{"product_id":"ic200uex009-ge-fanuc-versamax-micro-expansion-unit-120vac","title":"IC200UEX009 GE Fanuc Versamax Micro Expansion Unit 120VAC","description":"\u003ch2 style=\"color: #2c3e50;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eIC200UEX009\u003c\/strong\u003e\u003c\/span\u003e is a high-utility expansion module from the Versamax Micro series, specifically built to handle high-voltage AC signals and significant output loads. This 14-point expansion unit provides \u003cstrong\u003e8 discrete 120VAC inputs\u003c\/strong\u003e and \u003cstrong\u003e6 relay outputs\u003c\/strong\u003e. What sets the \u003cstrong\u003eIC200UEX009\u003c\/strong\u003e apart is its specialized output configuration, which includes two independent high-capacity 10 Amp relays. Weighing in at \u003cstrong\u003e0.52 kg (1.15 lbs)\u003c\/strong\u003e, this unit is designed for heavy-duty industrial applications where robust power handling and reliable signal isolation are non-negotiable.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eThe primary advantage of the \u003cstrong\u003eIC200UEX009\u003c\/strong\u003e is its ability to interface directly with 120V AC field devices without the need for interposing relays or voltage converters. The output stage is highly flexible: it offers \u003cstrong\u003etwo 10 Amp individual outputs\u003c\/strong\u003e for heavy loads and \u003cstrong\u003efour 2 Amp outputs\u003c\/strong\u003e arranged in a single group for standard control tasks. This module is built for resilience, featuring an operating temperature range that extends from \u003cstrong\u003e-20°C to +55°C\u003c\/strong\u003e, ensuring it can perform in unheated or moderately high-temperature enclosures without failure. Furthermore, its storage temperature resilience up to 85°C makes it suitable for demanding global logistics and remote site storage.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003cth style=\"border: 1px solid #dee2e6; padding: 12px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dee2e6; padding: 12px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003eIC200UEX009\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e120V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eInput Count\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e8 Points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e6 Total (2 x 10A, 4 x 2A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e5% to 95% (Non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e-20°C to +55°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e0.52 kg (1.15 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cp\u003eWhen installing the \u003cstrong\u003eIC200UEX009\u003c\/strong\u003e, it is critical to account for the total current draw across the relay groups. For the four 2 Amp outputs, ensure the collective load does not exceed the group's rated capacity to prevent thermal stress. The 10 Amp individual outputs are ideal for direct control of small motors or heaters, but appropriate fuse protection should be placed on each line. Because this module interfaces with 120VAC, ensure that high-voltage and low-voltage wiring are kept separate within the cabinet to minimize noise. Standard DIN rail mounting is supported, and the unit should be placed in an environment with non-condensing humidity between 5% and 95%.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe IC200UEX009 offers a significant engineering advantage by reducing cabinet complexity. By providing 10 Amp relay contacts directly on the PLC expansion bus, it eliminates the costs associated with external contactors for many mid-sized loads. For the 120V AC inputs, the wide tolerance and industrial-grade debounce logic ensure that the PLC receives clean signals even in electrically noisy environments. This expansion unit is an excellent choice for retrofitting legacy systems where 120VAC infrastructure is already in place, allowing for a modern Versamax Micro upgrade without rewiring the field sensors.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Are the 10 Amp outputs isolated from each other?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes, the two 10 Amp relay outputs are individual, providing electrical isolation between them, which allows them to be used for different load types or circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this expansion module with any Versamax Micro controller?\u003c\/strong\u003e\u003cbr\u003e\nA2: The IC200UEX009 is compatible with Versamax Micro controllers that support expansion modules. Check your CPU's maximum I\/O limit and expansion port availability before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the benefit of 120VAC inputs versus 24VDC?\u003c\/strong\u003e\u003cbr\u003e\nA3: 120VAC inputs allow for direct connection to standard grid-powered sensors and switches, which is common in older industrial plants and building automation systems, reducing the need for an additional 24VDC power supply.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050825023620,"sku":"IC200UEX009","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200UEX009.jpg?v=1778510864","url":"https:\/\/www.etowonauto.com\/nb\/products\/ic200uex009-ge-fanuc-versamax-micro-expansion-unit-120vac","provider":"Etowon Auto","version":"1.0","type":"link"}