u003e Standard C-series module size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003e32 universal channels\u003c\/strong\u003e for maximum flexibility\u003c\/li\u003e\n\u003cli\u003eSupport for multiple analog signal types\u003c\/li\u003e\n\u003cli\u003eCompact design for space-efficient installation\u003c\/li\u003e\n\u003cli\u003eRobust construction for industrial environments\u003c\/li\u003e\n\u003cli\u003eEasy integration with Experion PKS systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong style=\"color: #e67e22;\"\u003e1-year manufacturer warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eCovers defects in materials and workmanship\u003c\/li\u003e\n\u003cli\u003eTechnical support included\u003c\/li\u003e\n\u003cli\u003eRequires valid proof of purchase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eWhat types of signals can the CC-PUIO01 handle?\u003c\/strong\u003e\u003cbr\u003eThe module supports 0-20mA and 4-20mA analog input signals, and 4-20mA analog output signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eIs this module compatible with existing Honeywell systems?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong style=\"color: #e67e22;\"\u003eCC-PUIO01\u003c\/strong\u003e is designed for seamless integration with Experion PKS and C-series systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #e67e22;\"\u003eWhat is the warranty period for this product?\u003c\/strong\u003e\u003cbr\u003eHoneywell provides a 1-year warranty covering manufacturing defects and component failures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050791796868,"sku":"CC-PUIO01","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PUIO01.jpg?v=1761743124"},{"product_id":"honeywell-cc-tdor01-51308376-175-16-channel-relay-module","title":"Honeywell CC-TDOR01 51308376-175 16-Channel Relay Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #007bff;\"\u003eHoneywell CC-TDOR01 51308376-175\u003c\/strong\u003e serves as a high-density 16-channel Digital Output Relay Module structured for the Series C Digital Output Field Termination Assembly (IOTA) architecture. This critical control component drives interposing relays, solenoids, motor starters, and indicators across automated networks. It delivers deterministic switching and galvanic line isolation between automated controller logic and high-energy field loads.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technological Advantages\u003c\/h2\u003e\n\u003ch3\u003eVersatile Dual-State Relay Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module board integrates 16 isolated digital outputs configurable for both Normally Open (NO) and Normally Closed (NC) dry contact setups, allowing physical integration into diverse fail-safe logic designs without external switching hardware.\u003c\/p\u003e\n\n\u003ch3\u003eAdvanced Safety and Load Protection\u003c\/h3\u003e\n\u003cp\u003eOnboard hardware protections defend the control node from erratic field events. Active overvoltage protection shields internal lines against induction spikes, while short circuit protection limits current surges to secure uninterrupted network operation.\u003c\/p\u003e\n\n\u003ch3\u003eComprehensive Visual Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe hardware features a matrix of 16 individual diagnostic status LEDs aligned with an active self-diagnostics auto-check subsystem, allowing field technicians to identify channel states and loop health immediately.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #1a365d; color: #ffffff;\"\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eValue \/ Operational Limit\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCC-TDOR01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e51308376-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eDigital Output Relay Module (Series C IOTA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e16 Discrete Relay Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eRelay Contact Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eNormally Open (NO) \/ Normally Closed (NC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eInput Power Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e24 V DC ± 10%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eActive Power Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e4 W maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModbus RTU over RS-485 Interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e-10°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eRelative Humidity Limits\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0% to 95% (Non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eMechanical DIN Rail Mounting\u003c\/h3\u003e\n\u003cp\u003eMount the 0.5 kg assembly horizontally onto a standard 35mm DIN rail profile inside the marshalling cabinet. Ensure rigid latch engagement with the rail track to minimize environmental vibration or physical alignment drift during fast mechanical relay actuation cycles.\u003c\/p\u003e\n\n\u003ch3\u003eSecure Terminal Wiring\u003c\/h3\u003e\n\u003cp\u003eConnect field control lines using the robust integrated screw terminals. Route inductive load cables separated from low-voltage communications lines. Terminate connections firmly to prevent contact heating and ensure stable transmission across all 16 discrete outputs.\u003c\/p\u003e\n\n\u003ch3\u003eRS-485 Bus Integration\u003c\/h3\u003e\n\u003cp\u003eWhen running Modbus RTU telemetry over the RS-485 communication link, utilize standard shielded twisted-pair cables. Ground the communication line shield loop at a single node to eliminate data distortions induced by magnetic common-mode noise fields.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eNative Series C Architecture Integration\u003c\/h3\u003e\n\u003cp\u003eThis module provides drop-in mechanical and digital compatibility with Honeywell Series C IOTA systems, dropping installation times and guaranteeing native signal processing speeds without system bus delays.\u003c\/p\u003e\n\n\u003ch3\u003eExtended Operational Temperature Lines\u003c\/h3\u003e\n\u003cp\u003eThe thermal-hardened components ensure reliable relay contact switching from extreme cold states at -10°C up to high-density cabinet temperatures hitting +60°C without contact timing drift.\u003c\/p\u003e\n\n\u003ch3\u003eDistributed Modbus Connectivity\u003c\/h3\u003e\n\u003cp\u003eIncorporating direct Modbus RTU communications across RS-485 data paths permits versatile remote mounting schemes, giving engineering firms the freedom to place control rows close to the active field equipment.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What power fluctuations can the internal 24 V DC circuit safely tolerate?\u003c\/strong\u003e\u003cbr\u003e\nA1: The module accepts a continuous voltage variance line of ± 10%, keeping its 16 status LEDs and switching logic operational during auxiliary power fluctuations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How do technicians identify an inactive channel or failed module state?\u003c\/strong\u003e\u003cbr\u003e\nA2: The hardware executes automated internal self-diagnostics checks. Any discrepancies or failures can be identified by cross-referencing the 16 onboard status LEDs or reading diagnostic registers over the Modbus interface.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module manage inductive AC field loads directly?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, through its isolated Normally Open\/Closed dry contacts. However, deploying external RC snubbers or suppressing diodes across inductive loads is recommended to protect the internal contacts from arc wear.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050791895172,"sku":"CC-TDOR01","price":274.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TDOR01-4.jpg?v=1779548735"},{"product_id":"dc-tfb402-honeywell-fieldbus-interface-module","title":"Moduł interfejsu Fieldbus DC-TFB402 Honeywell","description":"\u003ch2 style=\"color:#0051A2;\"\u003eHoneywell DC-TFB402\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0051A2;\"\u003eHoneywell DC-TFB402\u003c\/strong\u003e (51307616-176) — Moduł interfejsu Fieldbus IP65 do automatyki przemysłowej. Obsługuje komunikację RS-485 i Ethernet. Współpracuje z systemami PLC, DCS i TSI.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 x 12 x 5,5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e\u003cstrong\u003eMateriał\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePokrycie dla trwałości\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e\u003cstrong\u003eZakres temperatur\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C do 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e\u003cstrong\u003eMoc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e\u003cstrong\u003eInterfejs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e\u003cstrong\u003eOchrona\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eUwagi dotyczące instalacji:\u003c\/strong\u003e Ustaw przerwę na -9V DC (środkowy zakres). Minimalny promień gięcia kabla: 50 mm. Wyjście: 4-20 mA lub 0-10V DC plus Modbus RTU lub TCP.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDlaczego ten model:\u003c\/strong\u003e Obudowa pokryta powłoką odporną na korozję. Działa jednocześnie z tradycyjnymi pętlami 4-20 mA i nowoczesnymi sieciami Ethernet.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Czy mogę użyć zasilania 24V DC?\u003c\/strong\u003e\u003cbr\u003eA1: Nie. Tylko 12V DC. Użycie 24V uszkadza urządzenie.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Czy RS-485 jest izolowany?\u003c\/strong\u003e\u003cbr\u003eA2: Tak. Izolacja optyczna 1500Vrms. Tłumi zakłócenia VFD.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Montaż bezpośrednio na wibrującej maszynie?\u003c\/strong\u003e\u003cbr\u003eA3: Użyj gumowych izolatorów lub opcjonalnej osłony odciążającej (sprzedawane osobno).\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050795106436,"sku":"DC-TFB402","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DC-TFB402-1.jpg?v=1779632102"},{"product_id":"honeywell-cc-pfb401-fieldbus-interface-module","title":"Honeywell CC-PFB401 Fieldbus Interface Module","description":"\u003ch2\u003eHoneywell CC-PFB401 Fieldbus Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PFB401\u003c\/strong\u003e delivers \u003cstrong style=\"color: #2e86ab;\"\u003ehigh-performance FOUNDATION Fieldbus connectivity\u003c\/strong\u003e for industrial automation systems. This robust interface module supports \u003cstrong\u003efour independent H1 networks\u003c\/strong\u003e with advanced diagnostics and \u003cstrong\u003e1500V isolation\u003c\/strong\u003e for reliable process communication.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eManufacturer:\u003c\/strong\u003e Honeywell International\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModel Number:\u003c\/strong\u003e CC-PFB401 Fieldbus Interface Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModule Type:\u003c\/strong\u003e Series C FOUNDATION Fieldbus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003ePhysical Interface:\u003c\/strong\u003e H1 Fieldbus standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eNetwork Capacity:\u003c\/strong\u003e 4 independent H1 networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eDevices per Network:\u003c\/strong\u003e Maximum 16 field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eIsolation Rating:\u003c\/strong\u003e 1500 VDC network isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModule Weight:\u003c\/strong\u003e 0.3 kilograms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eMacrocycle Periods:\u003c\/strong\u003e 250ms to 32 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eConfiguration Options:\u003c\/strong\u003e Non-redundant or redundant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003ePower Requirements:\u003c\/strong\u003e 24 VDC, 0.5A consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eDiagnostic Capabilities:\u003c\/strong\u003e Enhanced real-time monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eNetwork Security:\u003c\/strong\u003e High isolation voltage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eRedundancy Support:\u003c\/strong\u003e Side-by-side configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCommunication Speed:\u003c\/strong\u003e 31.25 kbps H1 Fieldbus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eData Integrity:\u003c\/strong\u003e Error detection and correction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 19-inch rack mounting\u003c\/li\u003e\n\u003cli\u003e24VDC power supply connection\u003c\/li\u003e\n\u003cli\u003eShielded fieldbus cable requirements\u003c\/li\u003e\n\u003cli\u003eProper grounding for noise immunity\u003c\/li\u003e\n\u003cli\u003eTerminator installation on each segment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOperating Temperature:\u003c\/strong\u003e -40°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eVibration Resistance:\u003c\/strong\u003e 2g @ 10-500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eShock Tolerance:\u003c\/strong\u003e 15g for 11ms duration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne-year comprehensive warranty\u003c\/li\u003e\n\u003cli\u003eManufacturer defect coverage\u003c\/li\u003e\n\u003cli\u003eTechnical support included\u003c\/li\u003e\n\u003cli\u003eGlobal service network access\u003c\/li\u003e\n\u003cli\u003eReplacement unit availability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eHow many field devices can each H1 network support?\u003c\/strong\u003e\u003cbr\u003eEach H1 network supports up to 16 fieldbus devices maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat redundancy options are available?\u003c\/strong\u003e\u003cbr\u003eThe module supports non-redundant or side-by-side redundant configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eIt operates from -40°C to 70°C in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050804314244,"sku":"CC-PFB401","price":285.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/HoneywellCC-PFB40151405044-175.jpg?v=1761656743"},{"product_id":"cc-pcnt01-honeywell-experion-pks-c300-controller","title":"Sterownik Honeywell Experion PKS C300 CC-PCNT01","description":"\u003ch2 style=\"color: #2c3e50;\"\u003ePrzegląd produktu\u003c\/h2\u003e\n\u003cp\u003eHoneywell \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eCC-PCNT01\u003c\/strong\u003e\u003c\/span\u003e to podstawowa jednostka przetwarzająca systemu sterowania Experion PKS C300. Zaprojektowany do realizacji złożonych strategii sterowania z wysoką precyzją, ten moduł zapewnia deterministyczną wydajność wymaganą dla krytycznych procesów przemysłowych.\u003c\/p\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eGłówne zalety techniczne\u003c\/h2\u003e\n\u003cp\u003eModuł sterownika został zaprojektowany z myślą o maksymalnej dostępności i przejrzystości działania. Posiada wbudowaną autodiagnostykę, która nieustannie monitoruje stan sprzętu, znacznie skracając średni czas naprawy (MTTR). Zintegrowany interfejs LCD umożliwia inżynierom natychmiastowy dostęp do danych o stanie i konfiguracji bez konieczności używania narzędzi zewnętrznych. Ponadto \u003cstrong\u003eCC-PCNT01\u003c\/strong\u003e obsługuje aktualizacje oprogramowania układowego przez sieć, co pozwala na płynne ulepszanie systemu i poprawki bezpieczeństwa przy zachowaniu integralności istniejącej konfiguracji sprzętowej.\u003c\/p\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eSpecyfikacje techniczne\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"border: 1px solid #dee2e6; padding: 12px; text-align: left;\"\u003eParametr\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #dee2e6; padding: 12px; text-align: left;\"\u003eSzczegóły specyfikacji\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003eCC-PCNT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eProcesor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003eDwurdzeniowy procesor czasu rzeczywistego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eNapięcie zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e24 V DC (0,311 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003ePojemność I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003eDo 64 punktów analogowych\/cyfrowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e0,25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e-40°C do 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eOdporność na wstrząsy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e50 g szczyt (11 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eInstrukcja instalacji i inżynierii\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCC-PCNT01\u003c\/strong\u003e został zaprojektowany do uproszczonej integracji poprzez bezpośrednie mocowanie do zespołu zakończeń wejść\/wyjść (IOTA). Ta metoda montażu zmniejsza złożoność okablowania w terenie i poprawia integralność sygnału elektrycznego. Aby zapewnić maksymalną wydajność, inżynierowie powinni zweryfikować, że zasilanie 24 V DC pozostaje stabilne w granicach ±10%, aby uwzględnić precyzyjny pobór prądu modułu. Solidna odporność modułu na wibracje (testowana do 10 g szczyt) pozwala na instalację w środowiskach o wysokim obciążeniu mechanicznym, w pobliżu ciężkich maszyn obrotowych.\u003c\/p\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eZalety inżynieryjne\u003c\/h2\u003e\n\u003cp\u003ePlatforma sterownika C300 stanowi przełom w skalowalności rozproszonego sterowania. CC-PCNT01 jest wyjątkowo odporny na czynniki środowiskowe, co zapewnia nieprzerwane sterowanie procesem nawet w nieklimatyzowanych obudowach polowych. Jego zdolność do obsługi zarówno punktów analogowych, jak i cyfrowych w jednym środowisku przetwarzania pozwala na bardziej kompaktową konstrukcję i niższy całkowity koszt posiadania (TCO) w porównaniu z tradycyjnymi architekturami sterowników wielomodułowych.