{"product_id":"ge-369b1843g5003-mdi50-32-channel-digital-input-module","title":"GE 369B1843G5003 MDI50 32-Channel Digital Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eGE 369B1843G5003\u003c\/strong\u003e Nexus Digital Input Module (MDI50) provides 32 channels of high-speed switch input monitoring. It supports dry contact or sinking current signals with 48V DC query voltage. Built-in SOE (Sequence of Events) recording with 1ms accuracy makes it ideal for turbine and generator trip monitoring and fault diagnostics.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThis module accepts dry contact or sinking current inputs with 48V DC query voltage. The last 4 channels support pulse input (PI) function up to 1.5kHz. Signal filtering is firmware-configurable from 3 to 50ms (default 24ms). LED indicators provide clear status for each channel, module operation, communication, and fault alarms.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e369B1843G5003 (MDI50)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eChannels\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e32\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Signal\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDry contact or sinking current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eQuery Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSOE Accuracy\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSignal Filtering\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3~50ms adjustable (default 24ms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePI Function\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLast 4 channels, 0~1.5kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIsolation Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e500VAC (channel to ground), 1500VAC (system)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTypical 1.2W, Max 8.5W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e209 x 129.5 x 51 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApprox. 0.6 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 to 60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCertification\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCE (with system)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eMount the module using standard screw terminals (2.5mm² wire capacity). Connect dry contact or sinking current inputs to the 32 channels. For pulse input applications, use channels 29-32 (last 4 channels). Configure signal filtering via firmware based on your application requirements. Ensure proper grounding and maintain isolation distances from high-voltage lines.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThis module delivers 1ms SOE accuracy for precise event sequencing in trip analysis. The built-in PI function on the last 4 channels eliminates the need for separate frequency counters, saving cabinet space. Configurable filtering (3-50ms) allows optimization for noisy environments. With 1500VAC system isolation, this module provides reliable operation in demanding power generation applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: SOE accuracy?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e 1ms for precise trip analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Which channels support PI?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Last 4 channels (29-32), 0~1.5kHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Filtering adjustable?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Yes, 3~50ms via firmware (default 24ms).\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52710076317828,"sku":"MDI50","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/MDI50_369B1843G5003.jpg?v=1788096189","url":"https:\/\/www.etowonauto.com\/nl\/products\/ge-369b1843g5003-mdi50-32-channel-digital-input-module","provider":"Etowon Auto","version":"1.0","type":"link"}