{"product_id":"emerson-a6500-um-universal-measurement-card-for-machinery-monitoring","title":"Emerson A6500-UM Universal Measurement Card for Machinery Monitoring","description":"\u003ch2\u003e\u003cstrong\u003eEmerson A6500-UM Universal Measurement Card\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eA6500-UM\u003c\/strong\u003e from Emerson is a versatile dual-channel measurement module for the \u003cstrong\u003eAMS 6500\u003c\/strong\u003e machinery protection system. This single-slot card accepts multiple sensor types for comprehensive machine monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompact Design and Key Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e67e22;\"\u003e\u003cstrong\u003eTwo-channel 3U module\u003c\/strong\u003e\u003c\/span\u003e saves 50% cabinet space versus traditional 6U cards.\u003c\/li\u003e\n\u003cli\u003eFully compliant with \u003cstrong\u003eAPI 670\u003c\/strong\u003e machinery protection standards.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cspan style=\"color: #e67e22;\"\u003e\u003cstrong\u003ehot-swappable\u003c\/strong\u003e\u003c\/span\u003e design for easy maintenance without system downtime.\u003c\/li\u003e\n\u003cli\u003eSupports remote selection of limit multiply and trip bypass functions.\u003c\/li\u003e\n\u003cli\u003eIncludes 5 digital inputs and 6 digital outputs for flexible system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMulti-Sensor Input Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Emerson \u003cstrong\u003eA6500-UM\u003c\/strong\u003e Universal Measurement Card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Sensors:\u003c\/strong\u003e Eddy-current, piezoelectric (accel\/velometer), seismic, LF vibration, Hall-effect, LVDT, and dynamic pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy Current Input:\u003c\/strong\u003e -1 to -22 V, 0-18,750 Hz, -23.25\/-26.0 VDC supply, ±1% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiezoelectric Input:\u003c\/strong\u003e +1 to +23 V, 0-18,750 Hz, 0-8 mA constant current supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeismic Input:\u003c\/strong\u003e -10 to +15 V, 0-2,000 Hz, 0-8 mA lifting current supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLF Vibration Input:\u003c\/strong\u003e -11 to +11 V, 0-1,000 Hz, ±15 VDC supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Functions and Outputs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Modes:\u003c\/strong\u003e Shaft vibration, case vibration, position, speed\/key, dynamic pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Outputs:\u003c\/strong\u003e Two 0\/4-20 mA channels, ±1% accuracy, load \u0026lt;500 Ω.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e Six solid-state relays (normally open), 19-32 VDC, 100 mA max load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Outputs:\u003c\/strong\u003e Two opto-decoupled outputs, 0-2,000 Hz, 30 mA max load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRaw Signal Outputs:\u003c\/strong\u003e One per sensor input, non-reactive, ±1% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Internal RS-485 to Modbus RTU\/TCP via A6500-CC Com Card.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 70°C (-4°F to 158°F) with cooling; -20°C to 55°C (-4°F to 131°F) without.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to 185°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH, non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e IEC 60068-2-6 (0.15mm at 10-55 Hz, 20m\/s² at 55-150 Hz).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC, maximum 6W consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 3RU height, 6HP width, 100 x 160mm PCB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 200g (0.44 lbs) excluding packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Safety Approvals\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standard:\u003c\/strong\u003e IEC 61010-1 compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e ATEX\/IECEx II 3G Ex nA nC IIC Gc, T4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth America:\u003c\/strong\u003e CSA Class I Div 2, Groups A,B,C,D; UL 61010-1 listed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational:\u003c\/strong\u003e CE, EAC, CCC, CCOE PESO India, and DNV GL marine certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integrity:\u003c\/strong\u003e SC 2 (SIL 2 Capable) per IEC 61508.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What types of measurements can the A6500-UM card perform?\u003c\/strong\u003e\u003cbr\u003eA: It performs shaft vibration, case vibration (displacement\/velocity\/acceleration), position (distance, rod drop, eccentricity), speed\/key, and dynamic pressure measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What communication protocols does this card support?\u003c\/strong\u003e\u003cbr\u003eA: It communicates via internal RS-485 bus to the A6500-CC Com Card, which provides Modbus RTU and Modbus TCP\/IP outputs for connection to control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this card suitable for use in hazardous areas?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it carries multiple hazardous area certifications including ATEX, IECEx, CSA, and CCC-Ex for use in Class I Division 2\/Zone 2 areas with appropriate installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51047924105348,"sku":"A6500-UM","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/A6500-UM.jpg?v=1767319872","url":"https:\/\/www.etowonauto.com\/nb\/products\/emerson-a6500-um-universal-measurement-card-for-machinery-monitoring","provider":"Etowon Auto","version":"1.0","type":"link"}