{"product_id":"ge-fanuc-ic697mem713-128kb-ram-256kb-flash-module","title":"GE Fanuc IC697MEM713 128KB RAM 256KB Flash Module","description":"\u003ch2 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc \u003cstrong style=\"color: #e53935;\"\u003eIC697MEM713\u003c\/strong\u003e is a high-reliability memory expansion module designed specifically for the Series 90-70 PLC system. This module provides essential volatile and non-volatile storage to support complex logic execution and data logging in large-scale industrial automation environments. \u003c\/p\u003e\n\u003ch2 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #e53935;\"\u003eIC697MEM713\u003c\/strong\u003e is engineered for precision and longevity within the GE Fanuc ecosystem, offering several hardware-level benefits:\u003c\/p\u003e\n\u003ch3 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eHybrid Storage Architecture\u003c\/h3\u003e\n\u003cp\u003eThis module features a dual-memory design: 128 KB of high-speed CMOS RAM for active logic processing and 256 KB of Flash memory for permanent storage of the operating system and user programs. This configuration allows for rapid data access while providing a robust backup for system configuration.\u003c\/p\u003e\n\u003ch3 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eIndustrial Standard Communication\u003c\/h3\u003e\n\u003cp\u003eEquipped with two RS-422\/RS-485 ports and a dedicated RS-232 interface, the module facilitates seamless data throughput at rates up to 115.2 kbps. This multi-port setup supports simultaneous programming, HMI connectivity, and peripheral communication.\u003c\/p\u003e\n\u003ch3 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eEnhanced Thermal Resilience\u003c\/h3\u003e\n\u003cp\u003eUnlike standard consumer-grade electronics, the IC697MEM713 maintains full functionality across an extended temperature range of -20°C to +70°C. This resilience makes it suitable for unconditioned control cabinets in harsh industrial settings.\u003c\/p\u003e\n\u003ch2 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ddd; font-family: Arial, sans-serif;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e128 KB RAM \/ 256 KB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eCPU Clock Speed\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e16 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e2x RS-422\/485, 1x RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e1.0 A @ 5 V (5W Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eMTBF\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e100,000 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e3 Diagnostic LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eEngineering Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003eProper integration of the IC697MEM713 ensures maximum system uptime. Consider the following professional recommendations:\u003c\/p\u003e\n\u003ch3 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eModule Insertion\u003c\/h3\u003e\n\u003cp\u003eAlways power down the PLC rack before inserting or removing the memory module. Ensure the module is seated firmly in the Series 90-70 backplane to prevent intermittent communication errors caused by poor pin contact.\u003c\/p\u003e\n\u003ch3 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eBattery Backup\u003c\/h3\u003e\n\u003cp\u003eWhile the Flash memory is non-volatile, the 128 KB RAM requires a functional system battery to retain data during power outages. Check the PLC battery status LED periodically to ensure the volatile logic data is protected.\u003c\/p\u003e\n\u003ch3 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eDiagnostic Monitoring\u003c\/h3\u003e\n\u003cp\u003eUtilize the three onboard LEDs for immediate troubleshooting. These indicators provide real-time feedback on memory access, communication status, and module health, allowing maintenance teams to identify faults without external tools.\u003c\/p\u003e\n\u003ch2 style=\"color: #1565c0; font-family: Arial, sans-serif;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the IC697MEM713 compatible with Series 90-30 CPUs?\u003c\/strong\u003e\u003cbr\u003eA1: No. This module is specifically designed for the Series 90-70 architecture. For Series 90-30 systems, please use the IC693 series memory components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I upgrade the Flash capacity on this specific module?\u003c\/strong\u003e\u003cbr\u003eA2: The 256 KB Flash is factory-integrated and cannot be physically upgraded. If more storage is required, a different model in the IC697MEM family must be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the module support remote programming?\u003c\/strong\u003e\u003cbr\u003eA3: Yes. Using the RS-232 or RS-422\/485 ports, you can interface with Logicmaster 90 or Proficy Machine Edition for remote configuration and diagnostic uploads.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050833215620,"sku":"IC697MEM713","price":285.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697MEM713.jpg?v=1776523492","url":"https:\/\/www.etowonauto.com\/nb\/products\/ge-fanuc-ic697mem713-128kb-ram-256kb-flash-module","provider":"Etowon Auto","version":"1.0","type":"link"}