{"title":"General Electric","description":"","products":[{"product_id":"ge-fanuc-ic694mdl260-high-density-32-inputs","title":"GE Fanuc IC694MDL260 High-Density 32 Inputs","description":"\u003ch2\u003eGE Fanuc IC694MDL260 32-Point High-Density Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL260\u003c\/strong\u003e is a 32-point discrete input module for PACSystem RX3i. Formerly by GE Fanuc, now Emerson Automation, it features 32 channels in 4 isolated groups of 8. This high-density module accepts 120 Volts AC nominal and supports positive logic wiring.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL260\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystem RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Points:\u003c\/strong\u003e 32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroups:\u003c\/strong\u003e 4 isolated groups of 8 channels each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 120 Volts AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 0-132 VAC (47-63 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e 70-132 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e 0-20 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 7 mA per channel at rated voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current:\u003c\/strong\u003e 6 mA minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Current:\u003c\/strong\u003e 2.5 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 220 mA from 5 VDC backplane bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter Time:\u003c\/strong\u003e 20-2540 ms in 20 ms increments (CPU configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Up to 840 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Isolation:\u003c\/strong\u003e 264 VAC continuous, 1500 VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Isolation:\u003c\/strong\u003e 264\/1500 Volts AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Terminal block presence detected and reported to RX3i CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard or expansion base with terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Series 90-30 PLC devices, RX3i PacSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0-50 degrees Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIP Switch:\u003c\/strong\u003e Rear-mounted for input filter time adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Lifecycle:\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eIC694MDL260\u003c\/strong\u003e discrete input module\u003c\/li\u003e\n\u003cli\u003eTerminal block sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow are the 32 inputs organized on the IC694MDL260?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL260\u003c\/strong\u003e has 4 isolated groups with 8 channels per group. Each group uses a common reference.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat happens if one group's common reference fails?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnly that specific group becomes unusable. The other three groups continue operating normally.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan I adjust input filter time during operation?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes, the controller can modify filter time via assigned memory. New setting equals time value divided by 20.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51047938326660,"sku":"IC694MDL260","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL260.jpg?v=1772288847"},{"product_id":"ac-voltage-input-module-ic694mdl250-ge-fanuc","title":"AC Voltage Input Module IC694MDL250 GE Fanuc","description":"\u003ch2\u003eGE Fanuc IC694MDL250 16-Point Isolated Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL250\u003c\/strong\u003e is a 16-point discrete input module for PACSystem RX3i. Formerly by GE Intelligent Platforms, now Emerson Automation, it features individually isolated channels rated at 120 Volts AC. This high-voltage module supports hot-swap and delivers reliable performance for industrial applications.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystem RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Points:\u003c\/strong\u003e 16 individually isolated channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 120 Volts AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 0-132 VAC (47-63 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e 70-132 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e 0-20 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 14.5 mA typical, 7 mA per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current:\u003c\/strong\u003e 6 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Current:\u003c\/strong\u003e 2.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 30 ms on, 45 ms off maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 60 mA from 5 VDC backplane bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter Times:\u003c\/strong\u003e 20-2540 ms in 20 ms increments (CPU configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250V continuous optical, 1500V AC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS-485, high-speed serial bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel or DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors:\u003c\/strong\u003e IC694TBBx32 or IC694TBSx32 terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL 508, CSA C22.2 No 142M1987, Class 1 Division 2 Groups A,B,C,D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Requirement:\u003c\/strong\u003e Firmware version 3.5 or later\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Lifecycle:\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot compatibility:\u003c\/strong\u003e Fits any available slot in PACSystem RX3i racks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration options:\u003c\/strong\u003e Use as local I\/O in CPU rack or distributed I\/O node with communication adapters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel or DIN rail mounting base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Class 1 Division 2 rated, clean environment with minimal EMC noise recommended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal blocks:\u003c\/strong\u003e Requires IC694TBBx32 or IC694TBSx32 connectors (sold separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming connection:\u003c\/strong\u003e RS-485 port connects to programming terminal or PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e discrete input module\u003c\/li\u003e\n\u003cli\u003eTerminal blocks sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat CPU firmware does the IC694MDL250 require?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e requires CPU firmware version 3.5 or later for normal operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan this module continue working if one channel fails?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes, individual channel isolation allows the \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e to operate normally even with a failed input channel.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat terminal blocks work with this module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse IC694TBBx32 or IC694TBSx32 connectors. These terminal blocks are sold separately.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51047938359428,"sku":"IC694MDL250","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL250-1.jpg?v=1772288396"},{"product_id":"ge-fanuc-ic694mdl230-8-point-input-module","title":"GE Fanuc IC694MDL230 8-Point Input Module","description":"\u003ch2\u003eGE Fanuc IC694MDL230 Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL230\u003c\/strong\u003e is an 8-point input module for RX3i PacSystem. It connects switches, sensors, and buttons to PLCs at 120 Volts AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL230\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX3i PacSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Points:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Volts AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hertz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 60 mA from 5V bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 30-45 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250V AC field to backplane, 1500V AC field to frame\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e UL 508\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swap capable:\u003c\/strong\u003e Replace \u003cstrong\u003eIC694MDL230\u003c\/strong\u003e without system shutdown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indicators:\u003c\/strong\u003e 8 status lights show input on\/off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositive logic:\u003c\/strong\u003e Works with standard industrial sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Onboard monitoring for operational flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel or DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Class 1, Division 2 rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e All GE RX3i devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eIC694MDL230\u003c\/strong\u003e input module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat voltage does this module use?