{"title":"Pepperl+Fuchs","description":"\u003cp\u003ePepperl+Fuchs er en global leder innen industriell sensorteknologi og intrinsisk sikkerhet. Denne kategorien inkluderer sensorer, isolatorer og grensesnittmoduler som brukes i farlige og prosessautomatiseringsmiljøer, og støtter nøyaktige målinger, signalbehandling og sikker systemdrift.\u003c\/p\u003e","products":[{"product_id":"pepperl-fuchs-kcd2-scd-1-current-driver-signal-conditioner","title":"Pepperl+Fuchs KCD2-SCD-1 Current Driver | Signal Conditioner","description":"\u003ch2\u003eSMART KCD2-SCD-1 Current Driver Signal Conditioner\u003c\/h2\u003e\n\u003cp\u003eThe SMART \u003cstrong style=\"color: #d35400;\"\u003eKCD2-SCD-1\u003c\/strong\u003e is a precision current driver for process control. This 1-channel signal conditioner provides accurate current output. It supports HART communication with I\/P converters and valve positioners. The \u003cstrong\u003eKCD2-SCD-1\u003c\/strong\u003e ensures reliable operation in safety-critical applications up to SIL 2.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Identification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eKCD2-SCD-1\u003c\/strong\u003e current driver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 1-Channel Signal Conditioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e Current driving and conditioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e SIL 2 per IEC 61508 standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Width:\u003c\/strong\u003e 12.5 mm compact design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePower Supply Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e24 V DC nominal\u003c\/span\u003e (19-30 V DC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Power Rail or terminals 9+, 10-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e ≤ 30 mA power consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e ≤ 600 mW heat generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e ≤ 700 mW total usage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple Tolerance:\u003c\/strong\u003e ≤ 10 % input ripple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Analog 4-20 mA input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Terminals 5-, 6+ (control side)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 4-20 mA (limited to ~30 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e \u0026lt;23V or \u0026lt;27V configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e ~6V at 20 mA (\u0026lt;23V mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e \u0026gt;100 kΩ with open wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 4-20 mA precision signal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Capacity:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e0-650 Ω\u003c\/span\u003e maximum load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e ≥13 V at 20 mA output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Terminals 1+, 2- (field side)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Ripple:\u003c\/strong\u003e 20 mV rms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 0.1 % of full scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSafety \u0026amp; Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Level:\u003c\/strong\u003e SIL 2 per IEC 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Breakage Monitoring:\u003c\/strong\u003e Wire break detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Support:\u003c\/strong\u003e I\/P converter and valve positioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Fault detection capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Input\/output separation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount on standard DIN rail in control cabinet\u003c\/li\u003e\n\u003cli\u003eConnect 24V DC power via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eWire 4-20 mA input signal to control side terminals\u003c\/li\u003e\n\u003cli\u003eConnect output to field device (I\/P, positioner)\u003c\/li\u003e\n\u003cli\u003eConfigure voltage mode (\u0026lt;23V or \u0026lt;27V) as needed\u003c\/li\u003e\n\u003cli\u003eVerify grounding and shielding for noise immunity\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does SIL 2 certification mean for this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eKCD2-SCD-1\u003c\/strong\u003e meets Safety Integrity Level 2 requirements for use in safety instrumented systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this driver power two valves simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a 1-channel driver designed for single load devices up to 650 Ω.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does lead breakage monitoring work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt continuously monitors wire integrity and signals if a connection breaks.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePeriodic calibration check and visual inspection of connections are recommended.\u003c\/p\u003e\n\u003cp\u003eFor technical specifications or to order the \u003cstrong\u003eKCD2-SCD-1\u003c\/strong\u003e, contact \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eContent provided by Etowon Auto.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":51472469229700,"sku":"KCD2-SCD-1","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/KCD2-SCD-1-3.jpg?v=1768743199"},{"product_id":"kcd2-sot-ex1-lb-isolated-barrier-pepperl-fuchs","title":"KCD2-SOT-Ex1.LB Isolated Barrier | Pepperl+Fuchs","description":"\u003ch2\u003ePepperl+Fuchs KCD2-SOT-Ex1.LB Switch Amplifier\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs \u003cstrong style=\"color: #d35400;\"\u003eKCD2-SOT-Ex1.LB\u003c\/strong\u003e is an isolated switch amplifier for hazardous areas. This 1-channel barrier interfaces NAMUR sensors with control systems. It provides two transistor outputs for signal splitting applications. The Pepperl+Fuchs \u003cstrong\u003eKCD2-SOT-Ex1.LB\u003c\/strong\u003e offers safe operation in explosive atmospheres with ATEX certification.