{"product_id":"pepperl-fuchs-kcd2-scd-1-current-driver-signal-conditioner","title":"Pepperl+Fuchs KCD2-SCD-1 Current Driver | Signal Conditioner","description":"\u003ch2\u003eSMART KCD2-SCD-1 Current Driver Signal Conditioner\u003c\/h2\u003e\n\u003cp\u003eThe SMART \u003cstrong style=\"color: #d35400;\"\u003eKCD2-SCD-1\u003c\/strong\u003e is a precision current driver for process control. This 1-channel signal conditioner provides accurate current output. It supports HART communication with I\/P converters and valve positioners. The \u003cstrong\u003eKCD2-SCD-1\u003c\/strong\u003e ensures reliable operation in safety-critical applications up to SIL 2.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Identification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eKCD2-SCD-1\u003c\/strong\u003e current driver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 1-Channel Signal Conditioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e Current driving and conditioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e SIL 2 per IEC 61508 standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Width:\u003c\/strong\u003e 12.5 mm compact design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePower Supply Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e24 V DC nominal\u003c\/span\u003e (19-30 V DC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Power Rail or terminals 9+, 10-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e ≤ 30 mA power consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e ≤ 600 mW heat generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e ≤ 700 mW total usage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple Tolerance:\u003c\/strong\u003e ≤ 10 % input ripple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Analog 4-20 mA input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Terminals 5-, 6+ (control side)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 4-20 mA (limited to ~30 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e \u0026lt;23V or \u0026lt;27V configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e ~6V at 20 mA (\u0026lt;23V mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e \u0026gt;100 kΩ with open wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 4-20 mA precision signal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Capacity:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e0-650 Ω\u003c\/span\u003e maximum load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e ≥13 V at 20 mA output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Terminals 1+, 2- (field side)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Ripple:\u003c\/strong\u003e 20 mV rms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 0.1 % of full scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSafety \u0026amp; Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Level:\u003c\/strong\u003e SIL 2 per IEC 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Breakage Monitoring:\u003c\/strong\u003e Wire break detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Support:\u003c\/strong\u003e I\/P converter and valve positioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Fault detection capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Input\/output separation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount on standard DIN rail in control cabinet\u003c\/li\u003e\n\u003cli\u003eConnect 24V DC power via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eWire 4-20 mA input signal to control side terminals\u003c\/li\u003e\n\u003cli\u003eConnect output to field device (I\/P, positioner)\u003c\/li\u003e\n\u003cli\u003eConfigure voltage mode (\u0026lt;23V or \u0026lt;27V) as needed\u003c\/li\u003e\n\u003cli\u003eVerify grounding and shielding for noise immunity\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does SIL 2 certification mean for this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eKCD2-SCD-1\u003c\/strong\u003e meets Safety Integrity Level 2 requirements for use in safety instrumented systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this driver power two valves simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a 1-channel driver designed for single load devices up to 650 Ω.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does lead breakage monitoring work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt continuously monitors wire integrity and signals if a connection breaks.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePeriodic calibration check and visual inspection of connections are recommended.\u003c\/p\u003e\n\u003cp\u003eFor technical specifications or to order the \u003cstrong\u003eKCD2-SCD-1\u003c\/strong\u003e, contact \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eContent provided by Etowon Auto.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":51472469229700,"sku":"KCD2-SCD-1","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/KCD2-SCD-1-3.jpg?v=1768743199","url":"https:\/\/www.etowonauto.com\/nb\/products\/pepperl-fuchs-kcd2-scd-1-current-driver-signal-conditioner","provider":"Etowon Auto","version":"1.0","type":"link"}