{"title":"Relays \u0026 Switches","description":"\u003cp\u003eRelays \u0026amp; Switches provide essential control and automation functions, supporting electrical isolation, signaling, and switching in industrial environments. Each component is tested for reliability and long-term performance.\u003c\/p\u003e","products":[{"product_id":"3500-33-01-cn-bently-nevada-relay-module-16-channel-output","title":"3500\/33-01-CN Bently Nevada Relay Module - 16 Channel Output","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cspan style=\"color:#00529b;font-weight:700;\"\u003eBently Nevada 3500\/33-01-CN 149992-01\u003c\/span\u003e is a 16-channel relay module for 3500 rack systems. It provides alarm and trip outputs for turbines, compressors, and pumps in critical machinery protection applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e – 16-Channel Relay Module.\u003cbr\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e – Standard 16-Channel Relay Output.\u003cbr\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e – Country-specific approvals (China).\u003cbr\u003e\nFour groups of four channels, switch-selectable for Normally De-energized (ND) or Normally Energized (NE) operation.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;\"\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eSPDT, epoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eContact Ratings\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e5A @ 250Vac \/ 5A @ 125Vdc (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMin. Switched Load\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e100mA @ 5Vdc (standard) \/ 1mA @ 1Vdc (gold)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMax Switched Power (DC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMax Switched Power (AC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e1200VA @ 250Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eContact Life\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eArc Suppressor\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e250 Vrms (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eStorage Temp.\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e0.7 kg (1.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eRack Space\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eSet each 4-channel group for ND or NE via onboard switches. Use shielded cables for field wiring. For hazardous areas, observe voltage restrictions (30 Vrms max for CSA-only; lower for multiple approvals). Set initial gap voltage to -10 Vdc for standard 3300 XL probes.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eEpoxy-sealed contacts resist dust and corrosion. The module supports SIL-rated safety functions when used with restricted voltage. Seamless integration with 3500 TSI systems and backward-compatible with older 3300 racks (software v3.3+).\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How to check ND vs NE operation?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Measure coil voltage. ND = de-energized in normal state; NE = energized in normal state. Front-panel CH Alarm LED confirms channel status.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What does -CN approval limit?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e The -CN suffix indicates China-specific approvals. It may impose lower maximum voltage limits than standard. Refer to the certificate for exact ratings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can it replace older 3300\/33 modules?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Yes, with rack configuration v3.3+ and Data Acquisition v2.40+. The module is fully backward-compatible.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047650328708,"sku":"3500\/33-01-CN","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33-01-00_149992-01.jpg?v=1787404535"},{"product_id":"1756-on8-controllogix-2a-per-point-ac-switching-allen-bradley","title":"1756-ON8 ControlLogix | 2A per point AC Switching Allen-Bradley","description":"\u003ch2\u003eAllen-Bradley 1756-ON8 ControlLogix AC Output Module\u003c\/h2\u003e\n\u003ch3\u003e8-Point 240V AC Digital Output Module\u003c\/h3\u003e\n\u003ch4\u003eModule Highlights\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e8-point AC output module for industrial control\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003e240V AC rating\u003c\/span\u003e (10-30V AC operating range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003e2A per point\u003c\/span\u003e output capacity (4A total @60°C)\u003c\/li\u003e\n\u003cli\u003eCompact design fits standard ControlLogix chassis\u003c\/li\u003e\n\u003cli\u003eLED status indicators for easy monitoring\u003c\/li\u003e\n\u003cli\u003eWeight: \u003cspan style=\"color: #c00000;\"\u003e0.28 kg (0.62 lbs)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePerformance Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e AC voltage switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Speed:\u003c\/strong\u003e 9.3ms (60Hz) \/ 11ms (50Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 2A per point (5A module total @30°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5.1W max @60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 50V continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power:\u003c\/strong\u003e 200mA @5.1V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironmental Ratings\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 2G (10-500Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Rating:\u003c\/strong\u003e 30G operational\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePackage Includes\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003e1756-ON8\u003c\/strong\u003e AC Output Module\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eTerminal labels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eShipping\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx, UPS, DHL worldwide shipping\u003c\/li\u003e\n\u003cli\u003eExpedited options available\u003c\/li\u003e\n\u003cli\u003eAnti-static protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output points?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Eight (8) AC output points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the current rating per point?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 2A per point at 240V AC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What terminal blocks are compatible?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 1756-TBNH or 1756-TBSH terminal blocks.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047657144452,"sku":"1756-ON8","price":226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1756-ON8.jpg?v=1775572508"},{"product_id":"allen-bradley-1783-bms10cl-stratix-5700-managed-switch","title":"Allen-Bradley 1783-BMS10CL Stratix 5700 Managed Switch","description":"\u003ch2 style=\"color: #003366; font-weight: bold;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003eThe Allen-Bradley \u003cstrong\u003e1769-SM1\u003c\/strong\u003e is a robust Compact I\/O communication module designed to provide a direct interface between controllers and industrial drives. Specifically engineered for the PowerFlex family, the \u003cstrong\u003e1769-SM1\u003c\/strong\u003e supports both DPI and SCANport protocols, allowing for seamless data exchange and high-speed control. \u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3 style=\"color: #0055aa; margin-top: 20px;\"\u003eIntelligent Auto-Detection\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eThe \u003cstrong\u003e1769-SM1\u003c\/strong\u003e features advanced self-configuration capabilities. Upon power-up, the module automatically detects the connected DPI or SCANport host and adjusts its internal data rate to match the host device. This \"plug-and-play\" functionality significantly reduces commissioning time and minimizes the risk of manual configuration errors in complex network topologies.\u003c\/p\u003e\n\u003ch3 style=\"color: #0055aa; margin-top: 20px;\"\u003eAdvanced I\/O Messaging\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eEquipped with multi-channel support, the \u003cstrong\u003e1769-SM1\u003c\/strong\u003e enables sophisticated bi-directional datalinks. It facilitates Logic Command and Reference signaling for each connected channel, ensuring that critical control parameters are transmitted with high precision. This messaging architecture supports comprehensive drive software tools, including DriveExplorer and DriveExecutive, for intuitive remote setup.\u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; border: 1px solid #dddddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 12px; text-align: left; color: #003366;\"\u003eAttribute\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 12px; text-align: left; color: #003366;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e\u003cstrong\u003e1769-SM1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eInterface Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eDPI and SCANport\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eController Compatibility\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eCompactLogix, MicroLogix 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003ePower Supply Distance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e8 Modules (Rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBackplane Placement:\u003c\/strong\u003e The \u003cstrong\u003e1769-SM1\u003c\/strong\u003e has a power supply distance rating of 8. Ensure the module is installed within 8 slots of the system power supply to maintain adequate voltage levels.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain an operating environment between 0°C and 60°C. Ensure sufficient cabinet ventilation, especially when multiple \u003cstrong\u003e1769-SM1\u003c\/strong\u003e modules are used in a single rack.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCable Integrity:\u003c\/strong\u003e Use high-quality communication cables to connect the \u003cstrong\u003e1769-SM1\u003c\/strong\u003e to the drive host. Improper shielding or excessive cable length can lead to signal interference and communication drops.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eFirmware Synchronization:\u003c\/strong\u003e Regularly check for firmware updates to ensure compatibility between the \u003cstrong\u003e1769-SM1\u003c\/strong\u003e and the latest PowerFlex drive features.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eThe \u003cstrong\u003e1769-SM1\u003c\/strong\u003e provides a localized, high-speed solution for drive control that bypasses the latency of traditional fieldbus adapters. By integrating directly into the 1769 I\/O chassis, it allows for faster Logic Reference updates and more responsive motor control. For engineers utilizing RSNetWorx for DeviceNet or PowerFlex HIM modules, the \u003cstrong\u003e1769-SM1\u003c\/strong\u003e serves as an essential hardware link that unifies configuration and operation into a single, cohesive industrial network.\u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\u003cstrong\u003eQ1: Can the 1769-SM1 be used with older SCANport drives?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, the \u003cstrong\u003e1769-SM1\u003c\/strong\u003e is backwards compatible and can automatically detect and configure itself for SCANport hosts as well as modern DPI interfaces.\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 10px;\"\u003e\u003cstrong\u003eQ2: Does this module support bi-directional data exchange?\u003c\/strong\u003e\u003cbr\u003eA2: Absolutely. The \u003cstrong\u003e1769-SM1\u003c\/strong\u003e facilitates bi-directional I\/O messaging, allowing for both the sending of control commands and the retrieval of real-time drive diagnostics.\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 10px;\"\u003e\u003cstrong\u003eQ3: What software is required to configure the 1769-SM1?\u003c\/strong\u003e\u003cbr\u003eA3: The \u003cstrong\u003e1769-SM1\u003c\/strong\u003e is compatible with standard Rockwell Automation tools, including DriveExplorer, DriveExecutive, and RSNetWorx for DeviceNet.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047660191876,"sku":"1769-SM1","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1769-SM1-1.jpg?v=1776577279"},{"product_id":"allen-bradley-1783-bms10cl-stratix-5700-switch","title":"Allen-Bradley 1783-BMS10CL Stratix 5700 Switch","description":"\u003ch2 style=\"color: #003366; font-weight: bold;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\n    The Allen-Bradley \u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e is a high-performance Stratix 5700 managed Ethernet switch designed for rugged industrial environments. Featuring \"Lite\" firmware, it provides essential network management—including VLANs and port security—without unnecessary complexity. This 10-port switch ensures high availability and optimized data traffic for machine-level networks, making the \u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e an ideal choice for reliable plant-floor connectivity.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3 style=\"color: #0055aa; margin-top: 20px;\"\u003eVersatile Port Density\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003e\n    The hardware layout for the \u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e includes 8 dedicated Fast Ethernet copper ports and 2 Combo ports, totaling 10 active copper interfaces. This setup provides flexible connectivity for PLCs, HMIs, and I\/O blocks within a single compact enclosure.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #0055aa; margin-top: 20px;\"\u003eIndustrial-Grade Resilience\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003e\n    Built for harsh conditions, the \u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e features a fanless design and advanced heat dissipation. It excels in high-vibration and electrically noisy environments, ensuring stable performance inside tight control cabinets.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; border: 1px solid #dddddd;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n            \u003cth style=\"border: 1px solid #dddddd; padding: 12px; text-align: left; color: #003366;\"\u003eAttribute\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #dddddd; padding: 12px; text-align: left; color: #003366;\"\u003eDetails\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eBrand\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eStratix 5700\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e\u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eFirmware Type\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eLite Management\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eTotal Port Count\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e10 Ports\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eCopper Ports\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e10 x RJ45 (8 FE + 2 Combo)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e24\/48V DC (Range: 12-60V DC)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eMounting\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e35mm DIN Rail\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e1.22 kg (2.7 lbs)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the \u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e to a 35mm DIN rail with 2 inches of clearance above and below for cooling.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Connect dual DC inputs for power redundancy to ensure continuous uptime.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Use a low-impedance ground bus to protect the \u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e against EMI and signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003e\n    The \u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e integrates seamlessly with Studio 5000 via Add-On Profiles (AOPs), allowing for direct configuration and monitoring. Its optimized footprint and Lite firmware provide a cost-effective solution for machine builders requiring managed network control without the overhead of enterprise-level software.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\n    \u003cstrong\u003eQ1: Does the 1783-BMS10CL support SFP fiber modules?\u003c\/strong\u003e\u003cbr\u003e\n    A1: No. This model is strictly copper-based. The combo ports support RJ45 copper connections only.\n\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 10px;\"\u003e\n    \u003cstrong\u003eQ2: Can I use this switch for DLR (Device Level Ring) supervisor tasks?\u003c\/strong\u003e\u003cbr\u003e\n    A2: No. The Lite firmware on the \u003cstrong\u003e1783-BMS10CL\u003c\/strong\u003e does not support DLR. For ring redundancy features, a \"Full\" firmware model is required.\n\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 10px;\"\u003e\n    \u003cstrong\u003eQ3: Is the firmware on the 1783-BMS10CL upgradable to the \"Full\" version?\u003c\/strong\u003e\u003cbr\u003e\n    A3: No. The firmware level is hardware-dependent and cannot be upgraded via software on this unit.\n\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047661305988,"sku":"1783-BMS10CL","price":128.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1783-BMS10CL-2.jpg?v=1776576065"},{"product_id":"bently-nevada-3500-33-01-01-16-channel-relay-module","title":"Bently Nevada 3500\/33-01-01 16-Channel Relay Module","description":"\u003ch2\u003eBently Nevada 3500\/33-01-01 16-Channel Relay Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eBently Nevada 3500\/33-01-01\u003c\/strong\u003e 3500\/33 16-Channel Relay Output Module. Provides 16 independent SPDT relay outputs for machinery protection systems. Epoxy-sealed relays with arc suppressors ensure reliable operation in demanding industrial environments. cNRTLus certified for Class I Division 2 hazardous areas.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e16 SPDT relay outputs. Epoxy-sealed environmental sealing. 250 Vrms arc suppressor standard. Four groups of four channels with switch-selectable Normally De-energized (ND) or Normally Energized (NE) operation. Front panel OK, TX\/RX, and CH Alarm LEDs. 5.8W typical power consumption. Main module 0.7 kg, I\/O module 0.4 kg.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3500\/33-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3500\/33 16-Channel Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Module (A)\u003c\/td\u003e\n\u003ctd\u003e01 = 16-Channel Relay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Option (B)\u003c\/td\u003e\n\u003ctd\u003e01 = cNRTLus (Class I Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSingle-pole Double-throw (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sealing\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Operation\u003c\/td\u003e\n\u003ctd\u003e4 groups of 4, switch-selectable ND\/NE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space (Main)\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space (I\/O)\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContact Ratings\u003c\/h3\u003e\n\u003ch4\u003eStandard Relays\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power (DC)\u003c\/td\u003e\n\u003ctd\u003e70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power (AC)\u003c\/td\u003e\n\u003ctd\u003e1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFailsafe \/ Hazardous Area Systems\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eLow Current Applications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Code Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33-01-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e – 16-Channel Relay Module.\u003cbr\u003e\u003cstrong\u003eA:01\u003c\/strong\u003e – 16-Channel Relay Output Module.\u003cbr\u003e\u003cstrong\u003eB:01\u003c\/strong\u003e – cNRTLus (Class I Division 2) hazardous area approval.\u003c\/p\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstall main module in full-height front slot. Install I\/O module in corresponding rear slot. Configure relay groups for ND or NE operation via switches. Observe contact rating limits for standard, failsafe, or low current applications. Ensure proper grounding per Bently Nevada guidelines.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e16 independent relay outputs provide flexible alarm and control signaling. Epoxy-sealed relays withstand harsh industrial environments. Arc suppressors extend contact life and reduce EMI. cNRTLus certification enables installation in Class I Division 2 hazardous areas. Switch-selectable ND\/NE per group simplifies integration with existing control schemes.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How many relay outputs does this module provide?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 16 independent SPDT relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What are the contact ratings for standard applications?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 5A max, 125Vdc or 250Vac, 70W @ 24Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the relay operation configuration?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Four groups of four channels, switch-selectable for Normally De-energized or Normally Energized operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047900053636,"sku":"3500\/33-01-01","price":286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33-01-01.jpg?v=1787491741"},{"product_id":"3500-33-01-r0-bently-nevada-relay-output-module","title":"3500\/33-01-R0 Bently Nevada Relay Output Module","description":"\u003ch2\u003eBently Nevada 3500\/33-01-R0 16-Channel Relay Module\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5276;\"\u003eBently Nevada 3500\/33-01-R0\u003c\/strong\u003e is a full-height 16-Channel Relay Module for 3500 rack systems. Each output can be independently programmed with alarm drive logic using AND\/OR logic and voting based on alarming inputs, Not-OK signals, and measured variables from any monitor channel.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e 3500\/33-01-R0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 16-Channel Relay Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Position:\u003c\/strong\u003e Any slot to the right of TDI Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eModel Number Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33 AA-BB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e – 16-Channel Relay Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR0\u003c\/strong\u003e – Hazardous Area Approval: cNRTLus (Class 1, Division 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 60%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e241 mm (9.50 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e24.4 mm (0.96 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e242 mm (9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e0.7 kg (1.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eContact Life\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Current (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Voltage (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Current (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Voltage (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eHazardous Area Approval\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ecNRTLus (Class 1, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAlarm Drive Logic\u003c\/h3\u003e\n\u003cp\u003eEach relay includes programmable alarm drive logic using AND and OR logic, incorporating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAlarming inputs (alert and danger statuses)\u003c\/li\u003e\n\u003cli\u003eNot-OK signals\u003c\/li\u003e\n\u003cli\u003eIndividual measured variables from any monitor channel or combination\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in any full-height slot to the right of TDI Module.\u003c\/li\u003e\n\u003cli\u003eEach relay channel can be independently programmed.\u003c\/li\u003e\n\u003cli\u003eFour groups of four channels available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What does R0 indicate in the model number?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e R0 indicates cNRTLus hazardous area approval for Class 1, Division 2 locations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Can each relay be programmed independently?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Yes. Each of the 16 relay outputs has independent alarm drive logic programming.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Where can this module be installed in the rack?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Any full-height slot to the right of the Transient Data Interface (TDI) Module.