{"product_id":"1762-l40awa-allen-bradley-controller-120vac-input-1440va-load","title":"1762-L40AWA Allen-Bradley Controller | 120VAC Input 1440VA Load","description":"\u003ch2\u003eAllen-Bradley 1762-L40AWA MicroLogix 1200 Controller\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5f7a;\"\u003eAllen-Bradley 1762-L40AWA\u003c\/strong\u003e is a 40-point programmable controller from the MicroLogix 1200 series. It features 24 inputs rated at 120 VAC and 16 relay outputs with a 24-125 VDC \/ 120-240 VAC contact rating. Powered by 120-240 VAC external supply, the controller includes 2 trim potentiometers for local control and one 8-pin mini-DIN communication port. Weight is 2.4 lbs (1.09 kg).\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f4f7fa; border: 1px solid #b8c9d6;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #b8c9d6; color: #1a2a3a;\"\u003e\n\u003cth style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e1762-L40AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eMicroLogix 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eModule Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eProgrammable Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eInput Power\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e120-240 VAC, 47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eInputs\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e24 (120 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eOutputs\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e16 Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e24-125 VDC; 120-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eMechanical Cycles\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e20,000,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eLoad Current\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e10 A minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eMax Load Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e1,440 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eCurrent per Group Common\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eOn-State Voltage (Ch 0-3)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e14-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eOn-State Voltage (Ch 4+)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e10-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e0-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eMin Off-State Leakage\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eCommunication Port\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e1 x 8-Pin mini-DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eDF1, DH-485, ASCII, MODBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003ePower Supply Usage\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e82 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eInrush Current (120V AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e25 A for 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eInrush Current (240V AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e40 A for 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e90 x 160 x 87 mm (104 mm with DIN latch open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e0 to 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e2.4 lbs (1.09 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eUPC\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e10612598207227\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003e40-point controller with 24 inputs and 16 relay outputs\u003c\/li\u003e\n\u003cli\u003e120 VAC input rating with 120-240 VAC power supply\u003c\/li\u003e\n\u003cli\u003eRelay contact rating 24-125 VDC \/ 120-240 VAC\u003c\/li\u003e\n\u003cli\u003e20,000,000 mechanical cycle relay rating\u003c\/li\u003e\n\u003cli\u003eMax load capacity 1,440 VA with 8 A per group common\u003c\/li\u003e\n\u003cli\u003eTwo trim potentiometers for local control\u003c\/li\u003e\n\u003cli\u003eOne 8-pin mini-DIN communication port\u003c\/li\u003e\n\u003cli\u003eSupports DF1, DH-485, ASCII, and MODBUS protocols\u003c\/li\u003e\n\u003cli\u003eOperating frequency 47-63 Hz\u003c\/li\u003e\n\u003cli\u003eCompact design with 2-inch clearance requirement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eSupply external 100-240 VAC power at 47-63 Hz. Ensure output load does not exceed 8 A per group common to prevent module damage. The inrush current is 25 A for 8 ms at 120 VAC and 40 A for 4 ms at 240 VAC. Use the 8-pin mini-DIN port for program download\/upload, HMI, and SCADA interfacing. Trim potentiometers located on the front panel can be adjusted with a precision screwdriver for local control.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ1:\u003c\/strong\u003e How many I\/O points does the 1762-L40AWA have?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA1:\u003c\/strong\u003e 24 inputs (120 VAC) and 16 relay outputs, totaling 40 I\/O channels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ2:\u003c\/strong\u003e What is the maximum load capacity?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA2:\u003c\/strong\u003e Up to 1,440 VA, with a maximum of 8 A per group common.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ3:\u003c\/strong\u003e What communication protocols are supported?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA3:\u003c\/strong\u003e DF1, DH-485, ASCII, and MODBUS Master\/Slave protocol.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67603768017028,"sku":"1762-L40AWA","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1762-L40BWA-1.jpg?v=1791259174","url":"https:\/\/www.etowonauto.com\/nl\/products\/1762-l40awa-allen-bradley-controller-120vac-input-1440va-load","provider":"Etowon Auto","version":"1.0","type":"link"}