{"product_id":"allen-bradley-22d-e019h204-frame-c-adjustable-frequency-drive-11kw","title":"Allen-Bradley 22D-E019H204 Frame C Adjustable Frequency Drive 11kW","description":"\u003ch2 style=\"color: #1976d2; font-weight: bold; font-size: 1.6em; margin-bottom: 15px;\"\u003e\n  \u003cspan style=\"color: #1976d2; font-weight: bold;\"\u003eAllen-Bradley 22D-E019H204\u003c\/span\u003e PowerFlex 40P Adjustable Frequency VFD Drive\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 1em; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  The module functions as a high-performance, compact adjustable frequency drive engineered to deliver precise motor speed and torque regulation across automated machine applications. Weighing approximately 1.40 kg, this Frame C motor controller handles 15 Horsepower (11 kW) output demands over a 600V AC three-phase input network, utilizing advanced sensorless vector control algorithms to maintain stable torque profiles at low operational velocities within a space-saving, zero-stacking plate frame layout.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 0.95em;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eProduct Model \/ Catalog No.\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e22D-E019H204\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eProduct Line Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003ePowerFlex 40P AC Drive System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eComponent Profile\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eAdjustable Frequency AC Drive (VFD)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eRated Output Power\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e15 Horsepower (HP) \/ 11 Kilowatts (kW) continuous mechanical work\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eContinuous Amperage Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e19.0 A output current capacity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003ePrimary Grid Input Power\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e600 V AC, Three-Phase (3-Phase) network loop\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eSystem Operating Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e50 Hz \/ 60 Hz tracking bandwidth range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eControl Method Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eSensorless Vector Control for enhanced low-speed torque tracking\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eMechanical Hardware Framework\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eFrame Size C structural dimensions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eEnclosure Safety Protection\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eOpen NEMA Type \/ IP20 Flange Plate Mount layout\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eOnboard Operator Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eStatus LED indicators, data programming keys, and display w\/ reset-only plate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eLine Isolation Protection\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eIntegrated relay precharge circuit and removable Metal Oxide Varistor (MOV)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eInternal Filtering Profile\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eNo integrated CE compliant filter present\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eHardware Net Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1.40 kg \/ 3.08 lbs typical balanced operational mass\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eQuick Installation Guide\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eIsolate the primary 600V AC input feed lines completely before attempting mounting, terminal configuration, or removal tasks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eSecure the 1.40 kg Frame C 22D-E019H204 plate unit onto an internal control box panel using the flexible DIN rail tracks or integrated flange mount paths.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eUtilize the zero-stacking feature if mounting adjacent drives side-by-side, maintaining ambient panel temperatures below 40°C to secure ideal convection parameters.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eComplete the high-voltage 3-phase line and field motor phase wiring, double-check that the line ground is fully bonded, power on, and input customized parameters via the embedded keypad.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ1: What are the main advantages of Sensorless Vector Control on this PowerFlex 40P drive?\u003c\/strong\u003e\u003cbr\u003e\n  A1: Sensorless vector control allows the 22D-E019H204 to accurately estimate motor speed and slip variations without requiring an external shaft encoder feedback line. This processing method regulates the current vector paths dynamically, allowing the drive to maintain high motor torque values even at very low speeds.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ2: Why is the combination of a relay precharge controller and a removable MOV critical for safety?\u003c\/strong\u003e\u003cbr\u003e\n  A2: The relay precharge controller limits the initial high inrush currents during line power-up, shielding internal filter capacitors from thermal stress. The removable Metal Oxide Varistor (MOV) attenuates sudden voltage spikes across ungrounded grid supplies, allowing engineers to disconnect the component when operating on ungrounded delta systems.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ3: How does the 1.40 kg plate drive architecture contribute to modern space-saving control schemes?\u003c\/strong\u003e\u003cbr\u003e\n  A3: At a baseline net weight of 1.40 kg, the single-slot Frame C configuration utilizes a unique flange layout that lets you recess the heatsink component out through the rear panel wall. Combined with zero-stacking capabilities, this helps optimize thermal dissipation pathways, reducing the absolute layout footprint required inside industrial electrical cabinets.\n\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047690600580,"sku":"22D-E019H204","price":167.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/22D-E019H204.jpg?v=1783000611","url":"https:\/\/www.etowonauto.com\/nl\/products\/allen-bradley-22d-e019h204-frame-c-adjustable-frequency-drive-11kw","provider":"Etowon Auto","version":"1.0","type":"link"}