{"product_id":"hima-f3330-output-module-safety-related-8-fold-ak1-6","title":"HIMA F3330 Output Module Safety Related 8 Fold AK1-6","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eF3330\u003c\/strong\u003e (also designated as \u003cstrong\u003eF 3330\u003c\/strong\u003e) is an 8-fold safety-related digital output module manufactured by HIMA for high-integrity safety systems up to Requirement Class AK 1...6. It provides eight short-circuit-proof outputs capable of driving resistive or inductive loads up to 500 mA (12 W) and lamp loads up to 4 W. Featuring integrated safety shutdown, safe electrical isolation, and undervoltage tripping at ≤ 16 V, the F3330 prevents output signals upon L- supply breakage. Occupying 4 TE width and weighing 0.45 kg, it delivers reliable field actuation in SIL-rated control panels.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Safety Integrity (AK 1...6):\u003c\/strong\u003e Designed for critical safety applications requiring safe isolation and integrated safety shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Circuit Proof Outputs:\u003c\/strong\u003e 8 output channels feature built-in short-circuit protection for loads up to 500 mA (12 W).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Voltage Protection:\u003c\/strong\u003e Features automated undervoltage tripping at ≤ 16 V and output cutoff on L- supply failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eHIMA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eF3330 (F 3330)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8-Fold Output Module (Safety Related)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eRequirement Class Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAK 1 ... 6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Capacity per Channel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e500 mA (12 W) Resistive\/Inductive; 4 W Lamp Load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eShort-Circuit Proof (k)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMax Internal Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2 V at 500 mA load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eAdmissible Line Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMax. 11 Ohm (In + Out)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eUndervoltage Tripping\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAt ≤ 16 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating Power Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5 V DC = 110 mA \/ 24 V DC = 180 mA (plus load current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIntegrated safety shutdown, safe isolation, zero signal on L- break\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eSpace Requirement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4 TE (Width)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.45 kg (450 g)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmergency Shutdown (ESD) Systems:\u003c\/strong\u003e Actuates safety solenoids and trip valves in critical process plants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurner Management Systems (BMS):\u003c\/strong\u003e Drives fuel safety shut-off valves requiring AK1-6 compliance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Signal Annunciation:\u003c\/strong\u003e Controls pilot lamps and alarm relays with integrated short-circuit isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Mount the 4 TE module into the designated HIMA subrack slot until fully seated.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Resistance Check:\u003c\/strong\u003e Verify that combined supply and return wire resistance does not exceed 11 Ohms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Load Wiring:\u003c\/strong\u003e Wire 24 V DC actuators or indicators to output terminals observing polarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Internal Losses:\u003c\/strong\u003e Maximum 2 V voltage drop at full 500 mA load minimizes thermal dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Enclosure:\u003c\/strong\u003e Requires only 4 TE of rack width to save cabinet backplane space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFail-Safe Architecture:\u003c\/strong\u003e Guarantees output drop-out when L- supply is interrupted or voltage falls below 16 V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What load ratings does each output channel of the HIMA F3330 support?\u003c\/strong\u003e\u003cbr\u003e\nA1: Channels support 500 mA (12 W) resistive\/inductive loads or up to 4 W lamp loads.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: At what voltage level does undervoltage tripping occur on the F3330?\u003c\/strong\u003e\u003cbr\u003e\nA2: The module trips and shuts down outputs when supply voltage drops to ≤ 16 V.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum line resistance permitted for field wiring?\u003c\/strong\u003e\u003cbr\u003e\nA3: Total admissible line resistance (in + out combined) is maximum 11 Ohms.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52897196802180,"sku":"F3330","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F3330_2.jpg?v=1790415318","url":"https:\/\/www.etowonauto.com\/nb\/products\/hima-f3330-output-module-safety-related-8-fold-ak1-6","provider":"Etowon Auto","version":"1.0","type":"link"}