{"product_id":"honeywell-cc-paih02-hart-analog-input-module-16-channel","title":"Honeywell CC-PAIH02 HART Analog Input Module | 16-Channel","description":"\u003ch2\u003eHoneywell CC-PAIH02 HART Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIH02\u003c\/strong\u003e provides \u003cstrong style=\"color: #2e86ab;\"\u003ehigh-precision 16-channel analog input\u003c\/strong\u003e with HART protocol support. This versatile module offers \u003cstrong\u003eflexible signal acceptance\u003c\/strong\u003e and \u003cstrong\u003eexceptional noise immunity\u003c\/strong\u003e for accurate process monitoring in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eManufacturer:\u003c\/strong\u003e Honeywell International\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eModel Number:\u003c\/strong\u003e CC-PAIH02 HART Analog Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eInput Configuration:\u003c\/strong\u003e 16 total channels (12 single-ended, 4 differential)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eSignal Types:\u003c\/strong\u003e 4-20mA, 1-5V, 0-5V, 0.4-2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eADC Resolution:\u003c\/strong\u003e 16-bit high precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;10 MΩ for voltage inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003ePower Consumption:\u003c\/strong\u003e 60W maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eScan Rate:\u003c\/strong\u003e 50ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eHardware Accuracy:\u003c\/strong\u003e ±0.075% FS at 23.5°C ±2°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eTemperature Accuracy:\u003c\/strong\u003e ±0.15% FS from 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCommon Mode Rejection:\u003c\/strong\u003e 70dB (DC to 60Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eNormal Mode Rejection:\u003c\/strong\u003e 19dB at 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eChannel Crosstalk:\u003c\/strong\u003e -60dB isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eInput Protection:\u003c\/strong\u003e ±30V maximum without damage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eCommon Mode Voltage:\u003c\/strong\u003e -6V to +5V peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eFilter Response:\u003c\/strong\u003e Single-pole RC, -3dB @ 6.5Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 19-inch rack mounting\u003c\/li\u003e\n\u003cli\u003e22-28VDC power supply required\u003c\/li\u003e\n\u003cli\u003eShielded twisted pair wiring recommended\u003c\/li\u003e\n\u003cli\u003eProper grounding for noise reduction\u003c\/li\u003e\n\u003cli\u003e250Ω resistor for current input configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Experion PKS control systems\u003c\/li\u003e\n\u003cli\u003eSeries C I\/O architecture platforms\u003c\/li\u003e\n\u003cli\u003eHART protocol compatible field devices\u003c\/li\u003e\n\u003cli\u003eIndustrial Ethernet communication networks\u003c\/li\u003e\n\u003cli\u003eThird-party DCS with appropriate gateways\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed for general safety\u003c\/li\u003e\n\u003cli\u003eCE Marked for European compliance\u003c\/li\u003e\n\u003cli\u003eClass 1 Division 2 non-incendive rating\u003c\/li\u003e\n\u003cli\u003eATEX certified for hazardous areas\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2 standards compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat input signals does the CC-PAIH02 support?\u003c\/strong\u003e\u003cbr\u003eThe module accepts 4-20mA, 1-5V, 0-5V, and 0.4-2V signals with flexible configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eHow many channels are available and in what configuration?\u003c\/strong\u003e\u003cbr\u003e16 total channels with 12 single-ended and 4 differential inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e86ab;\"\u003eWhat safety certifications does this module have?\u003c\/strong\u003e\u003cbr\u003eIt carries Class 1 Division 2 non-incendive rating for hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050819190916,"sku":"CC-PAIH02","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-PAIH02.jpg?v=1761656517","url":"https:\/\/www.etowonauto.com\/nb\/products\/honeywell-cc-paih02-hart-analog-input-module-16-channel","provider":"Etowon Auto","version":"1.0","type":"link"}