{"product_id":"ic200cbl545-ge-fanuc-versamax-cpu001-datapanel-cable","title":"IC200CBL545 GE Fanuc VersaMax CPU001 DataPanel Cable","description":"\u003ch2\u003eGE Fanuc IC200CBL545 VersaMax CPU001 RS-232 Communication Cable\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5276;\"\u003eGE Fanuc IC200CBL545\u003c\/strong\u003e is a serial communication cable designed for the VersaMax CPU001 to DataPanel 3x\/5x connection. Weighing 0.55 kg, it features a 9-pin D-sub connector and supports RS-232 serial communication for reliable data exchange between PLC and operator interface [citation:4][citation:6].\u003c\/p\u003e\n\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e IC200CBL545\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Serial Communication Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible CPU:\u003c\/strong\u003e VersaMax CPU001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e DataPanel 3x\/5x\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 60%;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e9-pin D-sub (DE-9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eCompatible CPU\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eVersaMax CPU001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eTarget Device\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eDataPanel 3x\/5x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePinout and Signal Information\u003c\/h3\u003e\n\u003cp\u003eThe DE-9 connector on the VersaMax CPU001 Port 1 follows the IBM-PC\/AT convention. The pin assignments are as follows [citation:6]:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 2 (RXD):\u003c\/strong\u003e Output from CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 3 (TXD):\u003c\/strong\u003e Input to CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 5 (GND):\u003c\/strong\u003e Ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 7 (RTS):\u003c\/strong\u003e Output from CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 8 (CTS):\u003c\/strong\u003e Input to CPU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCable Specifications\u003c\/h3\u003e\n\u003cp\u003eFor RS-232 communication, the maximum cable length is 15 meters (50 feet). The cable should be shielded to minimize electrical noise interference [citation:5]. The recommended cable type includes 5-conductor, 24 AWG tinned copper with braid over foil shield [citation:5].\u003c\/p\u003e\n\n\u003ch3\u003eConnection and Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnects VersaMax CPU001 to DataPanel 3x\/5x operator interfaces.\u003c\/li\u003e\n\u003cli\u003eSupports RS-232 serial communication for data exchange.\u003c\/li\u003e\n\u003cli\u003eDE-9 D-sub connector with standard pinout.\u003c\/li\u003e\n\u003cli\u003eWeight: 0.55 kg for reliable cable management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the maximum RS-232 cable length for the VersaMax CPU001?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Maximum length is 15 meters (50 feet) for RS-232 communication [citation:5].\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Does the IC200CBL545 require a null-modem connection?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Yes. For connection to a PC COM port, use a null-modem cable that crosses pins 2↔3 [citation:6].\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the weight of this cable?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e 0.55 kg [citation:4].\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52769361199236,"sku":"IC200CBL545","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200CBL545.jpg?v=1788680509","url":"https:\/\/www.etowonauto.com\/nb\/products\/ic200cbl545-ge-fanuc-versamax-cpu001-datapanel-cable","provider":"Etowon Auto","version":"1.0","type":"link"}