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e120 Volts AC only. Do not use with higher voltages.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow many input points?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e8 points, each with its own LED status indicator.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs it compatible with existing RX3i racks?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes, it works with all GE RX3i backplanes.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51047938392196,"sku":"IC694MDL230","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL230.jpg?v=1772287148"},{"product_id":"ic694mdl330-ge-fanuc-output-module-8-point","title":"IC694MDL330 GE Fanuc Output Module 8 Point","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL330\u003c\/strong\u003e is an 8-point output module for PACSystems RX3i systems. It operates at 120\/240VAC with 2A per point output. \u003c\/p\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003eBrand:\u003c\/span\u003e \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003eModel:\u003c\/span\u003e \u003cstrong\u003eIC694MDL330\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003eRated Voltage:\u003c\/span\u003e 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003eOutput Voltage Range:\u003c\/span\u003e 85–264 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003eRated Output Current:\u003c\/span\u003e 2 A per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c0392b;\"\u003eMaximum Inrush Current:\u003c\/span\u003e 20 A for 1 cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003eOutput Frequency:\u003c\/span\u003e 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOutput Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Output Points: 8\u003c\/li\u003e\n\u003cli\u003eGroup Division: 2 isolated groups of 4 outputs each\u003c\/li\u003e\n\u003cli\u003eGroup Isolation: Independent commons for each group\u003c\/li\u003e\n\u003cli\u003eFuse Protection: 5 A fuse per group common\u003c\/li\u003e\n\u003cli\u003eLoad Compatibility: High inrush inductive and resistive loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0–60°C (32–140°F)\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40–85°C (-40–185°F)\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5–95% non-condensing\u003c\/li\u003e\n\u003cli\u003eShelf Life: 1 year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the output configuration of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IC694MDL330 has 8 outputs arranged in 2 isolated groups of 4 outputs each. Each group has independent commons for flexible wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of loads can this module handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It supports high inrush inductive and resistive loads with 2A continuous per point and 20A inrush capability for one cycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protection features are included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Each group has a 5A fuse for overcurrent protection. Each channel includes an RC snubber for transient suppression and noise reduction.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51047938424964,"sku":"IC694MDL330","price":232.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL330.jpg?v=1774260468"},{"product_id":"ic694mdl390-ge-fanuc-5-output-module-120-240vac","title":"IC694MDL390 GE Fanuc 5 Output Module 120-240VAC","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL390\u003c\/strong\u003e is a 5-point discrete output module for PACSystem RX3i systems. It operates at 120-240VAC with 2A per channel. \u003c\/p\u003e\n\u003ch2\u003eModule Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1a73e8;\"\u003eBrand:\u003c\/span\u003e \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1a73e8;\"\u003eModel:\u003c\/span\u003e \u003cstrong\u003eIC694MDL390\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1a73e8;\"\u003eSeries:\u003c\/span\u003e RX3i PACSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1a73e8;\"\u003eNumber of Output Points:\u003c\/span\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1a73e8;\"\u003eCommon Configuration:\u003c\/span\u003e Each point has a separate common\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1a73e8;\"\u003eOutput Type:\u003c\/span\u003e AC only (no DC support)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage Range: 85 to 264 VAC\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 120 to 240 VAC\u003c\/li\u003e\n\u003cli\u003eOutput Current: 2 A per channel\u003c\/li\u003e\n\u003cli\u003eInrush Current: 25 A per cycle\u003c\/li\u003e\n\u003cli\u003eFrequency Supported: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eFuse Protection: 3 A fuse per output point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are the outputs configured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 5 outputs with each point having a separate common. Provides maximum wiring flexibility for individual load control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the fuse rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Each output point has a 3A fuse for overcurrent protection. Replace only with same rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module switch DC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. This is AC only output module. Use DC output modules for DC load switching.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51047938457732,"sku":"IC694MDL390","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL390.jpg?v=1774263919"},{"product_id":"ge-fanuc-ic694mdl310-plc-output-module-12-channels","title":"GE Fanuc IC694MDL310 PLC Output Module 12 Channels","description":"\u003ch2\u003eGE Fanuc IC694MDL310 12-Point Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL310\u003c\/strong\u003e is a 12-point output module for RX3i PacSystem. It operates at 120 Volts AC with 0.5 Amps per point. This module installs in any I\/O slot and controls inductive and incandescent loads.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL310\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX3i PacSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Points:\u003c\/strong\u003e 12 (2 isolated groups of 6)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 120 Volts AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 85-132 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 0.5 Amps per point maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 5 Amps maximum for one cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 210 mA from 5V backplane bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e 3 Amp fuses per group, RC snubbers per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e Numbered LEDs show ON\/OFF status; red LED indicates blown fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRed Bands:\u003c\/strong\u003e Identify as high-voltage module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eIC694MDL310\u003c\/strong\u003e output module\u003c\/li\u003e\n\u003cli\u003eTerminal blocks sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan the IC694MDL310 operate on DC power?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo, the \u003cstrong\u003eIC694MDL310\u003c\/strong\u003e works only with AC power sources. Using DC will damage the module.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow do I know if an output fuse blows?