{"product_id":"abb-ypi103e-yt204001-fb-digital-i-o-module-16-inputs-8-relays","title":"ABB YPI103E YT204001-FB Digital I\/O Module 16 Inputs 8 Relays","description":"\u003ch2 style=\"color: #333333;\"\u003eABB YPI103E YT204001-FB Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eABB YPI103E YT204001-FB\u003c\/strong\u003e is a digital I\/O module with 16 digital input channels and 8 relay output channels. Operates on 24V DC with maximum 5W power consumption. Features Ethernet\/IP and Profibus communication protocols. Weight: 0.8 kg (1.76 lbs).\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eYPI103E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eYT204001-FB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eHS Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eMaximum 5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eInput Channels\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e16 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOutput Channels\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e8 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSignal Processing Speed\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e1 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eEthernet\/IP, Profibus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e-10°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOutput Load Capacity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eUp to 2 kg load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e16 × 16 × 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e0.8 kg (1.76 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital input channels for field device monitoring\u003c\/li\u003e\n\u003cli\u003e8 relay output channels for load control\u003c\/li\u003e\n\u003cli\u003eEthernet\/IP and Profibus communication protocols\u003c\/li\u003e\n\u003cli\u003eFast 1 ms per channel signal processing\u003c\/li\u003e\n\u003cli\u003e24V DC operation with 5W maximum power consumption\u003c\/li\u003e\n\u003cli\u003eOutputs support up to 2 kg load capacity\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range -10°C to +60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Install in control cabinet with adequate ventilation. Ensure proper grounding to panel earth. Maintain clearance for heat dissipation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect 24V DC supply to power terminals. Use 1.5 mm² minimum wire. Verify polarity before energizing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Setup:\u003c\/strong\u003e Configure Ethernet\/IP or Profibus network settings. Assign unique node address. Verify network termination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Wiring:\u003c\/strong\u003e Relay outputs support up to 2 kg load. Use external fusing for inductive loads. Follow local wiring codes.\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. What is the input and output channel count?\u003c\/strong\u003e\u003cbr\u003eA1. The module provides 16 digital input channels and 8 relay output channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. What communication protocols are supported?\u003c\/strong\u003e\u003cbr\u003eA2. The module supports Ethernet\/IP and Profibus communication protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. What is the signal processing speed?\u003c\/strong\u003e\u003cbr\u003eA3. The module processes signals at 1 ms per channel for fast response.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047936884868,"sku":"YPI103E","price":192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/YPI103E_ABB.jpg?v=1792333635","url":"https:\/\/www.etowonauto.com\/nb\/products\/abb-ypi103e-yt204001-fb-digital-i-o-module-16-inputs-8-relays","provider":"Etowon Auto","version":"1.0","type":"link"}