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Identification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eKCD2-SOT-Ex1.LB\u003c\/strong\u003e switch amplifier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 1-Channel Isolated Barrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e Digital input signal conditioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e SIL 2, SC 3 per IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ATEX certified for hazardous areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Width:\u003c\/strong\u003e 12.5 mm compact design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePower Supply Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e24 V DC nominal\u003c\/span\u003e (19-30 V DC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Power Rail or terminals 9+, 10-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 20-15 mA typical consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e ≤ 700 mW maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple Tolerance:\u003c\/strong\u003e ≤ 10 % input ripple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Digital Input (NAMUR or dry contact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Terminals 1+, 2- (field side)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNAMUR Values:\u003c\/strong\u003e 10 V DC \/ 8 mA per EN 60947-5-6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Point:\u003c\/strong\u003e 1.2-2.1 mA with 0.2 mA hysteresis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Fault Detection:\u003c\/strong\u003e Breakage I ≤ 0.1 mA, short I ≥ 6.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Requirements:\u003c\/strong\u003e Min. 100 µs pulse\/pause ratio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e Two passive transistor outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Output I: terminals 5,6; Output II: terminals 7,8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 30 V DC maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 50 mA per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≤ 200 µs fast switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-Signal Level:\u003c\/strong\u003e (External voltage) - 3V max at 50 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0-Signal Level:\u003c\/strong\u003e Blocked output (≤10 µA leakage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e ≤ 5 kHz maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSafety \u0026amp; Isolation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Level:\u003c\/strong\u003e SIL 2, Systematic Capability SC 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Reinforced insulation 300 Veff\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Ratings:\u003c\/strong\u003e Input\/Output: 300 Veff reinforced\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e ATEX certified [Ex ia Ga] IIC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IP20 for indoor use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eConfiguration \u0026amp; Display\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e DIP switch settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Elements:\u003c\/strong\u003e LED status indicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLabeling:\u003c\/strong\u003e Front space for identification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Reversible operation possible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Splitting:\u003c\/strong\u003e 1 input to 2 outputs capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20°C to +70°C standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Range:\u003c\/strong\u003e Up to 70°C with derating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35 mm DIN rail per EN 60715\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 12.5 x 119 x 114 mm (WxHxD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 100 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCertifications \u0026amp; Compliance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Certificate:\u003c\/strong\u003e BASEEFA 13 ATEX 0080\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 2014\/30\/EU, EN 61326-1:2013\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e IEC 61010-1:2010 compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount on 35 mm DIN rail in appropriate enclosure\u003c\/li\u003e\n\u003cli\u003eConnect 24V DC power via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eWire NAMUR sensor or dry contact to input terminals\u003c\/li\u003e\n\u003cli\u003eConnect outputs to control system inputs\u003c\/li\u003e\n\u003cli\u003eConfigure DIP switches for required operation mode\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding for hazardous area installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main purpose of this switch amplifier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Pepperl+Fuchs \u003cstrong\u003eKCD2-SOT-Ex1.LB\u003c\/strong\u003e safely interfaces hazardous area sensors with control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this with standard mechanical contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it accepts both NAMUR sensors and dry contact inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"signal splitter\" function mean?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt can take one input signal and provide two identical output signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does line fault detection work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt detects open circuits (\u0026lt;0.1 mA) and short circuits (\u0026gt;6.5 mA) in field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat hazardous area classifications does it support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eATEX Zone 0\/1 for gas and Zone 20\/21 for dust explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat configuration options are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDIP switches allow setting operating mode, output configuration, and fault behavior.\u003c\/p\u003e\n\u003cp\u003eFor technical specifications or to order the \u003cstrong\u003eKCD2-SOT-Ex1.LB\u003c\/strong\u003e, email \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eContent provided by Etowon Auto.