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe LED for that output turns red when its group fuse blows. Normal operation shows green illumination.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat loads can this module drive?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith 5 Amp inrush capacity, it drives inductive loads like relays and incandescent lamps effectively.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51047938490500,"sku":"IC694MDL310","price":204.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL310-1.jpg?v=1772289242"},{"product_id":"ge-ic693alg392-8-channel-current-voltage-output-module","title":"GE IC693ALG392 8-kanals strøm- og spenningsutgangsmodul","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eGE Fanuc IC693ALG392 Analog utgangsmodul\u003c\/h2\u003e\n\u003ch3\u003eProduktoversikt\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #2c6e9e;\"\u003eIC693ALG392\u003c\/strong\u003e er en 8-kanals analog utgangsmodul for GE Fanuc Series 90-30 og RX3i PLC-systemer. Gir spenningsutganger (0 til +10V, -10 til +10V) og strømutganger (0 til 20 mA, 4 til 20 mA). Fabrikkalibrert med konfigurerbar 15 eller 16 bits oppløsning. Ideell for VFD-er, styringsventiler, posisjoneringsenheter, opptakere og dataloggere. Modulvekt 0,45 kg.\u003c\/p\u003e\n\u003ch3\u003eTekniske spesifikasjoner\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eVerdi\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMerke\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSerie\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSerie 90-30 \/ RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDelenummer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIC693ALG392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAntall kanaler\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSpenningområde\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0 til 10V, -10 til +10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStrømområde\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e4 til 20 mA, 0 til 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eEkstern forsyningsspenning\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e20 til 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIntern forsyningsspenning\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e5 VDC fra PLC-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInternt strømforbruk\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e110 mA ved 5 VDC, 315 mA ved 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOppdateringshastighet\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e8 ms (alle kanaler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOppløsning (0-10V \/ -10 til +10V)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0,312 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOppløsning (4-20 mA)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0,5 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOppløsning (0-20 mA)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0,625 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eVekt\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0,45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOppløsning etter utgangsområde\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eUtgangsområde\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eOppløsning (per LSB)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0 til 20 mA\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0,625 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e4 til 20 mA\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0,5 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0 til 10 VDC\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0,3125 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-10 til +10 VDC\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0,3125 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNøkkelfunksjoner\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 enkeltendede utgangskanaler\u003c\/li\u003e\n\u003cli\u003eKonfigurerbar 15 eller 16 bits oppløsning per kanal\u003c\/li\u003e\n\u003cli\u003eFabrikkalibrert, krever ingen feltkalibrering\u003c\/li\u003e\n\u003cli\u003e8 ms oppdateringshastighet for alle kanaler\u003c\/li\u003e\n\u003cli\u003eKrever isolert 24 VDC ekstern strømforsyning\u003c\/li\u003e\n\u003cli\u003ePasser i alle RX3i chassis-spor\u003c\/li\u003e\n\u003cli\u003eIngen grense for antall rack, avhenger av kontrollerens analoge datakapasitet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypiske bruksområder\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStyring av frekvensomformere (VFD)\u003c\/li\u003e\n\u003cli\u003eStyringsventiler og posisjoneringsenheter\u003c\/li\u003e\n\u003cli\u003eSignalomformere\u003c\/li\u003e\n\u003cli\u003eDataretransmisjon til opptakere og dataloggere\u003c\/li\u003e\n\u003cli\u003eModulerende kontroll av instrumenter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOfte stilte spørsmål\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Hvilken strømforsyning krever IC693ALG392?\u003c\/strong\u003e\u003cbr\u003eA1: Krever isolert 24 VDC ekstern strømforsyning koblet til angitt terminalblokk, pluss 5 VDC fra PLC-backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Hva er oppdateringshastigheten?\u003c\/strong\u003e\u003cbr\u003eA2: 8 millisekunder for alle åtte kanaler.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Kreves feltkalibrering?\u003c\/strong\u003e\u003cbr\u003eA3: Nei. Modulen er fabrikkalibrert. Kalibreringen inkluderer 0,625 µA for 0-20 mA, 0,5 µA for 4-20 mA, og 0,3125 mV for spenningsområder.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050730619012,"sku":"IC693ALG392","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693ALG392.jpg?v=1781100581"},{"product_id":"ge-fanuc-ic694alg542-4-input-2-output-analog-i-o-module","title":"GE Fanuc IC694ALG542 | 4 Input 2 Output Analog I\/O Module","description":"\u003ch2\u003eGE Fanuc IC694ALG542 Analog I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ALG542\u003c\/strong\u003e is an analog I\/O module for RX3i systems. Features 4 differential input channels and 2 single-ended output channels. High 14-bit input resolution with 1 ms per channel sampling time. \u003c\/p\u003e\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e IC694ALG542\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 4 differential inputs, 2 single-ended outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput resolution:\u003c\/strong\u003e 14 bits (1 bit = 1.22 µV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput sampling time:\u003c\/strong\u003e 1 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADC accuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e 450,000 hours at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShelf life:\u003c\/strong\u003e 12 months from manufacture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 220 g (0.22 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePower \u0026amp; isolation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane power:\u003c\/strong\u003e 120 mA @5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal power:\u003c\/strong\u003e 250 mA @24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation:\u003c\/strong\u003e 3.6W max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 600V DC channel-to-channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC694ALG542\u003c\/strong\u003e analog I\/O module\u003c\/li\u003e\n\u003cli\u003eFactory packaging\u003c\/li\u003e\n\u003cli\u003e12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the input and output channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e4 differential inputs and 2 single-ended outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the input resolution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e14 bits (1.22 µV per bit).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the sampling time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1 ms per channel.