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047900086404,"sku":"3500\/33-01-R0","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33-01-R0.jpg?v=1784470506"},{"product_id":"abb-3bse013250r1-digital-output-module-3a-relay","title":"ABB 3BSE013250R1 Digital Output Module | 3A Relay","description":"\u003ch2\u003eABB 3BSE013250R1 Relay Output Module for S800 I\/O Systems\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eDO821\u003c\/strong\u003e delivers high-power relay control for industrial automation applications. This robust module provides eight isolated relay outputs handling up to 250V AC\/DC. It features comprehensive protection and reliable operation in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDO821\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eArticle Number: \u003cstrong\u003e3BSE013250R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput Channels: 8 relay outputs\u003c\/li\u003e\n\u003cli\u003eVoltage Range: 5-250V AC\/DC operating range\u003c\/li\u003e\n\u003cli\u003eCurrent Capacity: 3A per channel continuous\u003c\/li\u003e\n\u003cli\u003eContact Configuration: Normally Closed (NC)\u003c\/li\u003e\n\u003cli\u003ePower Dissipation: 2.9W typical operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Type: Relay contacts with individual isolation\u003c\/li\u003e\n\u003cli\u003eMaximum Voltage: 250V AC\/DC working voltage\u003c\/li\u003e\n\u003cli\u003eDielectric Strength: 2000V AC test voltage\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 60mA at +5V ModuleBus\u003c\/li\u003e\n\u003cli\u003eRelay Power: 140mA at +24V ModuleBus\u003c\/li\u003e\n\u003cli\u003eField Wiring: 600 meters maximum cable length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection and Safety Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e86ab;\"\u003eIndividual channel isolation\u003c\/span\u003e for maximum safety\u003c\/li\u003e\n\u003cli\u003eEMC protection components on all outputs\u003c\/li\u003e\n\u003cli\u003eOptical isolation barriers for noise immunity\u003c\/li\u003e\n\u003cli\u003eRelay power supply voltage monitoring\u003c\/li\u003e\n\u003cli\u003eBuilt-in surge protection for output channels\u003c\/li\u003e\n\u003cli\u003eIP20 protection against dust and contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to +55°C range\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40°C to +70°C limits\u003c\/li\u003e\n\u003cli\u003eHumidity Range: 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003ePollution Degree: Level 2 classification\u003c\/li\u003e\n\u003cli\u003eCorrosion Protection: ISA-S71.04 G3 rating\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP20 according to IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 119mm H × 45mm W × 102mm D\u003c\/li\u003e\n\u003cli\u003eWeight: 0.23 kg module weight\u003c\/li\u003e\n\u003cli\u003eMounting: Standard DIN rail installation\u003c\/li\u003e\n\u003cli\u003eConnector Depth: 111mm including connections\u003c\/li\u003e\n\u003cli\u003eProtection: IP20 for industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with S800 I\/O mounting units\u003c\/li\u003e\n\u003cli\u003eWorks with \u003cstrong\u003eTU811\u003c\/strong\u003e, \u003cstrong\u003eTU813\u003c\/strong\u003e, \u003cstrong\u003eTU831\u003c\/strong\u003e MTUs\u003c\/li\u003e\n\u003cli\u003eKeying code CA for proper installation\u003c\/li\u003e\n\u003cli\u003eStandard rail mounting for easy setup\u003c\/li\u003e\n\u003cli\u003eMaximum ambient temperature: 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does Normally Closed (NC) relay mean?\u003c\/strong\u003e\u003cbr\u003eNC contacts remain closed when de-energized and open when activated for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does individual channel isolation help?\u003c\/strong\u003e\u003cbr\u003eIsolation prevents interference between channels and allows different voltage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat diagnostic features are available?\u003c\/strong\u003e\u003cbr\u003eThe module provides LED status indicators and ModuleBus communication for monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047902969988,"sku":"3BSE013250R1","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3BSE013250R1.jpg?v=1763391032"},{"product_id":"800h-jr2a-allen-bradley-maintained-knob-switch-1no-1nc","title":"800H-JR2A Allen-Bradley Maintained Knob Switch 1NO 1NC","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e800H-JR2A\u003c\/strong\u003e is a commercial-grade, heavy-duty 3-position industrial selector switch from the premium 800H product family manufactured by Allen-Bradley (Rockwell Automation). Purpose-built to provide dependable manual control segmentation within severe and highly corrosive process environments, this non-illuminated control unit features a distinct black plastic knob operator. Utilizing a secure maintained\/latched action across all three indexed states, the compact \u003cstrong style=\"color: #0056b3;\"\u003e0.132 kg (0.29 lbs)\u003c\/strong\u003e component comes pre-configured with a reliable 1NO (Normally Open) \/ 1NC (Normally Closed) contact block arrangement to orchestrate instantaneous logical switching sequences.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Structural Build:\u003c\/strong\u003e Molded from a specialized glass-filled nylon (PA6\/PA66) bezel compound that delivers exceptional chemical shielding and structural rigidity, making it ideal for harsh marine, water treatment, and chemical processing setups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintained 3-Position Multi-Loop Indexing:\u003c\/strong\u003e Features an explicit 0° to 60° operational displacement path that firmly latches into the Left, Center, or Right positions, preventing accidental state changes caused by machinery vibrations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Mechanical Longevity:\u003c\/strong\u003e Engineered to withstand rigorous physical deployment cycles, with a verified service rating of up to 200,000 continuous mechanical switching operations before requiring component service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtreme Environmental Hardening:\u003c\/strong\u003e Formulated to operate reliably under punishing physical stress profiles, surviving sudden high-impact shocks up to 100g (11 ms duration) and handling intense vibration frequencies up to 2000 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Catalog Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e800H-JR2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Line Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAllen-Bradley 800H Heavy Duty Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperator Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e3-Position, Maintained \/ Latched Action Block\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eContact Block Profile\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1NO (Normally Open) and 1NC (Normally Closed) Array\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePhysical Net Mass\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.132 kg (approx. 0.29 lbs) lightweight block\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eBezel Material Composition\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGlass-Filled Nylon \/ PA6 \/ PA66 Industrial Polymer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperational Travel Angle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0° to 60° indexing sweep trajectory\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eThermal Operating Window\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e–40°C to 55°C (–40°F to 131°F) continuous ambient\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eRelative Humidity Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e50% to 95% RH non-condensing moisture scale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMechanical Shock Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e100g peak acceleration over an 11 ms duration window\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrial Solutions\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChemical Processing Stations:\u003c\/strong\u003e Resists breakdown from chemical splashes and caustic cleaning agents thanks to its glass-filled nylon construction, keeping local manual control nodes fully operational.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Treatment Control Cabinets:\u003c\/strong\u003e Provides steady state selection for motorized valves and intake pumps in highly humid control environments (up to 95% RH) without moisture-induced tracking path failures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePetrochemical Processing:\u003c\/strong\u003e Delivers exceptional physical endurance in heavy oil refining facilities, withstanding outdoor sub-zero shifts down to –40°C and sudden high-vibration engine shocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomated Production Tooling:\u003c\/strong\u003e Acts as a distinct visual and physical selector for Hand\/Off\/Auto (HOA) operation sequences, allowing maintenance teams to isolate control inputs during tooling changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003ch3\u003eCircuit Isolation Protocols\u003c\/h3\u003e\n\u003cp\u003eIsolate all primary and secondary high-voltage control circuit buses before beginning structural panel installation. Mount the 800H operator assembly firmly into a standard 30.5 mm environmental cutout. Ensure the internal sealing gaskets are seated flat against the panel faceplate to maintain a tight seal.\u003c\/p\u003e\n\n\u003ch3\u003eContact Block Wiring Parameters\u003c\/h3\u003e\n\u003cp\u003eTerminate the incoming control logic wires securely to the designated contact block terminal screws. Wire the 1NO contact pair to your active run-command circuits and the 1NC contact set to your interlocking or status monitoring indicators. Do not exceed the maximum rated installation tightening torque, as this can crack the plastic module shell.\u003c\/p\u003e\n\n\u003ch3\u003eEnvironmental Clearance and Gasketing\u003c\/h3\u003e\n\u003cp\u003eVerify that the rear terminal housing has sufficient free clearance from adjacent components inside the wiring duct or junction box. When deploying this switch in wet or washdown locations, use the provided corrosion-resistant sealing ring to block water ingress along the back of the panel plate.\u003c\/p\u003e\n\n\u003ch3\u003eVibration Hardening Verification\u003c\/h3\u003e\n\u003cp\u003eIn high-vibration applications like drilling rigs or heavy crushing plants, check that the rear contact block latch mechanism is fully locked onto the operator throat. Periodically check terminal screw tightness to prevent signal dropping caused by ongoing mechanical vibrations up to 10 m\/s².\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty NEMA 4X Compatibility:\u003c\/strong\u003e Designed to meet demanding Type 4\/4X\/13 enclosure specifications when correctly mounted, blocking water jets, dust particles, and corrosive elements from reaching the contacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTactile Black Knob Operator:\u003c\/strong\u003e Features a high-contrast black knob that gives field technicians clear visual feedback on the switch's position, even from a distance or in low light.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Contact Block Stacking:\u003c\/strong\u003e The flexible 800H operator design allows for easy removal or expansion of contact blocks, making it simple to adapt to custom field modifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the benefit of a \"maintained\" selector switch versus a \"spring return\" configuration?\u003c\/strong\u003e\u003cbr\u003e\nA1: A maintained switch stays in the position selected by the operator until turn manually to a different state. Spring return versions automatically snap back to a default center position when released, making maintained models ideal for setting long-term operation modes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why does the 0.132 kg weight profile matter when configuring dense industrial control panels?\u003c\/strong\u003e\u003cbr\u003e\nA2: The light 0.132 kg weight ensures that deploying dozens of these devices across a single hanging enclosure door won't cause structural sagging, hinge distortion, or alignment issues over time.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can this selector switch be deployed safely in extreme cold-storage facilities?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes. The 800H-JR2A is fully rated to operate reliably down to –40°C (–40°F), allowing it to handle freezing conditions in commercial ice production, cold storage warehouses, and outdoor arctic environments.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047915454596,"sku":"800H-JR2A","price":155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/800H-JR2A-1.jpg?v=1780323071"},{"product_id":"woodward-8440-2165-voltage-current-monitoring-relay","title":"Woodward 8440-2165 Voltage Current Monitoring Relay","description":"\u003ch2\u003e\u003cstrong\u003eElectrical System Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #ff9800;\"\u003eWoodward 8440-2165\u003c\/strong\u003e relay protects industrial equipment. This Woodward device provides reliable electrical monitoring.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Input:\u003c\/strong\u003e 100 VAC measurement capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input:\u003c\/strong\u003e ..\/5 A for current transformers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 45-65 Hz operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSync Accuracy:\u003c\/strong\u003e ±0.1 Hz precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20°C to 60°C operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 115\/230 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Over\/undervoltage, phase failure, ground fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced \u003cstrong style=\"color: #0066cc;\"\u003eprotection features\u003c\/strong\u003e for system safety\u003c\/li\u003e\n\u003cli\u003eWide temperature range for reliable operation\u003c\/li\u003e\n\u003cli\u003ePanel or standalone mounting options\u003c\/li\u003e\n\u003cli\u003eCompact 216x165x89 mm size\u003c\/li\u003e\n\u003cli\u003eDual power supply compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e relay per box\u003c\/li\u003e\n\u003cli\u003eIncludes user manual\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eTracking provided after dispatch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the Woodward 8440-2165 do?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e monitors voltage and current. It protects equipment from electrical faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat frequency range does it support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt works with 45-65 Hz systems. This covers 50 Hz and 60 Hz power grids.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I mount this relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse panel mounting for control cabinets. Choose standalone for test setups.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51047916339332,"sku":"8440-2165","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8440-2165-1.jpg?v=1769239136"},{"product_id":"emerson-epro-a6740-relay-module-16-channel","title":"Emerson EPRO A6740 Relay Module | 16-Channel","description":"\u003ch2\u003e\u003cb\u003eEmerson EPRO A6740 Relay Module\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cb\u003eEmerson EPRO A6740\u003c\/b\u003e is a high-density 16-channel relay module. It provides reliable switching for industrial control and automation systems.\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eCore Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBrand \u0026amp; Model:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003eEmerson EPRO A6740\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eChannels:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e16 isolated outputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eContact Rating:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e2A @ 250V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWeight:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e320 grams\u003c\/span\u003e (net)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eResponse Time:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u0026lt; 10ms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectrical Life:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e100,000 operations\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Temp:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e0°C to 65°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e54.46 × 128.4 × 160 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting:\u003c\/b\u003e DIN rail (EN 60715)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d9534f;\"\u003e16-channel\u003c\/span\u003e high-density design\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d9534f;\"\u003e320g\u003c\/span\u003e lightweight compact module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d9534f;\"\u003e2A\/250V AC\u003c\/span\u003e contact rating\u003c\/li\u003e\n\u003cli\u003eFast \u003cspan style=\"color: #d9534f;\"\u003e\u0026lt; 10ms\u003c\/span\u003e switching\u003c\/li\u003e\n\u003cli\u003eLong \u003cspan style=\"color: #d9534f;\"\u003e100,000\u003c\/span\u003e operation life\u003c\/li\u003e\n\u003cli\u003eFor Emerson EPRO MX Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003ePackage Contents\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cb\u003eEmerson EPRO A6740\u003c\/b\u003e module\u003c\/li\u003e\n\u003cli\u003eMounting clip set\u003c\/li\u003e\n\u003cli\u003eInstallation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eFAQ\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eWhat is the contact rating?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eEach relay channel handles \u003cspan style=\"color: #d9534f;\"\u003e2A at 250V AC\u003c\/span\u003e. It is suitable for controlling motors, valves, and solenoids.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHow long does it last?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe module has an electrical life of \u003cspan style=\"color: #d9534f;\"\u003e100,000 operations\u003c\/span\u003e per channel under rated load.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhat controllers is it for?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eA6740\u003c\/b\u003e is designed for use with Emerson EPRO MX Series controllers and standard PLC systems.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/Protection_Cards_for_AMS_6500_Classic_Systems.pdf?v=1749023994\" target=\"_blank\"\u003eDownload Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51047924269188,"sku":"A6740","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/A6740_1.jpg?v=1770208670"},{"product_id":"emerson-epro-a6740-10-relay-module-16-channel","title":"Emerson EPRO A6740-10 Relay Module | 16-Channel","description":"\u003ch2\u003e\u003cb\u003eEmerson EPRO A6740-10 Relay Module\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cb\u003eEmerson EPRO A6740-10\u003c\/b\u003e is a 16-channel relay module. It provides reliable control for industrial automation and protection systems.\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eCore Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBrand \u0026amp; Model:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003eEmerson EPRO A6740-10\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eChannels:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e16 isolated relays\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Temp:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e0°C to 65°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions:\u003c\/b\u003e 160×128.4×54.46 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWeight:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e320g\u003c\/span\u003e (net), \u003cspan style=\"color: #d9534f;\"\u003e450g\u003c\/span\u003e (gross)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting:\u003c\/b\u003e DIN rail (35mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePanel Space:\u003c\/b\u003e 3 HE vertical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d9534f;\"\u003e16-channel\u003c\/span\u003e isolated output\u003c\/li\u003e\n\u003cli\u003eDIN rail snap-on mounting\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistant\u003c\/li\u003e\n\u003cli\u003eCompatible with Emerson MX-series\u003c\/li\u003e\n\u003cli\u003eWorks with 24V\/48V DC systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eShipping \u0026amp; Warranty\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx, UPS, DHL shipping\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d9534f;\"\u003e1-year\u003c\/span\u003e warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eFAQ\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eWhat controllers use this module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eA6740-10\u003c\/b\u003e works seamlessly with Emerson EPRO MX-series industrial controllers and monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHow many control outputs does it have?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis module provides \u003cspan style=\"color: #d9534f;\"\u003e16 fully isolated relay channels\u003c\/span\u003e for alarm, trip, or sequence control.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhat is the physical size?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIt measures 160×128.4×54.46 mm and requires \u003cspan style=\"color: #d9534f;\"\u003e3 HE\u003c\/span\u003e of vertical panel space in a standard rack.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/Protection_Cards_for_AMS_6500_Classic_Systems.pdf?v=1749023994\" target=\"_blank\"\u003eDownload Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51047924301956,"sku":"A6740-10","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/A6740-10.jpg?v=1770125774"},{"product_id":"emerson-epro-16-channel-relay-card-a6740-12","title":"Emerson EPRO 16-Channel Relay Card A6740-12","description":"\u003ch2\u003e\u003cb\u003eEmerson EPRO A6740-12 Relay Module\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cb\u003eEmerson EPRO A6740-12\u003c\/b\u003e is a robust 16-channel relay module. It provides reliable control outputs for industrial monitoring and protection systems.\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBrand \u0026amp; Model:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003eEmerson EPRO A6740-12\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOutput Channels:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e16-channel relay\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Temperature:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e0°C to 65°C\u003c\/span\u003e (32°F to 149°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Temperature:\u003c\/b\u003e -40°C to 70°C (-40°F to 158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModule Dimensions:\u003c\/b\u003e 160mm L × 60mm W × 128.4mm H\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModule Weight:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e320 grams\u003c\/span\u003e (net)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePackage Weight:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e450 grams\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting Format:\u003c\/b\u003e DIN 41494 Eurocard (3HE\/12TE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHumidity Tolerance:\u003c\/b\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #d9534f;\"\u003e16 independent relay channels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eRobust DIN rail mounting design\u003c\/li\u003e\n\u003cli\u003eHigh vibration resistance: 0.15mm @ 10-55Hz\u003c\/li\u003e\n\u003cli\u003eShock resistant: 98m\/s² (9.98g) for 16ms\u003c\/li\u003e\n\u003cli\u003eTool-free spring-clip terminal connections\u003c\/li\u003e\n\u003cli\u003eCompatible with MMS6000\/AMS6500 systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003ePackage Contents\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cb\u003eEmerson EPRO A6740-12\u003c\/b\u003e relay module\u003c\/li\u003e\n\u003cli\u003eSet of 2 mounting brackets\u003c\/li\u003e\n\u003cli\u003eTerminal connectors\u003c\/li\u003e\n\u003cli\u003eInstallation guide and documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eFAQ\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eWhat systems is this module compatible with?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eA6740-12\u003c\/b\u003e is designed for Emerson EPRO MMS6000 and AMS6500 machinery monitoring systems using the DIN 41494 Eurocard format.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhat are the environmental ratings?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIt operates from \u003cspan style=\"color: #d9534f;\"\u003e0°C to 65°C\u003c\/span\u003e and withstands vibration per IEC 68-2-6 and shock per IEC 68-2-29 standards.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHow many control channels does it provide?