{"product_id":"dual-port-fip-communication-module-ge-fanuc-ic693bem341","title":"Dual Port FIP Communication Module GE Fanuc IC693BEM341","description":"\u003ch2 style=\"color: #1976d2; font-weight: bold; font-size: 1.6em; margin-bottom: 15px;\"\u003e\n  \u003cspan style=\"color: #1976d2; font-weight: bold;\"\u003eGE Fanuc IC693BEM341\u003c\/span\u003e FIP Bus Controller Module\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 1em; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  The GE Fanuc IC693BEM341 is a high-performance FIP (Factory Instrumentation Protocol) Bus Controller module designed for the Series 90-30 PLC platform. Operating at a data rate of 2.5 MHz, this module enables reliable real-time fieldbus communication between the central processor and remote FIP I\/O sub-networks. Featuring dual 9-pin D-shell FIP ports, a dedicated RS485 port for firmware upgrades, and advanced Mode 30 configuration supporting timestamping for up to 1,024 Boolean events, the IC693BEM341 provides high-speed deterministic control in a compact 225 g unit.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 0.95em;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333; width: 40%;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eGE Fanuc \/ Emerson Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eComplete Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555; font-weight: bold; color: #d32f2f;\"\u003eIC693BEM341\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eProduct Family\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eSeries 90-30 PLC System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eData Rate \u0026amp; Mode\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e2.5 MHz | Mode 30 Configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eCommunication Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e2 × 9-pin D-shell (FIP) | 1 × RS485 (Firmware Upgrades)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eTimestamp Capacity\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1,024 Boolean Events\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eBackplane Current Draw\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e0.8 A Typical | 1.2 A Maximum (from 5 VDC bus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eStatus LED Indicators\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e6 LEDs (Module OK, RUN, CD1, CD2, TEN1, TEN2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eDimensions \u0026amp; Net Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e80 × 100 × 20 mm | 0.225 kg (225 g \/ 0.50 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e0°C to +55°C (Operating) | –25°C to +70°C (Storage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eHumidity \u0026amp; Environmental Ratings\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e5% to 95% Non-condensing | Shock: 5G (10 ms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eFirmware Version \u0026amp; Configuration Time\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eVersion 3.01 | Configuration Time: \u0026lt; 15 seconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eQuick Installation Guide\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eEnsure backplane power is switched off before inserting the module into a Series 90-30 baseplate slot.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eConnect FIP network cables to the dual 9-pin D-shell ports and verify proper bus termination.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003ePower up the rack and verify that the MODULE OK and RUN LEDs illuminate green.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eDownload system configuration using standard Proficy Machine Edition or Logicmaster 90 software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ1: What is the purpose of the onboard RS485 port on the IC693BEM341?\u003c\/strong\u003e\u003cbr\u003e\n  A1: The RS485 port is specifically dedicated to downloading and updating the module's operating firmware.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ2: What do the CD1\/CD2 and TEN1\/TEN2 LED indicators signify?\u003c\/strong\u003e\u003cbr\u003e\n  A2: CD1 and CD2 indicate Carrier Detect for FIP channels 1 and 2, while TEN1 and TEN2 show Transmission Enable status.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ3: How many Boolean events can the module timestamp?\u003c\/strong\u003e\u003cbr\u003e\n  A3: The module has an integrated capacity to timestamp up to 1,024 Boolean events for sequence of events analysis.\n\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050826563716,"sku":"IC693BEM341","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693BEM341.jpg?v=1785561271","url":"https:\/\/www.etowonauto.com\/nl\/products\/dual-port-fip-communication-module-ge-fanuc-ic693bem341","provider":"Etowon Auto","version":"1.0","type":"link"}