{"product_id":"hima-f3348-safety-module-8-channel-48v-dc-output","title":"HIMA F3348 Safety Module 8-Channel 48V DC Output","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eHIMA F3348\u003c\/strong\u003e is a high-reliability, 8-fold safety-related output module designed for demanding emergency shutdown (ESD) and safety instrumented systems (SIS). Engineered for critical industrial automation applications, this safety-grade module delivers eight individual 48 V DC output channels capable of driving resistive or inductive loads up to 500 mA with integrated safe isolation.\u003c\/p\u003e\n\n\u003cp\u003eCertified for safety requirement classes AK 1 through AK 6, the \u003cstrong style=\"color: #0056b3;\"\u003eF3348\u003c\/strong\u003e features automated internal testing with short test signal durations (maximum 200 µs) to verify output integrity without interrupting connected process devices. Occupying a compact 4 TE rack slot width, the module has a net weight of approximately \u003cstrong\u003e0.40 kg (0.88 lbs)\u003c\/strong\u003e with a standard packed shipping weight of \u003cstrong\u003e2.00 kg (4.41 lbs)\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety-Related Architecture:\u003c\/strong\u003e Complies with requirement classes AK 1 to AK 6, ensuring reliable safety shutdown functionality in critical process control loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Circuit Proof Outputs:\u003c\/strong\u003e Eight independent 48 V DC \/ 500 mA channels equipped with short-circuit protection and safe galvanic isolation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Test Execution:\u003c\/strong\u003e Supports online self-test diagnostics with maximum test signal duration of 200 µs to prevent accidental actuator tripping.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Load Compatibility:\u003c\/strong\u003e Drives resistive loads, inductive loads (up to 500 mA), and signal lamps (up to 4 W) with built-in safety shutdown protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eHIMA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eF3348\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8-Fold Safety-Related Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8 Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eNominal Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e48 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eOutput Load Capacity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e500 mA per channel (Resistive \/ Inductive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eLamp Load Connection\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eUp to 4 W with safety shutdown\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eOutput Protection Features\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eShort-circuit proof, safe galvanic isolation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eTest Signal Pulse Width\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMax. 200 µs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eSafety Class Requirement\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eRequirement Class AK 1 ... AK 6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eRack Space Requirement\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4 TE slot width\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eEstimated Net \/ Gross Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eNet Unit: 0.40 kg (0.88 lbs) | Gross Shipping: 2.00 kg (4.41 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack Insertion:\u003c\/strong\u003e Insert the 4 TE module firmly into the designated safety rack slot and engage locking screws to maintain proper backplane connection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Load Cabling:\u003c\/strong\u003e Ensure load wiring matches 48 V DC ratings and does not exceed the maximum per-channel current limit of 500 mA.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation Integrity:\u003c\/strong\u003e Maintain separation between safety-critical field lines and standard non-safety signal wiring to preserve safe isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What safety requirement classes does the HIMA F3348 module support?\u003c\/strong\u003e\u003cbr\u003e\nA1: The F3348 module is certified for safety requirement classes AK 1 through AK 6.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum test signal duration during diagnostic self-tests?\u003c\/strong\u003e\u003cbr\u003e\nA2: The duration of the internal diagnostic test signal is a maximum of 200 µs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can the output channels drive indicator lamps directly?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, each output channel supports lamp loads up to 4 W with integrated safety shutdown capability.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52897114325124,"sku":"F3348","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F3348_HIMA.jpg?v=1790421866","url":"https:\/\/www.etowonauto.com\/nl\/products\/hima-f3348-safety-module-8-channel-48v-dc-output","provider":"Etowon Auto","version":"1.0","type":"link"}