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050730684548,"sku":"IC694ALG542","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694ALG542-1.jpg?v=1774170198"},{"product_id":"ge-fanuc-ic694alg223-16-channel-analog-input-module","title":"GE Fanuc IC694ALG223 | 16-Channel Analog Input Module","description":"\u003ch2\u003eGE Fanuc IC694ALG223 16-Channel Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ALG223\u003c\/strong\u003e is a 16-channel analog input module for RX3i systems. Supports 0-20mA and 4-20mA current inputs with 12-bit resolution. \u003c\/p\u003e\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e IC694ALG223\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 single-ended analog inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput signal ranges:\u003c\/strong\u003e 0-20mA, 4-20mA (normal), 4-20mA (enhanced)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate rate:\u003c\/strong\u003e 13 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e 250 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput filter response:\u003c\/strong\u003e 19 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg (approx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow many channels does this module have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e16 single-ended analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input ranges are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e0-20mA, 4-20mA normal, and 4-20mA enhanced with open-wire detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the update rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e13 ms per channel.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050730717316,"sku":"IC694ALG223","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694ALG223-1.jpg?v=1774166619"},{"product_id":"analog-input-module-ic200alg620-ge-fanuc","title":"Analog Input Module IC200ALG620 GE Fanuc","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200ALG620 VersaMax RTD Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200ALG620\u003c\/strong\u003e is a VersaMax RTD input module. It has 4 channels for temperature and resistance measurement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86c1;\"\u003eGE Fanuc IC200ALG620\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 4 RTD\/resistance inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16 bits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 210 ms per channel at 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.15% for resistance and RTD measurement at 25°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Types:\u003c\/strong\u003e Platinum (25, 100, 1000Ω), Copper (10, 50, 100Ω), Nickel (100, 120Ω), Ni\/Fe (604Ω).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e 3-wire and 4-wire RTD support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Range:\u003c\/strong\u003e 0-500 Ω and 0-3000 Ω.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 125 mA at 5V and 3.3V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLEDs:\u003c\/strong\u003e FLD PWR and OK indicators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-slot VersaMax module.\u003c\/li\u003e\n\u003cli\u003eMaximum lead resistance: 5 Ω per lead.\u003c\/li\u003e\n\u003cli\u003eOperating temperature: 0-60°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many channels?\u003c\/strong\u003e The \u003cstrong\u003eIC200ALG620\u003c\/strong\u003e has 4 RTD input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat RTD types?\u003c\/strong\u003e Supports Pt, Cu, Ni, and Ni\/Fe sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule weight?\u003c\/strong\u003e 200 grams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor quotes and support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050730881156,"sku":"IC200ALG620","price":124.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200ALG620.jpg?v=1765713338"},{"product_id":"ge-fanuc-ic694alg220-4-channel-analog-input-module","title":"GE Fanuc IC694ALG220 | 4-Channel Analog Input Module","description":"\u003ch2\u003eGE Fanuc IC694ALG220 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ALG220\u003c\/strong\u003e is a 4-channel analog input module for the RX3i series. Supports voltage range -10V to +10V and current range 4-20mA. 12-bit resolution with 1ms per channel conversion speed.\u003c\/p\u003e\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel number:\u003c\/strong\u003e IC694ALG220\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 4 analog inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage range:\u003c\/strong\u003e -10V to +10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput current range:\u003c\/strong\u003e 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion speed:\u003c\/strong\u003e 1ms per channel (4ms total update)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12-bit (4,096 steps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e 100 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 1,500 Vrms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePower \u0026amp; environmental\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 0.125 W typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax load @5V DC:\u003c\/strong\u003e 27 mA \/ 0.135 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L×W×H):\u003c\/strong\u003e 127 × 25 × 113 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.20 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot swap:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow many channels does this module have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e4 analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the conversion speed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1ms per channel, 4ms total update rate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the resolution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e12-bit (4,096 steps).\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050730913924,"sku":"IC694ALG220","price":211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694ALG220.jpg?v=1774165660"},{"product_id":"ic694alg232-input-module-ge-fanuc-0-10v","title":"IC694ALG232 Input Module | GE Fanuc 0-10V","description":"\u003ch2\u003eGE Fanuc IC694ALG232 16-Channel Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ALG232\u003c\/strong\u003e is a 16-channel analog input module for PACSystems RX3i systems. Supports 0-10V and ±10V voltage inputs with 0.3125 mV\/count resolution. \u003c\/p\u003e\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e IC694ALG232\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal channels:\u003c\/strong\u003e 16 analog inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel configuration:\u003c\/strong\u003e 16 single-ended or 8 differential\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage ranges:\u003c\/strong\u003e 0-10V (unipolar), ±10V (bipolar)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital resolution:\u003c\/strong\u003e 0.3125 mV\/count (both ranges)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg (approx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePerformance specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate rate (single-ended):\u003c\/strong\u003e 5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate rate (differential):\u003c\/strong\u003e 3 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput filter response (single-ended):\u003c\/strong\u003e 23 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput filter response (differential):\u003c\/strong\u003e 38 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow many channels does this module have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e16 analog input channels configurable as single-ended or differential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage ranges are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e0-10V unipolar and ±10V bipolar.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the update rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e5 ms for single-ended, 3 ms for differential configuration.