{"product_id":"bachmann-model-ti214-precision-temperature-measurement-module","title":"Bachmann Model TI214 Precision Temperature Measurement Module","description":"\u003ch2\u003e\u003cstrong\u003eBachmann TI214 Temperature Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann \u003cstrong\u003eTI214\u003c\/strong\u003e is a high-precision temperature input module. It is designed for industrial measurement and control systems. This module supports multiple sensor types. It connects Pt100 and Pt1000 RTDs and J\/K thermocouples. The TI214 delivers high accuracy and reliable data. It is built for demanding automation environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Sensor Support:\u003c\/strong\u003e Works with Pt100, Pt1000 RTDs and Type J, K thermocouples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Measurement Accuracy:\u003c\/strong\u003e 0.1% accuracy for RTDs, 0.15% for thermocouples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e Measures from -100°C to +1000°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Built-in wire break detection for sensor health monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Signal Conditioning:\u003c\/strong\u003e Includes filtering and high interference voltage tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bachmann\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003eTI214\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Temperature Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 14 independent temperature inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Sensors:\u003c\/strong\u003e Pt100, Pt1000 (2-wire or 3-wire); Type J, K Thermocouples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Measurement Range:\u003c\/strong\u003e -100°C to +800°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple Range:\u003c\/strong\u003e -30°C to +1000°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Excitation Current:\u003c\/strong\u003e 2 mA for Pt100, 200 µA for Pt1000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Accuracy:\u003c\/strong\u003e ±0.1% for RTDs; ±0.15% for T\/Cs (at +25°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Resolution:\u003c\/strong\u003e 14-bit (effective 16-bit with averaging)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeast Significant Bit (LSB):\u003c\/strong\u003e 0.055 K (RTD), 0.062 K (Thermocouple)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion Time:\u003c\/strong\u003e 80 ms (16-fold avg), 320 ms (64-fold avg) - configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter:\u003c\/strong\u003e 1st-order low-pass, 17 kHz cutoff frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearization:\u003c\/strong\u003e Polynomial per IEC 60584-1 for thermocouples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference Voltage Tolerance:\u003c\/strong\u003e -36V to +36V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Wire break detection on all channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel-to-channel and channel-to-system isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC (via system backplane)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Typically 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Standard Bachmann M1 module size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 0.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module into a compatible Bachmann M1 I\/O base unit.\u003c\/li\u003e\n\u003cli\u003eConnect sensors using the correct 2-wire or 3-wire scheme for RTDs.\u003c\/li\u003e\n\u003cli\u003eEnsure proper thermocouple polarity and use compensating cable if needed.\u003c\/li\u003e\n\u003cli\u003eConfigure each channel for the correct sensor type via software.\u003c\/li\u003e\n\u003cli\u003eSet the desired averaging factor (conversion time) based on application needs.\u003c\/li\u003e\n\u003cli\u003eEnable wire break detection for critical monitoring points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-point temperature monitoring in process industries.\u003c\/li\u003e\n\u003cli\u003eMachine and equipment thermal protection systems.\u003c\/li\u003e\n\u003cli\u003eEnvironmental chamber and HVAC system control.\u003c\/li\u003e\n\u003cli\u003eEnergy generation plants (e.g., monitoring bearing or winding temperatures).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix different sensor types on one TI214 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: Yes. Each of the 14 channels can be independently configured for either RTD (Pt100\/Pt1000) or Thermocouple (Type J\/K) input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the configurable conversion time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA\u0026gt; A longer conversion time with higher averaging (64-fold) provides a more stable, noise-filtered reading for slow processes. A faster time (16-fold) is better for tracking rapid temperature changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it require cold junction compensation for thermocouples?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: Yes. The module performs automatic cold junction compensation using an internal temperature sensor at its terminal block to ensure thermocouple measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":51050733305988,"sku":"TI214","price":155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/TI214-1.jpg?v=1768613280","url":"https:\/\/www.etowonauto.com\/nb\/products\/bachmann-model-ti214-precision-temperature-measurement-module","provider":"Etowon Auto","version":"1.0","type":"link"}