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis module provides \u003cspan style=\"color: #d9534f;\"\u003e16 independent relay channels\u003c\/span\u003e for alarm, trip, or control signaling in industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/Protection_Cards_for_AMS_6500_Classic_Systems.pdf?v=1749023994\" target=\"_blank\"\u003eDownload Technical Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51047924367492,"sku":"A6740-12","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/A6740-12.jpg?v=1770125279"},{"product_id":"abb-do802-relay-output-module-3bse022364r1","title":"ABB DO802 Relay Output Module | 3BSE022364R1","description":"\u003ch2\u003eABB DO802 Relay Output Module - Product Overview\u003c\/h2\u003e\n\u003cp\u003eThe ABB \u003cstrong style=\"color: #2e86ab;\"\u003eDO802\u003c\/strong\u003e relay output module provides high-power switching capability for S800 I\/O systems. This 8-channel unit features normally open relay contacts with individual channel isolation for versatile industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e3BSE022364R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABB Model Code:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003eDO802\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Designation:\u003c\/strong\u003e Relay Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Category:\u003c\/strong\u003e Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e Normally Open (NO)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channel Quantity:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e8 independent channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e250 V AC \/ 110 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e 2 A maximum continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 24-110 V DC \/ 250 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Scheme:\u003c\/strong\u003e Individual channel isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e 2000 V AC test voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Management\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus +5V:\u003c\/strong\u003e 70 mA current consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus +24V:\u003c\/strong\u003e 80 mA current requirement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power:\u003c\/strong\u003e Not required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 2.2 W typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Supervision:\u003c\/strong\u003e 24V relay power monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Width:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e86.1 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Depth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e58.5 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Height:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e110 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0.24 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Standard:\u003c\/strong\u003e S800L form factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size Solid:\u003c\/strong\u003e 0.05-2.5 mm² (30-12 AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size Stranded:\u003c\/strong\u003e 0.05-1.5 mm² (30-12 AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 0.5-0.6 Nm recommended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStripping Length:\u003c\/strong\u003e 6-7.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 600 meters maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors:\u003c\/strong\u003e Detachable process connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 according to IEC 60529\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Certificates:\u003c\/strong\u003e ABS, BV, DNV, LR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e DIRECTIVE\/2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat types of loads can DO802 control?\u003c\/h4\u003e\n\u003cp\u003eThe module handles \u003cstrong style=\"color: #2e86ab;\"\u003e250V AC and 110V DC loads\u003c\/strong\u003e up to 2A with NO relay contacts.\u003c\/p\u003e\n\u003ch4\u003eHow are the output channels isolated?\u003c\/h4\u003e\n\u003cp\u003eAll \u003cstrong style=\"color: #2e86ab;\"\u003e8 channels feature individual isolation\u003c\/strong\u003e from each other and from circuit common.\u003c\/p\u003e\n\u003ch4\u003eWhat supervision features are included?\u003c\/h4\u003e\n\u003cp\u003eComprehensive \u003cstrong style=\"color: #2e86ab;\"\u003e24V relay power monitoring\u003c\/strong\u003e with configurable error reporting via ModuleBus.\u003c\/p\u003e\n\u003ch3\u003eContact Information\u003c\/h3\u003e\n\u003cp\u003eFor pricing details and technical assistance:\u003cbr\u003e\u003cstrong\u003eEmail: \u003c\/strong\u003e\u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047928758404,"sku":"DO802","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DO802.jpg?v=1763297005"},{"product_id":"relay-output-module-do828-abb-2a-relay","title":"Relay Output Module DO828 - ABB 2A Relay","description":"\u003ch2\u003eProduct Overview: ABB DO828 Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eDO828\u003c\/strong\u003e delivers advanced relay control capabilities for industrial automation systems. This high-density module features sixteen individually isolated relay outputs perfect for mixed voltage applications. Engineers trust this solution for its robust construction and reliable performance in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eABB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Model: \u003cstrong\u003eDO828\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eArticle Code: 3BSE069055R1\u003c\/li\u003e\n\u003cli\u003eTotal Output Channels: 16 relays\u003c\/li\u003e\n\u003cli\u003eVoltage Capacity: 250V AC \/ 125V DC maximum\u003c\/li\u003e\n\u003cli\u003eCurrent Rating: 2A per channel continuous\u003c\/li\u003e\n\u003cli\u003eContact Type: Normally Open configuration\u003c\/li\u003e\n\u003cli\u003eIsolation Rating: Individual channel-to-channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage Range: 5-250V AC \/ 5-125V DC\u003c\/li\u003e\n\u003cli\u003eDielectric Strength: 2000V AC withstand voltage\u003c\/li\u003e\n\u003cli\u003eModuleBus Consumption: 45mA at +5V DC\u003c\/li\u003e\n\u003cli\u003eRelay Driver Power: 80mA at +24V DC\u003c\/li\u003e\n\u003cli\u003ePower Dissipation: 3.5W typical under normal load\u003c\/li\u003e\n\u003cli\u003eField Wiring Distance: 600 meters maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety \u0026amp; Protection Systems\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e86ab;\"\u003eComplete channel isolation\u003c\/span\u003e prevents cross-talk\u003c\/li\u003e\n\u003cli\u003eEMC protection ensures stable operation\u003c\/li\u003e\n\u003cli\u003eOptical isolation barriers block electrical noise\u003c\/li\u003e\n\u003cli\u003e12V relay power supply monitoring\u003c\/li\u003e\n\u003cli\u003eHazardous location certification: C1 Div 2\u003c\/li\u003e\n\u003cli\u003eInternational safety standards compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to +55°C\u003c\/li\u003e\n\u003cli\u003eStorage Conditions: -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003eHumidity Tolerance: 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003ePollution Degree: Level 2 classification\u003c\/li\u003e\n\u003cli\u003eCorrosion Resistance: ISA-S71.04 G3 rated\u003c\/li\u003e\n\u003cli\u003eMarine Certification: DNV approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 119mm (4.7 inches)\u003c\/li\u003e\n\u003cli\u003eWidth: 45mm (1.77 inches)\u003c\/li\u003e\n\u003cli\u003eDepth: 102mm (4.01 inches)\u003c\/li\u003e\n\u003cli\u003eTotal Weight: 0.18kg (0.4 pounds)\u003c\/li\u003e\n\u003cli\u003eMounting Style: DIN rail standard\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP20 rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSixteen individual channel status LEDs\u003c\/li\u003e\n\u003cli\u003eModule status: Fault, Run, OSP indicators\u003c\/li\u003e\n\u003cli\u003e12V power supply monitoring system\u003c\/li\u003e\n\u003cli\u003eModuleBus communication interface\u003c\/li\u003e\n\u003cli\u003eConfigurable supervision parameters\u003c\/li\u003e\n\u003cli\u003eReal-time error reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with S800 I\/O platform\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003eTU851\u003c\/strong\u003e mounting unit\u003c\/li\u003e\n\u003cli\u003eKeying code: ED for proper installation\u003c\/li\u003e\n\u003cli\u003eModuleBus protocol integration\u003c\/li\u003e\n\u003cli\u003eCompact design saves panel space\u003c\/li\u003e\n\u003cli\u003eEasy maintenance access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackage Includes: \u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eDO828\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003eMounting accessories included\u003c\/li\u003e\n\u003cli\u003eGlobal shipping: FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eProtected industrial packaging\u003c\/li\u003e\n\u003cli\u003eQuick dispatch from warehouse\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat applications suit this module best?\u003c\/strong\u003e\u003cbr\u003ePerfect for controlling motors, valves, and lighting in industrial settings with mixed voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does individual isolation benefit my system?\u003c\/strong\u003e\u003cbr\u003eIt allows different voltage systems on separate channels without interference or safety concerns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat certifications does this module carry?\u003c\/strong\u003e\u003cbr\u003eIt features CE, UL, ATEX Zone 2, and marine certifications for global acceptance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047933509764,"sku":"DO828","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DO828.jpg?v=1763391362"},{"product_id":"bently-nevada-149992-01-relay-module-3500-33","title":"Bently Nevada 149992-01 Relay Module | 3500\/33","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cspan style=\"color:#00529b;font-weight:700;\"\u003eBently Nevada 3500\/33-01-CN 149992-01\u003c\/span\u003e is a 16-channel relay module for 3500 rack systems. It provides alarm and trip outputs for turbines, compressors, and pumps in critical machinery protection applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e – 16-Channel Relay Module.\u003cbr\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e – Standard 16-Channel Relay Output.\u003cbr\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e – Country-specific approvals (China).\u003cbr\u003e\nFour groups of four channels, switch-selectable for Normally De-energized (ND) or Normally Energized (NE) operation.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;\"\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eSPDT, epoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eContact Ratings\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e5A @ 250Vac \/ 5A @ 125Vdc (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMin. Switched Load\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e100mA @ 5Vdc (standard) \/ 1mA @ 1Vdc (gold)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMax Switched Power (DC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMax Switched Power (AC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e1200VA @ 250Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eContact Life\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eArc Suppressor\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e250 Vrms (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eStorage Temp.\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e0.7 kg (1.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eRack Space\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eSet each 4-channel group for ND or NE via onboard switches. Use shielded cables for field wiring. For hazardous areas, observe voltage restrictions (30 Vrms max for CSA-only; lower for multiple approvals). Set initial gap voltage to -10 Vdc for standard 3300 XL probes.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eEpoxy-sealed contacts resist dust and corrosion. The module supports SIL-rated safety functions when used with restricted voltage. Seamless integration with 3500 TSI systems and backward-compatible with older 3300 racks (software v3.3+).\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How to check ND vs NE operation?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Measure coil voltage. ND = de-energized in normal state; NE = energized in normal state. Front-panel CH Alarm LED confirms channel status.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What does -CN approval limit?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e The -CN suffix indicates China-specific approvals. It may impose lower maximum voltage limits than standard. Refer to the certificate for exact ratings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can it replace older 3300\/33 modules?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Yes, with rack configuration v3.3+ and Data Acquisition v2.40+. The module is fully backward-compatible.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050290380932,"sku":"149992-01","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/149992-01.jpg?v=1787408668"},{"product_id":"allen-bradley-1746-ow16-16-channel-relay-contact-output","title":"Allen-Bradley 1746-OW16 | 16 Channel Relay Contact Output","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley SLC 500 Relay Output Module 1746-OW16\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1746-OW16\u003c\/strong\u003e is a 16-point relay output module for the SLC 500 system. It provides flexible switching for both AC and DC loads using reliable Form-A relay contacts, organized into two isolated groups.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Allen-Bradley \u003cstrong\u003e1746-OW16\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SLC 500 I\/O Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e 16-Point Relay Output (Form-A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 16 Normally Open (NO) Relay Contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 5-265V AC, 5-125V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrouping:\u003c\/strong\u003e 2 groups of 8 points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Point (AC):\u003c\/strong\u003e 1.5 A @ 120V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Point (DC):\u003c\/strong\u003e 1.2 A @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Current per Common:\u003c\/strong\u003e 8.0 A AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Current per Module:\u003c\/strong\u003e 16.0 A AC total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Load Current:\u003c\/strong\u003e 10 mA @ 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Leakage:\u003c\/strong\u003e 0 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 60 ms (ON), 2.5 ms (OFF) typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Life:\u003c\/strong\u003e 100,000 cycles at rated load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 0.53 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 independent Form-A (SPST-NO) relay contacts\u003c\/li\u003e\n\u003cli\u003eWide voltage compatibility for AC and DC loads\u003c\/li\u003e\n\u003cli\u003eIsolated commons (2 groups of 8) for wiring flexibility and noise reduction\u003c\/li\u003e\n\u003cli\u003eMechanical relay design provides true galvanic isolation\u003c\/li\u003e\n\u003cli\u003eSuitable for mixed load applications (lamps, solenoids, small motors)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstalls in any slot of an SLC 500 chassis\u003c\/li\u003e\n\u003cli\u003eConnect loads to the relay's common and NO terminal\u003c\/li\u003e\n\u003cli\u003eObserve the 8-point grouping for proper common connection\u003c\/li\u003e\n\u003cli\u003eEnsure load current does not exceed 1.5A AC or 1.2A DC per point\u003c\/li\u003e\n\u003cli\u003eUse external suppression for highly inductive loads to extend relay life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x 1746-OW16 relay output module\u003c\/li\u003e\n\u003cli\u003eApproximate shipping weight: 0.8 kg\u003c\/li\u003e\n\u003cli\u003eSecure protective packaging\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a Form-A relay contact?\u003c\/strong\u003e\u003cbr\u003eA Single-Pole, Single-Throw, Normally Open (SPST-NO) contact. It closes when energized, providing one switching path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I switch an AC load on one channel and a DC load on another?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eYes\u003c\/strong\u003e, because the relays are mechanical and provide full isolation. You can have different voltage types and levels on different channels, as long as each is within its group's common rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is there a minimum load current requirement?\u003c\/strong\u003e\u003cbr\u003eIt ensures reliable contact wetting (cleaning of microscopic oxidation) for low-power signals like PLC inputs or LED indicators, preventing contact failure over time.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050295722116,"sku":"1746-OW16","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1746-OW16_3.jpg?v=1769006263"},{"product_id":"allen-bradley-1783-etap-stratix-100mbps-embedded-switch","title":"Allen-Bradley 1783-ETAP Stratix 100Mbps Embedded Switch","description":"\u003ch2 style=\"color: #2c3e50;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1783-ETAP\u003c\/strong\u003e is an essential EtherNet\/IP Tap designed to provide Device Level Ring (DLR) connectivity for non-DLR enabled devices. This embedded switch module allows single-port devices to connect to a high-availability ring or linear topology, ensuring network resilience and minimizing downtime in mission-critical industrial applications.\u003c\/p\u003e\n\u003cp\u003eEngineered for the factory floor, the 1783-ETAP supports 100 Mbps wire-speed switching and is optimized for a 24V DC (20.4–27.6V) power supply. It features a rugged design with a \u003cstrong\u003eshipping weight of approximately 0.5 kg\u003c\/strong\u003e, capable of sustaining peak performance in high-temperature environments up to 70°C (158°F).\u003c\/p\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eTechnical Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003ePort Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e2 RJ45 Ethernet Ports (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e24V DC Nominal (CL 2 \/ SELV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eWiring Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e22-12 AWG (0.33–3.3 mm²) Copper Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e0.6 to 0.8 N•m (5 to 7 lb•in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eMax Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e70°C (158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eKey Performance Features\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDLR Enabling Technology:\u003c\/strong\u003e Seamlessly integrates single-port industrial devices into a Device Level Ring, providing a self-healing network path for EtherNet\/IP traffic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Connectivity:\u003c\/strong\u003e Equipped with two RJ45 connectors compatible with Category 5e minimum cabling, supporting both linear and ring cable routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Hardened Design:\u003c\/strong\u003e Rated for severe surrounding temperatures (-25°C to +70°C), ensuring reliability in control cabinets near heat-generating machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Compact DIN-rail mountable form factor with simplified 24V DC power terminal blocks for rapid field deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h2\u003e\n\u003cp\u003eThe 1783-ETAP utilizes Category 1 wiring for power ports and Category 2 for communication ports. To ensure electrical safety, use solid or stranded copper wire with a gauge of 22-12 AWG. For optimal network stability, Category 5e (TIA 568-B.1) or higher shielded cabling is recommended to mitigate EMI\/RFI interference common in industrial settings.\u003c\/p\u003e\n\u003ch2 style=\"color: #2c3e50;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main purpose of the 1783-ETAP?\u003c\/strong\u003e\u003cbr\u003eA1: It is primarily used to connect a single-port Ethernet device to a ring topology (DLR) without having to replace the device itself with a multi-port version.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the 1783-ETAP require managed switch configuration?\u003c\/strong\u003e\u003cbr\u003eA2: No, it acts as an unmanaged embedded switch\/tap and is designed for transparent operation within an EtherNet\/IP network, though DLR parameters are managed by the ring supervisor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can it be used in a Star topology?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, while optimized for DLR and linear paths, it can function in a star topology, effectively acting as a small 2-port switch for local device distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e New \u0026amp; Original in Factory Packing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 Months Factory Warranty\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050310172804,"sku":"1783-ETAP","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1783-ETAP-1.jpg?v=1776862374"},{"product_id":"allen-bradley-1783-us4t1f-stratix-2000-5-port-ethernet-switch","title":"Allen-Bradley 1783-US4T1F Stratix 2000 5-Port Ethernet Switch","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2b579a; font-size: 1.1em;\"\u003eAllen-Bradley 1783-US4T1F\u003c\/strong\u003e is a Stratix 2000 unmanaged industrial Ethernet switch designed to provide simple, reliable connectivity for small-scale industrial networks. This 5-port module features \u003cstrong\u003efour 10\/100 Mbps copper RJ45 ports\u003c\/strong\u003e and \u003cstrong\u003eone 100 Mbps multimode fiber optic port\u003c\/strong\u003e. As an unmanaged switch, the 1783-US4T1F offers \"out-of-the-box\" operation with no configuration required. With a compact and lightweight build of \u003cstrong\u003e0.38 kg (0.84 lbs)\u003c\/strong\u003e, it is an ideal choice for connecting PLCs and HMIs in environments where space is at a premium and electrical noise is a factor.\u003c\/p\u003e\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen-Bradley (Rockwell Automation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Model:\u003c\/strong\u003e \u003cspan style=\"color: #2b579a;\"\u003e\u003cstrong\u003e1783-US4T1F\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Stratix 2000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Count:\u003c\/strong\u003e 5 Total Ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Ports:\u003c\/strong\u003e 4 x RJ45 (10\/100 Mbps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Port:\u003c\/strong\u003e 1 x 100FX Multimode Fiber\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e 24V DC (18-60V DC range)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #cccccc; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e-40 °C to +70 °C (-40 °F to 158 °F)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003eOver 1,000,000 Hours\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003eUnmanaged (Plug-and-Play)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003e0.38 kg (0.84 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e35mm DIN Rail\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003eFiber Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e1310 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"key-features-benefits\"\u003eKey Features \u0026amp; Operational Benefits\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Fiber Optic Connectivity:\u003c\/strong\u003e The integrated 100FX multimode fiber port allows the 1783-US4T1F to bridge distances that standard copper cables cannot reach. Fiber is inherently immune to electromagnetic interference (EMI) and radio frequency interference (RFI), ensuring stable data transmission near high-voltage equipment and heavy industrial motors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Ruggedized for Industrial Use:\u003c\/strong\u003e Unlike commercial switches, this Stratix 2000 model is built to survive extreme temperatures from \u003cstrong\u003e-40 °C to +70 °C\u003c\/strong\u003e. Its industrial-grade metal housing provides excellent heat dissipation and mechanical protection against the vibrations common in automotive and material handling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Zero-Configuration Setup:\u003c\/strong\u003e The 1783-US4T1F is a true plug-and-play device. It automatically negotiates speed and duplex settings for each connected device. This eliminates the need for IT intervention and simplifies the replacement process in the field, reducing downtime during maintenance cycles.\u003c\/p\u003e\n\u003ch2 id=\"installation-guide\"\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Snap the switch onto a standard 35mm DIN rail in a horizontal or vertical orientation. Ensure that there is sufficient clearance (at least 50mm) around the unit for air circulation, especially when operating in high-temperature environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowering the Unit:\u003c\/strong\u003e Connect the switch to a stable 24V DC power source using the provided terminal block. The 1783-US4T1F supports a wide input range of 18-60V DC, offering flexibility when integrating into existing control panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiber Connection:\u003c\/strong\u003e When connecting the multimode fiber port, ensure the fiber connectors are clean and properly seated. The 1310 nm wavelength is optimized for long-distance factory floor links without the need for additional signal repeaters.\u003c\/p\u003e\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum distance for the fiber port?\u003c\/strong\u003e\u003cbr\u003eA: The 100FX multimode fiber port typically supports distances up to 2 kilometers (1.2 miles), depending on the quality of the fiber optic cable used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1783-US4T1F be used in a Ring topology?\u003c\/strong\u003e\u003cbr\u003eA: As an unmanaged switch, it does not support Device Level Ring (DLR) or Spanning Tree Protocol (STP). It is designed for linear or star topologies only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the switch compatible with 10 Mbps devices?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the four copper ports feature auto-negotiation and will automatically detect and support both 10 Mbps and 100 Mbps Ethernet devices.