\u003c\/p\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eNajczęściej zadawane pytania techniczne\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eP1: Jaka jest zaleta dwurdzeniowego procesora w CC-PCNT01?\u003c\/strong\u003e\u003cbr\u003eO1: Architektura dwurdzeniowa oddziela wykonywanie sterowania od zadań komunikacyjnych, zapobiegając wpływowi ruchu sieciowego na szybkość lub niezawodność pętli sterowania w czasie rzeczywistym.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP2: Czy ten moduł wymaga specjalistycznego chłodzenia?\u003c\/strong\u003e\u003cbr\u003eO2: Nie. CC-PCNT01 jest przystosowany do pracy w temperaturze do 70°C (158°F). Standardowe chłodzenie konwekcyjne w odpowiednio wentylowanej szafie jest wystarczające dla większości zastosowań przemysłowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP3: Jak uzyskać dostęp do diagnostyki, jeśli sieć systemowa jest niedostępna?\u003c\/strong\u003e\u003cbr\u003eO3: Zintegrowany wyświetlacz LCD zapewnia lokalne informacje diagnostyczne i kody statusu bezpośrednio na sprzęcie modułu, umożliwiając szybkie rozwiązywanie problemów nawet bez połączenia ze stacją roboczą.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050817355908,"sku":"CC-PCNT01","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PCNT01.jpg?v=1777965742"},{"product_id":"honeywell-cc-pcf901-control-firewall-module","title":"Honeywell CC-PCF901 Control Firewall Module","description":"\u003ch2\u003eHoneywell CC-PCF901 Control Firewall Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PCF901\u003c\/strong\u003e delivers \u003cstrong style=\"color: #2e86ab;\"\u003eadvanced network security\u003c\/strong\u003e for industrial control systems. This robust firewall module provides \u003cstrong\u003emulti-layered protection\u003c\/strong\u003e with high-speed throughput and \u003cstrong\u003ereal-time monitoring\u003c\/strong\u003e to safeguard critical process operations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eManufacturer:\u003c\/strong\u003e Honeywell Process Solutions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModel Number:\u003c\/strong\u003e CC-PCF901 Control Firewall Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eProduct Type:\u003c\/strong\u003e Industrial Network Security\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003ePower Requirements:\u003c\/strong\u003e 24 VDC, 0.3A maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModule Weight:\u003c\/strong\u003e 0.3 kilograms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eDimensions:\u003c\/strong\u003e Standard Series C module size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eMounting:\u003c\/strong\u003e 19-inch rack compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCooling:\u003c\/strong\u003e Natural convection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSecurity Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eFirewall Protection:\u003c\/strong\u003e Multi-layered security protocols\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eIntrusion Detection:\u003c\/strong\u003e Real-time threat monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eAccess Control:\u003c\/strong\u003e Advanced authentication systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eLog Management:\u003c\/strong\u003e Comprehensive activity logging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eAudit Compliance:\u003c\/strong\u003e Detailed reporting capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eProtocol Filtering:\u003c\/strong\u003e Industrial protocol awareness\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eVPN Support:\u003c\/strong\u003e Secure remote access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eThreat Prevention:\u003c\/strong\u003e Advanced malware protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eThroughput Capacity:\u003c\/strong\u003e Up to 1 Gbps data processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eNetwork Latency:\u003c\/strong\u003e Less than 5 milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eConnection Limit:\u003c\/strong\u003e 512 simultaneous sessions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eFailover Time:\u003c\/strong\u003e Under 50 milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eAvailability:\u003c\/strong\u003e 99.999% uptime capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003ePacket Inspection:\u003c\/strong\u003e Deep packet analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eUpdate Frequency:\u003c\/strong\u003e Regular security updates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eBackup Speed:\u003c\/strong\u003e Rapid configuration backup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOperating Temperature:\u003c\/strong\u003e -40°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eVibration Resistance:\u003c\/strong\u003e 2g operational\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eShock Tolerance:\u003c\/strong\u003e 15g peak acceleration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 62443 cybersecurity standards\u003c\/li\u003e\n\u003cli\u003eUL Listed for safety requirements\u003c\/li\u003e\n\u003cli\u003eCE Marked for European markets\u003c\/li\u003e\n\u003cli\u003eNIST framework compliance\u003c\/li\u003e\n\u003cli\u003eISO 27001 security standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Honeywell \u003cstrong\u003eCC-PCF901\u003c\/strong\u003e firewall module\u003c\/li\u003e\n\u003cli\u003eInstallation and configuration guide\u003c\/li\u003e\n\u003cli\u003eMounting hardware kit\u003c\/li\u003e\n\u003cli\u003eSecurity documentation\u003c\/li\u003e\n\u003cli\u003eCompliance certificates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne-year manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eSecurity update service\u003c\/li\u003e\n\u003cli\u003eTechnical support included\u003c\/li\u003e\n\u003cli\u003eFirmware upgrade access\u003c\/li\u003e\n\u003cli\u003eEmergency repair service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat is the maximum data throughput?\u003c\/strong\u003e\u003cbr\u003eThe firewall handles up to 1 Gbps with less than 5ms latency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eHow many connections does it support?\u003c\/strong\u003e\u003cbr\u003eIt maintains 512 simultaneous connections with real-time monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat cybersecurity standards does it meet?\u003c\/strong\u003e\u003cbr\u003eCompliant with IEC 62443 and NIST cybersecurity frameworks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050817519748,"sku":"CC-PCF091","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PCF091.jpg?v=1761662142"},{"product_id":"cc-tdob01-51308371-175-honeywell-experion-digital-output","title":"CC-TDOB01 51308371-175 Honeywell Experion Digital Output","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eCC-TDOB01\u003c\/strong\u003e (Part Number 51308371-175) is a high-performance Digital Output Module designed for industrial automation control. Engineered for high reliability, this module operates as a crucial interface on the digital output module backplane. It accurately switches discrete 24 V DC field devices while maintaining electrical isolation between control logic and harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eCore Technical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Channel Density:\u003c\/strong\u003e Provides 16 independent output channels in a compact, space-saving form factor to optimize cabinet layouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Current Handling:\u003c\/strong\u003e Supports up to 1 A per channel, allowing direct control of standard solenoids, relays, and indicators without intermediate hardware.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient Thermal Design:\u003c\/strong\u003e Consumes only 3 W of power, minimizing heat dissipation inside enclosed control panels to prolong system life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eSpecification Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCC-TDOB01 \/ 51308371-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDigital Output Module (Backplane Mounted)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e16 Output Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMax Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e3 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e100 mm x 150 mm x 30 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMODBUS RTU (Baud Rate: 9600 bps)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e-20°C to +60°C | 10% to 90% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCompliance \u0026amp; Ratings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCE, UL Certified | IP54 Rated Housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eEngineering Installation \u0026amp; Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBackplane Seating:\u003c\/strong\u003e Align the module guide rails carefully with the digital output module backplane slot. Press firmly until the locking mechanism clicks securely to guarantee continuous MODBUS RTU connection bus alignment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e Leave adequate clearance around the panel assembly to maintain ambient airflow within the -20°C to +60°C operating standard, maximizing hardware life.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Integrity:\u003c\/strong\u003e Ensure all inductive field loads (solenoids\/relays) utilize proper suppression diodes to protect the 1 A solid-state output channels from inductive voltage spikes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Choose This Module\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Features an IP54 protection rating and high-grade electrical isolation to safeguard critical PLC\/DCS processors against field-side faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Power Control:\u003c\/strong\u003e Delivers clean, stable 24 V DC power switching to field components, reducing signal noise and false trips in critical automation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the maximum load capacity for each individual channel?\u003c\/strong\u003e\u003cbr\u003e\nA1: Each of the 16 output channels handles a maximum continuous current of 1 A at 24 V DC, making it suitable for driving field actuators directly.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Does this module require specialized communication drivers?\u003c\/strong\u003e\u003cbr\u003e\nA2: No. The hardware integrates native MODBUS RTU communication at a standard baud rate of 9600 bps, ensuring seamless connectivity across standard automation networks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can the CC-TDOB01 be hot-swapped onto the backplane during operation?\u003c\/strong\u003e\u003cbr\u003e\nA3: For physical component protection and safety integrity, always refer to your specific system architecture configuration manuals. Ensure the local system environment complies with non-hazardous area rules before extracting any module from its backplane slot.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050817847428,"sku":"CC-TDOB01","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TDOB01-1_cd415cb9-16bc-4ecd-afd6-5854fea7da78.jpg?v=1779543736"},{"product_id":"cc-tfb412-honeywell-fieldbus-iota-module-12vdc","title":"Moduł Honeywell Fieldbus IOTA CC-TFB412 | 12VDC","description":"\u003ch2 style=\"color:#0055A4;\"\u003ePrzegląd produktu\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0055A4;\"\u003eCC-TFB412 (51307618-176)\u003c\/strong\u003e to moduł interfejsu Fieldbus firmy Honeywell. Zarządza komunikacją warstwy fizycznej dla Experion PKS. Ten moduł zapewnia niezawodne trasowanie sygnału i dystrybucję zasilania.\u003c\/p\u003e\n\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003eHoneywell\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eNumer produktu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eCC-TFB412 \/ 51307618-176\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eNapięcie\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e12 V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003ePrąd\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e100 mA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°F do 185°F (-40°C do +85°C)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°F do 185°F (-40°C do +85°C)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eProtokół\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eFoundation Fieldbus H1 (31,25 kbit\/s)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eGrubość przewodu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e12 do 24 AWG\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstrukcja montażu\u003c\/h3\u003e\n\u003cp\u003eZainstaluj terminator 100Ω na końcu magistrali. Podłącz ekran kabla do dedykowanego zacisku uziemienia. Sprawdź polaryzację (V+ i V-) przed zasileniem karty FIM. Użyj kabla 18 AWG dla segmentów do 1900 metrów.\u003c\/p\u003e\n\n\u003ch3\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003eTen moduł działa niezawodnie w temperaturach od -40°F do 185°F. Zawiera ochronę przed odwrotnym napięciem i filtrację EMC. CC-TFB412 integruje się bezproblemowo z systemami Experion PKS i starszymi seriami 3300.\u003c\/p\u003e\n\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Czy to obsługuje Profibus PA?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Tak. CC-TFB412 działa zarówno z Foundation Fieldbus H1, jak i Profibus PA.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Czy obsługiwane jest wymienianie na gorąco (hot-swap)?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Nie. Wyłącz segment przed odłączeniem taśmy od karty FIM.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Co się stanie, jeśli prąd przekroczy 100 mA?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Występuje spadek napięcia. Użyj kondycjonera zasilania fieldbus (51307897-100) dla segmentów o dużej mocy.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050818207876,"sku":"CC-TFB412","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TFB412.jpg?v=1779626787"},{"product_id":"cc-krebr5-honeywell-control-firewall-module","title":"Moduł zapory kontrolnej Honeywell CC-KREBR5","description":"\u003ch2 style=\"color: #303f9f;\"\u003ePrzegląd produktu\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #303f9f;\"\u003eCC-KREBR5\u003c\/strong\u003e to wysokowydajna zapora kontrolna zaprojektowana dla architektur Honeywell Experion PKS serii C. Chroni sterowniki C300 przed zalewaniem sieci i nieautoryzowanym ruchem, zapewniając sprzętową warstwę bezpieczeństwa. Gwarantuje deterministyczną komunikację i zabezpiecza sieć sterującą przed burzami rozgłoszeniowymi, utrzymując stabilność systemu w krytycznych środowiskach procesowych.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eKluczowe zalety techniczne\u003c\/h2\u003e\n\u003cp\u003eTen moduł zapewnia przepustowość 500 Mbps z wbudowanym kształtowaniem ruchu, aby priorytetyzować niezbędne dane sterujące. Posiada izolację galwaniczną 1000 V DC, chroniącą magistralę systemową przed zakłóceniami elektrycznymi. Zarządzając do 64 jednoczesnych sesji, zapobiega atakom typu „odmowa usługi” bez wpływu na opóźnienia przetwarzania sterownika.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eDane techniczne\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n    \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eFunkcja\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSzczegóły\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMaksymalna przepustowość\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e500 Mbps\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIzolacja\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1000 V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eObciążenie zasilania\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMaks. 4W\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFormat\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIOTA serii C\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eMontaż i konserwacja\u003c\/h2\u003e\n\u003cp\u003eZamontuj jednostkę bezpośrednio na IOTA serii C. Do wszystkich połączeń sieciowych używaj ekranowanego kabla Cat6, aby zapewnić odpowiednie uziemienie. Konfiguracja jest zarządzana za pomocą Experion Studio lub lokalnego portu konsoli. Moduł obsługuje hot-swap, co pozwala na wymianę lub konserwację bez wyłączania węzła sterującego.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eZalety inżynieryjne\u003c\/h2\u003e\n\u003cp\u003eModuł oferuje natywną integrację z C300, odciążając zadania związane z bezpieczeństwem sieci od głównego procesora sterownika. Jego kompaktowa, energooszczędna konstrukcja idealnie pasuje do istniejących szaf i działa niezawodnie w temperaturach do 60°C, zapewniając solidne rozwiązanie „Obrony w Głąb” dla zasobów przemysłowych.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eNajczęściej zadawane pytania techniczne\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCzy wymagane jest zewnętrzne zasilanie?\u003c\/strong\u003e\u003cbr\u003eNie, moduł pobiera zasilanie bezpośrednio z magistrali IOTA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy obsługuje hot-swap?\u003c\/strong\u003e\u003cbr\u003eTak, można go wymieniać podczas pracy i działania systemu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIle sesji może obsłużyć?\u003c\/strong\u003e\u003cbr\u003eObsługuje do 64 jednoczesnych sesji komunikacyjnych.