{"product_id":"allen-bradley-80190-540-02-r-temperature-transmitter-module","title":"Allen-Bradley 80190-540-02-R Temperature Transmitter Module","description":"\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e80190-540-02-R\u003c\/strong\u003e is a high-precision temperature signal processing module designed for rugged industrial automation environments. This board serves as a critical interface that converts thermocouple-compatible input signals into a standardized \u003cstrong\u003e4-20 mA analog output\u003c\/strong\u003e, ensuring seamless integration with PLCs and DCS systems. With a robust design supporting wide operating temperatures and high isolation voltage, it provides stable and accurate temperature monitoring for critical machinery and process control loops.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n    \u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e80190-540-02-R\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupply Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e24V DC ± 10%\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eInput Signal Range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e-10°C to +100°C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOutput Signal Type\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e4-20 mA (Analog)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIsolation Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e500V AC (Input to Output)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eResponse Time\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1 Second (Typical)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e-40°C to +85°C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBoard Dimensions\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e120 mm x 100 mm x 15 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e200 grams (0.44 lbs)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3 style=\"color: #333;\"\u003eExceptional Thermal Stability\u003c\/h3\u003e\n\u003cp\u003eThe 80190-540-02-R is engineered to operate in extreme environments, maintaining precision from \u003cstrong\u003e-40°C up to +85°C\u003c\/strong\u003e. This makes it an ideal choice for outdoor enclosures or unconditioned industrial facilities where temperature fluctuations are common.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eEnhanced Signal Protection\u003c\/h3\u003e\n\u003cp\u003eFeaturing an \u003cstrong\u003eisolation voltage of 500V AC\u003c\/strong\u003e between the input and output stages, this board protects sensitive control logic from field-side electrical noise and ground loops. This internal barrier ensures the integrity of your 4-20 mA data transmission over long distances.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eCompact and Lightweight Hardware\u003c\/h3\u003e\n\u003cp\u003eWeighing only \u003cstrong\u003e200 grams\u003c\/strong\u003e, this module offers a lightweight footprint that reduces the mechanical stress on mounting brackets and DIN rail assemblies. Its optimized 120mm x 100mm dimensions allow for high-density installation in compact control cabinets.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the board is mounted securely using the integrated mounting holes. Maintain adequate clearance around the board for heat dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Verify the polarity of the 24V DC supply before powering the module. Use shielded cabling for the thermocouple-compatible input to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e The 1-second response time is optimized for standard industrial temperature monitoring. For high-speed thermal transients, ensure the downstream PLC sampling rate is synchronized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the 80190-540-02-R compatible with standard K-type thermocouples?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes, the module is designed to be thermocouple compatible within the specified -10°C to +100°C range, converting the low-voltage millivolt signal into a stable 4-20 mA current loop.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can this board be used in outdoor applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: While the board is rated for -40°C, it should be installed within an IP-rated enclosure to protect the circuitry from moisture, dust, and direct environmental exposure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum current draw of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Under full load conditions, the 80190-540-02-R maintains a low power profile with a maximum current consumption of 50 mA at 24V DC.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050728554628,"sku":"80190-540-02-R","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/80190-540-02-R-1.jpg?v=1778406950","url":"https:\/\/www.etowonauto.com\/nb\/products\/allen-bradley-80190-540-02-r-temperature-transmitter-module","provider":"Etowon Auto","version":"1.0","type":"link"}