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050310271108,"sku":"1783-US4T1F","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1783-US4T1F.jpg?v=1776440055"},{"product_id":"ethernet-switch-1783-us5t-stratix-2000-allen-bradley","title":"Ethernet Switch 1783-US5T Stratix 2000 Allen-Bradley","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86c1; font-size: 1.1em;\"\u003eAllen-Bradley 1783-US5T\u003c\/strong\u003e is a compact and efficient Stratix 2000™ unmanaged Ethernet switch designed for simplified networking in industrial automation. Featuring \u003cstrong\u003efive (5) Fast Ethernet RJ45 ports\u003c\/strong\u003e, this switch provides a cost-effective way to expand copper-based network connectivity for PLCs, HMIs, and small I\/O banks. Its rugged design and \"plug-and-play\" functionality make it an essential component for machine builders and facility engineers looking for reliable communication without the need for complex software management.\u003c\/p\u003e\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Rockwell Automation \/ Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e Stratix 2000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003e\u003cstrong\u003e1783-US5T\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Ports:\u003c\/strong\u003e 5 RJ45 Copper Ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Speed:\u003c\/strong\u003e 10 \/ 100 Mbps (Autosensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirement:\u003c\/strong\u003e 24V AC\/DC Nominal (12-48V DC, 18-30V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard 35mm DIN Rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #cccccc; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003e300 g (0.66 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e-10°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e3.4 Watts\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e1.85 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eNetwork Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e512 kb Packet Buffer Size; MTBF: 1,000,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"installation-guide\"\u003eInstallation \u0026amp; Application\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Simplified Setup:\u003c\/strong\u003e The 1783-US5T requires no software configuration. Once mounted on a DIN rail and supplied with power, it automatically negotiates the fastest possible speed (up to 100 Mbps) and duplex mode for each connected device. The 512 kb packet buffer ensures efficient data handling even during high-traffic intervals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Robust Powering:\u003c\/strong\u003e This switch is versatile enough to operate on both AC and DC power supplies (Nominal 24V). Its low power consumption of 3.4W reduces the thermal load within control cabinets, while its 15 g operating shock rating ensures stability in environments with moving machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Compact Footprint:\u003c\/strong\u003e With its lightweight 300g housing, the 1783-US5T is designed for space-constrained enclosures. It provides a highly reliable mean time between failures (MTBF) of 1,000,000 hours, ensuring long-term service life in typical industrial temperature ranges of -10°C to +60°C.\u003c\/p\u003e\n\u003ch2 id=\"engineering-advantages\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley 1783-US5T offers industrial-grade durability compared to standard commercial switches. By meeting UL\/cUL safety ratings and featuring broadcast storm protection, it prevents network crashes that could otherwise disrupt manufacturing processes. Its unmanaged nature means it is immune to configuration errors and cybersecurity vulnerabilities associated with managed IP interfaces, providing a secure and straightforward hardware-based switching solution.\u003c\/p\u003e\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this switch for EtherNet\/IP communication?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, the 1783-US5T is fully compatible with EtherNet\/IP, though as an unmanaged switch, it does not support IGMP snooping for specialized multicast traffic management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the module support Power over Ethernet (PoE)?\u003c\/strong\u003e\u003cbr\u003eA2: No, the 1783-US5T is a standard data switch. It does not provide power to connected field devices via the RJ45 ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is there a specific mounting orientation required?\u003c\/strong\u003e\u003cbr\u003eA3: The switch is designed for vertical DIN rail mounting to allow for optimal convective cooling across the internal components.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050310336644,"sku":"1783-US5T","price":193.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1783-US5T-1.jpg?v=1776179678"},{"product_id":"1783-us6t2f-allen-bradley-6-rj45-2-multimode-fiber-switch","title":"1783-US6T2F Allen-Bradley 6 RJ45 2 Multimode Fiber Switch","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86c1; font-size: 1.1em;\"\u003eAllen-Bradley 1783-US6T2F\u003c\/strong\u003e is a versatile Stratix 2000™ unmanaged Ethernet switch designed for rugged industrial applications requiring both copper and fiber optic connectivity. This 8-port unit features \u003cstrong\u003esix (6) Fast Ethernet RJ45 ports\u003c\/strong\u003e and \u003cstrong\u003etwo (2) multimode fiber SFP slots\u003c\/strong\u003e, providing high-speed data transmission and long-distance uplink capabilities. Its \"plug-and-play\" design allows for immediate network expansion without complex software configuration, making it an ideal choice for connecting remote I\/O and field devices in harsh environments.\u003c\/p\u003e\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen-Bradley \/ Rockwell Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e Stratix 2000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003e\u003cstrong\u003e1783-US6T2F\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Ports:\u003c\/strong\u003e 8 (6 RJ45 Copper, 2 Multimode Fiber SFP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e 10\/100 Mbps Fast Ethernet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 24V Nominal (18-60V DC \/ 18-30V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Class 2\/SELV Power Supply Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #cccccc; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003e0.7 kg (1.54 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e-40°C to 75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e5.927 W (Maximum)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e442.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eFiber Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e2 Multimode Fiber SFP Slots (Fiber Port 2 multimode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"installation-guide\"\u003eInstallation \u0026amp; Fiber Integration\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Hybrid Connectivity:\u003c\/strong\u003e The 1783-US6T2F bridges the gap between local copper-based devices and remote fiber-optic segments. The two multimode fiber ports allow for secure, interference-free communication over longer distances than standard copper cabling, which is essential for large-scale industrial sites or high-EMI environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Extreme Environment Reliability:\u003c\/strong\u003e Engineered for durability, this switch features an expanded operating temperature range of -40°C to 75°C. This allows for installation in outdoor enclosures or unconditioned factory floors where standard commercial switches would fail. The compact 0.7 kg housing is designed for efficient heat dissipation without the need for internal fans.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Power Versatility:\u003c\/strong\u003e The module supports a wide input voltage range (18-60V DC or 18-30V AC), accommodating various industrial power standards. To maintain safety compliance, ensure the unit is connected to a Class 2 or SELV power source, providing stable current at approximately 442.3 mA.\u003c\/p\u003e\n\u003ch2 id=\"engineering-advantages\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley 1783-US6T2F offers a robust \"set and forget\" solution for network engineers. By providing unmanaged operation, it eliminates the risk of misconfiguration in simple network segments. Its high power dissipation efficiency (less than 6W) minimizes the thermal load within control cabinets, while the inclusion of SFP slots provides the flexibility to swap fiber transceivers based on specific multimode distance requirements.\u003c\/p\u003e\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Are the SFP transceivers included with the 1783-US6T2F?\u003c\/strong\u003e\u003cbr\u003eA1: Typically, SFP transceivers are sold separately to allow engineers to choose the specific multimode or single-mode distance rating required for their application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this switch in a ring topology?\u003c\/strong\u003e\u003cbr\u003eA2: As an unmanaged switch, it does not support Spanning Tree Protocol (STP) or Device Level Ring (DLR). It is best used in star or linear topologies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module require DIN rail grounding?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, for optimal EMC performance and protection against transients, the unit should be securely mounted to a grounded 35mm DIN rail.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050310369412,"sku":"1783-US6T2F","price":194.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1783-US6T2F-1.jpg?v=1776178992"},{"product_id":"allen-bradley-1783-us8t-stratix-2000-unmanaged-switch","title":"Allen-Bradley 1783-US8T Stratix 2000 Unmanaged Switch","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86c1; font-size: 1.1em;\"\u003eAllen-Bradley 1783-US8T\u003c\/strong\u003e is a reliable Stratix 2000™ unmanaged Ethernet switch designed for simple, plug-and-play connectivity in industrial automation environments. Featuring \u003cstrong\u003eeight (8) RJ45 Fast Ethernet ports\u003c\/strong\u003e, this switch provides an easy way to expand your network without the need for complex configuration. Its compact, open-style design is optimized for DIN rail mounting within control panels, offering a cost-effective solution for connecting controllers, HMIs, and other Ethernet-enabled field devices.\u003c\/p\u003e\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Rockwell Automation \/ Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Series:\u003c\/strong\u003e Stratix 2000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003e\u003cstrong\u003e1783-US8T\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Count:\u003c\/strong\u003e 8 RJ45 Copper Ports (10\/100 Mbps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 24V Nominal (Supports 12-48V DC or 18-30V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Type:\u003c\/strong\u003e Unmanaged (Plug-and-Play)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN Rail Mount (Open-style rating)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #cccccc; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003e0.38 kg (0.84 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e0 to 60°C (32 to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e114.5 x 45.6 x 76.8 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e1.31 A (Maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e4.6 W; Wiring Category 1 (Power) \u0026amp; Category 2 (Communication)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"installation-guide\"\u003eInstallation \u0026amp; Powering Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Versatile Power Options:\u003c\/strong\u003e The 1783-US8T is highly flexible regarding power sources. It accepts a wide range of DC voltages (12-48V) and can also be powered by 24V AC, making it compatible with various machine power distribution standards. To ensure safety, the power input must be supplied by a \u003cstrong\u003eSELV (Safety Extra Low Voltage)\u003c\/strong\u003e source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Grounding Requirements:\u003c\/strong\u003e For reliable operation and noise immunity, the switch requires a functional earth connection. It is recommended to use 2.5 mm² (14 AWG) copper wire with a suitable ring terminal for the grounding lug, ensuring the wire is rated for at least 30°C above the surrounding ambient temperature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Space-Saving Design:\u003c\/strong\u003e With a narrow width of approximately 45.6 mm, the 1783-US8T is designed to fit into crowded control cabinets. The \"open-style\" rating means the switch should be installed in an appropriate industrial enclosure (such as a NEMA or IP rated cabinet) to protect the internal components from environmental contaminants.\u003c\/p\u003e\n\u003ch2 id=\"engineering-advantages\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe Stratix 2000 series removes the technical barrier to industrial networking. The 1783-US8T automatically negotiates speed and duplex settings for each connected device, eliminating the need for IT intervention or software management. With a maximum power consumption of only 4.6W and robust vibration\/shock resistance, this switch is engineered for long-term stability in factory floor environments where reliability is paramount for non-stop production cycles.\u003c\/p\u003e\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does this switch support Gigabit speeds?\u003c\/strong\u003e\u003cbr\u003eA1: No, the 1783-US8T features Fast Ethernet ports with speeds up to 100 Mbps, which is sufficient for the majority of industrial I\/O and PLC communication tasks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use fiber optic connections with this model?\u003c\/strong\u003e\u003cbr\u003eA2: This specific model (1783-US8T) features 8 RJ45 copper ports only. For fiber optic capability, you would need a Stratix 2000 model that includes SFP ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is any configuration software required for startup?\u003c\/strong\u003e\u003cbr\u003eA3: No. As an unmanaged switch, the 1783-US8T works immediately upon power-up and connection to the network.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050310434948,"sku":"1783-US8T","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1783-US8T-1.jpg?v=1776178396"},{"product_id":"allen-bradley-1794-ow8-flex-io-8-channel-relay-output-module-24v","title":"Allen-Bradley 1794-OW8 Flex IO 8-Channel Relay Output Module 24V","description":"\u003ch2\u003eFlex IO Relay Output Module for Industrial Control\u003c\/h2\u003e\n\u003cp\u003eAllen-Bradley \u003cstrong\u003e1794-OW8\u003c\/strong\u003e delivers eight relay outputs for Flex IO systems. This module switches 250V AC loads at 2A per channel. It works with 1794-TB2, 1794-TB3, or 1794-TB3S terminal bases.\u003c\/p\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eBrand:\u003c\/strong\u003e Allen-Bradley.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e1794-OW8\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eProduct Type:\u003c\/strong\u003e Flex IO Relay Output Module.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eSupply Voltage:\u003c\/strong\u003e 24V DC.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eRelay Contact Rating:\u003c\/strong\u003e 250V AC, 2A.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003ePilot Duty Rating:\u003c\/strong\u003e R150.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eKeyswitch Position:\u003c\/strong\u003e 9.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePerformance \u0026amp; Life Ratings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRelay Life Expectancy:\u003c\/strong\u003e 10 million cycles.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMinimum Contact Load:\u003c\/strong\u003e 100 μA at 100 mV DC.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFlexBus Current:\u003c\/strong\u003e 60 mA maximum.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 5.5 W.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e 18.8 BTU\/hr.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 2500V DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e 0°C to 55°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStorage Temp:\u003c\/strong\u003e -40°C to 85°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% non-condensing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 5g at 10-500 Hz.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating Shock:\u003c\/strong\u003e 30g.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eWeight:\u003c\/strong\u003e 0.24 kg (0.53 lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Terminal Bases\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e1794-TB2.\u003c\/li\u003e\n    \u003cli\u003e1794-TB3.\u003c\/li\u003e\n    \u003cli\u003e1794-TB3S.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage \u0026amp; Shipping\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e One Allen-Bradley \u003cstrong\u003e1794-OW8\u003c\/strong\u003e module.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDelivery:\u003c\/strong\u003e FedEx, UPS, or DHL.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e In stock.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePayment:\u003c\/strong\u003e T\/T, Western Union.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What terminal bases work with this module?\u003c\/strong\u003e\n        \u003cbr\u003eA: Use 1794-TB2, 1794-TB3, or 1794-TB3S. Choose based on your wiring density and removable terminal block needs.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum reliable contact load?\u003c\/strong\u003e\n        \u003cbr\u003eA: 100 μA at 100 mV DC. Use dry contact switching for very low current signals to prevent oxidation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: How many cycles can the relays handle?\u003c\/strong\u003e\n        \u003cbr\u003eA: 10 million cycles under rated load. Derate cycle life for higher switching frequencies or inductive loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050311712900,"sku":"1794-OW8","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1794-OW8.jpg?v=1780063439"},{"product_id":"bently-nevada-3500-33-01-00-16-channel-relay-module","title":"Bently Nevada 3500\/33-01-00 16-Channel Relay Module","description":"\u003ch2\u003eBently Nevada 3500\/33-01-00 16-Channel Relay Module\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5276;\"\u003eBently Nevada 3500\/33-01-00\u003c\/strong\u003e is a 16-Channel Relay Module for 3500 rack systems. Each channel features a single-pole double-throw (SPDT) relay with epoxy sealing and built-in arc suppression for reliable alarm output in machinery protection applications.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e 3500\/33-01-00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 16-Channel Relay Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eModel Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e – 16-Channel Relay Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e – No Agency Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 60%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMain Module (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e241 × 24.4 × 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eI\/O Module (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e241 × 24.4 × 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eSPDT (Single-Pole Double-Throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Sealing\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eArc Suppressor\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e250 Vrms standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eContact Life\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Groups\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e4 groups of 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Operation\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eSwitch selectable ND or NE per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMain Module Rack Space\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eI\/O Module Rack Space\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eContact Ratings\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 30%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 35%;\"\u003eStandard Relays\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 35%;\"\u003eLow Current Relays\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Current (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5 A\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e100 mA @ 48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Voltage (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e125 Vdc\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Current (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5 A\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Voltage (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e250 Vac\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e120 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Power (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e70 W @ 24 Vdc\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Power (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1200 VA\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFront Panel LEDs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOK LED:\u003c\/strong\u003e Illuminated when module is operating properly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTX\/RX LED:\u003c\/strong\u003e Flashes during communication with other rack modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH Alarm LED:\u003c\/strong\u003e Illuminated when relay channel is in alarm state\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFCC Part 15\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-2 \/ -6-4 (EMC)\u003c\/li\u003e\n\u003cli\u003eEN 61010-1 (Electrical Safety)\u003c\/li\u003e\n\u003cli\u003eRoHS 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eDNV GL, ABS (Maritime)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation and Safety\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWARNING: HAZARDOUS VOLTAGE\u003c\/strong\u003e\u003cbr\u003e\nRisk of electric shock or burn. When connecting field wiring, conductors may be exposed, creating a shock hazard at high voltages.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWARNING: EXPLOSION HAZARD\u003c\/strong\u003e\u003cbr\u003e\nDisconnect power prior to servicing. Do not disconnect while circuit is live unless area is known to be non-hazardous. Consult manual prior to servicing.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How are the 16 relays organized?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Four groups of four channels. Each group is switch selectable for Normally De-energized (ND) or Normally Energized (NE) operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the difference between standard and low current relays?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Standard relays (silver contacts) require 100 mA @ 5 Vdc minimum. Low current relays (gold-plated) switch 1 mA @ 1 Vdc minimum for sensitive circuits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the relay contact life?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e 10,000 cycles at rated load. Arc suppressor is installed as standard to extend contact life.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050454220932,"sku":"3500\/33-01-00","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33-01-00.jpg?v=1784469438"},{"product_id":"do821-abb-relay-output-module-8-channel-230v","title":"DO821 ABB - Relay Output Module | 8-Channel 230V","description":"\u003ch2\u003eABB DO821 Relay Output Module for S800 I\/O Systems\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eDO821\u003c\/strong\u003e provides reliable relay output control for industrial automation applications. This 8-channel module handles high voltage loads up to 250V AC\/DC with robust 3A contacts. It offers individual channel isolation and comprehensive diagnostic capabilities.