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050730946692,"sku":"IC694ALG232","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694ALG232-1.jpg?v=1774167063"},{"product_id":"ic200alg265-versamax-15-channel-voltage-current-input-ge-fanuc","title":"IC200ALG265 VersaMax 15-Channel Voltage\/Current Input | GE Fanuc","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200ALG265 15-Channel Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003eIC200ALG265\u003c\/strong\u003e is a versatile 15-channel analog input module for VersaMax systems. It accepts both voltage and current signals for flexible industrial measurement applications. This enhanced module features improved diagnostics and overvoltage protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003eIC200ALG265\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 15 Single-Ended Inputs (1 Group)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Input:\u003c\/strong\u003e -10 to +10 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input:\u003c\/strong\u003e 4 to 20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 100 kΩ (Voltage), 100 Ω (Current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.3% typical (±1% maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 15 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 7.5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 5 VDC from backplane (100 mA max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250VAC continuous; 1500VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e OK LED\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat signals does the IC200ALG265 support?\u003c\/strong\u003e It supports both ±10V voltage and 4-20mA current signals on its 15 channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat improvements does it have over the IC200ALG264?\u003c\/strong\u003e The \u003cstrong style=\"color: #d35400;\"\u003eIC200ALG265\u003c\/strong\u003e adds overvoltage protection and enhanced diagnostic features.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is the module powered?\u003c\/strong\u003e It draws 5VDC power directly from the VersaMax backplane.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731012228,"sku":"IC200ALG265","price":162.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200ALG265.jpg?v=1765114840"},{"product_id":"ge-fanuc-ic697alg230-series-90-70-analog-input-module","title":"GE Fanuc IC697ALG230 Series 90-70 Analog inngangsmodul","description":"\u003ch2\u003eProduktoversikt\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc IC697ALG230\u003c\/strong\u003e er en høypresisjons, 8-kanals analog inngangsmodul utviklet for Series 90-70 programmerbar logisk kontroller (PLC)-plattformen. Med en ultralett vekt på 0,3 kg (0,66 lbs) konverterer dette høy-tetthetskortet kontinuerlige industrielle spennings- og strømsløyfer til digitale data for vert-CPUen. Dets allsidige front-end maskinvareoppsett gjør det ideelt for sanntidsovervåking av strømningsmålere, trykktransmittere og temperatursensorer i høyt automatiserte prosessanlegg.\u003c\/p\u003e\n\n\u003ch2\u003eKjernefordeler\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAllsidig dobbeltsignalarkitektur:\u003c\/strong\u003e Kan konfigureres til å akseptere enten standard 4 til 20 mA strømsløyfer eller allsidige -10 til +10 VDC spenningsområder på ett enkelt kortoppsett.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHurtig sløyfediagnostikk:\u003c\/strong\u003e Leverer raske oppdateringshastigheter mellom 2,4 ms og 2,8 ms på alle aktive kanaler for å muliggjøre umiddelbar sporing av svært dynamiske prosessvariabler.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLaboratoriekvalitet på feltpresisjon:\u003c\/strong\u003e Oppnår høy presisjon med basis-toleranser holdt stramme på ±0,05 % av full skala og ±0,1 % av måleverdien, noe som holder kalibreringsavvik til et absolutt minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske spesifikasjoner\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpesifikasjonsdetaljer\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMerke \/ Modellnummer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc \/ IC697ALG230\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBruttovekt\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0,3 kg (0,66 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eSystemplattform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSeries 90-70 PLC-system\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eInngangskanal kapasitet\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8 separate analoge inngangskanaler\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eStøttede inngangstyper\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eStrøm: 4 til 20 mA \/ Spenning: -10 VDC til +10 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eModul oppdateringshastighet\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2,4 ms til 2,8 ms total konverteringsrate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eAnalog strøm nøyaktighet\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e±0,05 % av full skala \/ ±0,1 % av måleverdien\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eKoblingsblokk grensesnitt\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e40-pinners terminalkontakt\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eKonstruksjon\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eRobust, åpen arkitektur PCB-chassis bygget for tunge industrielle spor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallasjons- og ingeniørveiledning\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInnsetting i chassis:\u003c\/strong\u003e Juster de lette 0,3 kg modulskinnene med de valgte sporene inne i Series 90-70 rammen. Skyv modulen helt bakover til de bakre multi-pinnetilkoblingene sitter sikkert i systemets bakplan.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeltgrensesnittoppsett:\u003c\/strong\u003e Før feltinstrumenteringssløyfer direkte inn i 40-pinners terminalblokkmonteringen. Hold signallinjer isolert fra høyspennings AC-linjer for å opprettholde standard nøyaktighet og forhindre magnetisk støyinnsprøytning.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgramvarekartlegging:\u003c\/strong\u003e Bruk ditt standard logikkprogrammeringsverktøy for å kalibrere individuelle kanalinnstillinger for enten 4-20mA eller ±10V skalaer basert på dine faktiske transmitterinstrumentprofiler.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Kan dette inngangskortet håndtere strømsløyfer og spenningssignaler samtidig?\u003c\/strong\u003e\u003cbr\u003e\nA1: Ja, modulen kan programvarekonfigureres per kanalgruppe for å håndtere standard 4 til 20 mA strøm og -10 til +10 VDC instrumenteringssignaler sømløst.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Hvor raskt oppdaterer modulen de behandlede verdiene tilbake til PLC-racket?\u003c\/strong\u003e\u003cbr\u003e\nA2: Maskinvaren utfører interne konverteringer og kanaloppdateringer raskt, og leverer en responsiv oppdateringshastighet på 2,4 ms til 2,8 ms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Påvirker den lette konstruksjonen dens fysiske holdbarhet på fabrikkgulvet?\u003c\/strong\u003e\u003cbr\u003e\nA3: Nei. Med bare 0,3 kg reduserer den lette profilen belastningen på bakplanet, mens den robuste underliggende strukturelle designen sikrer full beskyttelse mot elektriske støt og vibrasjonstopper.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731044996,"sku":"IC697ALG230","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697ALG230.jpg?v=1781618896"},{"product_id":"high-resolution-analog-voltage-ic697alg321-ge-fanuc","title":"Høyoppløselig analog spennings-IC IC697ALG321 GE Fanuc","description":"\u003ch2\u003eProduktoversikt\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc IC697ALG321\u003c\/strong\u003e er en høyoppløselig, 4-kanals analog spenningsinngangsmodul designet for presis sporing innenfor Series 90-70 programmerbar logisk kontroller (PLC)-plattformen. Med en vekt på omtrent 1,81 kg (4,0 lbs) fanger dette høyytelseskortet både unipolare og bipolare signaler i området -10 til +10 Volt. Det konverterer kontinuerlige eksterne elektriske variabler til et digitalt 2-komplementsformat, og leverer ultrarask behandlingshastighet og datadypde som er nødvendig for kompleks lukket sløyfe prosessovervåking.\u003c\/p\u003e\n\n\u003ch2\u003eKjerne tekniske fordeler\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e16-bits oppløsningsytelse:\u003c\/strong\u003e Benytter en avansert konverteringsvei som plasserer data i et 16-bits WORD-format med 14-bit monotoni, og maksimerer målenøyaktigheten for sensitive industrielle indikatorer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHøyhastighets signalomforming:\u003c\/strong\u003e Leverer en rask 2-millisekunders konverteringsrate over aktive felt, og sikrer sanntidsoppdateringer for dynamiske kontrollarkitekturer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOmfattende alarmkonfigurasjon:\u003c\/strong\u003e Støtter uavhengig innstilling av høy- og lavgrense for alarm per kanal, noe som muliggjør rask feilisolering før systemkritiske grenser overskrides.