{"product_id":"honeywell-fc-psuni2424-600w-power-supply-sil3","title":"Honeywell FC-PSUNI2424 600W Power Supply SIL3","description":"\u003ch2\u003eIndustrial Power Supply for Safety Systems\u003c\/h2\u003e\n\u003cp\u003eHoneywell \u003cstrong\u003eFC-PSUNI2424\u003c\/strong\u003e delivers 600W for process and safety controllers. This \u003cstrong\u003ePSUNI2424\u003c\/strong\u003e supports SIL3 applications with dual over-voltage protection. \u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eSIL3 Protection:\u003c\/strong\u003e Dual over-voltage protection per IEC 61508.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eWide Range:\u003c\/strong\u003e 85-265VAC input, -40°C to 70°C operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eParallel Operation:\u003c\/strong\u003e Connect up to eight units for higher current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003ePeak Current:\u003c\/strong\u003e 50A for 200ms clears branch fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eInrush Limiting:\u003c\/strong\u003e \u0026lt;60A supports 10A type C breakers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eHot Swap:\u003c\/strong\u003e ON\/OFF switch enables online replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eFAN Alarm:\u003c\/strong\u003e Reduced speed monitoring minimizes wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eHold-Up Time:\u003c\/strong\u003e \u0026gt;50ms meets EN61000-4-11 level 3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eModel:\u003c\/strong\u003e Honeywell \u003cstrong\u003eFC-PSUNI2424\u003c\/strong\u003e (PSUNI2424).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eOutput Power:\u003c\/strong\u003e 600W continuous, 24V at 0-24A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eEfficiency:\u003c\/strong\u003e 87% typical at 230VAC, 12-24A load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003ePower Factor:\u003c\/strong\u003e \u0026gt;0.99 at 100VAC, \u0026gt;0.98 at 230VAC\/24A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eApprovals:\u003c\/strong\u003e CE, cUL, SIL3 OVP, CID2 pending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #cc0000;\"\u003eWeight:\u003c\/strong\u003e 2.9 kg (6.4 lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInput Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 85-265VAC operational, 45-66Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 6.2A at 115VAC, 3.1A at 230VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e \u0026lt;60A, supports 10A type C MCB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Fusing:\u003c\/strong\u003e 10A fuse per AC leg line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI Filter:\u003c\/strong\u003e 2uF between input lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOutput Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 25.7V no load, 25.1V at 24A static load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 0-24A continuous, 50A peak for 200ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limiter:\u003c\/strong\u003e 34A typical (27-42A) after 200ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple \u0026amp; Noise:\u003c\/strong\u003e 20-40mV ripple, HART compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit:\u003c\/strong\u003e Trips within 1 second at 0.5A, self-restoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Sharing:\u003c\/strong\u003e \u0026lt;10% difference at full load between units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAlarm Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Solid-state Opto-FET output, isolated to 500VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActivation:\u003c\/strong\u003e OK when FAN speed normal and output \u0026gt;23.5V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnder-Voltage Alarms:\u003c\/strong\u003e DC \u0026lt;23.5V, AC \u0026lt;80V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 31V (33V TVS protected).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 40mA max, non-inductive load only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e \u0026lt;0.2V at 7mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIsolation Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput to Output:\u003c\/strong\u003e 3750VAC\/1min, 8mm creepage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput to Case:\u003c\/strong\u003e 2210VAC\/1min with transient protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput to Case:\u003c\/strong\u003e 1500VDC\/1min, \u0026lt;50M Ohm at 250VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Dimensions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 370 mm (14.6 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 159 mm (6.3 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 67.3 mm (2.65 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.9 kg (6.4 lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -40°C to 70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temp:\u003c\/strong\u003e -40°C to 85°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 0-2000m above sea level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e PD2 maximum (IEC60664-1).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I parallel \u003cstrong\u003ePSUNI2424\u003c\/strong\u003e units for redundancy?\u003c\/strong\u003e \u003cbr\u003eA: Yes. Connect up to eight units in parallel. Load sharing maintains \u0026lt;10% difference at full load. This supports both redundancy and higher current applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What causes the alarm output to activate?\u003c\/strong\u003e \u003cbr\u003eA: Alarm activates when power supply status is OK. This requires FAN speed normal and output voltage above 23.5V. Under-voltage below these thresholds triggers alarm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does \u003cstrong\u003eFC-PSUNI2424\u003c\/strong\u003e support HART communication devices?\u003c\/strong\u003e \u003cbr\u003eA: Yes. Output ripple is 20-40mV typical, which meets HART requirements. Clean power ensures reliable communication with HART field devices.\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050803921028,"sku":"FC-PSUNI2424","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-PSUNI2424.jpg?v=1772884398","url":"https:\/\/www.etowonauto.com\/nb\/products\/honeywell-fc-psuni2424-600w-power-supply-sil3","provider":"Etowon Auto","version":"1.0","type":"link"}