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050818928772,"sku":"CC-KREBR5","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-KREBR5.jpg?v=1777966666"},{"product_id":"honeywell-cc-pdil01-digital-input-module-24vdc","title":"Honeywell CC-PDIL01 Digital Input Module | 24VDC","description":"\u003ch2\u003eHoneywell CC-PDIL01 Digital Input Module: Precision 24VDC Field Interface\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PDIL01\u003c\/strong\u003e digital input module delivers \u003cstrong style=\"color: #2e86ab;\"\u003ereliable 24VDC field signal acquisition\u003c\/strong\u003e for industrial control systems. Part of the DI-24 series, this module ensures \u003cstrong\u003eaccurate signal conversion\u003c\/strong\u003e with fast response times and robust performance in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eProduct Number:\u003c\/strong\u003e CC-PDIL01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eProduct Series:\u003c\/strong\u003e DI-24 Digital Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOperating Voltage:\u003c\/strong\u003e 18-30 VDC range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eON State Threshold:\u003c\/strong\u003e ≥13 VDC or ≥3 mA input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOFF State Threshold:\u003c\/strong\u003e ≤5 VDC or ≤1.2 mA input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eInput Impedance:\u003c\/strong\u003e 4.2 kΩ nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eResponse Time:\u003c\/strong\u003e 5 ms ±20% including filtering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eField Resistance ON:\u003c\/strong\u003e ≤300 Ω at 15 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eField Resistance OFF:\u003c\/strong\u003e ≥30 kΩ at 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eIsolation Rating:\u003c\/strong\u003e 1500 VAC continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e:0.5kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOperating Temperature:\u003c\/strong\u003e -40°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Experion PKS control systems\u003c\/li\u003e\n\u003cli\u003eSeries C I\/O architecture platforms\u003c\/li\u003e\n\u003cli\u003eIndustrial Ethernet communication networks\u003c\/li\u003e\n\u003cli\u003eLegacy Honeywell TPS systems with adapters\u003c\/li\u003e\n\u003cli\u003eThird-party DCS with appropriate interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed for safety standards\u003c\/li\u003e\n\u003cli\u003eCE Marked for European markets\u003c\/li\u003e\n\u003cli\u003eATEX compliance for hazardous areas\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2 programmable controllers\u003c\/li\u003e\n\u003cli\u003eRoHS compliant manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Honeywell \u003cstrong\u003eCC-PDIL01\u003c\/strong\u003e digital input module\u003c\/li\u003e\n\u003cli\u003eInstallation and operation manual\u003c\/li\u003e\n\u003cli\u003eMounting hardware kit\u003c\/li\u003e\n\u003cli\u003eConfiguration guide documentation\u003c\/li\u003e\n\u003cli\u003eProduct certification sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat input signals does the CC-PDIL01 accept?\u003c\/strong\u003e\u003cbr\u003eThe module accepts 24VDC digital signals with 18-30VDC operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eHow fast does the module respond to input changes?\u003c\/strong\u003e\u003cbr\u003eResponse time is 5 milliseconds including all filtering and isolation delays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eIs this module suitable for safety systems?\u003c\/strong\u003e\u003cbr\u003eWhile robust, it requires appropriate safety certification for safety-critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819027076,"sku":"CC-PDIL01","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PDIL01.jpg?v=1764511582"},{"product_id":"honeywell-cc-paih02-hart-analog-input-module-16-channel","title":"Honeywell CC-PAIH02 HART Analog Input Module | 16-Channel","description":"\u003ch2\u003eHoneywell CC-PAIH02 HART Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIH02\u003c\/strong\u003e provides \u003cstrong style=\"color: #2e86ab;\"\u003ehigh-precision 16-channel analog input\u003c\/strong\u003e with HART protocol support. This versatile module offers \u003cstrong\u003eflexible signal acceptance\u003c\/strong\u003e and \u003cstrong\u003eexceptional noise immunity\u003c\/strong\u003e for accurate process monitoring in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eManufacturer:\u003c\/strong\u003e Honeywell International\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModel Number:\u003c\/strong\u003e CC-PAIH02 HART Analog Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eInput Configuration:\u003c\/strong\u003e 16 total channels (12 single-ended, 4 differential)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eSignal Types:\u003c\/strong\u003e 4-20mA, 1-5V, 0-5V, 0.4-2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eADC Resolution:\u003c\/strong\u003e 16-bit high precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;10 MΩ for voltage inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003ePower Consumption:\u003c\/strong\u003e 60W maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eScan Rate:\u003c\/strong\u003e 50ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eHardware Accuracy:\u003c\/strong\u003e ±0.075% FS at 23.5°C ±2°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eTemperature Accuracy:\u003c\/strong\u003e ±0.15% FS from 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCommon Mode Rejection:\u003c\/strong\u003e 70dB (DC to 60Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eNormal Mode Rejection:\u003c\/strong\u003e 19dB at 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eChannel Crosstalk:\u003c\/strong\u003e -60dB isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eInput Protection:\u003c\/strong\u003e ±30V maximum without damage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCommon Mode Voltage:\u003c\/strong\u003e -6V to +5V peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eFilter Response:\u003c\/strong\u003e Single-pole RC, -3dB @ 6.5Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 19-inch rack mounting\u003c\/li\u003e\n\u003cli\u003e22-28VDC power supply required\u003c\/li\u003e\n\u003cli\u003eShielded twisted pair wiring recommended\u003c\/li\u003e\n\u003cli\u003eProper grounding for noise reduction\u003c\/li\u003e\n\u003cli\u003e250Ω resistor for current input configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Experion PKS control systems\u003c\/li\u003e\n\u003cli\u003eSeries C I\/O architecture platforms\u003c\/li\u003e\n\u003cli\u003eHART protocol compatible field devices\u003c\/li\u003e\n\u003cli\u003eIndustrial Ethernet communication networks\u003c\/li\u003e\n\u003cli\u003eThird-party DCS with appropriate gateways\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed for general safety\u003c\/li\u003e\n\u003cli\u003eCE Marked for European compliance\u003c\/li\u003e\n\u003cli\u003eClass 1 Division 2 non-incendive rating\u003c\/li\u003e\n\u003cli\u003eATEX certified for hazardous areas\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2 standards compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat input signals does the CC-PAIH02 support?\u003c\/strong\u003e\u003cbr\u003eThe module accepts 4-20mA, 1-5V, 0-5V, and 0.4-2V signals with flexible configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eHow many channels are available and in what configuration?\u003c\/strong\u003e\u003cbr\u003e16 total channels with 12 single-ended and 4 differential inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat safety certifications does this module have?\u003c\/strong\u003e\u003cbr\u003eIt carries Class 1 Division 2 non-incendive rating for hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819190916,"sku":"CC-PAIH02","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIH02.jpg?v=1761656517"},{"product_id":"honeywell-cc-taix11-analog-input-redundant-module","title":"Honeywell CC-TAIX11 Analog Input Redundant Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-TAIX11 Analog Input IOTA Redundant Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAIX11\u003c\/strong\u003e provides redundant analog input for process control. This IOTA module ensures reliability with 16-channel input capability.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e CC-TAIX11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Analog Input IOTA Redundant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 0.195 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 12 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.79 lbs (0.358 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.05% full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500 V channel-to-channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does IOTA redundancy provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDual processors and power supplies. Automatic switchover if one fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many devices can connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e16 separate 4-20mA field devices. Each channel is individually isolated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it handle power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintains configuration data. Automatically resumes operation when power returns.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819518596,"sku":"CC-TAIX11","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TAIX11.jpg?v=1770394431"},{"product_id":"cc-paih01-i-o-module-4-20ma-input-honeywell-system","title":"CC-PAIH01 I\/O Module 4-20mA Input Honeywell System","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PAIH01 I\/O Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIH01\u003c\/strong\u003e is an analog input module with integrated field terminations. This module handles multiple signal types for industrial process control.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CC-PAIH01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 total inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Rate:\u003c\/strong\u003e 50 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit A\/D conversion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Input:\u003c\/strong\u003e 0 to 5 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input:\u003c\/strong\u003e 4 to 20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Input Protection:\u003c\/strong\u003e ±30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e 70 dB minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 1.5 W typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Time:\u003c\/strong\u003e 100 ms for all channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 500 VDC channel-to-bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 15 minutes to rated accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e 250,000 hours minimum\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819551364,"sku":"CC-PAIH01","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIH01.jpg?v=1770394244"},{"product_id":"honeywell-cc-pcf901-network-security-module","title":"Honeywell CC-PCF901 Network Security Module","description":"\u003ch2\u003eHoneywell CC-PCF901 Control Firewall Module\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eCC-PCF901\u003c\/strong\u003e is a control firewall module. It provides network security for industrial control systems.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Honeywell \u003cstrong\u003eCC-PCF901\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Control Firewall Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 6.4\" × 6.4\" × 4.8\" (16 × 16 × 12 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.25 Kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Material:\u003c\/strong\u003e Ruggedized aluminum casing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 10 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Speed:\u003c\/strong\u003e 400 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Throughput:\u003c\/strong\u003e Up to 1 Gbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog Capacity:\u003c\/strong\u003e 100,000 entries storage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 5g peak (20-500 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30g peak for 11 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVPN Support:\u003c\/strong\u003e IPsec and SSL VPN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400 MHz processor for fast processing\u003c\/li\u003e\n\u003cli\u003eHigh 1 Gbps data throughput\u003c\/li\u003e\n\u003cli\u003eIPsec and SSL VPN security support\u003c\/li\u003e\n\u003cli\u003e100,000 log entries storage capacity\u003c\/li\u003e\n\u003cli\u003eRuggedized aluminum casing for durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial control system network security\u003c\/li\u003e\n\u003cli\u003eProcess automation network protection\u003c\/li\u003e\n\u003cli\u003eSCADA system security implementation\u003c\/li\u003e\n\u003cli\u003eManufacturing network security\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePerformance Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast 400 MHz processing speed\u003c\/li\u003e\n\u003cli\u003eHigh 1 Gbps data throughput\u003c\/li\u003e\n\u003cli\u003eLow 10 W power consumption\u003c\/li\u003e\n\u003cli\u003eExtreme temperature operation capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the data throughput capacity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e \u003cstrong\u003eCC-PCF901\u003c\/strong\u003e supports up to 1 Gbps throughput.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What VPN protocols are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e IPsec and SSL VPN protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F).\u003c\/p\u003e\n\u003cp\u003eFor support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003eContact Engineering Team\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819616900,"sku":"CC-PCF901","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PCF901.jpg?v=1770385057"},{"product_id":"honeywell-cc-taid11-differential-analog-input-iota-module","title":"Honeywell CC-TAID11 Differential Analog Input IOTA Module","description":"\u003ch2\u003eHoneywell CC-TAID11 Differential Analog Input IOTA Module\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eCC-TAID11\u003c\/strong\u003e is a differential analog input IOTA module. It provides precise measurement for industrial process control.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Honeywell \u003cstrong\u003eCC-TAID11\u003c\/strong\u003e IOTA Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Differential Analog Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 4 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types:\u003c\/strong\u003e Voltage (-10V to +10V) \/ Current (4-20mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 24 VDC ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 1.5 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e HART, MODBUS protocols\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e RS-485 \/ 2-Wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -40°F to +185°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 110 × 80 × 45 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate body\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Ground fault and surge protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.42 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4-channel differential analog input\u003c\/li\u003e\n\u003cli\u003eDual voltage\/current input capability\u003c\/li\u003e\n\u003cli\u003eHART and MODBUS communication support\u003c\/li\u003e\n\u003cli\u003eBuilt-in ground fault and surge protection\u003c\/li\u003e\n\u003cli\u003eFactory calibrated for accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial process measurement systems\u003c\/li\u003e\n\u003cli\u003eAnalog signal acquisition applications\u003c\/li\u003e\n\u003cli\u003eHoneywell control system integration\u003c\/li\u003e\n\u003cli\u003eProcess variable monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input: -10V to +10V range\u003c\/li\u003e\n\u003cli\u003eCurrent input: 4-20mA standard\u003c\/li\u003e\n\u003cli\u003e24 VDC ±10% power supply\u003c\/li\u003e\n\u003cli\u003eLow 1.5 W power consumption\u003c\/li\u003e\n\u003cli\u003eRS-485 communication interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackaging \u0026amp; Shipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003eCC-TAID11\u003c\/strong\u003e IOTA module\u003c\/li\u003e\n\u003cli\u003eInstallation documentation\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eShipped via major global carriers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many input channels does this module have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e \u003cstrong\u003eCC-TAID11\u003c\/strong\u003e provides 4 differential analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocols are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e HART and MODBUS protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the input voltage range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e -10V to +10V voltage input range.\u003c\/p\u003e\n\u003cp\u003eFor support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003eContact Engineering Team\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819649668,"sku":"CC-TAID11","price":247.