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDO821\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput Channels: 8 relay channels\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 5-250V AC\/DC range\u003c\/li\u003e\n\u003cli\u003eCurrent Capacity: 3A per channel continuous\u003c\/li\u003e\n\u003cli\u003eContact Type: Normally Closed (NC) configuration\u003c\/li\u003e\n\u003cli\u003eIsolation: Individual channel-to-channel isolation\u003c\/li\u003e\n\u003cli\u003ePower Dissipation: 2.9W typical operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Type: Relay contacts with NC operation\u003c\/li\u003e\n\u003cli\u003eMaximum Voltage: 250V AC\/DC working voltage\u003c\/li\u003e\n\u003cli\u003eDielectric Strength: 2000V AC test voltage\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 60mA at +5V ModuleBus\u003c\/li\u003e\n\u003cli\u003eRelay Power: 140mA at +24V ModuleBus\u003c\/li\u003e\n\u003cli\u003eCable Length: 600 meters maximum field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection and Safety Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e86ab;\"\u003eIndividual channel isolation\u003c\/span\u003e for safety\u003c\/li\u003e\n\u003cli\u003eEMC protection components on all outputs\u003c\/li\u003e\n\u003cli\u003eOptical isolation barriers for noise immunity\u003c\/li\u003e\n\u003cli\u003eRelay power supply voltage monitoring\u003c\/li\u003e\n\u003cli\u003eOvervoltage Category: III according to standards\u003c\/li\u003e\n\u003cli\u003eIP20 protection against dust and contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to +55°C range\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40°C to +70°C limits\u003c\/li\u003e\n\u003cli\u003eHumidity Range: 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003ePollution Degree: Level 2 classification\u003c\/li\u003e\n\u003cli\u003eCorrosion Protection: ISA-S71.04 G3 rating\u003c\/li\u003e\n\u003cli\u003eVibration Compliance: IEC 61131-2 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics and Monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 individual channel status LEDs\u003c\/li\u003e\n\u003cli\u003eModule indicators: Fault, Run, Warning, OSP\u003c\/li\u003e\n\u003cli\u003eRelay supply voltage supervision\u003c\/li\u003e\n\u003cli\u003eModuleBus communication for diagnostics\u003c\/li\u003e\n\u003cli\u003eConfigurable error detection parameters\u003c\/li\u003e\n\u003cli\u003eReal-time status monitoring capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with S800 I\/O mounting units\u003c\/li\u003e\n\u003cli\u003eWorks with \u003cstrong\u003eTU811\u003c\/strong\u003e, \u003cstrong\u003eTU813\u003c\/strong\u003e, \u003cstrong\u003eTU831\u003c\/strong\u003e MTUs\u003c\/li\u003e\n\u003cli\u003eKeying code CA for proper installation\u003c\/li\u003e\n\u003cli\u003eCompact dimensions: 45mm W × 119mm H × 102mm D\u003c\/li\u003e\n\u003cli\u003eWeight: 0.23 kg for easy handling\u003c\/li\u003e\n\u003cli\u003eStandard rail mounting design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging and Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes one \u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eDO821\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003eAll necessary installation components\u003c\/li\u003e\n\u003cli\u003eFast worldwide shipping via FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eSecure industrial packaging protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does Normally Closed (NC) mean?\u003c\/strong\u003e\u003cbr\u003eNC contacts are closed when the relay is not energized and open when activated for fail-safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is channel isolation beneficial?\u003c\/strong\u003e\u003cbr\u003eIndividual isolation prevents cross-channel interference and allows mixed voltage applications on different channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat monitoring capabilities are available?\u003c\/strong\u003e\u003cbr\u003eThe module provides relay power monitoring and status indicators with ModuleBus communication for system integration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050469720196,"sku":"DO821","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DO821.jpg?v=1763390784"},{"product_id":"3bse022364r1-8-channel-relay-output-abb","title":"3BSE022364R1 8-Channel Relay Output ABB","description":"\u003ch2\u003eABB 3BSE022364R1 Relay Output Module - Technical Specifications\u003c\/h2\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Code:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e3BSE022364R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Designation:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003eDO802\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e S800 I\/O System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Category:\u003c\/strong\u003e Digital Output Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Quantity:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e8 output channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Mechanism:\u003c\/strong\u003e Relay with Normally Open contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Scheme:\u003c\/strong\u003e Individual channel separation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Arrangement:\u003c\/strong\u003e Normally Open configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Classification:\u003c\/strong\u003e Digital Output type\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Capacity:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e24-110V DC \/ 250V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Handling:\u003c\/strong\u003e 2 Amperes maximum per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Method:\u003c\/strong\u003e Optical separation per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e No HART capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental and Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e No intrinsic safety rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20°C to +60°C ambient\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e Standard industrial environment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Limits:\u003c\/strong\u003e Standard temperature operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Configuration:\u003c\/strong\u003e Normally Open contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Performance:\u003c\/strong\u003e Individual channel isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e 2A per channel maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Compatibility:\u003c\/strong\u003e Mixed AC\/DC operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat voltage levels can this module control?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eDO802\u003c\/strong\u003e handles \u003cstrong style=\"color: #2e86ab;\"\u003e24-110V DC and 250V AC\u003c\/strong\u003e loads with 2A capacity.\u003c\/p\u003e\n\u003ch4\u003eHow many relay outputs are provided?\u003c\/h4\u003e\n\u003cp\u003eThis unit features \u003cstrong style=\"color: #2e86ab;\"\u003e8 individually isolated relay channels\u003c\/strong\u003e with NO contacts.\u003c\/p\u003e\n\u003ch4\u003eWhat is the operating temperature range?\u003c\/h4\u003e\n\u003cp\u003eDesigned for \u003cstrong style=\"color: #2e86ab;\"\u003e-20°C to +60°C ambient temperatures\u003c\/strong\u003e in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eContact Information\u003c\/h3\u003e\n\u003cp\u003eFor pricing details and technical assistance:\u003cbr\u003e\u003cstrong\u003eEmail: \u003c\/strong\u003e\u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050492067972,"sku":"3BSE022364R1","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3BSE022364R1.jpg?v=1763297250"},{"product_id":"abb-3bse069055r1-relay-output-module-2a-16-channel","title":"ABB 3BSE069055R1 Relay Output Module | 2A 16-Channel","description":"\u003ch2\u003eABB 3BSE069055R1 Digital Output Module Technical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eDO828\u003c\/strong\u003e provides reliable relay output control for industrial automation systems. This 16-channel module handles both AC and DC loads with individual channel isolation. It offers robust performance and comprehensive diagnostics for demanding applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eABB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eDO828\u003c\/strong\u003e Digital Output Module\u003c\/li\u003e\n\u003cli\u003ePart Number: 3BSE069055R1\u003c\/li\u003e\n\u003cli\u003eModule Type: Relay Output for S800 I\/O Systems\u003c\/li\u003e\n\u003cli\u003eCertifications: CE, UL, ATEX Zone 2, DNV Marine\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Channels: 16 individually isolated relays\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 250V AC \/ 125V DC maximum\u003c\/li\u003e\n\u003cli\u003eCurrent Capacity: 2A per channel continuous\u003c\/li\u003e\n\u003cli\u003eContact Type: SPDT (Single Pole Double Throw)\u003c\/li\u003e\n\u003cli\u003eOperating Range: 5-250V AC \/ 5-125V DC\u003c\/li\u003e\n\u003cli\u003eDielectric Strength: 2000V AC test voltage\u003c\/li\u003e\n\u003cli\u003ePower Dissipation: 3.5W typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to +55°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003eHumidity Range: 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003eVibration Resistance: IEC 60068-2-6 compliant\u003c\/li\u003e\n\u003cli\u003eShock Resistance: IEC 60068-2-27 compliant\u003c\/li\u003e\n\u003cli\u003ePollution Degree: Level 2 classification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 119mm H × 45mm W × 102mm D\u003c\/li\u003e\n\u003cli\u003eWeight: 0.18 kg (0.4 lbs)\u003c\/li\u003e\n\u003cli\u003eMounting: Standard DIN rail installation\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP20 according to IEC 60529\u003c\/li\u003e\n\u003cli\u003eField Wiring: 600 meters maximum cable length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with S800 I\/O systems\u003c\/li\u003e\n\u003cli\u003eDesigned for use with \u003cstrong\u003eTU851\u003c\/strong\u003e mounting unit\u003c\/li\u003e\n\u003cli\u003eKeying code: ED for proper installation\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting for easy installation\u003c\/li\u003e\n\u003cli\u003eMaximum ambient temperature: 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does SPDT relay contact mean?\u003c\/strong\u003e\u003cbr\u003eSPDT (Single Pole Double Throw) contacts can switch one common connection between two different circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does voltage supervision work?\u003c\/strong\u003e\u003cbr\u003eThe module monitors relay supply voltage and activates warning indicators if voltage drops below safe levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use different voltages on each channel?\u003c\/strong\u003e\u003cbr\u003eYes, individual channel isolation allows different voltages on each channel up to the maximum ratings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050503798916,"sku":"3BSE069055R1","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3BSE069055R1.jpg?v=1763391727"},{"product_id":"1756-ox8i-allen-bradley-controllogix-relay-output","title":"1756-OX8I Allen-Bradley ControlLogix Relay Output","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-OX8I\u003c\/strong\u003e is a relay output module for ControlLogix systems. It features 8 individually isolated Form C relays. \u003c\/p\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #333333;\"\u003eBrand:\u003c\/span\u003e \u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e (Rockwell Automation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #333333;\"\u003eSeries:\u003c\/span\u003e ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #333333;\"\u003eModel:\u003c\/span\u003e \u003cstrong\u003e1756-OX8I\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #333333;\"\u003eRelay Configuration:\u003c\/span\u003e 8 individually isolated relay outputs with Form C contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #333333;\"\u003eTerminal Blocks:\u003c\/span\u003e Compatible with 1756-TBCH and 1756-TBS6H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOutput Current Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 A at 30V DC\u003c\/li\u003e\n\u003cli\u003e0.5 A at 150V DC\u003c\/li\u003e\n\u003cli\u003e0.25 A at 240V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVoltage Range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOperates at 10-265V AC\u003c\/li\u003e\n\u003cli\u003eOperates at 5-150V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the current ratings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 2A at 30V DC, 0.5A at 150V DC, and 0.25A at 240V AC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the voltage range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 10-265V AC and 5-150V DC for flexible load compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the backplane current draw?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 100 mA at 5V. Maximum power dissipation is 3.1W at 60°C.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050726948996,"sku":"1756-OX8I","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1756-OX8I-1.jpg?v=1774268203"},{"product_id":"1769-ow8i-allen-bradley-compactlogix-8-pt-isolated-relay-output","title":"1769-OW8I Allen-Bradley | CompactLogix 8-Pt Isolated Relay Output","description":"\u003ch2\u003e1769-OW8I Allen-Bradley: CompactLogix Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1769-OW8I\u003c\/strong\u003e is an 8-channel discrete output module for CompactLogix systems. This module features \u003cspan style=\"color: #005a9c;\"\u003eeight individually isolated relay outputs\u003c\/span\u003e for flexible field device control. Engineers choose the \u003cstrong\u003e1769-OW8I\u003c\/strong\u003e for applications requiring isolated switching of AC or DC loads.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eManufacturer:\u003c\/span\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003ePart Number:\u003c\/span\u003e 1769-OW8I\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eUPC:\u003c\/span\u003e 662468992916\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eProduct Type:\u003c\/span\u003e Discrete Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eProduct Line:\u003c\/span\u003e CompactLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eProduct Family:\u003c\/span\u003e Compact I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eModule Type:\u003c\/span\u003e Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eNo. of Outputs:\u003c\/span\u003e 8 individually isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOutput Type:\u003c\/span\u003e Relay Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eI\/O Type:\u003c\/span\u003e Contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003ePower Supply Distance Rating:\u003c\/span\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWeight:\u003c\/span\u003e 0.23 kg (0.50 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEight individually isolated relay outputs\u003c\/li\u003e\n\u003cli\u003eEach channel isolated for independent switching\u003c\/li\u003e\n\u003cli\u003eCompatible with AC and DC load types\u003c\/li\u003e\n\u003cli\u003eCompact design for high-density installations\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x Allen-Bradley \u003cstrong\u003e1769-OW8I\u003c\/strong\u003e output module\u003c\/li\u003e\n\u003cli\u003eFactory sealed anti-static packaging\u003c\/li\u003e\n\u003cli\u003eOriginal Allen-Bradley box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx, UPS, DHL Express worldwide\u003c\/li\u003e\n\u003cli\u003eSame-day dispatch, tracking provided\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Weight of 1769-OW8I?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 0.23 kg (0.50 lbs).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many outputs does this module have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Eight individually isolated relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the power supply distance rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Rating 8 for CompactLogix power supply positioning.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050727014532,"sku":"1769-OW8I","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1769-OW8I.jpg?v=1777036661"},{"product_id":"allen-bradley-1794-oa16-16-point-ac-load-switching-module","title":"Allen-Bradley 1794-OA16 | 16-Point AC Load Switching Module","description":"\u003ch2\u003e\u003cstrong\u003e16-Channel AC Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1976d2;\"\u003eAllen-Bradley 1794-OA16\u003c\/strong\u003e controls AC loads directly. This Flex I\/O module offers 16 non-isolated outputs with 0.12kg weight.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eAllen-Bradley 1794-OA16\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Flex I\/O AC Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 16 non-isolated channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 VAC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 74-120 VAC ON state\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 4.0 Amps per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot Duty:\u003c\/strong\u003e 5A inrush capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 120 V continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 94 x 94 x 69 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.12 kg module weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open-type design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN Rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 55°C (32°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC solenoid valve control\u003c\/li\u003e\n\u003cli\u003eMotor starter control circuits\u003c\/li\u003e\n\u003cli\u003eAC indicator light arrays\u003c\/li\u003e\n\u003cli\u003eHeating element control\u003c\/li\u003e\n\u003cli\u003eIndustrial AC relay banks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e16-channel AC output capacity\u003c\/li\u003e\n\u003cli\u003eDirect 120VAC load control\u003c\/li\u003e\n\u003cli\u003e4A total current rating\u003c\/li\u003e\n\u003cli\u003e5A inrush current handling\u003c\/li\u003e\n\u003cli\u003eLightweight 0.12kg design\u003c\/li\u003e\n\u003cli\u003eDIN Rail mounting for easy installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow many AC outputs does it have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e16 non-isolated AC output channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the voltage rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e120 VAC nominal with 74-120 VAC operating range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the module weight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e0.12 kg lightweight for easy handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050728849540,"sku":"1794-OA16","price":231.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1794-OA16-1.jpg?v=1769605662"},{"product_id":"ge-fanuc-ic694mdr390-2a-relay-output-module","title":"GE Fanuc IC694MDR390 2A Relay Output Module","description":"\u003ch2\u003eGE Fanuc IC694MDR390 Input Output Module for RX3i PacSystem PLCs\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDR390\u003c\/strong\u003e is a mixed input\/output module for the RX3i PacSystem series. It combines 8 discrete inputs with 8 relay outputs in a single module, providing flexible I\/O expansion for industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eInput Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e8 individually isolated sinking\/sourcing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 5 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Current:\u003c\/strong\u003e 7.5 mA per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Response Time:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e7.5 milliseconds On\/Off\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Between Inputs:\u003c\/strong\u003e 500 VAC RMS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutput Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e2 groups of 4 Normally Open relay outputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 5 to 30 VDC or 5 to 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Current per Output:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e2.0 Amps Max\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Response Time:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e15 milliseconds On\/Off\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Capacity:\u003c\/strong\u003e 5.0 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Output Load:\u003c\/strong\u003e 10 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Between Outputs:\u003c\/strong\u003e 500 VAC RMS per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Operating Frequency:\u003c\/strong\u003e 50 to 60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731274372,"sku":"IC694MDR390","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDR390.jpg?v=1774340848"},{"product_id":"bently-nevada-3500-33-16-channel-relay-module","title":"Bently Nevada 3500\/33 16-Channel Relay Module","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3500\/33: 16-Channel Relay Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2a71d0;\"\u003eBently Nevada 3500\/33\u003c\/strong\u003e provides reliable relay outputs for monitoring systems. This 16-channel module connects to the 3500 monitoring platform. It delivers critical alarm and shutdown signals. The module supports various industrial protection applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e3500\/33\u003c\/strong\u003e 16-Channel Relay Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 independent relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 5.8 watts typical consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Type:\u003c\/strong\u003e SPDT (Single-pole Double-throw)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Life:\u003c\/strong\u003e 10,000 operation cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.7 kg (Main), 0.4 kg (I\/O)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eConfiguration Options\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a71d0;\"\u003e01:\u003c\/strong\u003e Standard 16-channel relay output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a71d0;\"\u003e02:\u003c\/strong\u003e Failsafe 16-channel relay output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a71d0;\"\u003e03:\u003c\/strong\u003e Low current 16-channel relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a71d0;\"\u003e04:\u003c\/strong\u003e Low current failsafe relay\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Module:\u003c\/strong\u003e 241 x 24.4 x 242 mm, 0.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Module:\u003c\/strong\u003e 241 x 24.4 x 99.1 mm, 0.4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Space:\u003c\/strong\u003e One full-height front and rear slot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #d02a2a;\"\u003eOK LED:\u003c\/strong\u003e Green - module functioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTX\/RX LED:\u003c\/strong\u003e Flashes - active communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #d02a2a;\"\u003eCH Alarm:\u003c\/strong\u003e Red - relay channel alarm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eRelay Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #d02a2a;\"\u003eSealing:\u003c\/strong\u003e Epoxy-sealed construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc Suppressor:\u003c\/strong\u003e 250 Vrms standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModes:\u003c\/strong\u003e Configurable in 4 groups (ND\/NE)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eHazardous Area Options\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e No special approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #d02a2a;\"\u003e01:\u003c\/strong\u003e cNRTLus (Class 1, Div 2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02:\u003c\/strong\u003e ATEX\/IECEx\/CSA (Zone 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMain module (0.7 kg) and I\/O module (0.4 kg)\u003c\/li\u003e\n\u003cli\u003eMounting hardware included\u003c\/li\u003e\n\u003cli\u003eFedEx, UPS, DHL shipping available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in 3500 series rack\u003c\/li\u003e\n\u003cli\u003eRequires one full-height slot\u003c\/li\u003e\n\u003cli\u003eEnsure proper ventilation\u003c\/li\u003e\n\u003cli\u003eFollow wiring guidelines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat systems use this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003e3500\/33\u003c\/strong\u003e works with Bently Nevada 3500 monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow many relay channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 independent SPDT relay channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eND vs NE configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eND contacts open at rest, NE contacts closed at rest.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eContent by Etowon Auto.\u003c\/em\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050779574404,"sku":"3500\/33","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33.jpg?v=1769832846"},{"product_id":"honeywell-cc-tdor01-51308376-175-16-channel-relay-module","title":"Honeywell CC-TDOR01 51308376-175 16-Channel Relay Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #007bff;\"\u003eHoneywell CC-TDOR01 51308376-175\u003c\/strong\u003e serves as a high-density 16-channel Digital Output Relay Module structured for the Series C Digital Output Field Termination Assembly (IOTA) architecture. This critical control component drives interposing relays, solenoids, motor starters, and indicators across automated networks. It delivers deterministic switching and galvanic line isolation between automated controller logic and high-energy field loads.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technological Advantages\u003c\/h2\u003e\n\u003ch3\u003eVersatile Dual-State Relay Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module board integrates 16 isolated digital outputs configurable for both Normally Open (NO) and Normally Closed (NC) dry contact setups, allowing physical integration into diverse fail-safe logic designs without external switching hardware.\u003c\/p\u003e\n\n\u003ch3\u003eAdvanced Safety and Load Protection\u003c\/h3\u003e\n\u003cp\u003eOnboard hardware protections defend the control node from erratic field events. Active overvoltage protection shields internal lines against induction spikes, while short circuit protection limits current surges to secure uninterrupted network operation.