{"product_id":"honeywell-tc-ccn014-new-ccn-network-module","title":"Honeywell TC-CCN014 | New CCN Network Module","description":"\u003ch2 style=\"color: #2e86ab;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"color: #333; line-height: 1.6;\"\u003eThe \u003cstrong style=\"color: #003366;\"\u003eTC-CCN014\u003c\/strong\u003e serves as a high-performance communication bridge between legacy Carrier Control Network (CCN) systems and modern Ethernet-based management platforms. This Honeywell interface module integrates HVAC units and climate controls into a centralized network, ensuring real-time monitoring and data integrity. It provides a cost-effective solution for facilities requiring high-speed connectivity without a total system replacement.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2e86ab;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eTC-CCN014\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e24V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eNetwork Protocol\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCCN to Ethernet (TCP\/IP)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eTransfer Rate\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e10\/100 Mbps Auto-Sensing\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eTemp. Range\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e0°C to 60°C (Operation)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eApprox. 0.5 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2e86ab;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul style=\"color: #333; line-height: 1.8;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Modernization:\u003c\/strong\u003e Bridges the gap between legacy TC-CCN014 hardware and high-speed IT infrastructure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Operates reliably in EMI-heavy environments like mechanical rooms and data centers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Management:\u003c\/strong\u003e Enables remote climate control and automated alarm handling via central software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2e86ab;\"\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp style=\"color: #333; line-height: 1.6;\"\u003eMount the TC-CCN014 on a standard DIN rail and connect a stabilized 24V DC power source. For stable communication, assign a static IP address to the module during setup. Use shielded twisted-pair (STP) cabling for all CCN bus connections to prevent signal interference in proximity to high-power machinery.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2e86ab;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"color: #333;\"\u003e\u003cstrong\u003eQ1: How do I verify network connectivity?\u003c\/strong\u003e\u003cbr\u003e\nA1: Check the integrated LED indicators for Ethernet Link\/Activity. A steady light indicates a valid physical connection to the switch.\u003c\/p\u003e\n\n\u003cp style=\"color: #333;\"\u003e\u003cstrong\u003eQ2: Can it operate in high-humidity environments?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes, it handles up to 95% humidity, provided the environment remains non-condensing to prevent logic errors.\u003c\/p\u003e\n\n\u003cp style=\"color: #333;\"\u003e\u003cstrong\u003eQ3: Is the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003e\nA3: No. Power down the system before replacing the module to protect the internal circuitry and the CCN bus.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050820272260,"sku":"TC-CCN014","price":211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/TC-CCN014.jpg?v=1777961665","url":"https:\/\/www.etowonauto.com\/nb\/products\/honeywell-tc-ccn014-new-ccn-network-module","provider":"Etowon Auto","version":"1.0","type":"link"}