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":51472470638724,"sku":"KCD2-SOT-EX1.LB","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/KCD2-SOT-EX1.LB.jpg?v=1768743596"},{"product_id":"pepperl-fuchs-kcd2-stc-ex1-transmitter-power-supply","title":"Pepperl+Fuchs KCD2-STC-Ex1 Transmitter Power Supply","description":"\u003ch2\u003ePepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs \u003cstrong style=\"color: #d35400;\"\u003eKCD2-STC-Ex1\u003c\/strong\u003e is a transmitter power supply for field instruments. This SMART device provides power to 2-wire transmitters in hazardous areas. It ensures reliable operation for analog measurement devices. The Pepperl+Fuchs \u003cstrong\u003eKCD2-STC-Ex1\u003c\/strong\u003e offers intrinsic safety for process control applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Identification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e \u003cstrong\u003eKCD2-STC-Ex1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Analog Input for field transmitters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Side:\u003c\/strong\u003e Field side installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20 enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePower Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e1.1 Watt\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Power Rail or terminals 9+, 10-\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e \u0026lt; 10 Hz operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Protection:\u003c\/strong\u003e Intrinsic safety design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Delivery:\u003c\/strong\u003e For 2-wire transmitters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eConnection Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Terminals:\u003c\/strong\u003e 1+, 2+, 3- for transmitter wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Screw terminal connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Supports standard field wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e DIN rail mounting standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e Compatible with Power Rail system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 1.2 x 11.4 x 12.4 cm (W x H x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.15 kg (150 grams) net weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 1.5 kg packaged weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Compact industrial housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard 35mm DIN rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter Power:\u003c\/strong\u003e Supplies 2-wire field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conditioning:\u003c\/strong\u003e Analog input processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Design:\u003c\/strong\u003e Intrinsically safe for Ex areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Transmitter status indication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Works with SMART transmitters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 for indoor use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Standard industrial rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Areas:\u003c\/strong\u003e ATEX\/IECEx certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Compliance:\u003c\/strong\u003e Industrial electromagnetic standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Suitable for industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount on 35mm DIN rail in control cabinet\u003c\/li\u003e\n\u003cli\u003eConnect power via Power Rail or terminal blocks\u003c\/li\u003e\n\u003cli\u003eWire field transmitter to terminals 1+, 2+, 3-\u003c\/li\u003e\n\u003cli\u003eFollow intrinsic safety wiring requirements\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding and barrier installation\u003c\/li\u003e\n\u003cli\u003eCheck transmitter compatibility before connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCertifications \u0026amp; Safety\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety:\u003c\/strong\u003e Ex ia certification for Zone 0\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e European hazardous area compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International explosive atmosphere standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Standards:\u003c\/strong\u003e Pepperl+Fuchs manufacturing quality\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e Electromagnetic compatibility compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Systems:\u003c\/strong\u003e Compatible with DCS and PLC systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitters:\u003c\/strong\u003e Supports SMART\/HART field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Systems:\u003c\/strong\u003e Integrates with Power Rail distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Systems:\u003c\/strong\u003e Suitable for SIL-rated applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking:\u003c\/strong\u003e Process instrument network compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of transmitters does this power supply support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Pepperl+Fuchs \u003cstrong\u003eKCD2-STC-Ex1\u003c\/strong\u003e powers 2-wire SMART and HART transmitters with analog signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this in Zone 0 hazardous areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, with proper installation it is certified for Zone 0\/1 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Power Rail connection option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower Rail allows daisy-chain power connection without individual wiring to each device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many transmitters can one unit power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTypically one transmitter per unit, depending on the transmitter's power requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wiring configuration do terminals 1+, 2+, 3- support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese terminals accommodate standard 2-wire transmitter connections with signal and power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs special training required for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation should be performed by qualified personnel familiar with intrinsic safety requirements.\u003c\/p\u003e\n\u003cp\u003eFor technical support or to order the \u003cstrong\u003eKCD2-STC-Ex1\u003c\/strong\u003e, contact \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eContent provided by Etowon Auto.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":51472472637572,"sku":"KCD2-STC-EX1","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/KCD2-STC-EX1.jpg?v=1768743806"}],"url":"https:\/\/www.etowonauto.com\/nb\/collections\/pepperl-fuchs.oembed","provider":"Etowon Auto","version":"1.0","type":"link"}