{"product_id":"abb-ai931b-3kde175512l9310-s900-4-channel-hart-module","title":"ABB AI931B 3KDE175512L9310 S900 4 Channel HART Module","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eABB AI931B 3KDE175512L9310 S900 4-Channel HART Input Module\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eABB AI931B 3KDE175512L9310\u003c\/strong\u003e is an S900 series 4-channel analog input module accepting 4-20 mA signals with HART protocol support. ATEX Zone 2 certified with intrinsic safety for hazardous areas.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eAI931B 3KDE175512L9310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eS900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eSignal Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHART Support\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eZone Certification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHot Swap\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eS900 modular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eIntrinsic safety for hazardous zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eIsolation\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eElectrical isolation between channels and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eFieldbus-compatible with HART protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e±0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e±50 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eUpdate Time per Channel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eStep Response Time\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e1.5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eCurrent Consumption (24V)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e500 V AC (channel to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e124 x 25 x 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e0.15 kg (0.33 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many channels does the AI931B support?\u003c\/strong\u003e\u003cbr\u003eA1: 4 channels for 4-20 mA analog inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this module support HART communication?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, HART protocol transmission is fully supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the zone certification?\u003c\/strong\u003e\u003cbr\u003eA3: ATEX Zone 2 certified with intrinsic safety for hazardous areas.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050496491652,"sku":"AI931B","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/AI931B.jpg?v=1781346809","url":"https:\/\/www.etowonauto.com\/nl\/products\/abb-ai931b-3kde175512l9310-s900-4-channel-hart-module","provider":"Etowon Auto","version":"1.0","type":"link"}