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TAID11.jpg?v=1770384814"},{"product_id":"cc-paix02-honeywell-high-level-analog-input-module","title":"CC-PAIX02 Honeywell | High Level Analog Input Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PAIX02 High Level Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eCC-PAIX02\u003c\/strong\u003e from Honeywell delivers high-performance analog signal acquisition for process control systems. This high level analog input module provides precise measurement capabilities for various industrial signals. With immediate availability and reliable performance, it serves as a key component in Honeywell's control system architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e CC-PAIX02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePart Number:\u003c\/strong\u003e CC-PAIX02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e High Level Analog Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eNumber of Channels:\u003c\/strong\u003e 16 single-ended or 8 differential\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Signals:\u003c\/strong\u003e 4-20mA, 0-20mA, 0-5V, 0-10V, ±5V, ±10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eResolution:\u003c\/strong\u003e 16-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eUpdate Rate:\u003c\/strong\u003e 50 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Impedance:\u003c\/strong\u003e 1MΩ voltage, 250Ω current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCommon Mode Rejection:\u003c\/strong\u003e \u0026gt;100 dB at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eNormal Mode Rejection:\u003c\/strong\u003e \u0026gt;60 dB at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eIsolation:\u003c\/strong\u003e 500V channel to bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePower Consumption:\u003c\/strong\u003e 5VDC @ 900mA, 24VDC @ 120mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eConnection:\u003c\/strong\u003e Removable screw terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eLED Indicators:\u003c\/strong\u003e Power, status, channel activity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.35 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eLead Time:\u003c\/strong\u003e 2-3 Working Days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh 1MΩ input impedance minimizes voltage signal loading\u003c\/li\u003e\n\u003cli\u003e250Ω precision resistor for accurate current loop measurement\u003c\/li\u003e\n\u003cli\u003e\u0026gt;100dB common mode rejection eliminates ground loop interference\u003c\/li\u003e\n\u003cli\u003e\u0026gt;60dB normal mode rejection filters line frequency noise\u003c\/li\u003e\n\u003cli\u003e500V isolation protects system from field-side transients\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat signals does this module accept?\u003c\/strong\u003e 4-20mA, 0-10V, ±10V and other standard industrial signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many channels are available?\u003c\/strong\u003e 16 single-ended or 8 differential input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the typical delivery time?\u003c\/strong\u003e Usually ships within 7-10 working days.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51351638638724,"sku":"CC-PAIX02","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIX02.jpg?v=1764511775"},{"product_id":"honeywell-cc-paon01-4-20ma-output-module-8-channels","title":"Honeywell CC-PAON01 4-20mA Output Module 8 Channels","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PAON01 Analog Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eCC-PAON01\u003c\/strong\u003e from Honeywell provides high-precision analog output capability for process control applications. This analog output module delivers accurate control signals to field devices with multiple output ranges. Supplied as new and original in factory packaging, it includes a comprehensive 12-month manufacturer warranty for reliable long-term operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e CC-PAON01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePart Number:\u003c\/strong\u003e CC-PAON01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e Analog Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWarranty:\u003c\/strong\u003e 12 Months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eNumber of Channels:\u003c\/strong\u003e 8 independent outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOutput Signals:\u003c\/strong\u003e 4-20mA, 0-20mA, 0-5V, 0-10V, ±5V, ±10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eResolution:\u003c\/strong\u003e 16-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eUpdate Rate:\u003c\/strong\u003e 25 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eAccuracy:\u003c\/strong\u003e ±0.05% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eLoad Capacity:\u003c\/strong\u003e 0-900Ω (current), 2kΩ min (voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOutput Noise:\u003c\/strong\u003e \u0026lt;10 μV RMS (voltage), \u0026lt;0.1 μA RMS (current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eIsolation:\u003c\/strong\u003e 500V channel to channel, 1500V channel to ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSettling Time:\u003c\/strong\u003e 1 ms to 0.01% for full scale step\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePower Supply:\u003c\/strong\u003e 24VDC ±10%, 500mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBackplane Current:\u003c\/strong\u003e 5VDC @ 750mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eConnection:\u003c\/strong\u003e Removable terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eStatus Indicators:\u003c\/strong\u003e Per channel status, module health\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eLead Time:\u003c\/strong\u003e 2-3 Working Days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16-bit resolution delivers precise analog control signals\u003c\/li\u003e\n\u003cli\u003e±0.05% full scale accuracy ensures exact process control\u003c\/li\u003e\n\u003cli\u003eFast 25ms update rate per channel provides responsive control\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51351639588996,"sku":"CC-PAON01","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAON01.jpg?v=1764512066"},{"product_id":"honeywell-hart-ao-module-cc-paox01","title":"Honeywell HART AO Module CC-PAOX01","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PAOX01 HART Analog Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eCC-PAOX01\u003c\/strong\u003e from Honeywell combines precise analog output control with HART communication protocol capability. This advanced module provides both 4-20mA control signals and digital HART communication for smart field devices. Supplied as new original equipment in factory packaging, it includes full 12-month manufacturer warranty protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e CC-PAOX01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePart Number:\u003c\/strong\u003e CC-PAOX01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e HART Analog Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCondition:\u003c\/strong\u003e New \u0026amp; Original in Factory Packing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWarranty:\u003c\/strong\u003e 12 Months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eNumber of Channels:\u003c\/strong\u003e 8 independent HART outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOutput Signal:\u003c\/strong\u003e 4-20mA with HART protocol overlay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eHART Version:\u003c\/strong\u003e HART 7 compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eResolution:\u003c\/strong\u003e 16-bit analog, HART digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eAccuracy:\u003c\/strong\u003e ±0.05% of span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eUpdate Rate:\u003c\/strong\u003e 4 updates per second per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eLoad Capacity:\u003c\/strong\u003e 250-750 ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eHART Burst Mode:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eIsolation:\u003c\/strong\u003e 500V channel to channel, 1500V to ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePower Supply:\u003c\/strong\u003e 24VDC ±15%, 600mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eConnection:\u003c\/strong\u003e Removable screw terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDiagnostics:\u003c\/strong\u003e HART device status, loop current, communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.38 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 independent channels provide flexible control system configuration\u003c\/li\u003e\n\u003cli\u003e16-bit resolution delivers precise analog control signal generation\u003c\/li\u003e\n\u003cli\u003e±0.05% accuracy ensures exact process control performance\u003c\/li\u003e\n\u003cli\u003e4 updates per second rate supports responsive control applications\u003c\/li\u003e\n\u003cli\u003e250-750 ohm load range accommodates various field device requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat HART version is supported?\u003c\/strong\u003e HART 7 protocol compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many output channels are available?\u003c\/strong\u003e 8 independent HART analog output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat warranty is provided?\u003c\/strong\u003e 12-month manufacturer warranty on new equipment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51351646961796,"sku":"CC-PAOX01","price":211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAOX01-1.jpg?v=1764512944"},{"product_id":"honeywell-cc-pfb801-fieldbus-interface-module","title":"Honeywell CC-PFB801 Fieldbus Interface Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PFB801 Fieldbus Interface Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PFB801\u003c\/strong\u003e is a Fieldbus Interface Module designed for industrial control systems. This module provides the physical interface for H1 FOUNDATION Fieldbus communication networks with robust technical specifications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eHoneywell\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eCC-PFB801\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fieldbus Interface Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Type:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eH1 FOUNDATION Fieldbus\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e31.25 kbps\u003c\/strong\u003e standard fieldbus speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Levels:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e±15V\u003c\/strong\u003e differential signaling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Topology:\u003c\/strong\u003e Supports bus, tree, and point-to-point topologies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e Maximum \u003cstrong style=\"color: #2c5aa0;\"\u003e1900 meters\u003c\/strong\u003e per segment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Support:\u003c\/strong\u003e Up to \u003cstrong style=\"color: #2c5aa0;\"\u003e32 devices\u003c\/strong\u003e per segment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e24V DC\u003c\/strong\u003e typical fieldbus power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Built-in \u003cstrong style=\"color: #2c5aa0;\"\u003e100Ω\u003c\/strong\u003e termination resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e500V AC\u003c\/strong\u003e field-to-system isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat type of fieldbus does it support?\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eH1 FOUNDATION Fieldbus\u003c\/strong\u003e interface at 31.25 kbps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many devices can connect?\u003c\/strong\u003e Supports up to \u003cstrong style=\"color: #2c5aa0;\"\u003e32 devices\u003c\/strong\u003e per network segment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable length?\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e1900 meters\u003c\/strong\u003e maximum per segment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51368596406404,"sku":"CC-PFB801","price":232.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PFB801.jpg?v=1765025417"},{"product_id":"cc-ppix01-pulse-input-module-honeywell","title":"CC-PPIX01 Pulse Input Module | Honeywell","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PPIX01 Pulse Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PPIX01\u003c\/strong\u003e is a professional Pulse Input Module for industrial control systems. This 100% original module is manufactured in the USA and comes with complete original packaging.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eHoneywell\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eCC-PPIX01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Pulse Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e1 Year\u003c\/strong\u003e manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e16 channels\u003c\/strong\u003e pulse input capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Frequency:\u003c\/strong\u003e Up to \u003cstrong style=\"color: #2c5aa0;\"\u003e10 kHz\u003c\/strong\u003e maximum frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e24V DC\u003c\/strong\u003e standard industrial voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e4-20 mA\u003c\/strong\u003e signal range support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e500V AC\u003c\/strong\u003e channel-to-system isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e±0.1%\u003c\/strong\u003e of reading measurement accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e100 ms\u003c\/strong\u003e data update period\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e-20°C to 70°C\u003c\/strong\u003e range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eQuality \u0026amp; Packaging\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality:\u003c\/strong\u003e 100% Original, 100% Brand New\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage:\u003c\/strong\u003e Complete original factory packaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMOQ:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e1 set\u003c\/strong\u003e minimum order quantity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere is it manufactured?\u003c\/strong\u003e Made in the \u003cstrong style=\"color: #2c5aa0;\"\u003eUnited States of America\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the warranty period?\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e1 Year\u003c\/strong\u003e manufacturer warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many input channels?\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e16 channels\u003c\/strong\u003e for pulse input.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51368674656388,"sku":"CC-PPIX01","price":224.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PPIX01.jpg?v=1765028740"},{"product_id":"cc-paix01-analog-input-module-honeywell","title":"CC-PAIX01 Analog Input Module | Honeywell","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PAIX01 Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIX01\u003c\/strong\u003e is a professional Analog Input Module for industrial control systems. This module, part number 51405038-275, is new and original in factory packing with full warranty.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eHoneywell\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eCC-PAIX01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e51405038-275\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eNew \u0026amp; Original\u003c\/strong\u003e in Factory Packing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e12 Months\u003c\/strong\u003e Factory Warranty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003eIn Stock\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e16 channels\u003c\/strong\u003e analog input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e4-20 mA\u003c\/strong\u003e standard current loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e1-5V DC\u003c\/strong\u003e voltage input option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e±0.1%\u003c\/strong\u003e of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e16-bit\u003c\/strong\u003e analog-to-digital conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e50 ms\u003c\/strong\u003e per channel scan time\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e1500V AC\u003c\/strong\u003e channel-to-channel isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e-40°C to 85°C\u003c\/strong\u003e industrial range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e250 mA\u003c\/strong\u003e maximum at 24V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy 16-bit A\/D conversion for precise measurements\u003c\/li\u003e\n\u003cli\u003eSupports both current (4-20mA) and voltage (1-5V) inputs\u003c\/li\u003e\n\u003cli\u003e1500V AC isolation for noise immunity and safety\u003c\/li\u003e\n\u003cli\u003eFast 50ms per channel scan time for real-time monitoring\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range from -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the part number?\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e51405038-275\u003c\/strong\u003e is the official part number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many input channels?\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e16 channels\u003c\/strong\u003e of analog input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat warranty is provided?\u003c\/strong\u003e \u003cstrong style=\"color: #2c5aa0;\"\u003e12-month\u003c\/strong\u003e factory warranty included.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51368693399684,"sku":"CC-PAIX01","price":224.