{"product_id":"epro-pr9268-205-000-eddy-current-probe","title":"EPRO PR9268\/205-000 Eddy Current Probe","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a237e;\"\u003ePR9268\/205-000\u003c\/strong\u003e is a rugged, non-contact eddy current sensor designed for critical displacement and vibration monitoring. Optimized for turbines and compressors, its reverse-mount design allows for effortless installation from the exterior of the machine housing. By delivering high-fidelity signal stability without mechanical wear, it serves as a primary defense for large-scale rotating assets in extreme industrial environments.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThis unit features a specialized reverse-mount body and an integrated 5-meter low-noise cable. The hardware is calibrated for seamless integration with EPRO MMS monitoring systems, ensuring a linear sensitivity of 8 V\/mm. Its robust construction eliminates the need for complex field adjustments, providing a reliable plug-and-play solution for high-temperature shaft monitoring.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eLinear Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSensitivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8 V\/mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSupply Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOutput Signal\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-2 to -18 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0 to 3000 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOperating Temp\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-20 to 120 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 id=\"installation-maintenance-guide\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eTo install the \u003cstrong\u003ePR9268\/205-000\u003c\/strong\u003e, secure the probe into the reverse-mount port and adjust the gap until the output voltage reaches approximately -10 VDC. This ensures the sensor operates at the center of its linear range. Always verify that the target shaft surface is clean and free of magnetic interference. Keep the 5-meter cable away from high-voltage lines to prevent EMI signal noise.\u003c\/p\u003e\n\n\u003ch2 id=\"engineering-advantages\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003ePR9268\/205-000\u003c\/strong\u003e excels in durability, maintaining precision across a wide temperature spectrum. The reverse-mount architecture is a significant time-saver, allowing maintenance teams to service the probe without opening bearing pedestals. Its high frequency response makes it equally effective for detecting both slow-roll eccentricity and high-speed blade passing frequencies.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What does a -24V output indicate?\u003cbr\u003e\nA1: A constant -24V signal usually indicates an \"open circuit\" or that the probe tip is too far from the target surface to detect a signal.\u003c\/p\u003e\n\u003cp\u003eQ2: Is the cable length customizable?\u003cbr\u003e\nA2: No. The electronics are factory-tuned to the specific 5-meter cable impedance. Shortening the cable will compromise the measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ3: Does it support third-party PLCs?\u003cbr\u003e\nA3: Yes, as long as the PLC analog input can process a -2 to -18 VDC signal, this sensor can integrate with most standard industrial controllers.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51050854121604,"sku":"PR9268\/205-000","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/PR9268_205-000.jpg?v=1777883977","url":"https:\/\/www.etowonauto.com\/nb\/products\/epro-pr9268-205-000-eddy-current-probe","provider":"Etowon Auto","version":"1.0","type":"link"}