{"product_id":"honeywell-cc-tdil11-24vdc-input-module","title":"Honeywell CC-TDIL11 24VDC Input Module","description":"\u003ch2\u003eHoneywell CC-TDIL11: Redundant 24V Digital Input IOTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TDIL11\u003c\/strong\u003e provides redundant termination for digital input signals in critical applications. This IOTA (Input\/Output Termination Assembly) connects field wiring to Series C redundant systems. \u003c\/p\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eBrand:\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eModel:\u003c\/span\u003e CC-TDIL11\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eType:\u003c\/span\u003e Digital Input IOTA Redundant\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eVoltage:\u003c\/span\u003e 24 VDC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCurrent Draw:\u003c\/span\u003e 0.190 Amps at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eHeat Dissipation:\u003c\/span\u003e 4.220 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIsolation:\u003c\/span\u003e 1500V field to logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRedundancy Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eArchitecture:\u003c\/span\u003e Dual redundant input paths\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eSwitchover:\u003c\/span\u003e Automatic bumpless transfer\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMonitoring:\u003c\/span\u003e Continuous path health check\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIndicators:\u003c\/span\u003e Per-path status LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCompatibility:\u003c\/span\u003e Works with redundant processor pairs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWeight:\u003c\/span\u003e 1.2kg (2.65 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eDimensions:\u003c\/span\u003e 180mm x 130mm x 60mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTerminals:\u003c\/span\u003e Screw clamp type, 12-22 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMaterial:\u003c\/span\u003e Steel chassis with enamel coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMounting:\u003c\/span\u003e Direct to subpanel or DIN rail adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eConnectors:\u003c\/span\u003e Dual 50-pin to module cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTemperature:\u003c\/span\u003e -40°C to +70°C operating\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eStorage:\u003c\/span\u003e -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eHumidity:\u003c\/span\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eVibration:\u003c\/span\u003e 1mm displacement 10-55Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCorrosion:\u003c\/span\u003e Coated for harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eProtection:\u003c\/span\u003e IP20 finger-safe terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the 0.190A current draw represent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This is the IOTA's own power consumption from the backplane. Field devices draw separate power from your external 24V supply connected to the IOTA terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the redundancy actually work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003eCC-TDIL11\u003c\/strong\u003e splits each field input to two separate input modules. If one module fails, the second continues reading the signal with zero interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why 4.220 Watts heat dissipation matter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This helps you calculate cabinet cooling needs. The \u003cstrong\u003eCC-TDIL11\u003c\/strong\u003e generates 4.22W continuously. Factor this into your panel ventilation design.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573169979524,"sku":"CC-TDIL11","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TDIL11-2.jpg?v=1772352690","url":"https:\/\/www.etowonauto.com\/nb\/products\/honeywell-cc-tdil11-24vdc-input-module","provider":"Etowon Auto","version":"1.0","type":"link"}