{"product_id":"22d-e4p2n104-3-phase-adjustable-frequency-drive-allen-bradley","title":"22D-E4P2N104 3-Phase Adjustable Frequency Drive Allen-Bradley","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e22D-E4P2N104\u003c\/strong\u003e is an industrial-grade, closed-loop capable Adjustable Frequency AC Drive from the Allen-Bradley PowerFlex 40P product family by Rockwell Automation. Explicitly engineered for demanding, space-conscious motor speed and torque regulation, this premium drive accepts a 3-phase incoming utility voltage of 600V AC (operating within an allowable range of 414 to 660V AC). It delivers a highly precise 4.2 Ampere continuous output rating, corresponding to a \u003cstrong style=\"color: #0056b3;\"\u003e2.2 kW (3 Horsepower)\u003c\/strong\u003e load capacity. Combining Sensorless Vector performance with advanced application flexibility, this compact \u003cstrong style=\"color: #0056b3;\"\u003e1.41 kg\u003c\/strong\u003e hardware unit acts as an intelligent control asset for high-performance machine integration.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetailed Suffix Logic Breakdown:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003e22D-:\u003c\/strong\u003e Identifies the high-performance PowerFlex 40P series, offering enhanced closed-loop velocity capabilities and category-specific safety integration options.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-E-:\u003c\/strong\u003e Specifies a 3-phase operational input voltage rating of 600V AC at standard 50\/60 Hz industrial distribution frequencies.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-4P2-:\u003c\/strong\u003e Denotes an operational continuous output current rating of 4.2 Amperes, matching a 2.2 kW (3 HP) heavy-duty industrial load profile.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-N-:\u003c\/strong\u003e Configures an open-type panel mount protective housing matching an IP20\/NEMA Type Open barrier rating without an integrated EMC filter.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-1-:\u003c\/strong\u003e Indicates a fixed, standard style LED human-interface module (HIM) keypad interface mounted on the face of the drive.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-04-:\u003c\/strong\u003e Designates the default standard production hardware variant, equipped with an onboard dynamic braking transistor and an enhanced internal parameter layer.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensorless Vector Performance:\u003c\/strong\u003e Provides outstanding low-speed torque control and rapid step-load acceleration response across an 80:1 speed range with +\/-1% speed regulation accuracy without requiring an external feedback encoder.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Overload Capacity:\u003c\/strong\u003e Built to withstand demanding cyclic applications, delivering an intermittent current boost of 150% for up to 60 seconds and up to 200% for a brief 3-second safety window to clear sudden physical jams.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRemovable Metal Oxide Varistor (MOV):\u003c\/strong\u003e Designed with a removable grounding junction link to ground, enabling safe operation on ungrounded or IT distribution grids without risking internal components damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Catalog Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e22D-E4P2N104\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Line Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAllen-Bradley PowerFlex 40P Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eInput Phase Profile\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e3-Phase Input Supply Node\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eInput Supply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e600V AC nominal (Operational Window: 414 to 660V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eRated Continuous Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4.2 Amperes continuous duty output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eNominal Motor Power Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2.2 kW (3.0 Horsepower efficiency curve)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOverload Capacity Performance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e150% for 60 seconds; 200% for 3 seconds max protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eEnclosure Protection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOpen Type - IP20 Panel Mount Barrier Unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMechanical Net Mass\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1.41 kg (approx. 3.1 lbs) frame profile\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eEnvironmental Thermal Window\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOperating: -10°C to 50°C (14°F to 122°F) continuous ambient range\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrial Solutions\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling Conveyors:\u003c\/strong\u003e Delivers high start-up torque to smooth out heavy material distribution bottlenecks and completely eliminates motor burnout conditions under fluctuating loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFluid Processing Pumps:\u003c\/strong\u003e Controls centrifugal liquid pumps and dosage loops to scale pump speeds precisely with process requirements, drastically reducing aggregate energy waste.