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIX01-4.jpg?v=1765029618"},{"product_id":"honeywell-cc-pain01-analog-input-module","title":"Honeywell CC-PAIN01 Analog Input Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PAIN01 Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003eHoneywell CC-PAIN01\u003c\/strong\u003e module connects your control system to field devices. It accurately reads 4-20 mA current signals from industrial sensors and transmitters.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003eHoneywell\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003eCC-PAIN01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e 4-20 mA Current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e 2-Wire \u0026amp; Self-Powered Transmitters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature:\u003c\/strong\u003e Supplies Field Power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.35 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMain Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFast loop scanning for real-time data\u003c\/li\u003e\n\u003cli\u003eBuilt-in self-diagnostics for reliability\u003c\/li\u003e\n\u003cli\u003eOptional redundancy for critical applications\u003c\/li\u003e\n\u003cli\u003eHigh noise immunity for stable operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the CC-PAIN01?\u003c\/strong\u003e It is a Honeywell module that reads 4-20mA signals from field instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan it power transmitters?\u003c\/strong\u003e Yes, it provides power for 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs it reliable?\u003c\/strong\u003e Yes, with continuous self-diagnostics and optional redundancy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51369367961732,"sku":"CC-PAIN01","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIN01.jpg?v=1765080580"},{"product_id":"cc-paim01-honeywell-low-level-analog-input","title":"CC-PAIM01 Honeywell Low Level Analog Input","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PAIM01 Low Level Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003eHoneywell CC-PAIM01\u003c\/strong\u003e is a precision low-level analog input module. It measures small voltage signals from sensitive instruments with high accuracy. This Honeywell module is available In Stock for fast delivery.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003eCC-PAIM01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Low Level Analog Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Ranges:\u003c\/strong\u003e ±50 mV, ±1 V, ±5 V, ±10 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.05% of Full Scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 10 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e \u0026gt;120 dB at 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;1 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Isolation:\u003c\/strong\u003e 500 Vrms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh 16-bit resolution for precise signal measurement\u003c\/li\u003e\n\u003cli\u003eMultiple voltage ranges for application flexibility\u003c\/li\u003e\n\u003cli\u003eExcellent noise rejection for stable operation\u003c\/li\u003e\n\u003cli\u003eWide temperature range for industrial environments\u003c\/li\u003e\n\u003cli\u003eBuilt-in diagnostics for continuous health monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat signals does the CC-PAIM01 measure?\u003c\/strong\u003e It measures low-level voltage signals from ±50 mV up to ±10 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the accuracy of this module?\u003c\/strong\u003e The module offers high accuracy of ±0.05% of full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs it suitable for noisy environments?\u003c\/strong\u003e Yes, it features excellent noise rejection greater than 120 dB.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51369369796740,"sku":"CC-PAIM01","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIM01.jpg?v=1765081096"},{"product_id":"cc-taix01-honeywell-analog-input-module","title":"CC-TAIX01 Honeywell Analog Input Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-TAIX01 Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003eHoneywell CC-TAIX01\u003c\/strong\u003e is a versatile analog input module. It accurately reads both voltage and current signals from your field instruments. This module ensures reliable data acquisition for industrial control and monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003eCC-TAIX01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 0.320 A @ 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e 2.464 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Types:\u003c\/strong\u003e Voltage and Current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Ranges:\u003c\/strong\u003e 0-10V DC and 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e High precision of ±0.1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24V DC Standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Operating Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% (Non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical Application:\u003c\/strong\u003e Process variable monitoring and data acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Feature:\u003c\/strong\u003e Supports both common industrial signal types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat signals does the CC-TAIX01 accept?\u003c\/strong\u003e It accepts both 0-10V voltage signals and 4-20mA current signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the accuracy of this module?\u003c\/strong\u003e The module provides high accuracy of ±0.1%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat power supply does it need?\u003c\/strong\u003e It requires a standard 24V DC power supply.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51369372483716,"sku":"CC-TAIX01","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TAIX01-4.jpg?v=1765082846"},{"product_id":"honeywell-cc-paih51-analog-input-hart-module-16-channel","title":"Honeywell CC-PAIH51 Analog Input HART Module | 16-Channel","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-PAIH51 Analog Input Module with HART\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eCC-PAIH51\u003c\/strong\u003e is a 16-channel analog input module. It supports HART protocol for smart device communication. This module handles 4-20mA current signals with high precision. It's designed for reliable process monitoring in industrial control systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003eCC-PAIH51\u003c\/strong\u003e - High-Level Analog Input with HART\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e 4-20mA Current (2-wire or self-powered)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 single-ended inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16 bits A\/D converter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.075% FS (@23.5°±2°C), ±0.15% FS (0-60°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Rate:\u003c\/strong\u003e 50 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMRR:\u003c\/strong\u003e 70 dB (dc to 60 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 200 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Range:\u003c\/strong\u003e 4-20mA only (through 200Ω resistor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Rejection:\u003c\/strong\u003e 19 dB NMRR at 60 Hz, -60 dB crosstalk\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter:\u003c\/strong\u003e Single-pole RC, -3dB @ 6.5 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Input:\u003c\/strong\u003e ±30V normal mode protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMV Range:\u003c\/strong\u003e -6 to +5V peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Models:\u003c\/strong\u003e \u003cstrong\u003eCC-TAIX51\u003c\/strong\u003e (6\" non-redundant), \u003cstrong\u003eCC-TAIX61\u003c\/strong\u003e (12\" redundant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstalls into compatible Honeywell IOTA carriers\u003c\/li\u003e\n\u003cli\u003eSupports HART digital communication over 4-20mA signal\u003c\/li\u003e\n\u003cli\u003e\u003cstrong style=\"color: #27ae60;\"\u003eTerminal blocks and carriers sold separately\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eFollow plant wiring standards for noise reduction\u003c\/li\u003e\n\u003cli\u003eConfigure via system software for scaling and addressing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes: 1x \u003cstrong\u003eCC-PAIH51\u003c\/strong\u003e analog input module\u003c\/li\u003e\n\u003cli\u003eCarrier and accessories sold separately\u003c\/li\u003e\n\u003cli\u003eShipped via \u003cstrong style=\"color: #2980b9;\"\u003eFedEx, UPS, or DHL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSecure packaging ensures safe delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the HART protocol advantage?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe HART protocol enables digital communication with smart devices. It allows configuration and diagnostics without interrupting the 4-20mA signal on the \u003cstrong\u003eCC-PAIH51\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it accept voltage signals?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo. The \u003cstrong\u003eCC-PAIH51\u003c\/strong\u003e is designed for \u003cstrong\u003e4-20mA current signals only\u003c\/strong\u003e. Use different Honeywell modules for voltage inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does single-ended input mean?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAll 16 channels share a common ground reference. This is standard for 4-20mA loops but requires proper grounding to minimize noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51444042563716,"sku":"CC-PAIH51","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIH51-1.jpg?v=1767795994"},{"product_id":"honeywell-cc-pwrr01-redundant-power-module-control-systems","title":"Honeywell CC-PWRR01 Redundant Power Module Control Systems","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell Redundant Power Supply CC-PWRR01\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eCC-PWRR01\u003c\/strong\u003e is a redundant power supply module. It provides backup power to prevent system downtime during power failures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eCC-PWRR01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Redundant Power Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120\/240V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e System backplane voltage (e.g., 5V\/24V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitchover Time:\u003c\/strong\u003e \u0026lt;20 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e High-efficiency design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic failover during power loss\u003c\/li\u003e\n\u003cli\u003eHot-swap capable for maintenance\u003c\/li\u003e\n\u003cli\u003eVisual status indicators (LEDs)\u003c\/li\u003e\n\u003cli\u003eLoad-sharing operation\u003c\/li\u003e\n\u003cli\u003eDesigned for Honeywell control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor Honeywell system chassis\u003c\/li\u003e\n\u003cli\u003eMounts in dedicated power slot\u003c\/li\u003e\n\u003cli\u003eRequires independent AC power sources\u003c\/li\u003e\n\u003cli\u003eUse in paired configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x CC-PWRR01 power supply module\u003c\/li\u003e\n\u003cli\u003eSecure protective packaging\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does this module do?\u003c\/strong\u003e\u003cbr\u003eProvides backup power to keep systems running if the main power supply fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs hot-swap supported?\u003c\/strong\u003e\u003cbr\u003eYes, designed for hot-swap in supported systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow to wire for true redundancy?\u003c\/strong\u003e\u003cbr\u003eConnect each unit to separate AC power circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51444046626948,"sku":"CC-PWRR01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PWRR0151199929-1003.jpg?v=1767796199"},{"product_id":"digital-output-module-honeywell-cc-td0b11-tdc-systems","title":"Digital Output Module | Honeywell CC-TD0B11 TDC Systems","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell Digital Output Module CC-TD0B11\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eCC-TD0B11\u003c\/strong\u003e is a digital output module for TDC\/Experion systems. It provides reliable on\/off control for field devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eCC-TD0B11\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 16 points (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24V DC (external field supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current per Point:\u003c\/strong\u003e 2A max continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop:\u003c\/strong\u003e \u0026lt;1.5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Leakage:\u003c\/strong\u003e \u0026lt;0.1 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Time:\u003c\/strong\u003e \u0026lt;10 ms per scan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500V channel-to-system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 independent output channels\u003c\/li\u003e\n\u003cli\u003eSupports 24V DC field devices\u003c\/li\u003e\n\u003cli\u003eIndividual channel diagnostics\u003c\/li\u003e\n\u003cli\u003eHot-swap capable\u003c\/li\u003e\n\u003cli\u003eFront-panel status LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor TDC\/Experion I\/O chassis\u003c\/li\u003e\n\u003cli\u003eRemovable terminal blocks\u003c\/li\u003e\n\u003cli\u003eRequires external 24V DC field power\u003c\/li\u003e\n\u003cli\u003eConfigure via control system software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x CC-TD0B11 module\u003c\/li\u003e\n\u003cli\u003eSecure packaging\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat field devices can it control?\u003c\/strong\u003e\u003cbr\u003eSolenoid valves, relays, motor starters, indicators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many channels does it have?\u003c\/strong\u003e\u003cbr\u003e16 independent output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs isolation provided?\u003c\/strong\u003e\u003cbr\u003eYes, 500V isolation between channels and system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51444080509060,"sku":"CC-TD0B11","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TDOB11.jpg?v=1767796968"},{"product_id":"high-voltage-input-module-honeywell-cc-tdi220-16-channel","title":"High Voltage Input Module | Honeywell CC-TDI220 16-Channel","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell 16-Channel High Voltage Digital Input Module CC-TDI220\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong style=\"color: #2e74b5;\"\u003eCC-TDI220\u003c\/strong\u003e is a robust 16-channel digital input module for high-voltage applications. Designed for the Experion Series-C DCS, it reliably monitors 120V AC or DC field signals from devices like proximity switches. Its wide operating temperature range makes it suitable for demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong style=\"color: #2e74b5;\"\u003eCC-TDI220\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e High Voltage Digital Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Experion Series-C DCS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 16 Channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 90-132 V AC RMS \/ 100-138 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 120V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN Rail or Panel Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Honeywell \u003cstrong\u003eCC-TDI220\u003c\/strong\u003e digital input module.\u003c\/li\u003e\n\u003cli\u003eFactory packaging ensuring protection.\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat types of devices can connect to this module?\u003c\/strong\u003e\u003cbr\u003eIt is designed for 120V AC or DC discrete signals from devices like proximity switches, limit switches, selector switches, and relay contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan it be used with lower voltage signals (e.g., 24V DC)?\u003c\/strong\u003e\u003cbr\u003eNo, it is specifically designed for high-voltage inputs. For lower voltages, a different module from the series should be used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eWithin the Experion Series-C system architecture, I\/O modules typically support hot-swapping, but refer to system documentation for specific procedures and cautions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51444085391492,"sku":"CC-TDI220","price":193.