{"product_id":"positioner-original-stock-abb-v18345-1017121001-tzidc","title":"Positioner | Original Stock ABB V18345-1017121001 TZIDC","description":"\u003ch2\u003eABB V18345-1017121001 TZIDC Electro-Pneumatic Positioner\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color:#1a5fb4;\"\u003eV18345-1017121001\u003c\/strong\u003e (also cataloged as the \u003cstrong\u003eV18345\u003c\/strong\u003e Electro-Pneumatic Positioner) is a TZIDC intelligent positioner in a varnished aluminium case rated IP 65 (NEMA 4X). It accepts a 4-20 mA two-wire input and provides single-acting fail-safe, fail-freeze output, with ATEX Ex II 2 G EEx ia II C T6 explosion protection. Unit weight is 1.7 kg.\u003c\/p\u003e\n\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:40%;text-align:left;padding:10px;border:1px solid #ccc;background:#f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width:60%;text-align:left;padding:10px;border:1px solid #ccc;background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eV18345-1017121001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eTZIDC Electro-Pneumatic Positioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eAluminium, IP 65 \/ NEMA 4X, RAL 9005 matte black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eInput Signal\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e4 to 20 mA, two-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eATEX Ex II 2 G EEx ia II C T6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eOutput Function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eSingle acting, fail safe, fail freeze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eSupply Pressure\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1.4 to 6 bar (20 to 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eAir Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e\u0026lt; 0.03 kg\/h \/ 0.015 scfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003ePneumatic Connections\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eThreads G 1\/4 or 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eCable: Thread 1\/2-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eDigital Input\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e0-5 V DC logical 0; 11-30 V DC logical 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eDigital Output\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e5 to 11 V DC, DIN 19234\/NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003ePosition Feedback\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eMechanical kit with proximity switches SJ2-SN (NC or logical 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eElectropneumatic Control and Explosion Protection\u003c\/h3\u003e\n\n\u003cp\u003eThe V18345-1017121001 uses two-wire technology with a nominal 4-20 mA output signal. The digital input switches at 0-5 V DC for logical 0 and 11-30 V DC for logical 1. The digital output follows the DIN 19234\/NAMUR control circuit at 5-11 V DC supply. Supply pressure spans 1.4 to 6 bar (20 to 90 psi), with air consumption below 0.03 kg\/h (0.015 scfm) independent of supply pressure. The ATEX Ex II 2 G EEx ia II C T6 certification permits installation in Zone 1 hazardous gas atmospheres with intrinsically safe input circuits. The case is electrostatically dipped and stove-hardened with epoxy resin; the case is varnished RAL 9005 matte black and the housing cover is Pantone 420. The optional mechanical feedback kit uses SJ2-SN proximity switches configured as NC or logical 1.\u003c\/p\u003e\n\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\n\u003cp\u003eMount the positioner to a linear actuator per DIN\/IEC 534 \/ NAMUR or to a rotary actuator per VDI\/VDE 3845. Verify the hazardous area classification matches ATEX Ex II 2 G EEx ia II C T6 and confirm the input loop is intrinsically safe before wiring. Confirm the 1.7 kg unit is supported by the actuator mounting bracket. Connect the 4-20 mA input through the 1\/2-14 NPT cable entry and the air supply through the G 1\/4 or 1\/4-18 NPT port. Verify supply air is dry and oil-free within 1.4 to 6 bar. Route signal wiring separately from AC power conductors and maintain the varnished case seal for IP 65 \/ NEMA 4X integrity. Set the fail-safe, fail-freeze action and proximity switch logic before placing the loop in service.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003eQ: What is the explosion protection rating of the V18345-1017121001?\u003cbr\u003e\nA: ATEX Ex II 2 G EEx ia II C T6.\u003c\/p\u003e\n\n\u003cp\u003eQ: What is the supply pressure range and air consumption?\u003cbr\u003e\nA: 1.4 to 6 bar (20 to 90 psi); air consumption below 0.03 kg\/h (0.015 scfm).\u003c\/p\u003e\n\n\u003cp\u003eQ: What is the unit weight?\u003cbr\u003e\nA: 1.7 kg.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68128816562308,"sku":"V18345-1017121001","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18345-1017121001.jpg?v=1795097535","url":"https:\/\/www.etowonauto.com\/nl\/products\/positioner-original-stock-abb-v18345-1017121001-tzidc","provider":"Etowon Auto","version":"1.0","type":"link"}