\u003c\/p\u003e\n\n\u003ch3\u003eComprehensive Visual Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe hardware features a matrix of 16 individual diagnostic status LEDs aligned with an active self-diagnostics auto-check subsystem, allowing field technicians to identify channel states and loop health immediately.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #1a365d; color: #ffffff;\"\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eValue \/ Operational Limit\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCC-TDOR01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e51308376-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eDigital Output Relay Module (Series C IOTA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e16 Discrete Relay Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eRelay Contact Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eNormally Open (NO) \/ Normally Closed (NC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eInput Power Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e24 V DC ± 10%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eActive Power Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e4 W maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModbus RTU over RS-485 Interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e-10°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eRelative Humidity Limits\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0% to 95% (Non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eMechanical DIN Rail Mounting\u003c\/h3\u003e\n\u003cp\u003eMount the 0.5 kg assembly horizontally onto a standard 35mm DIN rail profile inside the marshalling cabinet. Ensure rigid latch engagement with the rail track to minimize environmental vibration or physical alignment drift during fast mechanical relay actuation cycles.\u003c\/p\u003e\n\n\u003ch3\u003eSecure Terminal Wiring\u003c\/h3\u003e\n\u003cp\u003eConnect field control lines using the robust integrated screw terminals. Route inductive load cables separated from low-voltage communications lines. Terminate connections firmly to prevent contact heating and ensure stable transmission across all 16 discrete outputs.\u003c\/p\u003e\n\n\u003ch3\u003eRS-485 Bus Integration\u003c\/h3\u003e\n\u003cp\u003eWhen running Modbus RTU telemetry over the RS-485 communication link, utilize standard shielded twisted-pair cables. Ground the communication line shield loop at a single node to eliminate data distortions induced by magnetic common-mode noise fields.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eNative Series C Architecture Integration\u003c\/h3\u003e\n\u003cp\u003eThis module provides drop-in mechanical and digital compatibility with Honeywell Series C IOTA systems, dropping installation times and guaranteeing native signal processing speeds without system bus delays.\u003c\/p\u003e\n\n\u003ch3\u003eExtended Operational Temperature Lines\u003c\/h3\u003e\n\u003cp\u003eThe thermal-hardened components ensure reliable relay contact switching from extreme cold states at -10°C up to high-density cabinet temperatures hitting +60°C without contact timing drift.\u003c\/p\u003e\n\n\u003ch3\u003eDistributed Modbus Connectivity\u003c\/h3\u003e\n\u003cp\u003eIncorporating direct Modbus RTU communications across RS-485 data paths permits versatile remote mounting schemes, giving engineering firms the freedom to place control rows close to the active field equipment.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What power fluctuations can the internal 24 V DC circuit safely tolerate?\u003c\/strong\u003e\u003cbr\u003e\nA1: The module accepts a continuous voltage variance line of ± 10%, keeping its 16 status LEDs and switching logic operational during auxiliary power fluctuations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How do technicians identify an inactive channel or failed module state?\u003c\/strong\u003e\u003cbr\u003e\nA2: The hardware executes automated internal self-diagnostics checks. Any discrepancies or failures can be identified by cross-referencing the 16 onboard status LEDs or reading diagnostic registers over the Modbus interface.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module manage inductive AC field loads directly?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, through its isolated Normally Open\/Closed dry contacts. However, deploying external RC snubbers or suppressing diodes across inductive loads is recommended to protect the internal contacts from arc wear.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050791895172,"sku":"CC-TDOR01","price":274.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TDOR01-4.jpg?v=1779548735"},{"product_id":"abb-cma132-3dde300412-generator-relay-terminal-board","title":"ABB CMA132 3DDE300412 Generator Relay Terminal Board","description":"\u003ch2\u003eABB CMA132 3DDE300412 Generator Relay Terminal Board\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eABB CMA132 3DDE300412\u003c\/strong\u003e | Generator Relay Terminal Board designed for reliable control and protection in power generation applications. Provides secure termination and interface for generator relay systems. DIN rail mounting simplifies installation in control cabinets.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e12 V DC ± 10% input voltage. 5 A current rating. Screw terminal connectors for secure wiring. DIN rail mounting for easy installation. Phenolic resin with glass fiber construction for durability. IP20 protection for control cabinet environments. Wide operating temperature -20°C to +55°C. Insulation resistance ≥ 100 MΩ.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003eCMA132 3DDE300412\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003eGenerator Relay Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127 mm x 203 mm x 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e12 V DC ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePhenolic resin with glass fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e≥ 100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMount on standard DIN rail inside control cabinet. Use appropriate wire gauges for 5 A current rating. Ensure 12 V DC supply within ±10% tolerance. IP20 rating requires installation in protected environment. Maintain ambient temperature within -20°C to +55°C range.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eProvides reliable termination and interface for generator relay systems. Phenolic resin with glass fiber construction ensures mechanical strength and insulation integrity. Screw terminals enable secure and maintainable wiring connections. Compact design saves cabinet space. Suitable for demanding power generation environments.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the input voltage requirement?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e The board operates at 12 V DC ± 10% input voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What type of mounting does this board support?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e The board is designed for standard DIN rail mounting inside control cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the insulation resistance rating?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e The board provides insulation resistance of ≥ 100 MΩ for reliable electrical isolation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050792288388,"sku":"CMA132","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CMA1323DDE300412_3.jpg?v=1786788674"},{"product_id":"allen-bradley-1746-ox8-relay-output-module-slc-500","title":"Allen-Bradley 1746-OX8 Relay Output Module | SLC 500","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley SLC 500 Digital DC Output Module 1746-OX8\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1746-OX8\u003c\/strong\u003e is an 8-channel isolated relay output module for the SLC 500 PLC system. It provides flexible switching for AC and DC loads, making it ideal for mixed-voltage industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Allen-Bradley \u003cstrong\u003e1746-OX8\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SLC 500 I\/O Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e 8-Channel Isolated Relay Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Form-C Relay Contacts (SPDT)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 5-265V AC, 5-125V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 3A @ 120V AC, 1.2A @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load:\u003c\/strong\u003e 10A inrush per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Individual channel isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e Per-channel LED for output state\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e SLC 500 rack or DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 0.57 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x 1746-OX8 output module\u003c\/li\u003e\n\u003cli\u003eApproximate shipping weight: 0.9 kg\u003c\/li\u003e\n\u003cli\u003eSecure protective packaging\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat types of loads can this module control?\u003c\/strong\u003e\u003cbr\u003eIt can control a wide variety of loads including motor starters, solenoid valves, indicator lamps, and small heaters, using either AC or DC power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Form-C relay\" mean?\u003c\/strong\u003e\u003cbr\u003eForm-C (SPDT) relays provide one common terminal, one normally open (NO) contact, and one normally closed (NC) contact per channel, offering wiring versatility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I mix AC and DC loads on the same module?\u003c\/strong\u003e\u003cbr\u003eYes, each channel is isolated, allowing you to control AC loads on some channels and DC loads on others simultaneously, as long as the voltage and current ratings are observed per channel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050795729028,"sku":"1746-OX8","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1746-OX8-1.jpg?v=1769005377"},{"product_id":"abb-ndio-02-digital-i-o-extension-module-2-inputs-2-relays","title":"ABB NDIO-02 Digital I\/O Extension Module | 2 Inputs 2 Relays","description":"\u003ch2 style=\"color: #0055A4;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0055A4;\"\u003eABB NDIO-02\u003c\/strong\u003e is a compact digital I\/O extension module that adds 2 digital inputs and 2 relay outputs to your control system. Ideal for small-scale automation needs, this 22mm-wide module mounts on DIN rail and integrates seamlessly with ABB AC500 PLCs and most automation platforms.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eCore Functionality\u003c\/h2\u003e\n\u003cp\u003eThe NDIO-02 provides 2 digital input channels at 24V DC and 2 relay outputs rated at 5A 250V AC. Response time is 10ms maximum, ensuring reliable signal processing. Spring-clamp terminals simplify wiring. LED indicators show channel status at a glance. Operating temperature ranges from -25°C to +55°C for demanding environments.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n  \u003ctr style=\"background:#f2f2f2;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eNDIO-02\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e2 channels, 24V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRelay Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e2 relays, 5A 250V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eResponse Time\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e≤10ms\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSupply Voltage\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e24V DC ±10%\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eIsolation\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e1500V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWidth\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e22mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e-25°C to +55°C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e~0.12 kg (0.26 lbs)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTerminals\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSpring-clamp\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCertifications\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCE, UL, cUL, RoHS\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eMount the NDIO-02 on standard DIN rail (35mm). Connect 24V DC power observing polarity. Wire inputs to channels 1-2 and relay outputs to channels 3-4 using spring-clamp terminals. Secure with end clamp. Verify LED indicators show correct power and channel status.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe NDIO-02 delivers 1500V AC isolation protecting the control system. The space-saving 22mm design maximizes panel density. Spring-clamp terminals reduce wiring time. Wide -25°C to +55°C range supports harsh environments. Relay outputs rated 5A handle motors and solenoids directly. At just 0.12 kg, it minimizes DIN rail loading.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Compatible with ABB AC500?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes. Direct integration with AC500 PLCs. Also works with most automation systems via standard I\/O interfacing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Response time and protection?\u003c\/strong\u003e\u003cbr\u003e\nA2: 10ms max response. 1500V AC isolation. LED indicators show power and channel status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Output relay ratings?\u003c\/strong\u003e\u003cbr\u003e\nA3: 5A at 250V AC. Suitable for solenoids, contactors, indicators, and small motors.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050795794564,"sku":"NDIO‑02","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/NDIO-02-2.jpg?v=1786799448"},{"product_id":"ge-fanuc-ic693mdl930-8-channel-relay-output-module","title":"GE Fanuc IC693MDL930 8-Channel Relay Output Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc IC693MDL930 is an 8-channel isolated relay discrete output module designed for the Series 90-30 programmable logic controller (PLC) system. This versatile module features eight independent, normally open (Form A) relay circuits that allow the PLC to interface with external actuators, solenoids, motor starters, and pilot indicators. By providing complete electrical isolation between internal logic and external field wiring, the IC693MDL930 enables seamless, concurrent control of both AC and DC industrial loads from a single PLC rack assembly.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003eCore Technical Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC693MDL930 utilizes high-reliability mechanical relays that provide independent power isolation for each of its eight output points. It handles a wide range of switching voltages—up to 30 VDC or 250 VAC—offering great application flexibility. The modular design drops tool-less swap-out times dramatically, plugging directly into any standard I\/O slot of a Series 90-30 baseplate. Low internal power consumption preserves system energy efficiency while minimizing thermal generation within local panel layouts.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px; width: 35%;\"\u003eModel Designation\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eIC693MDL930\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eGE Fanuc Series 90-30 PLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eOutput Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eDiscrete Isolated Relay (Form A - Normally Open)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eChannel Count\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e8 independent isolated channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eNominal Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e24 VDC \/ 120 VAC \/ 240 VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eOperating Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e5 to 30 VDC \/ 5 to 250 VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eMax Continuous Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e2 A per point (maximum resistive rating)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eMaximum Inrush Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e5 A per channel (maximum spike duration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eResponse Time\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e15 ms maximum activation\/deactivation delay\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e0°C to +50°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e0.35 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003ch3\u003eMechanical Mounting and Slot Insertion\u003c\/h3\u003e\n\u003cp\u003eTurn off the main rack power before installing the module. Align the top hook of the IC693MDL930 housing with the retention slot on the Series 90-30 baseplate. Pivot the module downward until the rear bus connector snaps securely into the backplane, then tighten the bottom securing screw.\u003c\/p\u003e\n\u003ch3\u003eField Terminal Blocks and Wiring\u003c\/h3\u003e\n\u003cp\u003eSwing open the front terminal door to access the screw connectors. Connect individual field circuits using up to 14 AWG wire leads. Because each channel is fully isolated, you can mix distinct AC and DC supply loops across adjacent terminals without introducing cross-talk or short circuits.\u003c\/p\u003e\n\u003ch3\u003eSurge Suppression for Inductive Loads\u003c\/h3\u003e\n\u003cp\u003eWhen switching inductive loads like relay coils, magnetic starters, or solenoids, install external noise suppression components. Wire a commutation diode across DC circuits, or snap a metal oxide varistor (MOV) network across AC loads to suppress voltage arcs and extend mechanical relay life.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eIsolated Multi-Voltage Management\u003c\/h3\u003e\n\u003cp\u003eThe channel-to-channel isolation on the IC693MDL930 eliminates the need for separate DC and AC output cards. Engineers can control high-current 240 VAC mechanisms and low-signal 24 VDC indication lines on a single hardware block, optimizing total system layout costs.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Protection and Visibility\u003c\/h3\u003e\n\u003cp\u003eThe module includes a removable front terminal block, allowing maintenance teams to swap module electronics without disconnecting field wires. Front-facing LED indicators display the real-time ON\/OFF state of each logic channel, providing instant diagnostic visibility for field technicians.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use the IC693MDL930 to switch extremely low signal current lines?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes, the contact resistance accommodates signals down to 5V. However, mechanical contacts require a minimum wetting current (typically 10 mA) to reliably break through microscopic surface oxidation over long periods of operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if an output circuit demands more than the 5 A peak inrush rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Exceeding the inrush parameters can cause contact arcing, which may pit or weld the physical relay contacts closed. For large loads or motor coils with severe surge cycles, use this module to switch an external interposing contactor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why is the module's response time listed at 15 ms compared to electronic solid-state cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Solid-state cards switch using transistors or triacs almost instantly, whereas the IC693MDL930 relies on physical mechanical movement to snap the relay arm into place, which requires a brief 15 ms activation delay.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050797006980,"sku":"IC693MDL930","price":137.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693MDL930-2.jpg?v=1782654721"},{"product_id":"do820-230v-ac-dc-relay-output-module-abb","title":"DO820 230V AC\/DC Relay Output Module - ABB","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eABB presents the \u003cstrong style=\"color: #2e86ab;\"\u003eDO820\u003c\/strong\u003e relay output module, delivering robust high-voltage control for S800 I\/O systems. This advanced module combines eight isolated relay channels with comprehensive safety features for industrial automation applications.\u003c\/p\u003e\n\u003ch3\u003eKey Functional Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e8 isolated relay channels\u003c\/strong\u003e for high-voltage control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 230V AC\/DC operation (5-250V rated range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e3A maximum current\u003c\/strong\u003e per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Normally Open (NO) relay configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indication:\u003c\/strong\u003e LED indicators for each output channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety \u0026amp; Protection Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOSP Functionality:\u003c\/strong\u003e Automatic failover to predefined safe states\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Protection:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e2000V AC dielectric strength\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Supervision:\u003c\/strong\u003e Continuous 24V power monitoring via ModuleBus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Isolation:\u003c\/strong\u003e Enhanced circuit safety barriers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnomaly Detection:\u003c\/strong\u003e Automatic warning triggers for power issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e2000V AC\u003c\/strong\u003e isolation protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Rating:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e250V\u003c\/strong\u003e channel-to-ground rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Accuracy:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0 to +1.3 ms\u003c\/strong\u003e response timing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e2.9W\u003c\/strong\u003e typical consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Cable Length:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e600 meters\u003c\/strong\u003e maximum reach\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Consumption Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus +5V:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e60 mA\u003c\/strong\u003e current requirement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus +24V:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e140 mA\u003c\/strong\u003e current draw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power:\u003c\/strong\u003e No additional 24V source needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e Optimized power management system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0 to +55°C\u003c\/strong\u003e standard range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e-40 to +70°C\u003c\/strong\u003e robust tolerance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e5 to 95%\u003c\/strong\u003e non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical Mounting:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e40°C\u003c\/strong\u003e maximum ambient temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e Level 2 (IEC 60664-1 compliant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0.23 kg\u003c\/strong\u003e compact design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e S800 standard mechanics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20 enclosure classification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation Download\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete technical specifications available\u003c\/li\u003e\n\u003cli\u003eInstallation and configuration guidelines\u003c\/li\u003e\n\u003cli\u003eSafety and compliance documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/Product-DO820.pdf?v=1752112819\" target=\"_blank\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum switching capacity?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eDO820\u003c\/strong\u003e handles \u003cstrong style=\"color: #2e86ab;\"\u003e250V AC\/DC at 3A\u003c\/strong\u003e per channel with NO contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does the OSP safety feature work?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eOutput Set Point function\u003c\/strong\u003e automatically sets outputs to predetermined safe states upon fault detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat isolation protection is provided?\u003c\/strong\u003e\u003cbr\u003eThe module offers \u003cstrong style=\"color: #2e86ab;\"\u003e2000V AC dielectric strength\u003c\/strong\u003e with individual channel isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eContact Information\u003c\/h3\u003e\n\u003cp\u003eFor pricing and technical support, please contact: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050797301892,"sku":"DO820","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DO820-4.jpg?v=1763284177"},{"product_id":"do820-relay-output-module-abb-3bse008514r1-230v","title":"DO820 Relay Output Module | ABB 3BSE008514R1 230V","description":"\u003ch2\u003eABB DO820 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eHigh-performance 8-channel relay output module designed for industrial automation with 230V AC\/DC switching capability.