{"product_id":"mtl-instruments-mtl5040-dual-channel-interface","title":"MTL Instruments MTL5040 Dual Channel Interface","description":"\u003ch2\u003e\u003cstrong\u003eMTL5040 Bidirectional Signal Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL5040\u003c\/strong\u003e from MTL Instruments provides versatile signal handling for hazardous areas. This dual-channel unit combines transmitter power supply with signal driving capabilities. It handles bidirectional communication between safe and hazardous areas with high precision and speed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eMTL Instruments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u003cstrong\u003eMTL5040\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eBidirectional Signal Interface\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eTwo independent channels\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 1 Function:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eTransmitter Power \u0026amp; Repeater\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 2 Function:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eSignal Driver to Hazardous Area\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e250µs typical\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Location:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eZone 0, IIC, T4-T6\u003c\/span\u003e hazardous area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDivision Rating:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDivision 1, Group A\u003c\/span\u003e hazardous location\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eMTL5040\u003c\/strong\u003e maintains intrinsic safety for both channels\u003c\/li\u003e\n\u003cli\u003eIt enables safe bidirectional signal transmission in explosive atmospheres\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eChannel 1 - Transmitter Repeater\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e0 to 24mA\u003c\/span\u003e from hazardous area transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e16.5V at 20mA\u003c\/span\u003e power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e4 to 20mA\u003c\/span\u003e to safe area (0-24mA range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e0 to 550Ω\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Terminals:\u003c\/strong\u003e Terminal 1 (Input –ve), Terminal 2 (Input +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminals:\u003c\/strong\u003e Terminal 11 (Output –ve), Terminal 12 (Output +ve)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eChannel 2 - Signal Driver\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e4 to 20mA\u003c\/span\u003e from safe area controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e4 to 20mA\u003c\/span\u003e to hazardous area load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e550Ω maximum\u003c\/span\u003e (11V at 20mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Drop:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;4V at 20mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Terminals:\u003c\/strong\u003e Terminal 8 (Input –ve), Terminal 9 (Input +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminals:\u003c\/strong\u003e Terminal 4 (Output –ve), Terminal 5 (Output +ve)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransfer Accuracy:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eBetter than 20µA at 20°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical Accuracy:\u003c\/strong\u003e Typically \u003cspan style=\"color: #2e75b6;\"\u003e5µA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Drift:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;1µA\/°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Settles within \u003cspan style=\"color: #2e75b6;\"\u003e250µs typical\u003c\/span\u003e to 10% of final value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Ripple:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;40µA peak-to-peak\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026gt;2MΩ\u003c\/span\u003e for both channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower \u0026amp; Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e95mA at 24V\u003c\/span\u003e with 20mA signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e1.6W at 24V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e250V AC\u003c\/span\u003e between all circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Green LED for power monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 1 Transmitter:\u003c\/strong\u003e Terminals 1-2 (Input), Terminals 11-12 (Output)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 2 Driver:\u003c\/strong\u003e Terminals 8-9 (Input), Terminals 4-5 (Output)\u003c\/li\u003e\n\u003cli\u003eClear terminal identification ensures correct wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e28V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e300Ω\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e93mA\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eUm = 250V rms or DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat makes the MTL5040 different from other repeaters?\u003c\/strong\u003e\u003cbr\u003eIt provides bidirectional capability - both powering transmitters and driving signals to hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat load capacity does each channel have?\u003c\/strong\u003e\u003cbr\u003eBoth channels support loads up to 550Ω with full signal accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast is the signal response?\u003c\/strong\u003e\u003cbr\u003eThe unit typically settles within 250 microseconds to 10% of final value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this suitable for controller output signals?\u003c\/strong\u003e\u003cbr\u003eYes, Channel 2 specifically handles 4-20mA signals from controllers to hazardous area loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":51268238246020,"sku":"MTL5040","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/MTL5040.jpg?v=1762682275","url":"https:\/\/www.etowonauto.com\/nb\/products\/mtl-instruments-mtl5040-dual-channel-interface","provider":"Etowon Auto","version":"1.0","type":"link"}