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TDI220-1.jpg?v=1767797148"},{"product_id":"cc-taim01-honeywell-low-level-analog-input-module","title":"CC-TAIM01 Honeywell Low Level Analog Input Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell CC-TAIM01 Low-Level Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAIM01\u003c\/strong\u003e is a high-precision analog input module designed for accurate measurement of low-level signals. It is ideally suited for connecting temperature sensors like RTDs and thermocouples, as well as other millivolt sources, in demanding process control applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell, \u003cstrong style=\"color: #d35400;\"\u003eCC-TAIM01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003eLow-Level Analog Input Module\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e \u003cstrong style=\"color: #27ae60;\"\u003eIn Stock\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Types:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003eRTD (Pt100, Pt1000), Thermocouple (J, K, T, E, etc.), mV (0-100mV), mA (0-20mA)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e16-bit\u003c\/strong\u003e analog-to-digital conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e±0.05%\u003c\/strong\u003e of reading for RTD\/mA; \u003cstrong style=\"color: #2c3e50;\"\u003e±0.5°C\u003c\/strong\u003e for thermocouple\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e\u0026gt; 10 MΩ\u003c\/strong\u003e (voltage inputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e\u0026gt; 120 dB\u003c\/strong\u003e at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e4 conversions per second\u003c\/strong\u003e per channel (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003eIntegrated\u003c\/strong\u003e for thermocouple inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e250 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Packaging\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Install the \u003cstrong\u003eCC-TAIM01\u003c\/strong\u003e module in its designated slot on the system rack. Connect field sensor wiring (using appropriate 2, 3, or 4-wire connections for RTDs) to the module's front terminals, ensuring correct polarity for thermocouples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Each \u003cstrong\u003eCC-TAIM01\u003c\/strong\u003e module ships individually. We ship via reliable carriers such as FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What types of temperature sensors does this module support?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eCC-TAIM01\u003c\/strong\u003e supports a wide range, including \u003cstrong\u003e2, 3, or 4-wire RTDs\u003c\/strong\u003e (like Pt100) and various \u003cstrong\u003ethermocouple types\u003c\/strong\u003e (J, K, T, E, N, R, S, B). Each channel is software-configurable for the specific sensor type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is cold junction compensation and why is it important?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Cold junction compensation (CJC) automatically measures and corrects for the temperature at the module's terminal block where the thermocouple wires connect. This is \u003cstrong\u003ecritical for thermocouple accuracy\u003c\/strong\u003e, as the voltage they generate depends on the temperature difference between the measuring and reference (cold) junctions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I mix RTD and thermocouple inputs on the same module?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Yes, the \u003cstrong\u003eCC-TAIM01\u003c\/strong\u003e is a universal analog input. Each of its channels can be independently configured for a different sensor type (RTD, TC, mV, or mA), providing maximum application flexibility from a single module.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51445962997892,"sku":"CC-TAIM01","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TAIM01.jpg?v=1767880865"},{"product_id":"honeywell-dc-tfb412-i-o-module-24vdc-digital","title":"Honeywell DC-TFB412 I\/O Module | 24VDC Digital","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell DC-TFB412 Digital Input\/Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell DC-TFB412\u003c\/strong\u003e is a compact and efficient digital I\/O module providing 32 channels of interface capability. It features balanced 16-input and 16-output channels in a space-saving design, making it ideal for medium-density discrete control applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell, \u003cstrong style=\"color: #d35400;\"\u003eDC-TFB412\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e10 cm (H) x 18 cm (W) x 10 cm (D)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e0.5 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e16\u003c\/strong\u003e channels, 24 VDC sourcing\/sinking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e16\u003c\/strong\u003e channels, transistor outputs, \u003cstrong style=\"color: #2c3e50;\"\u003e0.5 A\u003c\/strong\u003e per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e24 VDC\u003c\/strong\u003e nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e10 Watts\u003c\/strong\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e0°C to 60°C\u003c\/strong\u003e (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e-40°C to 85°C\u003c\/strong\u003e (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e5% to 95%\u003c\/strong\u003e non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e500 Vrms\u003c\/strong\u003e (field to logic)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e≤ 10 ms\u003c\/strong\u003e for all channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Packaging\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Mount the \u003cstrong\u003eDC-TFB412\u003c\/strong\u003e module on a standard DIN rail within your control panel. Connect the 24VDC power and field wiring to the clearly marked terminal blocks. Ensure the output load does not exceed the 0.5A per point rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Each \u003cstrong\u003eDC-TFB412\u003c\/strong\u003e module ships individually with installation documentation. We ship via reliable carriers such as FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What types of devices can connect to the inputs and outputs?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e16 inputs\u003c\/strong\u003e can connect to dry contacts (switches) or solid-state devices like proximity sensors. The \u003cstrong\u003e16 outputs\u003c\/strong\u003e are suitable for driving relays, solenoid valves, pilot lights, and other DC loads up to 0.5A each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the advantage of the compact 10x18x10 cm size?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; The compact dimensions of the \u003cstrong\u003eDC-TFB412\u003c\/strong\u003e allow for high-density installations in control cabinets where space is limited. You can fit more I\/O points in a smaller footprint, optimizing panel layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this module support diagnostic status indicators?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Yes, the \u003cstrong\u003eDC-TFB412\u003c\/strong\u003e typically includes LED status indicators for each channel (showing ON\/OFF state) and for module health (power, communication). This facilitates quick troubleshooting and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51446195945604,"sku":"DC-TFB412","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DC-TFB412-2.jpg?v=1767881644"},{"product_id":"honeywell-dc-pdod51-digital-output-module","title":"Honeywell DC-PDOD51 Digital Output Module","description":"\u003ch2\u003eHoneywell DC-PDOD51: Compact Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell DC-PDOD51\u003c\/strong\u003e provides reliable digital switching for industrial systems. This \u003cstrong\u003edigital output module\u003c\/strong\u003e delivers 8 channels with short-circuit protection. \u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eBrand:\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eModel:\u003c\/span\u003e DC-PDOD51\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOutputs:\u003c\/span\u003e 8 channels, 24V DC, 0.5A per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eProtection:\u003c\/span\u003e Per-channel short-circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIsolation:\u003c\/span\u003e 1500V AC field-to-logic isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTemperature:\u003c\/span\u003e -40°C to +70°C operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eSwitching:\u003c\/span\u003e 100 Hz max for resistive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eNoise Immunity:\u003c\/span\u003e High EMC compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount \u003cstrong\u003eDC-PDOD51\u003c\/strong\u003e on standard DIN rail\u003c\/li\u003e\n\u003cli\u003eUse removable terminal blocks for wiring\u003c\/li\u003e\n\u003cli\u003eModule auto-configures with backplane\u003c\/li\u003e\n\u003cli\u003eLED indicators show output status\u003c\/li\u003e\n\u003cli\u003ePowered via backplane or external 24V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x Honeywell \u003cstrong\u003eDC-PDOD51\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003e1x Removable terminal block\u003c\/li\u003e\n\u003cli\u003e1x Quick start guide\u003c\/li\u003e\n\u003cli\u003eAnti-static protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the DC-PDOD51 drive inductive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, but use external snubber diodes for loads above 0.5A to protect the outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What cable length works best?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Keep field wiring under 300 meters. Use shielded cable in noisy environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this compatible with my Honeywell system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003eDC-PDOD51\u003c\/strong\u003e works with most Honeywell series. Check your backplane compatibility.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573132394628,"sku":"DC-PDOD51","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DC-PDOD51.jpg?v=1772345403"},{"product_id":"cc-psp401-overspeed-relay-honeywell","title":"CC-PSP401 Overspeed Relay Honeywell","description":"\u003ch2\u003eHoneywell CC-PSP401: Machinery Overspeed Safety\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PSP401\u003c\/strong\u003e acts as a safety watchdog for critical rotating assets. This speed protection module continuously compares turbine or compressor speed against four independent setpoints.\u003c\/p\u003e\n\u003ch2\u003eCore Protection Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc3300;\"\u003eTrip Response:\u003c\/span\u003e \u0026lt;50ms from overspeed detection to relay change\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc3300;\"\u003eSetpoints:\u003c\/span\u003e 4 programmable levels per channel (alert, danger, start, stop)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc3300;\"\u003eRedundancy:\u003c\/span\u003e Dual independent processing channels on one module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc3300;\"\u003eOutputs:\u003c\/span\u003e 4 Form-C relays (dry contacts, 5A rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc3300;\"\u003eAnalog Output:\u003c\/span\u003e Live 4-20mA speed retransmission for DCS trending\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSensor Input Flexibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMagnetic Pickups:\u003c\/span\u003e Direct connection, no external signal conditioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eProximity Probes:\u003c\/span\u003e Accepts eddy current types (3300, 7200 series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eHall Effect:\u003c\/span\u003e 3-wire digital or analog sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eFrequency Range:\u003c\/span\u003e 0.1 Hz to 20 kHz covers low-speed turning gear to high-speed turbines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental \u0026amp; Physical\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTemperature:\u003c\/span\u003e -40°C to +70°C (suitable for turbine decks)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eVibration:\u003c\/span\u003e Certified to IEC 60068-2-6 for rotating machinery areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIsolation:\u003c\/span\u003e 1500V between field inputs and logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWeight:\u003c\/span\u003e 1.2kg (3.3 lbs) rugged construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWarranty:\u003c\/span\u003e 12 months factory, new in original Honeywell packing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CC-PSP401 replace an existing mechanical bolt sensor system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Many users replace mechanical systems with the \u003cstrong\u003eCC-PSP401\u003c\/strong\u003e. It provides faster response and self-diagnostics. You keep existing magnetic pickups; the module interfaces directly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I set different trip speeds for startup and run modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Use two setpoints per channel. Assign one for startup overspeed (typically higher tolerance) and another for normal operation. The module switches automatically based on speed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module log the speed at which a trip occurred?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The \u003cstrong\u003eCC-PSP401\u003c\/strong\u003e captures the exact speed that caused the trip in non-volatile memory. Maintenance can retrieve this data later for root cause analysis.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573151793284,"sku":"CC-PSP401","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PSP401.jpg?v=1772349495"},{"product_id":"profibus-dp-gateway-cc-ip0101-honeywell","title":"Profibus DP Gateway CC-IP0101 Honeywell","description":"\u003ch2\u003eHoneywell CC-IP0101: Profibus DP Gateway Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-IP0101\u003c\/strong\u003e Profibus DP Gateway connects Profibus field devices to Honeywell control systems. This gateway module enables seamless communication between Profibus networks and Experion platforms.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eBrand:\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eModel:\u003c\/span\u003e CC-IP0101\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOrder Code:\u003c\/span\u003e 51410056-175\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eType:\u003c\/span\u003e Profibus DP \u003cspan\u003eGateway \u003c\/span\u003eModule\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eProtocol:\u003c\/span\u003e Profibus DP master\/slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eBaud Rates:\u003c\/span\u003e 9.6 kbps to 12 Mbps auto-detecting\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003ePower Supply:\u003c\/span\u003e 24V DC via backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTemperature:\u003c\/span\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eHumidity:\u003c\/span\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMounting:\u003c\/span\u003e Plugs directly into Honeywell I\/O rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eLEDs:\u003c\/span\u003e Power, communication, fault status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCommunication Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupports up to 125 Profibus DP slaves\u003c\/li\u003e\n\u003cli\u003eAuto baud rate detection simplifies setup\u003c\/li\u003e\n\u003cli\u003eCyclic and acyclic data exchange\u003c\/li\u003e\n\u003cli\u003eDiagnostic functions for network troubleshooting\u003c\/li\u003e\n\u003cli\u003eSeamless integration with Experion PKS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What Profibus devices work with the CC-IP0101?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003eCC-IP0101\u003c\/strong\u003e connects to any standard Profibus DP slave. This includes drives, remote I\/O, valves, and third-party sensors from Siemens, ABB, and others.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many devices can I connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: You can connect up to 125 Profibus DP slaves to one \u003cstrong\u003eCC-IP0101\u003c\/strong\u003e gateway. Network length depends on baud rate and cable type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is order code 51410056-175 used for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 51410056-175 is Honeywell's ordering code for the \u003cstrong\u003eCC-IP0101\u003c\/strong\u003e. Use this number when referencing the module in procurement systems or verifying compatibility.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573161459844,"sku":"CC-IP0101","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-IP0101.jpg?v=1772351124"},{"product_id":"cc-pail51-honeywell-analog-output","title":"CC-PAIL51 | Honeywell Analog Output","description":"\u003ch2\u003eHoneywell CC-PAIL51: Industrial Analog Output\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIL51\u003c\/strong\u003e converts digital commands to precise 4-20mA current signals. This analog output module connects directly to final control elements in process plants. \u003c\/p\u003e\n\u003ch2\u003eOutput Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eBrand:\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eModel:\u003c\/span\u003e CC-PAIL51\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eType:\u003c\/span\u003e Analog Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eSignal:\u003c\/span\u003e 4-20 mA current loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eChannels:\u003c\/span\u003e Multiple independent outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eLoad:\u003c\/span\u003e 0-600Ω per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eAccuracy:\u003c\/span\u003e ±0.15% of span\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eResolution:\u003c\/span\u003e 14-bit conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eUpdate:\u003c\/span\u003e 100ms typical scan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Tolerance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003ePower:\u003c\/span\u003e 24V DC backplane supplied\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTemperature:\u003c\/span\u003e -40°C to +70°C operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eStorage:\u003c\/span\u003e -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eHumidity:\u003c\/span\u003e 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIsolation:\u003c\/span\u003e 1000V field to logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eVibration:\u003c\/span\u003e IEC 60068-2-6 rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWeight:\u003c\/span\u003e 0.8kg (1.76 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eDimensions:\u003c\/span\u003e 130mm x 90mm x 40mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTerminals:\u003c\/span\u003e Pluggable euro-style connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIndicators:\u003c\/span\u003e Channel active LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMounting:\u003c\/span\u003e Honeywell series I\/O rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMaterial:\u003c\/span\u003e High-impact thermoplastic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What typical devices connect to the CC-PAIL51?