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003eDO820\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle Number:\u003c\/strong\u003e 3BSE008514R1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical System:\u003c\/strong\u003e S800 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 8 relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 5-250V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 3A per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Relay (Normally Open)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage:\u003c\/strong\u003e 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Test Voltage:\u003c\/strong\u003e 2000V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 2.9W typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 45mm × 119mm × 102mm (W×H×D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth with Connector:\u003c\/strong\u003e 111mm (4.37 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.23kg (0.5lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e DIN Rail compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 according to IEC 60529\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeying Code:\u003c\/strong\u003e AD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndividual channel isolation\u003c\/li\u003e\n\u003cli\u003eChannel-to-channel isolation\u003c\/li\u003e\n\u003cli\u003eCurrent limiting capability via MTU\u003c\/li\u003e\n\u003cli\u003eEvent recording accuracy: -0ms \/ +1.3ms\u003c\/li\u003e\n\u003cli\u003eMaximum field cable length: 600 meters\u003c\/li\u003e\n\u003cli\u003eHot-swappable operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFront LED indicators: Fault, Run, Warning, OSP\u003c\/li\u003e\n\u003cli\u003eIndividual channel status LEDs (1-8)\u003c\/li\u003e\n\u003cli\u003e24\/12V relay power converter monitoring\u003c\/li\u003e\n\u003cli\u003eModule error and warning indications\u003c\/li\u003e\n\u003cli\u003eChannel error status detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e+5V Modulebus Current:\u003c\/strong\u003e 60mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+24V Modulebus Current:\u003c\/strong\u003e 140mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+24V External Current:\u003c\/strong\u003e 0mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Power Consumption:\u003c\/strong\u003e 2.9W typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +55°C (32°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +70°C (-40°F to 158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e Degree 2, IEC 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e ISA-S71.04: G3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Ambient Temperature:\u003c\/strong\u003e 55°C (131°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark Certified\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant (DIRECTIVE\/2011\/65\/EN)\u003c\/li\u003e\n\u003cli\u003eWEEE Compliant (DIRECTIVE\/2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003eElectrical Safety: EN 61010-1, UL 61010-1\u003c\/li\u003e\n\u003cli\u003eEMC: EN 61000-6-4, EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003eMarine Certifications: ABS, BV, DNV, LR\u003c\/li\u003e\n\u003cli\u003eEquipment Class: Class I (earth protected)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible MTUs:\u003c\/strong\u003e TU811, TU813, TU831, TU836, TU837, TU851\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e S800 I\/O System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Modulebus backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeatures Not Supported:\u003c\/strong\u003e HART, SOE, Redundancy, High Integrity, Intrinsic Safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eProper grounding required\u003c\/li\u003e\n\u003cli\u003eAdequate ventilation space\u003c\/li\u003e\n\u003cli\u003eVertical mounting recommended\u003c\/li\u003e\n\u003cli\u003eScrew terminal connections\u003c\/li\u003e\n\u003cli\u003eField wiring up to 600 meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #a23b72;\"\u003e\u003cstrong\u003e12-Month Manufacturer Warranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eTechnical support available\u003c\/li\u003e\n\u003cli\u003eGlobal service network\u003c\/li\u003e\n\u003cli\u003eOnline documentation access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat voltage range does this module support?\u003c\/strong\u003e\u003cbr\u003e5-250V AC\/DC on all 8 relay output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes, it supports hot-swapping during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the warranty period?\u003c\/strong\u003e\u003cbr\u003e12-month manufacturer warranty included.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050797334660,"sku":"3BSE008514R1","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DO820-1.jpg?v=1761482101"},{"product_id":"honeywell-fc-tsro-08uni-8-channel-sil3-safe-relay-output-fta","title":"Honeywell FC-TSRO-08UNI 8-Channel SIL3 Safe Relay Output FTA","description":"\u003ch2\u003eHoneywell TSRO-08UNI Safe Relay Output FTA Module\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong style=\"color: #2e86c1;\"\u003eFS-TSRO-08UNI\u003c\/strong\u003e and \u003cstrong style=\"color: #2e86c1;\"\u003eFC-TSRO-08UNI\u003c\/strong\u003e are Field Termination Assembly modules. They provide eight SIL3 relay outputs for Safety Manager systems.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides \u003cstrong style=\"color: #27ae60;\"\u003e8 safe output channels\u003c\/strong\u003e for SIL3 applications\u003c\/li\u003e\n\u003cli\u003eEach channel has three relays and a fused NO contact\u003c\/li\u003e\n\u003cli\u003eConnects SICC-0001\/Lx system cable to field wiring\u003c\/li\u003e\n\u003cli\u003eMeets IEC 61508 SIL3 requirements without fault exclusions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eFS-TSRO-08UNI\u003c\/strong\u003e \/ \u003cstrong\u003eFC-TSRO-08UNI\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Level:\u003c\/strong\u003e Up to SIL3 (IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 V DC nominal (36 V DC max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 8 independent relay channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 2 A max (fused), 1 mA min at 5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 250 V AC \/ 250 V DC max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched Load:\u003c\/strong\u003e 500 VA \/ 150 W max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse:\u003c\/strong\u003e 2 A, 5×20 mm, 250 V AC \/ 300 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 274 × 109 × 71 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN EN rails TS32\/TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Terminals:\u003c\/strong\u003e 2.5 mm² max, 0.5 Nm torque\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Terminals:\u003c\/strong\u003e 16 mm² max, 1.2 Nm torque\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e –5°C to +60°C operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelay Contact Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e250 V AC at 2 A maximum\u003c\/li\u003e\n\u003cli\u003e24 V DC at 2 A maximum\u003c\/li\u003e\n\u003cli\u003e48 V DC at 1 A maximum\u003c\/li\u003e\n\u003cli\u003e110 V DC at 500 mA maximum\u003c\/li\u003e\n\u003cli\u003eSwitching frequency: 20 Hz max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhat is the TSRO-08UNI module's safety rating?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Honeywell \u003cstrong\u003eTSRO-08UNI\u003c\/strong\u003e is rated for SIL3 applications per IEC 61508.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow many outputs does this module have?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIt provides \u003cstrong style=\"color: #27ae60;\"\u003e8 independent relay output channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is the maximum switching voltage?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe relays can switch up to 250 V AC and 250 V DC maximum.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050804019332,"sku":"FC-TSRO-08UNI","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-TSRO-08UNI-1.jpg?v=1767534574"},{"product_id":"ic693mdl390-ge-fanuc-500v-channel-isolated-16-point-switching-unit","title":"IC693MDL390 GE Fanuc 500V Kanaal Geïsoleerde 16-Punts Schakelen Unit","description":"\u003ch2 style=\"color: #1976d2; font-weight: bold; font-size: 1.6em; margin-bottom: 15px;\"\u003e\n  \u003cspan style=\"color: #1976d2; font-weight: bold;\"\u003eGE Fanuc IC693MDL390\u003c\/span\u003e Discrete geïsoleerde uitgangsmoduul\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 1em; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  De module functioneert als een hoogdichtheid, betrouwbare schakelverbinding ontworpen voor gebruik binnen GE Series 90-30 programmeerbare logische controller chassis. Met een gewicht van precies 0,30 kg maakt deze compacte discrete solid-state kaart gebruik van zware triac-componenten om externe zware wisselstroomcircuits tot 240V AC aan te sturen, met een robuuste 500V continue kanaal-naar-kanaal isolatiearchitectuur om lokale logische registers te beveiligen tegen inductieve veldterugslagen en tijdelijke ruispieken.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnische specificaties\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 0.95em;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333; width: 40%;\"\u003eFabrikant\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eGeneral Electric (GE Fanuc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eProductmodel \/ onderdeel-ID\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eIC693MDL390\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eSysteemlijnserie\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eSeries 90-30 PLC systeembasis\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eComponentinterfaceprofiel\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eDiscrete geïsoleerde uitgangsmoduul (Triac-indeling)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eDielektrische isolatiebarrière\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e500 V continu (kanaal-naar-kanaal) | 1500 V AC gedurende 1 minuut (veld-naar-logica)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eMaximale inschakelstroom\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e25 A maximale duurpiek beperkt tot 1 volledige stroomcyclus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eHoge-snelheid inschakelrespons\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eAAN-stand: ≤ 1 ms uitvoeringstijd | UIT-stand: ≤ ½ AC-lijncyclus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eUitgangslekkage in uit-stand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e3 mA max @ 120 V AC | 6 mA max @ 240 V AC grenzen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eMinimale doelcircuitbelasting\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e100 mA continue actieve stroomopname per punt\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eInterne stroom- en backplane opname\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1,3 W maximale dissipatie per actief kanaal | 110 mA van 5V PLC backplane rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eBerekende systeem MTBF\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e200.000 operationele uren kernbetrouwbaarheidsindex\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eNetto gewicht hardware\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e0,30 kg \/ 0,66 lbs massa van het kale component\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eBuitenafmetingen kaart\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e105 mm × 100 mm × 35 mm sleufprofiel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eOmgevingsbedrijfsgrenzen\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eTemperatuur: -20°C tot 60°C | Hoogte: Tot 2000 meter operationele hoogte\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eGoedkeuringscertificaten\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eUL gecertificeerd, CE conform, RoHS structureel gecertificeerd\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eSnelle Installatiehandleiding\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eSchakel de hoofdvoeding van de programmeerbare controller backplane basis uit samen met alle aanvullende hoogspannings-AC veldvoedingskanalen.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eLijn de bovenste en onderste plastic structurele kaartgeleiders van de 0,30 kg IC693MDL390-modulekaart uit met de beoogde sleuf in de behuizing van de Series 90-30 basisplaat.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eDuw de printplaat van 0,30 kg stevig naar binnen totdat de interne achterste pinnematrix volledig vergrendelt met de connectorbaan van de basisplaat.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eBevestig het externe bedradingsterminalblok en controleer dat de belastingen niet onder de minimale limiet van 100 mA per punt komen, en sluit de beschermkap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnische FAQ's\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ1: Waarom is een minimale belastingsdrempel van 100 mA per punt noodzakelijk voor deze uitgangsmodule?\u003c\/strong\u003e\u003cbr\u003e\n  A1: De IC693MDL390-module maakt gebruik van solid-state triac-componenten voor vermogensmodulatie. Triacs vereisen een continue drempelstroom (houdstroom) om hun actieve geleidende toestand te behouden; als een kleine tussenliggende belasting minder dan 100 mA trekt, kan het circuit onverwacht uitvallen of niet uitschakelen vanwege residuele lekstroom over het snubberneta werk.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ2: Hoe beschermen de individuele 500V kanaal-tot-kanaal isolatiewaarden lokale veldapparatuur?\u003c\/strong\u003e\u003cbr\u003e\n  A2: Deze module heeft volledige isolatie tussen de punten. Dit betekent dat elk individueel uitgangskanaal op zijn eigen geïsoleerde gemeenschappelijke retourlijn werkt, waardoor fouten of spanningskortsluitingen op één extern veldapparaat niet kunnen overspringen naar aangrenzende circuits of de datastatus van naburige uitgangen kunnen veranderen.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ3: Kan deze lichte assemblage van 0,30 kg langdurige blootstelling aan extreme veldpaneelomstandigheden weerstaan?\u003c\/strong\u003e\u003cbr\u003e\n  A3: Ja. Ondanks het lichte gewicht van 0,30 kg is de module gebouwd met hoogwaardige surface-mount elektronica die geen actieve mechanische ventilatorkoeling vereist. Met een solide MTBF-waarde van 200.000 uur werkt hij betrouwbaar binnen een breed temperatuurbereik van -20°C tot 60°C op hoogtes tot 2000 meter.\n\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050812932228,"sku":"IC693MDL390","price":194.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693MDL390.jpg?v=1782136331"},{"product_id":"ic200ndr010-ge-fanuc-versamax-nano-plc-6-input-4-relay-12v","title":"IC200NDR010 GE Fanuc Versamax Nano PLC 6 Input 4 Relay 12V","description":"\u003ch2 style=\"color: #004080; font-weight: bold;\"\u003eGE Fanuc IC200NDR010 Versamax Nano PLC Controller\u003c\/h2\u003e\n\u003cp\u003eGE Fanuc \u003cstrong\u003eIC200NDR010\u003c\/strong\u003e Versamax Nano PLC controller. 10 I\/O points: 6 inputs, 4 relay outputs. 12 V DC, 9 mA. Supports up to 2048 I\/O points. RS-232 and RS-485 ports. Weight 0.45 kg.\u003c\/p\u003e\n\u003ch3 style=\"color: #004080;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC200NDR010\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Nano PLC controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 4 relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 12 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 9 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax I\/O Points Supported:\u003c\/strong\u003e 2048\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Load Range:\u003c\/strong\u003e 5-30 V DC or 5-250 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e RS-232, RS-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Ladder diagram, instruction list, function chart\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time Clock:\u003c\/strong\u003e Battery-backed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE, cULus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.45 kg (1.0 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #004080;\"\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC200NDR010\u003c\/strong\u003e Nano PLC controller\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003cli\u003eShipping: FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003e12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #004080;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: I\/O configuration?\u003c\/strong\u003e\u003cbr\u003eA: 6 inputs, 4 relay outputs at 12 V DC, 9 mA. Outputs control 5-30 V DC or 5-250 V AC loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Communication and programming?\u003c\/strong\u003e\u003cbr\u003eA: RS-232 and RS-485 ports. Supports ladder diagram, instruction list, and function chart programming.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Weight and environment?\u003c\/strong\u003e\u003cbr\u003eA: 0.45 kg, operating 0-55°C. Battery-backed real-time clock. Supports up to 2048 I\/O points. CE, cULus certified.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eContact: \u003ca href=\"mailto:sale@etowonauto.com\" style=\"color: #004080; font-weight: bold;\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050814341252,"sku":"IC200NDR010","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200NDR010.jpg?v=1774449314"},{"product_id":"general-electric-ic200mdl930-relay-output-module","title":"General Electric IC200MDL930 | Relay Output Module","description":"\u003ch2\u003eGeneral Electric IC200MDL930 Versamax Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IC200MDL930\u003c\/strong\u003e is an 8-point relay output module for Versamax I\/O systems. Features 8 individually isolated Normally Open (Form A) contacts. \u003c\/p\u003e\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric \/ Emerson Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e \u003cstrong\u003eIC200MDL930\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints:\u003c\/strong\u003e 8 relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact form:\u003c\/strong\u003e Normally Open (Form A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay type:\u003c\/strong\u003e Fixed coil, moving armature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Silver alloy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.45 kg (approx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVoltage \u0026amp; current ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC voltage range:\u003c\/strong\u003e 0 to 125V DC (5\/24\/125V nominal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC voltage range:\u003c\/strong\u003e 0 to 265V AC at 47-63Hz (120\/240V nominal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent rating (AC):\u003c\/strong\u003e 2.0A max for 5-265V AC (resistive)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent rating (DC 5-30V):\u003c\/strong\u003e 2.0A max (resistive)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent rating (DC 31-125V):\u003c\/strong\u003e 0.2A max (resistive)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum current:\u003c\/strong\u003e 10mA per point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResponse \u0026amp; power\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 10 ms max (on\/off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching frequency:\u003c\/strong\u003e 20 cycles per minute (inductive loads)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane current:\u003c\/strong\u003e 243 mA typical, 435 mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250V AC continuous, 1500V AC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput grouping:\u003c\/strong\u003e Individually isolated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat loads are compatible?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAC loads up to 265V and DC loads up to 125V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the response time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e10 ms maximum for both on and off transitions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it have internal fuses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Use external suppression for inductive loads.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050815815812,"sku":"IC200MDL930","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200MDL930.jpg?v=1774099450"},{"product_id":"vr-h4135-hima-safety-relay-24vdc-sil-3","title":"VR-H4135 HIMA - Safety Relay 24VDC SIL 3","description":"\u003ch2\u003e\u003cstrong\u003eHIMA VR-H4135 Safety Relay Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eVR-H4135\u003c\/strong\u003e from HIMA delivers reliable safety circuit control with SIL 3 certification according to IEC 61508 standards. This safety relay operates with 24VDC input voltage and features three output contacts for flexible safety system integration. With fast 30ms response time and robust construction, it ensures dependable performance in demanding industrial safety applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e VR-H4135\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Voltage:\u003c\/strong\u003e 24 VDC ±20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePower Consumption:\u003c\/strong\u003e Typically 2W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSafety Level:\u003c\/strong\u003e SIL 3 (IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eContact Rating:\u003c\/strong\u003e 5A at 250VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOutput Configuration:\u003c\/strong\u003e 2 NO, 1 NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eResponse Time:\u003c\/strong\u003e Typically 30 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eHousing Material:\u003c\/strong\u003e Flame retardant plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMounting Type:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDimensions:\u003c\/strong\u003e 90mm x 22.5mm x 114mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e Approx. 100g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCertifications:\u003c\/strong\u003e CE, UL listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Performance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSIL 3 certification ensures compliance with highest safety integrity levels\u003c\/li\u003e\n\u003cli\u003eDual normally-open contacts provide redundant safety circuit control\u003c\/li\u003e\n\u003cli\u003eSingle normally-closed contact offers additional monitoring capability\u003c\/li\u003e\n\u003cli\u003eFast 30ms response time quickly activates safety functions when needed\u003c\/li\u003e\n\u003cli\u003eComprehensive testing validates reliable operation in fault conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety certification does this relay have?\u003c\/strong\u003e SIL 3 according to IEC 61508 standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many contacts are provided?\u003c\/strong\u003e Two normally-open and one normally-closed contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum switching current?\u003c\/strong\u003e 5A at 250VAC rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51050817192068,"sku":"VR-H4135","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/VR-H4135_1140ad44-932f-4d81-befa-55a3cf1569f0.jpg?v=1764501545"},{"product_id":"05701-a-0329-relay-module-honeywell-triple-dpco-switching","title":"05701-A-0329 Relay Module - Honeywell Triple DPCO Switching","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell Triple DPCO Relay Module Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell Triple DPCO Relay Module\u003c\/strong\u003e provides reliable switching for industrial control applications. This pluggable module offers three double pole changeover relays.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Type:\u003c\/strong\u003e Triple Double Pole Changeover (DPCO)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e SPDT per relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24V DC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 grams\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 100 mm x 100 mm approximate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Pluggable for Honeywell control modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSwitching Capacity\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Switching:\u003c\/strong\u003e 250V, 8A resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Switching:\u003c\/strong\u003e 30V, 8A resistive load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Resistance:\u003c\/strong\u003e \u0026lt; 50mΩ maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500V AC contact-to-control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePerformance Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 10 ms switching operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 0.5W per relay typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Life:\u003c\/strong\u003e 100,000 operations minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBounce Time:\u003c\/strong\u003e \u0026lt; 3 ms maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 5g @ 10-150 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819387524,"sku":"05701-A-0329","price":276.