{"product_id":"schneider-tsxcty2c-modicon-counter-module-2-channel","title":"Schneider TSXCTY2C Modicon Counter Module 2 Channel","description":"\u003ch2\u003eSchneider Electric TSXCTY2C Modicon Counter Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eSchneider Electric TSXCTY2C\u003c\/strong\u003e | Measurement and counter module for the Modicon Premium and TSX Micro automation platforms. Provides 2 counter channels supporting incremental encoders, absolute encoders, and 2\/3-wire proximity sensors. Counting frequency up to 1 MHz. Current sink auxiliary inputs for preset, enable, and read functions. Weight: 0.34 kg (0.75 lb).\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e2 counter channels. Counting frequency up to 1 MHz. Incremental encoder frequency 500 kHz (x1) and 250 kHz (x4). 1 ms cycle time. Current sink auxiliary inputs (preset, enable, read). Compatible with 2\/3-wire PNP\/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders. 24V DC output with 0.5 A nominal current. Thermal overload and short-circuit protection. Zener diode overvoltage protection. Reverse polarity protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTSXCTY2C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eTSX Micro PLCs \/ Modicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMeasurement and Counter Module\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCounting Frequency\u003c\/td\u003e\n\u003ctd\u003e1,000,000 Hz (1 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIncremental Encoder Frequency (x1)\u003c\/td\u003e\n\u003ctd\u003e500 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIncremental Encoder Frequency (x4)\u003c\/td\u003e\n\u003ctd\u003e250 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCycle Time\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Logic\u003c\/td\u003e\n\u003ctd\u003eCurrent sink auxiliary input (preset, enable, read)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003e2\/3-wire PNP\/NPN proximity sensors, incremental encoder (10-30V totem pole, 5V DC RS422), SSI absolute encoder, ABE7CPA11\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage (Sensors)\u003c\/td\u003e\n\u003ctd\u003e24V, 16 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage (Auxiliary)\u003c\/td\u003e\n\u003ctd\u003e24V, 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage (Encoder)\u003c\/td\u003e\n\u003ctd\u003e5V, 18 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage State 1 (Sensors\/Aux)\u003c\/td\u003e\n\u003ctd\u003e≥ 11V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage State 1 (Encoder)\u003c\/td\u003e\n\u003ctd\u003e≥ 2.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage State 0 (Encoder)\u003c\/td\u003e\n\u003ctd\u003e≤ 1.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage State 0 (Sensors\/Aux)\u003c\/td\u003e\n\u003ctd\u003e≤ 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Impedance (Encoder)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 270 Ω at 2.4V; 400 Ω at Un\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Impedance (Sensors)\u003c\/td\u003e\n\u003ctd\u003e1500 Ω at Un\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Impedance (Auxiliary)\u003c\/td\u003e\n\u003ctd\u003e3400 Ω at Un\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResponse Time (Loss of 24V)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResponse Time (Return of 24V)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24V DC (19-30V limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5V at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSwitching Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eThermal overload, short-circuit, Zener overvoltage, reverse polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e7-10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e15 mA @ 24V DC; 850 mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eLocal Signaling\u003c\/td\u003e\n\u003ctd\u003eRUN (green), I\/O fault (red), ERR (red), 2x CH diagnostics (green)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e1 HE-10 20-pin connector; 2 SUB-D 15 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMount in Modicon Premium or TSX Micro PLC rack. Connect sensors and encoders via HE-10 20-pin and SUB-D 15 connectors. Verify input voltage limits for each device type: ≤5.5V for encoder, 19-30V for sensors and auxiliary inputs. Use shielded cable for encoder signals to maintain signal integrity at high counting frequencies. Maintain IP20 enclosure and pollution degree 2 environment. LED indicators aid commissioning and fault diagnosis.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e1 MHz counting frequency supports high-speed position and motion applications. Dual channels enable simultaneous measurement of two axes. Wide input compatibility covers proximity sensors, incremental encoders, and SSI absolute encoders in a single module. Integrated thermal overload, short-circuit, overvoltage, and reverse polarity protection safeguard the module. 1 ms cycle time ensures fast response for time-critical control. LED diagnostics simplify troubleshooting.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the maximum counting frequency?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 1 MHz, with 500 kHz (x1) and 250 kHz (x4) for incremental encoders.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What input types are supported?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 2\/3-wire PNP\/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What output does the module provide?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e 24V DC output with 0.5 A nominal current, supporting positive logic DC inputs up to 15 kΩ.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67650481389700,"sku":"TSXCTY2C","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/TSXCTY2C-2.jpg?v=1792314272","url":"https:\/\/www.etowonauto.com\/nl\/products\/schneider-tsxcty2c-modicon-counter-module-2-channel","provider":"Etowon Auto","version":"1.0","type":"link"}