{"product_id":"schneider-atv71hc25n4-altivar-71-vsd-220kw","title":"Schneider ATV71HC25N4 Altivar 71 VSD 220kW","description":"\u003ch2\u003eSchneider Electric ATV71HC25N4 Altivar 71 Variable Speed Drive\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eSchneider Electric ATV71HC25N4\u003c\/strong\u003e | Altivar 71 variable speed drive for complex, high-power machines. Delivers 220 kW continuous (250 kW maximum) motor power with 481 A nominal output current at 380-480V three-phase supply. Integrated EMC filter and forced-air heat sink for demanding industrial applications. Supports asynchronous and synchronous motors. Weight: 207 kg (456.4 lbs).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eATV71HC25N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eAltivar 71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Speed Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power (Continuous)\u003c\/td\u003e\n\u003ctd\u003e220 kW (350 HP), 3-phase 380-480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power (Maximum)\u003c\/td\u003e\n\u003ctd\u003e250 kW (400 HP), 3-phase 380-480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e380-480V (-15%\/+10%), 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e323-528V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz ±5% (47.5-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Current (480V, 220kW)\u003c\/td\u003e\n\u003ctd\u003e320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Current (480V, 250kW)\u003c\/td\u003e\n\u003ctd\u003e357 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Current (380V, 220kW)\u003c\/td\u003e\n\u003ctd\u003e396 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Current (380V, 250kW)\u003c\/td\u003e\n\u003ctd\u003e444 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent Power (220kW)\u003c\/td\u003e\n\u003ctd\u003e260.6 kVA @ 380V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent Power (250kW)\u003c\/td\u003e\n\u003ctd\u003e292.2 kVA @ 380V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current (220kW)\u003c\/td\u003e\n\u003ctd\u003e427 A @ 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current (250kW)\u003c\/td\u003e\n\u003ctd\u003e481 A @ 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transient Current (220kW)\u003c\/td\u003e\n\u003ctd\u003e640 A for 60 s; 704 A for 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transient Current (250kW)\u003c\/td\u003e\n\u003ctd\u003e721 A for 60 s; 793 A for 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0.1-500 Hz (adjustable to 599 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e2.5 kHz (adjustable 2.5-8 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProspective Line Isc\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Filter\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Sink\u003c\/td\u003e\n\u003ctd\u003eYes (forced air cooling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Interface\u003c\/td\u003e\n\u003ctd\u003eGraphic terminal (HMI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Methods\u003c\/td\u003e\n\u003ctd\u003eSensorless Vector, Vector, V\/f, Synchronous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e2 (AI1 ±10V, AI2 0-20mA\/0-10V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e1 (AO1 0-20mA\/0-10V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e7 (LI1-LI5 programmable 24VDC, LI6 configurable, PWR safety)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e2 relay (R1 NO\/NC, R2 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus (2-wire RS485), CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rates (Modbus)\u003c\/td\u003e\n\u003ctd\u003e4800, 9600, 19200, 38.4 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rates (CANopen)\u003c\/td\u003e\n\u003ctd\u003e20 kbps to 1 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Accuracy (Closed-Loop)\u003c\/td\u003e\n\u003ctd\u003e±0.01% of nominal speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque Accuracy (Closed-Loop)\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Overtorque\u003c\/td\u003e\n\u003ctd\u003e170% for 60 s; 220% for 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Torque (with resistor)\u003c\/td\u003e\n\u003ctd\u003e≤150%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1 MOhm at 500V DC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e3535V DC (earth to power); 5092V DC (control to power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e77 dB (86\/188\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e≤1000 m without derating; 1000-3000 m with 1% derating per 100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e0.6 gn (10-200 Hz); 1.5 mm peak-to-peak (3-10 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e4 gn, 11 ms (EN\/IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1190 x 595 x 377 mm (46.9 x 23.4 x 14.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e207 kg (456.4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e200.49 kg (442.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61800-3, EN\/IEC 61800-5-1, UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GOST, NOM 117, C-tick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Technical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Motor Cable Length (Shielded)\u003c\/td\u003e\n\u003ctd\u003e100 m (328.08 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Motor Cable Length (Unshielded)\u003c\/td\u003e\n\u003ctd\u003e200 m (656.2 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Sampling Time\u003c\/td\u003e\n\u003ctd\u003e2 ms ±0.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Sampling Time\u003c\/td\u003e\n\u003ctd\u003e2 ms ±0.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTO Response Time\u003c\/td\u003e\n\u003ctd\u003e≤100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output Response Time\u003c\/td\u003e\n\u003ctd\u003e7 ms ±0.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Linearity Error\u003c\/td\u003e\n\u003ctd\u003e±0.15% of maximum value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Linearity Error\u003c\/td\u003e\n\u003ctd\u003e±0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Mechanical Life\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Switching Current\u003c\/td\u003e\n\u003ctd\u003e3 mA at 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMount vertically (±10°) in an enclosure with forced air cooling for adequate heat dissipation. Connect 380-480V three-phase supply per local electrical codes. Observe terminal tightening torques: 0.6 N·m for control terminals, 41 N·m for power terminals (L1\/R, L2\/S, L3\/T, U\/T1, V\/T2, W\/T3, PC\/-, PA\/+). Maximum motor cable length is 100 m shielded or 200 m unshielded. Maintain operating temperature within -10°C to +50°C without derating. For altitudes above 1000 m, apply 1% current derating per 100 m. Ensure proper grounding and use the integrated EMC filter for electromagnetic compliance.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the motor power rating of this drive?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 220 kW continuous (350 HP) and 250 kW maximum (400 HP) at 380-480V three-phase supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What communication protocols are built in?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e Modbus (2-wire RS485) and CANopen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Does this drive include an EMC filter?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Yes, the EMC filter is integrated.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68011896930436,"sku":"ATV71HC25N4","price":143.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/ATV71HC25N4.jpg?v=1794919530","url":"https:\/\/www.etowonauto.com\/nl\/products\/schneider-atv71hc25n4-altivar-71-vsd-220kw","provider":"Etowon Auto","version":"1.0","type":"link"}