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/05701-A-0329-1.jpg?v=1770383330"},{"product_id":"honeywell-05701-a-0327-control-relay","title":"Honeywell 05701-A-0327 Control Relay","description":"\u003ch2\u003eHoneywell 05701-A-0327 Relay Module\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003e05701-A-0327\u003c\/strong\u003e is a double SPCO relay module. It provides reliable switching for industrial control applications.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Honeywell \u003cstrong\u003e05701-A-0327\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e 5701 Series Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Type:\u003c\/strong\u003e Double SPCO (Single Pole Change Over)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 120 VAC \/ 28 VDC, 10A resistive \/ 7A inductive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Voltage:\u003c\/strong\u003e 24V AC\/DC or 120V AC options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C (-4°F to +140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Life:\u003c\/strong\u003e 100,000 operations at rated load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Life:\u003c\/strong\u003e 10 million operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel mount or DIN rail mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Screw terminal connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.00 lbs (0.45 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDouble SPCO contact configuration\u003c\/li\u003e\n\u003cli\u003eHigh 10A resistive \/ 7A inductive rating\u003c\/li\u003e\n\u003cli\u003eLong 10 million mechanical operations life\u003c\/li\u003e\n\u003cli\u003eDual mounting options: panel or DIN rail\u003c\/li\u003e\n\u003cli\u003eScrew terminal wiring for secure connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial control system switching\u003c\/li\u003e\n\u003cli\u003eMotor starter control circuits\u003c\/li\u003e\n\u003cli\u003eProcess control equipment\u003c\/li\u003e\n\u003cli\u003eAutomation system applications\u003c\/li\u003e\n\u003cli\u003eElectrical distribution control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e120 VAC \/ 28 VDC contact voltage rating\u003c\/li\u003e\n\u003cli\u003e10A resistive current capacity\u003c\/li\u003e\n\u003cli\u003e7A inductive load capacity\u003c\/li\u003e\n\u003cli\u003e24V AC\/DC or 120V AC coil options\u003c\/li\u003e\n\u003cli\u003e100,000 electrical operations life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackaging \u0026amp; Shipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003e05701-A-0327\u003c\/strong\u003e relay module\u003c\/li\u003e\n\u003cli\u003eMounting hardware included\u003c\/li\u003e\n\u003cli\u003eInstallation instructions\u003c\/li\u003e\n\u003cli\u003eShipped via major global carriers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of relay is this?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e \u003cstrong\u003e05701-A-0327\u003c\/strong\u003e is a double SPCO (Single Pole Change Over) relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the contact ratings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e 120 VAC \/ 28 VDC, 10A resistive \/ 7A inductive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What mounting options are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Panel mount or DIN rail mount options.\u003c\/p\u003e\n\u003cp\u003eFor support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003eContact Engineering Team\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819780740,"sku":"05701-A-0327","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/05701-A-0327-1.jpg?v=1770429969"},{"product_id":"ge-ic200mdl940-16-point-relay-versamax-output-module","title":"GE IC200MDL940 16-Point Relay | Versamax Output Module","description":"\u003ch2\u003eGeneral Electric IC200MDL940 Versamax Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IC200MDL940\u003c\/strong\u003e is a 16-point relay output module for Versamax I\/O systems. Features 16 individually isolated Normally Open (Form A) contacts. \u003c\/p\u003e\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric \/ Emerson Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e \u003cstrong\u003eIC200MDL940\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints:\u003c\/strong\u003e 16 relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact form:\u003c\/strong\u003e Normally Open (Form A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay type:\u003c\/strong\u003e Fixed coil, moving armature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Silver alloy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.55 kg (approx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the current rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2.0A for AC and low-voltage DC, 0.2A for 31-125V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the response time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e10 ms maximum for both on and off transitions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the outputs isolated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. All 16 channels are individually isolated.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050824564868,"sku":"IC200MDL940","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200MDL940-1.jpg?v=1774099763"},{"product_id":"ge-fanuc-ic693mdl916-series-90-30-16-channel-relay-output-module","title":"GE Fanuc IC693MDL916 Series 90-30 16-Channel Relay Output Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL916\u003c\/strong\u003e is a high-density, 16-channel Relay Output Module manufactured by GE Fanuc (now Emerson Automation) for the widely deployed Series 90-30 programmable logic controller system. This versatile module features 16 independent Form A (Normally Open) relay channels, providing a rugged physical interface between low-voltage PLC logic circuits and high-power field actuators.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Isolated Form A Channels:\u003c\/strong\u003e Every relay output is completely isolated from neighboring loops. This allows the system architecture to control a diverse mix of AC and DC voltage circuits simultaneously on the same hardware block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Load Switching:\u003c\/strong\u003e Capable of handling substantial current up to 4 Amps per output under standard voltage limits, or managing inductive field loads via a robust 2 Amp Pilot Duty rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRigid Dual-Layer Isolation Barrier:\u003c\/strong\u003e Offers heavy protection for the central processor with a continuous 250V AC field-to-backplane isolation ceiling, fortified by a 1-minute high-voltage withstand rating of 1550V AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIC693MDL916\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc Series 90-30 PLC Framework\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Contact Arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e16 Form A (Normally Open) relay channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating AC Voltage Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5 to 250 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating DC Voltage Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5 to 125 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4 Amps per output (AC: 5-250V, DC: 5-30V) \/ 200 mA at 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMinimum Required Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e10 milliamps (mA) continuous current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum Switching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eUp to 20 cycles per minute (under full rated load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eExpected Mechanical Lifespan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eRated for 100,000 operations minimum at full electrical load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.32 kg (0.7 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Control Center (MCC) Interfacing:\u003c\/strong\u003e Safely triggers high-current contactor coils, industrial motor starters, and local control relays from standard PLC registers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Treatment Pump Management:\u003c\/strong\u003e Operates chemical dosing solenoids, valve actuators, and local status alarm indicators across remote water treatment panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFacility Lighting and Power Circuits:\u003c\/strong\u003e Commands auxiliary lighting rows, exhaust fan dampers, and localized facility alarms across commercial or factory panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy Machinery Automation Assemblies:\u003c\/strong\u003e Manages hydraulic directional control valves and pneumatic pilot blocks in stamping, casting, or packaging cells.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual Channel Terminal Mapping:\u003c\/strong\u003e Wire each load through its own dedicated output screw terminal and independent return path, as there are no shared internal commons on this module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Suppression:\u003c\/strong\u003e When driving highly inductive devices like motor starters or solenoid coils, install external suppression devices (snubbers for AC, flyback diodes for DC) to prevent arc-induced contact degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Switching Thresholds:\u003c\/strong\u003e Ensure that connected field indicators or inputs draw at least 10 mA of active current to maintain optimal contact cleaning action and prevent signaling issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-Swapping Safety Protocol:\u003c\/strong\u003e Always turn off the primary chassis backplane supply and remove all high-voltage field power sources from the terminal block assembly prior to sliding the card out of its slot tracks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal DC Flexibility:\u003c\/strong\u003e Optimized to perform consistently across common industrial supply baselines, including both 12V DC and 24V DC standard control architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElimination of Interposing Relays:\u003c\/strong\u003e The direct 4 Amp switching threshold allows the module to command many field devices directly, eliminating intermediate relays to save panel space and wiring labor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Cycle Reliability:\u003c\/strong\u003e The robust mechanical construction easily tolerates repetitive sequence steps, sustaining up to 20 cycles per minute while maintaining a stable mechanical lifecycle profile.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I wire some channels for 230V AC and other channels for 24V DC on the same IC693MDL916 module?\u003c\/strong\u003e\u003cbr\u003eA1: Yes. Because every single channel is completely isolated from all others on the board, you can safely mix different voltage levels and power phases across the 16 available terminals without risk of short-circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Why is the maximum current rating reduced to 200 mA when switching a 125V DC circuit?\u003c\/strong\u003e\u003cbr\u003eA2: DC voltage circuits do not have natural zero-crossing points like AC loops. High-voltage DC creates much more severe contact arcing during opening cycles, requiring a lower current limit to maintain the rated life of the relay contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this relay output module require an external 24V DC power feed to operate its internal coils?\u003c\/strong\u003e\u003cbr\u003eA3: No external power is required to power the module electronics. The power necessary to actuate the internal mechanical relays is drawn directly from the +5V DC logic bus track on the Series 90-30 rack backplane.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050828923012,"sku":"IC693MDL916","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693MDL916-1.jpg?v=1779466761"},{"product_id":"ic693mdl931-ge-fanuc-8-point-nc-form-c-relay-output","title":"IC693MDL931 GE Fanuc 8-Point NC Form C Relay Output","description":"\u003ch2 style=\"color: #303f9f;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #303f9f;\"\u003eGE Fanuc IC693MDL931\u003c\/strong\u003e is an 8-point isolated relay output module designed for the Series 90-30 PLC environment. It is distinguished by its \"Isolated\" architecture, meaning each output point has its own common return, providing maximum electrical separation between channels. \u003cstrong\u003eWith a highly compact net weight of only 0.2 kg (0.44 lbs)\u003c\/strong\u003e, this module delivers significant switching power. It supports Form C and NC relay contacts, making it suitable for applications that require normally closed logic or changeover capabilities for 24VDC or 120\/240VAC loads.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #303f9f;\"\u003eIC693MDL931\u003c\/strong\u003e is built for high-capacity performance, featuring a maximum resistive load rating of 8 Amps per output. \u003cstrong\u003eThis 0.2 kg lightweight module\u003c\/strong\u003e offers professional-grade protection with a 1500 VAC isolation rating (for 1 minute) between field points and the PLC backplane. It consumes a mere 6 mA from the 5V bus, while the relay coils draw 110 mA from the 24V bus when fully energized. Its rapid response time of 15 ms and low leakage current (1 mA max) ensure precise and reliable operation for safety-interlock systems and motor starter control.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n    \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eFeature\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc (Emerson \/ Rockwell Automation)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIC693MDL931\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOutput Points\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8 (Fully Isolated)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMax Resistive Load\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8 Amps per point\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003e0.2 kg (0.44 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eVoltage Range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5-250 VAC \/ 5-30 VDC\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eInstallation \u0026amp; Thermal Management\u003c\/h2\u003e\n\u003cp\u003eInstallation of the \u003cstrong style=\"color: #303f9f;\"\u003eGE Fanuc IC693MDL931\u003c\/strong\u003e is seamless within any Series 90-30 I\/O slot. \u003cstrong\u003eDespite its 0.2 kg frame\u003c\/strong\u003e, the module can carry up to 20 Amps total for UL installations. It is crucial to monitor ambient temperature, as the total module current may require derating in hotter environments to prevent internal component fatigue. Wiring should account for the isolated nature of the points; because each output has an independent return, engineers can mix different power phases or DC sources across the eight channels without risk of cross-talk or short circuits.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #303f9f;\"\u003eIC693MDL931\u003c\/strong\u003e is an engineer's choice for complex signaling where isolation is paramount. The 8A inrush current capacity allows it to handle the initial surge of inductive loads like solenoids or small contactors. \u003cstrong\u003eThe module's 0.2 kg design\u003c\/strong\u003e includes Form C relays, providing both a normally open and normally closed contact for each point, which is essential for \"fail-safe\" logic applications. Furthermore, the point-to-point isolation eliminates the need for external interposing relays in many scenarios, saving both cost and panel space while maintaining 250 VAC continuous isolation.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the physical weight of the GE Fanuc IC693MDL931?\u003c\/strong\u003e\u003cbr\u003eA1: This module has a \u003cstrong\u003enet weight of 0.2 kg (0.44 lbs)\u003c\/strong\u003e, making it one of the lighter yet most robust relay modules in the Series 90-30 lineup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the benefit of an \"Isolated\" relay module?\u003c\/strong\u003e\u003cbr\u003eA2: Isolation allows each of the 8 relay outputs to operate with its own dedicated common, enabling you to switch different voltages or different phases on the same module safely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the IC693MDL931 support high-speed switching?\u003c\/strong\u003e\u003cbr\u003eA3: It has a response time of 15 ms for both On and Off states. While typical for mechanical relays, it is best suited for general control logic rather than high-speed pulse applications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050828955780,"sku":"IC693MDL931","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693MDL931-1.jpg?v=1778603684"},{"product_id":"ic694mdl930-ge-pacsystem-relay-module-5a-inrush-6ma-draw","title":"IC694MDL930 GE PACSystem Relay Module 5A Inrush 6mA Draw","description":"\u003ch2 style=\"color: #004080; font-weight: bold;\"\u003eGE Fanuc IC694MDL930 PACSystem RX3i Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eGE Fanuc \u003cstrong\u003eIC694MDL930\u003c\/strong\u003e PACSystem RX3i relay output module. 8 individually isolated Form A (Normally Open) outputs. 5-30 VDC and 5-250 VAC range, 4A max current per point, 10ms response. \u003c\/p\u003e\n\u003ch3 style=\"color: #004080;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL930\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc (Emerson Automation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystem RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Relay output module, Form A (N.O.) contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 8 individually isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage Range:\u003c\/strong\u003e 5-250 VAC (50\/60 Hz), nominal 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Range:\u003c\/strong\u003e 5-30 VDC, nominal 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Current:\u003c\/strong\u003e 4A resistive per point, 2A pilot duty per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Output Current:\u003c\/strong\u003e 10 mA per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 10-15 ms (on and off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Rating:\u003c\/strong\u003e 5.0 A maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Draw:\u003c\/strong\u003e 6 mA at 5V DC, 70 mA at 24V DC (all outputs ON)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.4 kg (0.88 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #004080;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Output configuration?\u003c\/strong\u003e\u003cbr\u003eA: 8 individually isolated Form A (N.O.) relay outputs. Dry contacts allow AC\/DC per channel: 5-250 VAC or 5-30 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Current and contact life?\u003c\/strong\u003e\u003cbr\u003eA: 4A max for resistive loads, 2A pilot duty. Contact life from 150,000 to 1,000,000 operations depending on load. 5.0A inrush rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Power and weight?\u003c\/strong\u003e\u003cbr\u003eA: 6mA backplane draw at 5V DC, 70mA at 24V DC. Weight 0.4kg. Compatible with RX3i and Series 90-30 systems. No internal fuses or snubbers.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eContact: \u003ca href=\"mailto:sale@etowonauto.com\" style=\"color: #004080; font-weight: bold;\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050830233732,"sku":"IC694MDL930","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL930-2.jpg?v=1774071722"},{"product_id":"ge-fanuc-ic697mdl940-series-90-70-16-channel-relay-output-module","title":"GE Fanuc IC697MDL940 Series 90-70 16-Channel Relay Output Module","description":"\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    The \u003cstrong style=\"color: #1a5276;\"\u003eGE Fanuc IC697MDL940\u003c\/strong\u003e is a versatile 16-channel relay output module engineered for the Series 90-70 Programmable Logic Controller system. This module provides a flexible interface between the PLC backplane and external field devices, utilizing a combination of eight Form C (Normally Open\/Normally Closed) and eight Form A (Normally Open) contacts. Designed for high reliability in complex switching applications, the IC697MDL940 supports a wide range of voltages, making it an essential component for controlling motors, valves, and indicators in diverse industrial settings.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\"\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n        \u003cth style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\"\u003eFeature\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eIC697MDL940 (Series 90-70)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e16 Total (8 Form C, 8 Form A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eRated Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e120\/240 VAC (Range: 5-265 VAC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eRated Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e5\/24\/125 VDC (Range: 5-30 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMaximum Load\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e2.0 Amps per contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eApproximately 150 g (0.33 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eBackplane Isolation\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e1500 Volts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e5.5 Watts\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3 style=\"color: #2980b9; font-size: 18px;\"\u003eMixed Contact Configuration\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003eThe IC697MDL940 distinguishes itself by offering both Form A and Form C relay types within a single module slot. This hybrid design allows engineers to handle both basic switching and changeover logic simultaneously, reducing the total number of modules required in the PLC rack.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2980b9; font-size: 18px;\"\u003eSuperior Inrush Handling\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003eBuilt to survive the demands of inductive loads, the module features silver-alloy contacts capable of managing an inrush current of up to 15A for 50ms. This ensures long-term contact durability when driving solenoids or small motor starters that exhibit high initial current spikes.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2980b9; font-size: 18px;\"\u003eHigh-Voltage Isolation Protection\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003eTo protect the sensitive Series 90-70 CPU and backplane, the IC697MDL940 provides 1500V isolation. This barrier prevents field-side electrical surges from migrating to the control logic, significantly increasing overall system uptime and safety.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.8; color: #34495e;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMechanical Keying:\u003c\/strong\u003e Utilize the module's unique keying feature to prevent accidental insertion into the wrong rack slot during field maintenance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFuse Protection:\u003c\/strong\u003e Each channel is protected by a 3A fuse. Always verify field load requirements do not exceed the 2.0A continuous rating to prevent nuisance blowing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eContact Lifespan:\u003c\/strong\u003e For high-frequency switching (exceeding 20 cycles per minute), consider external snubbers for inductive loads to extend the silver-alloy contact life beyond the standard 90,000-hour MTBF.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    The IC697MDL940 is optimized for rugged environments, maintaining full functionality across an operating temperature range of –25°C to 70°C. Despite its lightweight design of only 150 g, the module is built for industrial resilience. Its low internal power dissipation (5.5W) minimizes heat buildup within the PLC enclosure, while the 10mA minimum load capability ensures compatibility with modern electronic relay coils.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    \u003cstrong\u003eQ1: Can I mix AC and DC voltages on the same IC697MDL940 module?\u003c\/strong\u003e\u003cbr\u003e\n    A1: Yes. Relays are dry contacts, meaning you can switch different voltages on different channels, provided you observe group load limits and ensure proper wiring isolation between circuits.\n\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    \u003cstrong\u003eQ2: What is the difference between Form A and Form C contacts on this module?\u003c\/strong\u003e\u003cbr\u003e\n    A2: The module provides 8 Form A contacts (Normally Open) and 8 Form C contacts (Single Pole Double Throw). Form C contacts provide both a Normally Open and a Normally Closed terminal for every common wire.\n\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    \u003cstrong\u003eQ3: Is this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003e\n    A3: Standard Series 90-70 procedures require the system power to be off when removing or inserting modules to prevent backplane arcing and ensure data integrity.\n\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050833182852,"sku":"IC697MDL940","price":133.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697MDL940.jpg?v=1777379716"}],"url":"https:\/\/www.etowonauto.com\/nl\/collections\/relays-switches.oembed?page=9","provider":"Etowon Auto","version":"1.0","type":"link"}