{"product_id":"ge-fanuc-ic693pbs201-profibus-dp-slave-module-series-90-30-plc","title":"GE Fanuc IC693PBS201 Profibus DP Slave Module Series 90-30 PLC","description":"\u003csection\u003e\n  \u003ch2\u003eProduct Overview\u003c\/h2\u003e\n  \u003cp\u003eThe \u003cstrong style=\"color: #c0392b; font-size: 1.15em;\"\u003eGE Fanuc IC693PBS201\u003c\/strong\u003e is a high-performance Profibus DP Slave Module designed to provide seamless connectivity for the Series 90-30 PLC system within a Profibus network. This module allows a Series 90-30 PLC to function as a slave device on a Profibus DP network, enabling the exchange of high-speed cyclic I\/O data with a Profibus DP Master. The \u003cstrong style=\"color: #c0392b;\"\u003eIC693PBS201\u003c\/strong\u003e is an essential interface for integrating GE Fanuc automation systems into multi-vendor industrial networks.\u003c\/p\u003e\n\n  \u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n  \u003cp\u003eAdvanced communication architecture for Series 90-30 networked systems:\u003c\/p\u003e\n  \u003cul style=\"line-height: 1.8;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc \/ Emerson\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC693PBS201\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNetwork Role:\u003c\/strong\u003e Profibus DP Slave\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInterface Port A:\u003c\/strong\u003e RS-232 Service Port (9-pin D-shell)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInterface Port B:\u003c\/strong\u003e Profibus DP Slave Port (9-pin D-shell)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBackplane Current Draw:\u003c\/strong\u003e 450 mA @ 5 VDC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eData Capacity:\u003c\/strong\u003e 244 Bytes of Input and 244 Bytes of Output data\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMax Baud Rate:\u003c\/strong\u003e Supports up to 12 Mbps with auto-detection\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; border: 1px solid #e0e0e0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 12px; border: 1px solid #e0e0e0; text-align: left;\"\u003eRequirement\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; border: 1px solid #e0e0e0; text-align: left;\"\u003eDetailed Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e\u003cstrong\u003eApproximately 0.45 kg\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e\u003cstrong\u003eSupported Baud Rates\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e9.6 kbps to 12 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e\u003cstrong\u003eMax Distance (Copper)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e1,200 meters (at 9.6 kbps)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e\u003cstrong\u003eMax Distance (Fiber)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003eUp to 6 km (with optical link modules)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e\u003cstrong\u003eSoftware Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003eProficy Machine Edition ≥ v2.6\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n  \u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693PBS201\u003c\/strong\u003e provides a flexible communication solution, supporting a wide array of baud rates from \u003cstrong\u003e9.6 kbps up to 12 Mbps\u003c\/strong\u003e, ensuring compatibility with various network speeds. It is designed for easy installation, fitting into \u003cstrong\u003eany single slot\u003c\/strong\u003e of a Series 90-30 baseplate (excluding slot 1). The module features a dedicated \u003cstrong\u003eRS-232 service port\u003c\/strong\u003e for firmware updates and local diagnostics, keeping the primary Profibus port free for network traffic. With a high data capacity of \u003cstrong\u003e244 bytes for both inputs and outputs\u003c\/strong\u003e, it can handle complex data exchange requirements for sophisticated automation tasks.\u003c\/p\u003e\n\n  \u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n  \u003cp\u003e\u003cstrong\u003eQ1: Which PLC slot can I use for the IC693PBS201?\u003c\/strong\u003e\u003cbr\u003e\n  A1: This module can be installed in any available I\/O slot in a Series 90-30 baseplate, expansion baseplate, or remote baseplate, except for Slot 1, which is reserved for the CPU or a Power Supply in certain configurations.\u003c\/p\u003e\n  \n  \u003cp\u003e\u003cstrong\u003eQ2: What firmware version is required for the PLC CPU?\u003c\/strong\u003e\u003cbr\u003e\n  A2: To ensure full compatibility and functionality of the IC693PBS201, your Series 90-30 CPU should be running firmware version 8.00 or higher.\u003c\/p\u003e\n  \n  \u003cp\u003e\u003cstrong\u003eQ3: Does this module support Profibus DP Master functionality?\u003c\/strong\u003e\u003cbr\u003e\n  A3: No, the IC693PBS201 is strictly a Slave module. For Master functionality, a different module, such as the IC693PBM200, would be required.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050829152388,"sku":"IC693PBS201","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693PBS201.jpg?v=1779286921","url":"https:\/\/www.etowonauto.com\/nb\/products\/ge-fanuc-ic693pbs201-profibus-dp-slave-module-series-90-30-plc","provider":"Etowon Auto","version":"1.0","type":"link"}