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske spesifikasjoner\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpesifikasjonsdetaljer\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMerke \/ Modellnummer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc \/ IC697ALG321\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBruttovekt\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1,81 kg (4,0 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eSystemseriekompatibilitet\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSerie 90-70 PLC-system\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eAnaloge innganger\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4 spenningskanaler (støtter enkeltended eller differensiell modus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eSpenningens rekkevidde\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-10 VDC til +10 VDC (Unipolar og Bipolar moduser)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eDatadypdeoppløsning\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e16 biter (med 14-bit monotoni; internt behandlet via 12-bit konverter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eKonverteringsbehandlingshastighet\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2 ms oppdateringsfrekvens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eInngangsfilterfrekvens\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e41 Hz (Enkeltended modus) \/ 82 Hz (Differensiell modus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eInngangsimpedans\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e250 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eFabrikkalibreringsgrense\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSatt til 10 Volt ±2 mV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eStrømforbruk på backplane\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e112 milliampere ved +5 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallasjons- og ingeniørveiledning\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMontering i chassis:\u003c\/strong\u003e Før det 1,81 kg tunge modulen inn i målsporet på Series 90-70-backplane. Fest topp- og bunnskruene godt for å etablere umiddelbar chassisjord og beskytte mot omgivende EMI-forstyrrelser.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eValg av signalfilter:\u003c\/strong\u003e Planlegg feltlinjene dine i henhold til nødvendige responsparametere. Bruk enkeltended-konfigurasjoner for stabile, langsommere innganger som benytter 41 Hz maskinvarefilter, eller velg differensialruting for å bruke 82 Hz responsfilter for områder med mye støy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKonfigurasjonsmetoder:\u003c\/strong\u003e Parametere som valg av område, aktive moduser og skanneparametere initialiseres via MS-DOS-konfigurasjonsverktøy eller Logicmaster-programvare. Alle variabelsett lagres automatisk i CPU-ens ikke-flyktige EEPROM-minne. Merk at selv om en håndholdt programmerer kan håndtere grunnleggende modusjusteringer, kan den ikke endre aktive skannede kanalsekvenser.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: I hvilket digitalt format returnerer modulen rådata til PLC-prosessoren?\u003c\/strong\u003e\u003cbr\u003e\nA1: Kortet koder alle digitaliserte spenningsmålinger i standard 2-komplementformat, som kartlegges direkte som et 16-bits WORD inn i CPU-minnetabellen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Hvordan håndterer modulen feildiagnostikk og overvåking av driftstilstand?\u003c\/strong\u003e\u003cbr\u003e\nA2: Kortet rapporterer kontinuerlig dedikerte statusbiter tilbake til CPU-en under hver I\/O-skanningssløyfe. Disse bitene gir sanntidsdiagnostikk angående maskinvarens integritet og konfigurasjoner utenfor rekkevidde.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Tilhører denne modulen Series 90-30 eller Series 90-70-serien?\u003c\/strong\u003e\u003cbr\u003e\nA3: IC697ALG321 tilhører strengt tatt høyytelsesfamilien Series 90-70 PLC-chassis, selv om den grensesnittet bruker de standard Logicmaster-konfigurasjonsverktøyene som deles av andre GE-legacy-systemer.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731077764,"sku":"IC697ALG321","price":146.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697ALG321.jpg?v=1781619193"},{"product_id":"ge-fanuc-ic200alg263-15-channel-voltage-input-module","title":"GE Fanuc IC200ALG263 15-Channel Voltage Input Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200ALG263 – 15-Channel Voltage Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #1976d2;\"\u003e15 single-ended channels\u003c\/span\u003e capture -10V to +10V signals at \u003cspan style=\"color: #1976d2;\"\u003e7.5ms speed\u003c\/span\u003e. Built-in diagnostics prevent data errors. Backplane-powered design eliminates extra wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCritical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003eIC200ALG263\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 15 Single-Ended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e -10V to +10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e ±15 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 7.5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 100kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1500V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 5V\/150mA from Backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -25°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL, CE, IEC 61131\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the update speed?\u003c\/strong\u003e This module updates all 15 channels every 7.5 milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is it powered?\u003c\/strong\u003e The \u003cstrong style=\"color: #d35400;\"\u003eIC200ALG263\u003c\/strong\u003e draws 5V power directly from the VersaMax backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat cables should I use?\u003c\/strong\u003e Shielded twisted-pair cables are recommended for noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEmail: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDocumentation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/product-data-sheet-VersaMax_Modular_I-O_and_Control.pdf?v=1745566907\" target=\"_blank\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731143300,"sku":"IC200ALG263","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200ALG263.jpg?v=1765104023"},{"product_id":"ic693alg220-high-precision-analog-input-ge-fanuc-series-90-30","title":"IC693ALG220 Høy presisjon analog inngang GE Fanuc Serie 90-30","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eGE Fanuc IC693ALG220 Analog spenningsinngangsmodul\u003c\/h2\u003e\n\n\u003ch3\u003eProduktoversikt\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color:#2c6e9e;\"\u003eIC693ALG220\u003c\/strong\u003e er en 4-kanals analog spenningsinngangsmodul for GE Fanuc Series 90-30 PLS-systemer. Gir presise spenningsmålinger fra -10 til +10 volt. Fabrikkalibrert for forbedret nøyaktighet. Modulvekt 0,45 kg.