{"product_id":"f8627-safety-system-ethernet-communication-module-hima","title":"F8627 Safety System Ethernet Communication Module | HIMA","description":"\u003ch2 style=\"color: #1A237E; font-size: 22px; font-weight: bold; margin-bottom: 12px;\"\u003eHIMA F8627 Safety System Ethernet Communication Module\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  The \u003cstrong style=\"color: #0D47A1;\"\u003e\u003cspan style=\"color: #0D47A1;\"\u003eHIMA F8627\u003c\/span\u003e\u003c\/strong\u003e is a high-reliability Ethernet communication module specifically designed to provide seamless network connectivity for HIMA safety systems. Engineered for mission-critical industrial safety applications, this module facilitates high-speed data transfer up to 100 Mbps using standard 100Base-T Ethernet via an RJ45 interface. It enables robust networking across plant safety architectures while maintaining stringent system integrity.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eKey System \u0026amp; Communication Capabilities\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  Supporting both safeethernet protocols for safety-critical controller communication and OPC DA via the HIMA OPC server for higher-level DCS\/SCADA integration, the F8627 module ensures versatile system interfacing. Designed to operate reliably in harsh industrial environments with a temperature range from -20°C to +60°C, this 24V DC powered module installs directly into standard 19-inch subracks, taking up 3 height units and 4 width units.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; color: #333333; margin-bottom: 15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eHIMA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eF8627\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eModule Function\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eEthernet Communication Module for Safety Systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eSupported Protocols\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003esafeethernet, OPC DA (via HIMA OPC Server)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e19-inch Rack-mountable; 3 HE (3 x 44.45 mm), 4 TE (4 x 5.08 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e100Base-T Ethernet with RJ45 Connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eData Transfer Rate\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eUp to 100 Mbps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e-20°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInter-Controller Safety Networking:\u003c\/strong\u003e Secure communication between distributed HIMA safety systems using safeethernet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlant Control System Integration:\u003c\/strong\u003e Data exchange with upper-level SCADA or DCS platforms via OPC DA interface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Industry Safety Monitoring:\u003c\/strong\u003e Real-time safety data transmission in chemical, oil \u0026amp; gas, and energy generation facilities.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRemote System Diagnostics:\u003c\/strong\u003e Remote monitoring and parameter access across plant-wide Ethernet networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 8px;\"\u003e\n  \u003cstrong\u003eQ1: What protocols does F8627 support?\u003c\/strong\u003e\u003cbr\u003e\n  A1: It supports safeethernet and OPC DA.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 8px;\"\u003e\n  \u003cstrong\u003eQ2: What is the physical rack size?\u003c\/strong\u003e\u003cbr\u003e\n  A2: 19-inch rack format, 3 HE and 4 TE units.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 15px;\"\u003e\n  \u003cstrong\u003eQ3: What is the module's shipping weight?\u003c\/strong\u003e\u003cbr\u003e\n  A3: It weighs approximately 2.0 kg.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eDownloads \u0026amp; Technical Contacts\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 10px;\"\u003e\n  For full technical documentation, wiring guides, or pricing information, please reach out to our team:\n\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 12px;\"\u003e\n  Contact Technical Support: \u003ca href=\"mailto:sale@etowonauto.com\" style=\"color: #D84315; font-weight: bold; text-decoration: none;\"\u003esale@etowonauto.com\u003c\/a\u003e\n\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52897252573316,"sku":"F8627","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F8627_HIMA-3.jpg?v=1790420345","url":"https:\/\/www.etowonauto.com\/nl\/products\/f8627-safety-system-ethernet-communication-module-hima","provider":"Etowon Auto","version":"1.0","type":"link"}