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Most users connect current-to-pressure transducers and control valves. The \u003cstrong\u003eCC-PAIL51\u003c\/strong\u003e also drives analog speed references for pumps and fans.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module survive a field wiring short?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Each output tolerates momentary shorts. The \u003cstrong\u003eCC-PAIL51\u003c\/strong\u003e recovers automatically when the short clears without damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify channel operation without a meter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Watch the channel LED. It glows steadily when the output drives current. A flashing pattern indicates fault conditions like open loop.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573164507268,"sku":"CC-PAIL51","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIL51.jpg?v=1772351528"},{"product_id":"honeywell-cc-pdod51-32-channel-digital-output","title":"Honeywell CC-PDOD51 32-Channel Digital Output","description":"\u003ch2\u003eHoneywell CC-PDOD51: 32-Channel Sink Digital Output\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PDOD51\u003c\/strong\u003e delivers high-density digital switching for industrial applications. \u003c\/p\u003e\n\u003ch2\u003eOutput Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eBrand:\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eModel:\u003c\/span\u003e CC-PDOD51\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eType:\u003c\/span\u003e Series C Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eChannels:\u003c\/span\u003e 32 digital outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOutput Type:\u003c\/span\u003e SINK (Open Drain)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eLoad Voltage:\u003c\/span\u003e 30 VDC maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eLoad Current:\u003c\/span\u003e 0.1 A per channel max\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOn-State Voltage:\u003c\/span\u003e 0 VDC at 0.1A load\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOff-State Voltage:\u003c\/span\u003e 24 VDC typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOff-State Leakage:\u003c\/span\u003e 100 µA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTurn-On\/Off Time:\u003c\/span\u003e 10 ms maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIsolation \u0026amp; Protection\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eGalvanic Isolation:\u003c\/span\u003e 1000 VAC RMS system-to-field\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eField Power:\u003c\/span\u003e User supplied external 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eBussed Output:\u003c\/span\u003e Common return for group wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCoating:\u003c\/span\u003e Conformal coated for harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eRedundancy Gap:\u003c\/span\u003e 0ms switchover (redundant systems)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible IOTA\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIOTA Model:\u003c\/span\u003e CC-TDOD51\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eConfiguration:\u003c\/span\u003e Non Redundant\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIOTA Position:\u003c\/span\u003e 9 (standard mounting)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTemperature:\u003c\/span\u003e -40°C to +70°C operating\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eStorage:\u003c\/span\u003e -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eHumidity:\u003c\/span\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eVibration:\u003c\/span\u003e IEC 60068-2-6 compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eEMC:\u003c\/span\u003e IEC 61000-6-2, IEC 61000-6-4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWeight:\u003c\/span\u003e 0.9kg (1.98 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTerminals:\u003c\/span\u003e Via CC-TDOD51 IOTA\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eLED Indicators:\u003c\/span\u003e Per channel status on IOTA\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMounting:\u003c\/span\u003e Series C I\/O rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCoating:\u003c\/span\u003e Conformal coated circuit boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What external power supply do I need for the CC-PDOD51?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e requires a user-supplied 24V DC field power source. Connect this to the CC-TDOD51 IOTA terminals. The module isolates this field power from the system backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I drive 24V DC relays with the 0.1A output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Most industrial relays draw 20-50mA at 24V. The \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e easily drives them. Check your specific relay coil current stays under 100mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does 0ms gap mean for redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: In redundant configurations, the \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e switches outputs with zero interruption. The backup takes over immediately with no current gap to field devices.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573166211204,"sku":"CC-PDOD51","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PDOD51.jpg?v=1772351841"},{"product_id":"cc-tail51-honeywell-analog-input-4-20ma","title":"CC-TAIL51 | Honeywell Analog Input 4-20mA","description":"\u003ch2\u003eHoneywell CC-TAIL51: Field Transmitter Interface\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAIL51\u003c\/strong\u003e captures analog signals from field sensors and transmitters. This input module converts 4-20mA currents into digital values for control system use. \u003c\/p\u003e\n\u003ch2\u003eInput Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eBrand:\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eModel:\u003c\/span\u003e CC-TAIL51\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eType:\u003c\/span\u003e Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eSignal:\u003c\/span\u003e 4-20 mA current loops\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eChannels:\u003c\/span\u003e 16 single-ended inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eInput Resistance:\u003c\/span\u003e 250Ω internal\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eConversion:\u003c\/span\u003e 15-bit plus sign\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eAccuracy:\u003c\/span\u003e ±0.1% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eScan Rate:\u003c\/span\u003e 50ms all channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eField Connection\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eLoop Power:\u003c\/span\u003e User supplied 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIsolation:\u003c\/span\u003e 1000V channel-to-ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTerminals:\u003c\/span\u003e Removable Euro-style plugs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWiring:\u003c\/span\u003e Accepts 14-22 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIndicators:\u003c\/span\u003e Channel active LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eFusing:\u003c\/span\u003e Individual channel protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Limits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOperating Temp:\u003c\/span\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eStorage Temp:\u003c\/span\u003e -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eHumidity:\u003c\/span\u003e 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eVibration:\u003c\/span\u003e 2g at 10-150Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eShock:\u003c\/span\u003e 15g half-sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eEMC:\u003c\/span\u003e Industrial heavy industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWeight:\u003c\/span\u003e 0.85kg (1.87 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eDimensions:\u003c\/span\u003e 125mm x 85mm x 45mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMaterial:\u003c\/span\u003e UL94V-0 rated plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMounting:\u003c\/span\u003e Honeywell Series C rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCooling:\u003c\/span\u003e Convection, no fan needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCoating:\u003c\/span\u003e Standard industrial grade\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCommon Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Do I need external loop power for each transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The \u003cstrong\u003eCC-TAIL51\u003c\/strong\u003e does not supply loop power. Connect each 4-20mA transmitter to a 24V supply and wire the return to the module input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if a field wire shorts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Individual channel fuses protect the \u003cstrong\u003eCC-TAIL51\u003c\/strong\u003e. A shorted input affects only that channel. Replace the fuse and correct the wiring fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I read 0-20mA signals instead of 4-20mA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The \u003cstrong\u003eCC-TAIL51\u003c\/strong\u003e accepts the full 0-20mA range. Configure the input scaling in your control software to match your transmitter output.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573166342276,"sku":"CC-TAIL51","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TAIL51.jpg?v=1772352373"},{"product_id":"honeywell-cc-taix01-51308363-175-analog-input-module","title":"Honeywell CC-TAIX01 51308363-175 Analog Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eHoneywell CC-TAIX01 51308363-175\u003c\/strong\u003e operates as a high-density Analog Input Field Termination Assembly (IOTA) designed for the Experion Process Knowledge System (PKS) C300 controller. This premium module bridges field transmitters and your control system, delivering accurate signal conditioning and superior transient protection for critical industrial process loops.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technological Advantages\u003c\/h2\u003e\n\u003ch3\u003eRobust Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eThe hardware features 1500 VAC continuous galvanic isolation between field circuitry and internal logic, blocking voltage surges and eliminating ground-loop interference.\u003c\/p\u003e\n\n\u003ch3\u003eAdvanced Thermal Efficiency\u003c\/h3\u003e\n\u003cp\u003eLow power engineering minimizes thermal buildup. The unit draws only 0.320 Amps at 24 VDC, limiting total heat dissipation to 2.464 Watts.\u003c\/p\u003e\n\n\u003ch3\u003eActive Signal Protection\u003c\/h3\u003e\n\u003cp\u003eOnboard surge suppression and integrated low-pass filtering clean data streams by attenuating high-frequency electrical noise and EMI above 50 Hz.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #1a365d; color: #ffffff;\"\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eValue \/ Operational Limit\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCC-TAIX01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e51308363-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eInput Channels\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e16 High-Level Analog Inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSignal Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e4 to 20 mA \/ 1 to 5 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCurrent Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.320 Amps @ 24 VDC maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHeat Dissipation\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2.464 Watts maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eResolution \u0026amp; Accuracy\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e16-Bit Sigma-Delta \/ ±0.075% FS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0°C to +60°C (+32°F to +140°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHarsh Environment Protection\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eISA-S71.04 Class G3 Conformal Coating\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eCabinet Placement\u003c\/h3\u003e\n\u003cp\u003eMount the unit vertically or horizontally on standard Experion C300 rows. Maintain 50mm clearance above and below the assembly for natural convective airflow.\u003c\/p\u003e\n\n\u003ch3\u003eField Wiring Rules\n\u003c\/h3\u003e\u003cp\u003eUse 18 AWG (0.8 mm²) twisted, shielded pair cables. Ground the shield at a single point on the board bars. Keep low-voltage lines 300mm away from high-voltage AC cables.\u003c\/p\u003e\n\n\u003ch3\u003eHazardous Locations\u003c\/h3\u003e\n\u003cp\u003eIn Class I, Division 2 \/ Zone 2 setups, torque screw clamps to 0.5 Nm. Never swap or disconnect wiring while the 24 VDC power is active unless the area is verified safe.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eNative DCS Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module provides plug-and-play auto-discovery within Experion PKS, eliminating manual driver configuration or firmware re-flashing.\u003c\/p\u003e\n\n\u003ch3\u003eEnvironmental Durability\u003c\/h3\u003e\n\u003cp\u003eStandard G3 conformal coating guards circuits against H2S, Cl2, and NH3 gases, preventing corrosive oxidation and failure.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Fault Redundancy\u003c\/h3\u003e\n\u003cp\u003eDual-cable routing supports sub-millisecond line switching, preventing unplanned process shutdowns if a main signal line breaks.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does the module handle a broken field transmitter wire?\u003c\/strong\u003e\u003cbr\u003e\nA1: Integrated NAMUR NE43 burnout detection flags faults when current drops below 3.6 mA, triggering an immediate HMI alarm and moving the loop to a safe state.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can this assembly supply loop power to field transmitters?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes. The board routes 24 VDC power directly to field terminals, delivering up to 25 mA per channel to run 2-wire transmitters without external power blocks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What specific hardware metrics can be monitored online?\u003c\/strong\u003e\u003cbr\u003e\nA3: The DCS displays internal hardware temperature, supply rail limits (faulting below 21.6 VDC or above 28.8 VDC), and ADC converter health.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51884955926660,"sku":"51308363-175","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TAIX01_51308363-175.jpg?v=1779545905"},{"product_id":"51308353-175-honeywell-16-ch-analog-output","title":"51308353-175 Honeywell | 16-kanałowe wyjście analogowe","description":"\u003ch2 style=\"color:#0055A4;\"\u003ePrzegląd produktu\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0055A4;\"\u003eCC-TAOX11 (51308353-175)\u003c\/strong\u003e to 16-kanałowy moduł wyjścia analogowego Honeywell. Dostarcza sygnały 4-20 mA do siłowników, zaworów i pozycjonerów. Ten moduł zapewnia precyzyjną kontrolę dla systemu Experion PKS.\u003c\/p\u003e\n\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003eHoneywell\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eNumer produktu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eCC-TAOX11 \/ 51308353-175\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eModuł wyjścia analogowego\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTyp wyjścia\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e4-20 mA (źródłowe)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eKanały wyjściowe\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e16 kanałów (izolowanych)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eRozdzielczość\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e15 bitów plus znak\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eDokładność\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e±0,1% zakresu (25°C)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eObciążenie rezystancyjne\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0 do 750 Ω\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eCzęstotliwość aktualizacji\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e10 ms na kanał\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°F do 185°F (-40°C do +85°C)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eZasilanie\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 VDC ±10%\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003ePobór prądu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e250 mA (typowo)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eDiagnostyka\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eWykrywanie przerwy i zwarcia obwodu\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstrukcja montażu\u003c\/h3\u003e\n\u003cp\u003ePodłącz każdy kanał za pomocą ekranowanego kabla skrętkowego. Ekran podłącz tylko do uziemienia przy module. Nie przekraczaj obciążenia 750 Ω na kanał. Przed zasileniem modułu sprawdź polaryzację zasilania 24 VDC.