\u003c\/p\u003e\n\n\u003ch3\u003eTekniske spesifikasjoner\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eVerdi\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSpenningområde\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e-10 til +10 volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eKalibrering\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eFabrikkalibrert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eOppdateringshastighet\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e4 ms (alle 4 kanaler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eOppløsning\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e5 mV (1 LSB = 5 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eAbsolutt nøyaktighet (typisk)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e±10 mV over driftstemperatur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eAbsolutt nøyaktighet (maksimum)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e±30 mV over driftstemperatur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eLinearitet\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMindre enn 1 LSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eIsolasjon\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e1500 volt isolasjon fra felt- til logikkside\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eKrysskanalavvisning\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMer enn 80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eInngangsimpedans (spenningsmodus)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMer enn 9 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eInngangsimpedans (strømmodus)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eInngangsfilterrespons\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e17 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eIntern strøm (+5V buss)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e27 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eIntern strøm (+24V isolert buss)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e98 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eVekt\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0,45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eNøkkelfunksjoner\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 analoge inngangskanaler\u003c\/li\u003e\n\u003cli\u003e-10 til +10 volt inngangsområde\u003c\/li\u003e\n\u003cli\u003eFabrikkalibrert for forbedret nøyaktighet\u003c\/li\u003e\n\u003cli\u003e4 ms oppdateringshastighet for alle kanaler\u003c\/li\u003e\n\u003cli\u003e5 mV oppløsning\u003c\/li\u003e\n\u003cli\u003e1500 volt isolasjon fra felt- til logikkside\u003c\/li\u003e\n\u003cli\u003eMer enn 80 dB krysskanalavvisning\u003c\/li\u003e\n\u003cli\u003e17 Hz inngangsfilterrespons for optimal signal kvalitet\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKompatible systemer\u003c\/h3\u003e\n\u003cp\u003eGE Fanuc Series 90-30 PLS-systemer inkludert CPU311, CPU313, CPU323, CPU331, CPU340, CPU341, CPU350, CPU351, CPU352, CPU360, CPU363 og kompatible 90-30 ekspansjonsrack.\u003c\/p\u003e\n\n\u003ch3\u003eOfte stilte spørsmål\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Hva er spenningsmåleområdet til IC693ALG220?\u003c\/strong\u003e\u003cbr\u003eA1: Modulen måler -10 til +10 volt DC med 5 mV oppløsning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Hvor rask er oppdateringshastigheten?\u003c\/strong\u003e\u003cbr\u003eA2: 4 millisekunder for alle fire kanaler samtidig.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Hvilken isolasjon gir denne modulen?\u003c\/strong\u003e\u003cbr\u003eA3: 1500 volt isolasjon mellom felt- og logikksiden for pålitelig drift i industrielle miljøer.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731176068,"sku":"IC693ALG220","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693ALG220-1.jpg?v=1781100069"},{"product_id":"ic695alg106-ge-fanuc-rx3i-6-channel-analog-input-module","title":"IC695ALG106 GE Fanuc RX3i 6-Channel Analog Input Module","description":"\u003ch3\u003eGE Fanuc IC695ALG106 RX3i 6-Channel Isolated Analog Input Module\u003c\/h3\u003e\n\u003cp\u003eGE Fanuc \u003cstrong\u003eIC695ALG106\u003c\/strong\u003e is a 6-channel isolated analog input module for PACSystem RX3i. It accepts voltage and current signals with 16-bit resolution and configurable filtering.\u003c\/p\u003e\n\u003ch4\u003eKey Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc \/ Emerson Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC695ALG106\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystem RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 6 individually isolated inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit ADC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData format:\u003c\/strong\u003e IEEE 32-bit floating point or 16-bit integer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan time:\u003c\/strong\u003e 1 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.35 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower input:\u003c\/strong\u003e 24 VDC isolated external source\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration accuracy:\u003c\/strong\u003e 0.1% at 25°C, 0.2% full range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage protection:\u003c\/strong\u003e ±35 VDC continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent protection:\u003c\/strong\u003e ±35 mA continuous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInput Signal Ranges\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e ±10V, 0-10V, ±5V, 0-5V, 1-5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 0-20 mA, 4-20 mA, ±20 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFilter Options \u0026amp; Settling Times\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Hz filter:\u003c\/strong\u003e 127 ms settling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 Hz filter:\u003c\/strong\u003e 67 ms settling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Hz filter:\u003c\/strong\u003e 56 ms settling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40 Hz filter:\u003c\/strong\u003e 21 ms settling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 Hz filter:\u003c\/strong\u003e 3.1 ms settling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000 Hz filter:\u003c\/strong\u003e 0 ms settling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane 5V:\u003c\/strong\u003e 230 mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane 3.3V:\u003c\/strong\u003e 320 mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal isolated supply:\u003c\/strong\u003e 500 mA @ 19.2-30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temp:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temp:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many channels?\u003c\/strong\u003e\u003cbr\u003e6 individually isolated analog inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat signals are supported?\u003c\/strong\u003e\u003cbr\u003e±10V, 0-10V, ±5V, 0-5V, 1-5V, 0-20mA, 4-20mA, ±20mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat software is needed?\u003c\/strong\u003e\u003cbr\u003eProficy Machine Edition v5.6 SP11 or later.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731208836,"sku":"IC695ALG106","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695ALG106-1.jpg?v=1772633752"},{"product_id":"ge-fanuc-ic694mdr390-2a-relay-output-module","title":"GE Fanuc IC694MDR390 2A Relay Output Module","description":"\u003ch2\u003eGE Fanuc IC694MDR390 Input Output Module for RX3i PacSystem PLCs\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDR390\u003c\/strong\u003e is a mixed input\/output module for the RX3i PacSystem series. It combines 8 discrete inputs with 8 relay outputs in a single module, providing flexible I\/O expansion for industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eInput Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e8 individually isolated sinking\/sourcing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 5 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Current:\u003c\/strong\u003e 7.5 mA per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Response Time:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e7.5 milliseconds On\/Off\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Between Inputs:\u003c\/strong\u003e 500 VAC RMS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutput Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e2 groups of 4 Normally Open relay outputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 5 to 30 VDC or 5 to 250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Current per Output:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e2.0 Amps Max\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Response Time:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e15 milliseconds On\/Off\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Capacity:\u003c\/strong\u003e 5.0 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Output Load:\u003c\/strong\u003e 10 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Between Outputs:\u003c\/strong\u003e 500 VAC RMS per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Operating Frequency:\u003c\/strong\u003e 50 to 60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731274372,"sku":"IC694MDR390","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDR390.jpg?v=1774340848"},{"product_id":"ic200alg432-ge-fanuc-high-speed-mixed-module","title":"IC200ALG432 GE Fanuc High-Speed Mixed Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200ALG432 VersaMax Mixed Analog Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200ALG432\u003c\/strong\u003e is a VersaMax mixed analog module. It features fast update rates for control applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86c1;\"\u003eGE Fanuc IC200ALG432\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bits (8 counts).