{"product_id":"vfd900cp63a-00-90kw-high-voltage-drive-104a-light-duty-delta","title":"VFD900CP63A-00 90kW High Voltage Drive 104A Light Duty Delta","description":"\u003ch2\u003e\u003cstrong\u003eDelta VFD900CP63A-00 CP2000 Series Drive\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Delta \u003cstrong\u003eVFD900CP63A-00\u003c\/strong\u003e is a high-voltage industrial AC drive. It is part of the energy-efficient CP2000 series. This model delivers 125 HP (90 kW) output power. It operates on 690V three-phase power systems. The drive includes a built-in DC reactor for improved power quality. Its E frame design balances performance with space efficiency. This unit is ideal for medium-voltage industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Voltage Operation:\u003c\/strong\u003e 690V input for industrial power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficient:\u003c\/strong\u003e CP2000 series optimized for power savings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in DC Reactor:\u003c\/strong\u003e Enhances power factor and reduces harmonics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Current Ratings:\u003c\/strong\u003e Supports light duty (104A) and normal duty (86A) operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e E frame size ensures reliable performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComplete Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Delta\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003eVFD900CP63A-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e CP2000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 690V - 3 Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Power:\u003c\/strong\u003e 125 HP (90 kW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Duty Current:\u003c\/strong\u003e 104 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Duty Current:\u003c\/strong\u003e 86 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Size:\u003c\/strong\u003e E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP00 (Open Frame)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in EMC Filter:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Braking Chopper:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in DC Reactor:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 134.2 lbs (60.9 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 11.81\" x 14.57\" x 23.19\" (300mm x 370mm x 589mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Method:\u003c\/strong\u003e Forced air cooling with internal fan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Advanced vector control technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Frequency:\u003c\/strong\u003e Adjustable range 1-16 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e \u0026gt;97.5% typical at rated load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e -10°C to 50°C (14°F to 122°F) for operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -20°C to 65°C (-4°F to 149°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0-90% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Capacity:\u003c\/strong\u003e 110% for 60 seconds (normal duty)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Frequency:\u003c\/strong\u003e 50\/60 Hz ±5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Interface:\u003c\/strong\u003e Standard digital and analog I\/O included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Setup\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a suitable electrical enclosure (IP00 requires full environmental protection).\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation and clearance for proper airflow.\u003c\/li\u003e\n\u003cli\u003eUse correct wire sizes for 86-104A current ratings.\u003c\/li\u003e\n\u003cli\u003eAdd external EMC filter if required by application standards.\u003c\/li\u003e\n\u003cli\u003eInstall external braking unit and resistor for dynamic braking requirements.\u003c\/li\u003e\n\u003cli\u003eFollow all local electrical codes and safety regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-voltage pump systems in water treatment plants.\u003c\/li\u003e\n\u003cli\u003eIndustrial fans and blowers in manufacturing facilities.\u003c\/li\u003e\n\u003cli\u003eConveyor systems in mining and material handling.\u003c\/li\u003e\n\u003cli\u003eMixers and agitators in chemical processing plants.\u003c\/li\u003e\n\u003cli\u003eHVAC systems in large industrial buildings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the main advantages of 690V operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: 690V systems use lower current for the same power, reducing cable sizes and distribution losses. This is common in European and industrial power systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this drive have built-in braking capability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: No. For applications requiring rapid stopping or braking, you must install an external braking chopper and resistor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this drive be used in outdoor applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: No. The IP00 rating provides no protection against dust or moisture. It must be installed in a properly rated protective enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Delta","offers":[{"title":"Default Title","offer_id":51462171000964,"sku":"VFD900CP63A-00","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/VFD900CP63A-00.jpg?v=1769438694","url":"https:\/\/www.etowonauto.com\/nb\/products\/vfd900cp63a-00-90kw-high-voltage-drive-104a-light-duty-delta","provider":"Etowon Auto","version":"1.0","type":"link"}