\u003c\/p\u003e\n\n\u003ch3\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003eTen moduł steruje 16 niezależnymi pętlami 4-20 mA. Diagnostyka na pokładzie zgłasza przerwy i zwarcia do systemu Experion PKS. CC-TAOX11 działa niezawodnie w temperaturach od -40°F do 185°F, odpowiedni do hal turbin i stacji sprężarek.\u003c\/p\u003e\n\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Czy ten moduł może generować sygnał 0-20 mA?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Nie. CC-TAOX11 obsługuje tylko 4-20 mA. 0 mA oznacza błąd pętli.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Co się stanie, jeśli kanał zostanie przeciążony?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Moduł zgłasza diagnostykę zwarcia. Każdy kanał resetuje się automatycznie po usunięciu usterki.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Czy protokół HART jest obsługiwany?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Nie. Ten moduł przesyła tylko analogowe sygnały 4-20 mA. Do komunikacji cyfrowej użyj multipleksera HART.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51886704033924,"sku":"51308353-175","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/51308353-175.jpg?v=1779627530"},{"product_id":"honeywell-cc-tdil01-24v-digital-input-module-0-19a","title":"Moduł wejścia cyfrowego Honeywell CC-TDIL01 24V | 0,19A","description":"\u003ch2 style=\"color:#0055A4;\"\u003ePrzegląd produktu\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0055A4;\"\u003eCC-TDIL01\u003c\/strong\u003e to cyfrowy moduł wejściowy IOTA firmy Honeywell (Input Output Terminal Assembly). Ten moduł 24V DC rejestruje dyskretne sygnały polowe dla Experion PKS. Obsługuje wyłączniki krańcowe, przyciski i czujniki zbliżeniowe.\u003c\/p\u003e\n\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003eHoneywell\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eNumer produktu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eCC-TDIL01\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eModuł cyfrowych wejść IOTA\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eNapięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 VDC (20,4 do 28,8 VDC)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eKanały wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e16 kanałów (konfigurowalne jako sink\/source)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003ePobór prądu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0,190 A (190 mA przy 24 VDC)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eRozpraszanie ciepła\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e4,220 Watów\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTyp wejścia\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 VDC styk beznapięciowy lub czujnik zbliżeniowy 3-przewodowy\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eNapięcie stanu WŁĄCZONEGO\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e≥15 VDC\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eNapięcie stanu WYŁĄCZONEGO\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e≤5 VDC\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e4,7 kΩ\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eCzas reakcji\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e2 ms (WŁĄCZ do WYŁĄCZ) \/ 1 ms (WYŁĄCZ do WŁĄCZ)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eNapięcie izolacji\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1500 Vrms (kanał do szyny tylnej)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°F do 185°F (-40°C do +85°C)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eMontaż\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eMontaż na szynie DIN lub panelu\u003c\/td\u003e\n   \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstrukcja montażu\u003c\/h3\u003e\n\u003cp\u003ePodłącz styki beznapięciowe między zaciskiem wejściowym a wspólnym. Dla czujników zbliżeniowych 3-przewodowych podłącz +24V, wspólny i sygnał. Nie przekraczaj 28,8 VDC na żadnym kanale wejściowym. Przed okablowaniem sprawdź konfigurację sinking lub sourcing urządzenia polowego.\u003c\/p\u003e\n\n\u003ch3\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003eTen moduł IOTA rozprasza tylko 4,22 wata, minimalizując obciążenie cieplne szafy. Impedancja wejściowa 4,7 kΩ zapobiega fałszywym wyzwoleniom spowodowanym prądem upływu. Izolacja kanału od szyny tylnej na poziomie 1500 Vrms chroni sterownik przed przepięciami z pola.\u003c\/p\u003e\n\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Czy mogę mieszać wejścia typu sinking i sourcing?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Tak. Każdy kanał konfiguruje się niezależnie jako sink lub source przez okablowanie zacisków.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Jaka jest minimalna napięcie stanu WŁĄCZONEGO?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Moduł gwarantuje stan WŁĄCZONY przy ≥15 VDC. Pomiędzy 5V a 15V odczyt jest nieokreślony.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Czy obsługuje sygnały wejściowe 12 VDC?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Nie. CC-TDIL01 wymaga nominalnie 24 VDC. Użyj przekaźnika pośredniczącego dla urządzeń polowych 12 VDC.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51886706360452,"sku":"CC-TDIL01","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TDIL01.jpg?v=1779628692"},{"product_id":"honeywell-dc-taox11-system-module-24v-output","title":"Moduł systemowy Honeywell DC-TAOX11 | Wyjście 24V","description":"\u003ch2 style=\"color:#0055A4;\"\u003ePrzegląd produktu\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0055A4;\"\u003eDC-TAOX11\u003c\/strong\u003e to moduł systemowy Honeywell pełniący funkcję modułu wejściowego systemu. Zapewnia maksymalne napięcie wyjściowe do 24 V. Moduł obsługuje akwizycję sygnałów analogowych dla Experion PKS.\u003c\/p\u003e\n\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003eHoneywell\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eNumer produktu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eDC-TAOX11\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eModuł systemowy \/ Moduł wejściowy systemu\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eMaksymalne napięcie wyjściowe zgodne ze specyfikacją\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 V DC\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eKanały wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e8 wejść analogowych\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eZakres sygnału wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0 do 20 mA \/ 4 do 20 mA \/ ±10 VDC\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eRozdzielczość\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e16 bitów\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eDokładność\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e±0,05% zakresu (25°C)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eCzęstotliwość próbkowania\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e20 ms na kanał\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eZasilanie\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 VDC ±10%\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003ePobór prądu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e150 mA\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eRozpraszanie ciepła\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e3,6 Wata\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eIzolacja\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1500 Vrms (kanał do szyny tylnej)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°F do 185°F (-40°C do +85°C)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°F do 185°F (-40°C do +85°C)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eMontaż\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eSzyna DIN\u003c\/td\u003e\n   \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstrukcja montażu\u003c\/h3\u003e\n\u003cp\u003eZamontuj moduł na szynie DIN z odpowiednim uziemieniem. Podłącz ekranowane skrętkowe kable do wejść analogowych. Ekran zakończ tylko na końcu modułu. Sprawdź polaryzację zasilania 24 VDC przed włączeniem systemu.\u003c\/p\u003e\n\n\u003ch3\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003eDC-TAOX11 zapewnia rozdzielczość 16-bitową dla precyzyjnych pomiarów analogowych. Izolacja 1500 Vrms chroni szynę tylną przed przepięciami z pola. Moduł działa niezawodnie w temperaturach od -40°F do 185°F, odpowiedni do ekstremalnych warunków.\u003c\/p\u003e\n\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Czy ten moduł może przyjmować zarówno sygnały prądowe, jak i napięciowe?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Tak. Każdy kanał konfiguruje się niezależnie dla 0-20 mA, 4-20 mA lub ±10 VDC.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Jaka jest maksymalna napięcie wejściowe bez uszkodzenia?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Moduł wytrzymuje ±30 VDC na dowolnym kanale wejścia analogowego.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Czy DC-TAOX11 obsługuje komunikację HART?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Nie. To jest tylko moduł wejścia analogowego. Użyj osobnego multipleksera HART do nakładki cyfrowej.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51886720123012,"sku":"DC-TAOX11","price":266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DC-TAOX11-2.jpg?v=1779630211"},{"product_id":"dc-tfb412-51307618-176-honeywell-16-i-o-module","title":"DC-TFB412 51307618-176 Moduł 16 I\/O Honeywell","description":"\u003ch2 style=\"color:#2c3e50; font-size:1.4rem; margin:0 0 10px 0;\"\u003e\n\u003cstrong style=\"color:#0066cc;\"\u003eDC-TFB412\u003c\/strong\u003e 51307618-176 – moduł I\/O Honeywell\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color:#0066cc;\"\u003eDC-TFB412\u003c\/strong\u003e od Honeywell oferuje 16 wejść cyfrowych i 16 wyjść cyfrowych. Maksymalna moc 10W. Praca w zakresie 0-60°C.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:1.2rem; margin:20px 0 10px 0;\"\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; background:#f9f9f9; font-size:14px;\"\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth style=\"text-align:left; padding:8px;\"\u003eParametr\u003c\/th\u003e\n\u003cth style=\"text-align:left; padding:8px;\"\u003eWartość\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eNadaje się do \u003cstrong\u003eprogramowania w fazie rozwoju, debugowania i produkcji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e\n\u003cstrong style=\"color:#0066cc;\"\u003eDC-TFB412\u003c\/strong\u003e \/ 51307618-176\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eMarka\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eWymiary (WxSxG)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e10 cm x 18 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eWaga\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e0,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eWejścia cyfrowe\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e16 kanałów\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eWyjścia cyfrowe\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e16 kanałów\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eNapięcie zasilania\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eNominalne 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eMaks. moc\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e10 watów\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e0°C do 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e-40°C do 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eWilgotność\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e5% do 95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size:1.2rem; margin:20px 0 10px 0;\"\u003eInstrukcja montażu\u003c\/h3\u003e\n\u003cp\u003eUziem zwrot 24V. Używaj tulejek na przewodach wielożyłowych. Dodaj diodę wolnobieżną (1N4007) dla obciążeń indukcyjnych.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:1.2rem; margin:20px 0 10px 0;\"\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003ePraca w zakresie 0°C do 60°C. Wyjścia zabezpieczone przed zwarciem. Bezpośrednia integracja TSI.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:1.2rem; margin:20px 0 10px 0;\"\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1\u003c\/strong\u003e Sprawdzić wejście bez napięcia z pola?\u003cbr\u003e\u003cstrong\u003eA1\u003c\/strong\u003e Wymuś logikę 1 przez oprogramowanie. Diody LED potwierdzają status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2\u003c\/strong\u003e Używać dwóch oddzielnych zasilaczy 24V?\u003cbr\u003e\u003cstrong\u003eA2\u003c\/strong\u003e Tak. Wspólna masa obu zacisków V-.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3\u003c\/strong\u003e Czy rewizja -176 jest wstecznie kompatybilna?\u003cbr\u003e\u003cstrong\u003eA3\u003c\/strong\u003e Tak. Zastępuje -153 i -162.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51886765342852,"sku":"51307618-176","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/51307618-176.jpg?v=1779630761"},{"product_id":"51199942-300-cc-scmb02-honeywell-control-module","title":"51199942-300 CC-SCMB02 Moduł sterujący Honeywell","description":"\u003ch2 style=\"color:#2c3e50; font-size:1.4rem; margin:0 0 10px 0;\"\u003e\n\u003cstrong style=\"color:#0066cc;\"\u003eCC-SCMB02\u003c\/strong\u003e 51199942-300 – moduł I\/O Honeywell\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color:#0066cc;\"\u003eCC-SCMB02\u003c\/strong\u003e od Honeywell posiada pamięć nieulotną z 72-godzinnym zasilaniem awaryjnym. Działa w zakresie od -40°C do 70°C. Przechowuje dane przez 10 lat bez zasilania.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:1.2rem; margin:20px 0 10px 0;\"\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; background:#f9f9f9; font-size:14px;\"\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth style=\"text-align:left; padding:8px;\"\u003eParametr\u003c\/th\u003e\n\u003cth style=\"text-align:left; padding:8px;\"\u003eWartość\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eNadaje się do \u003cstrong\u003eprogramowania w fazie rozwoju, debugowania i produkcji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e\n\u003cstrong style=\"color:#0066cc;\"\u003eCC-SCMB02\u003c\/strong\u003e \/ 51199942-300\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eMarka\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eWymiary (WxSxG)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e12 cm x 7 cm x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eWaga\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e0,8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eTyp połączenia\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003ePołączenie kablowe\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eNapięcie znamionowe\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eNapięcie nominalne 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eCzas pracy awaryjnej\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eDo 72 godzin\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eTyp pamięci\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003ePamięć nieulotna\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003ePrzechowywanie danych\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e10 lat bez zasilania\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e-40°C do +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eWilgotność\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e5% do 95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOdporność na wstrząsy\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e30 G, półokres sinusoidy 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOdporność na wibracje\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e2 G szczyt, 10-500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size:1.2rem; margin:20px 0 10px 0;\"\u003eInstrukcja montażu\u003c\/h3\u003e\n\u003cp\u003eZabezpiecz połączenie kablowe przed naprężeniami. Montuj w suchej szafie w temperaturze od -40°C do 70°C. Zachowaj 5 cm odstępu dla przepływu powietrza.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:1.2rem; margin:20px 0 10px 0;\"\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003eOdporność na wstrząsy 30G i drgania 2G. Pamięć nieulotna przechowuje dane przez 10 lat. 72 godziny pracy awaryjnej bez zewnętrznego zasilania.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:1.2rem; margin:20px 0 10px 0;\"\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1\u003c\/strong\u003e Co się dzieje po 72 godzinach pracy na zasilaniu awaryjnym?\u003cbr\u003e\u003cstrong\u003eA1\u003c\/strong\u003e Pamięć nieulotna przechowuje wszystkie dane przez 10 lat. Po przywróceniu zasilania urządzenie działa normalnie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2\u003c\/strong\u003e Czy ten moduł może działać w temperaturach poniżej zera?\u003cbr\u003e\u003cstrong\u003eA2\u003c\/strong\u003e Tak. Przeznaczony do pracy w temperaturach od -40°C do +70°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3\u003c\/strong\u003e Czy pole połączenia kablowego jest wymienne?\u003cbr\u003e\u003cstrong\u003eA3\u003c\/strong\u003e Nie. Kabel jest przymocowany fabrycznie. Nie należy go ciąć ani przedłużać.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51886770847876,"sku":"CC-SCMB02","price":221.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-SCMB02-2.jpg?v=1779631192"}],"url":"https:\/\/www.etowonauto.com\/pl\/collections\/honeywell-c300.oembed?page=2","provider":"Etowon Auto","version":"1.0","type":"link"}