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Packaging Machinery:\u003c\/strong\u003e Maintains consistent tension, quick positioning indexing, and reliable torque profile tracking across filling and bagging lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomated Production Lines:\u003c\/strong\u003e Reduces unexpected facility downtime across critical automotive, manufacturing, and sorting facilities by integrating comprehensive diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003ch3\u003eLine Termination Parameters\u003c\/h3\u003e\n\u003cp\u003eIsolate the primary facility electrical distribution system before starting installation. Terminate incoming 600V 3-phase utility power lines securely to the main line-side terminals (R, S, T \/ L1, L2, L3) of the housing. Output terminal pairs (U, V, W \/ T1, T2, T3) must feed directly into the three-phase motor arrangement. Never apply line voltage to the output pins, as this causes immediate inverter failure.\u003c\/p\u003e\n\n\u003ch3\u003eEnvironmental Clearance and Spacing\u003c\/h3\u003e\n\u003cp\u003eMount the drive vertically inside a clean control enclosure matching the IP20 requirements. Ensure an unblocked airflow clearance profile of at least 120 mm above and below the drive housing, and maintain a minimum horizontal gap of 50 mm between adjacent equipment to allow proper heat dissipation and prevent localized thermal pooling.\u003c\/p\u003e\n\n\u003ch3\u003eControl Separation Protocols\u003c\/h3\u003e\n\u003cp\u003eRoute all low-voltage control lines, RS-485 serial cables, and analog inputs (0-10V\/4-20mA) through conduits completely separate from high-voltage motor and incoming power leads. Analog command lines must utilize shielded twisted-pair cables, with the shield drain terminated solely at the drive's chassis ground terminal block.\u003c\/p\u003e\n\n\u003ch3\u003eMOV Ground Disconnect Option\u003c\/h3\u003e\n\u003cp\u003eWhen deploying the drive on ungrounded or high-impedance (IT) grid configurations, safely disconnect the internal metal oxide varistor (MOV) wire jumper terminal link. This prevents common-mode noise issues and safeguards the internal protection circuits against catastrophic ground fault trips.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Mode Advanced Logic:\u003c\/strong\u003e Offers flexible selection between traditional Volts-per-Hertz (V\/Hz) paths for multi-motor loads and Sensorless Vector Control (SVC) for processes needing high static torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOnboard Dynamic Brake Transistor:\u003c\/strong\u003e Features an integrated braking transistor that enables direct connection of an external dynamic braking resistor network, ensuring controlled deceleration of heavy, high-inertia loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Multi-Point Interfaces:\u003c\/strong\u003e Outfitted with 5 programmable discrete digital inputs, 2 multi-range analog input tracks, and an integrated RS-485 communication module supporting standard serial link commands directly from a PLC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What are the benefits of the Sensorless Vector mode over traditional V\/Hz mode on the 22D-E4P2N104?\u003c\/strong\u003e\u003cbr\u003e\nA1: Sensorless Vector mode uses internal mathematical models of the motor to separate torque and flux currents. This delivers significantly higher torque at low operational speeds (down to 1 Hz) and reacts much faster to sudden mechanical load spikes compared to standard V\/Hz loops.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can this drive be mounted directly to a standard 35mm industrial DIN rail?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes. The compact IP20 housing structure supports both standard 35mm industrial DIN rail snap-on deployment for quick panel installation and traditional rear plate screw mounting for higher-vibration applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Why is the removable MOV configuration link critical for specific facility power grids?\u003c\/strong\u003e\u003cbr\u003e\nA3: On ungrounded or delta-configured IT power systems, phase-to-ground voltages can float unpredictably high. Leaving the MOV linked to ground under these conditions can cause internal components to overheat or fail prematurely; disconnecting the clip safely separates the phase varistors from earth ground.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050722295940,"sku":"22D-E4P2N104","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/22D-E4P2N104.jpg?v=1779371842","url":"https:\/\/www.etowonauto.com\/nb\/products\/22d-e4p2n104-3-phase-adjustable-frequency-drive-allen-bradley","provider":"Etowon Auto","version":"1.0","type":"link"}