{"product_id":"ge-fanuc-ic694mdl260-high-density-32-inputs","title":"GE Fanuc IC694MDL260 High-Density 32 Inputs","description":"\u003ch2\u003eGE Fanuc IC694MDL260 32-Point High-Density Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL260\u003c\/strong\u003e is a 32-point discrete input module for PACSystem RX3i. Formerly by GE Fanuc, now Emerson Automation, it features 32 channels in 4 isolated groups of 8. This high-density module accepts 120 Volts AC nominal and supports positive logic wiring.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL260\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystem RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Points:\u003c\/strong\u003e 32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroups:\u003c\/strong\u003e 4 isolated groups of 8 channels each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 120 Volts AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 0-132 VAC (47-63 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e 70-132 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e 0-20 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 7 mA per channel at rated voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current:\u003c\/strong\u003e 6 mA minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Current:\u003c\/strong\u003e 2.5 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 220 mA from 5 VDC backplane bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter Time:\u003c\/strong\u003e 20-2540 ms in 20 ms increments (CPU configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Up to 840 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Isolation:\u003c\/strong\u003e 264 VAC continuous, 1500 VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Isolation:\u003c\/strong\u003e 264\/1500 Volts AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Terminal block presence detected and reported to RX3i CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard or expansion base with terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Series 90-30 PLC devices, RX3i PacSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0-50 degrees Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIP Switch:\u003c\/strong\u003e Rear-mounted for input filter time adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Lifecycle:\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eIC694MDL260\u003c\/strong\u003e discrete input module\u003c\/li\u003e\n\u003cli\u003eTerminal block sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow are the 32 inputs organized on the IC694MDL260?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL260\u003c\/strong\u003e has 4 isolated groups with 8 channels per group. Each group uses a common reference.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat happens if one group's common reference fails?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnly that specific group becomes unusable. The other three groups continue operating normally.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan I adjust input filter time during operation?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes, the controller can modify filter time via assigned memory. New setting equals time value divided by 20.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51047938326660,"sku":"IC694MDL260","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL260.jpg?v=1772288847","url":"https:\/\/www.etowonauto.com\/nb\/products\/ge-fanuc-ic694mdl260-high-density-32-inputs","provider":"Etowon Auto","version":"1.0","type":"link"}