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 0.4 milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 5 milliseconds input filter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.3% of full scale at 25°C, ±1% maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 160 mA (including load).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 10 VDC supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Voltage:\u003c\/strong\u003e 0 Volts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate speed?\u003c\/strong\u003e The \u003cstrong\u003eIC200ALG432\u003c\/strong\u003e has a 0.4 ms update rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy rating?\u003c\/strong\u003e ±0.3% at 25°C, ±1% maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule weight?\u003c\/strong\u003e 200 grams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor quotes and support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731307140,"sku":"IC200ALG432","price":142.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200ALG432.jpg?v=1765713055"},{"product_id":"ic200alg430-ge-fanuc-mixed-analog-i-o-module","title":"IC200ALG430 GE Fanuc Mixed Analog I\/O Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200ALG430 VersaMax Combination Analog Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200ALG430\u003c\/strong\u003e is a VersaMax combination analog module. It has 4 analog inputs and 2 analog outputs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86c1;\"\u003eGE Fanuc IC200ALG430\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 4 differential channels, 4-20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 2 single-ended channels, 4-20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bits for all channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e Inputs 0.4 ms, Outputs 0.3 ms maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.3% typical, ±1% maximum at 0-60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter:\u003c\/strong\u003e 5.0 ms input filter response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Inputs: none external. Outputs: 18-30 VDC or 9.6-15 VDC external.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 50 mA at 5VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC continuous, 1500 VAC for 1 minute.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLEDs:\u003c\/strong\u003e FLD POWER and MODULE OK indicators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-slot VersaMax module.\u003c\/li\u003e\n\u003cli\u003eExternal power required only for output circuits.\u003c\/li\u003e\n\u003cli\u003eWiring: Inputs differential, outputs single-ended.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel configuration?\u003c\/strong\u003e The \u003cstrong\u003eIC200ALG430\u003c\/strong\u003e has 4 input and 2 output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal type?\u003c\/strong\u003e All channels use 4-20 mA signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule weight?\u003c\/strong\u003e 200 grams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor quotes and support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731372676,"sku":"IC200ALG430","price":122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200ALG430-3.jpg?v=1765704472"},{"product_id":"ic694alg391-output-module-ge-fanuc-0-20ma-4-20ma","title":"IC694ALG391 Output Module | GE Fanuc 0-20mA 4-20mA","description":"\u003ch2\u003eGE Fanuc IC694ALG391 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ALG391\u003c\/strong\u003e is a 2-channel analog output module for RX3i PacSystems series. Delivers precise current outputs with 12-bit resolution.\u003c\/p\u003e\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e IC694ALG391\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX3i PacSystems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel count:\u003c\/strong\u003e 2 isolated outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bits (4,096 steps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ranges:\u003c\/strong\u003e 0-20mA and 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate rate:\u003c\/strong\u003e ≤100 µs per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 1.8W nominal, 2.5W max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e 500,000 hours at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShelf life:\u003c\/strong\u003e 12 months from manufacture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 120 × 40 × 105 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 g (0.2 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 500V DC channel-to-backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane compatibility:\u003c\/strong\u003e Series 90-30 \u0026amp; RX3i serial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indication:\u003c\/strong\u003e Green \"Module OK\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output ranges are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e0-20mA and 4-20mA current outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the resolution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e12 bits (4,096 steps) for precise control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support hot swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Power down system before installation or removal.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731405444,"sku":"IC694ALG391","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694ALG391-1.jpg?v=1774169363"},{"product_id":"versamax-ic200alg331-analog-output-ge-fanuc","title":"VersaMax IC200ALG331 Analog Output - GE Fanuc","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200ALG331 VersaMax Analog Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200ALG331\u003c\/strong\u003e is a VersaMax analog output module. It has 4 individually isolated output channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86c1;\"\u003eGE Fanuc IC200ALG331\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 4 individually isolated outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e ±10 VDC or 4-20 mA (software configurable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16 bits (381 µV nominal voltage, 381 nA nominal current).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% maximum full scale at 25°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 7 ms maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 18-30 VDC external.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 10 mA at 5VDC, 115 mA at 3.3V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC continuous, 1500 VAC for 1 minute (channel to ground).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLEDs:\u003c\/strong\u003e FLD PWR and OK indicators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-slot VersaMax module.\u003c\/li\u003e\n\u003cli\u003eExternal 18-30 VDC power supply required.\u003c\/li\u003e\n\u003cli\u003eFully software configurable - no jumpers needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel count?\u003c\/strong\u003e The \u003cstrong\u003eIC200ALG331\u003c\/strong\u003e has 4 isolated output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput types?\u003c\/strong\u003e Software selectable ±10 VDC or 4-20 mA per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule weight?\u003c\/strong\u003e 200 grams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor quotes and support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731536516,"sku":"IC200ALG331","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200ALG331-2.jpg?v=1765704222"},{"product_id":"ic694alg392-output-module-ge-fanuc-8ms","title":"IC694ALG392 Output Module | GE Fanuc 8ms","description":"\u003ch2\u003eGE Fanuc IC694ALG392 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ALG392\u003c\/strong\u003e is an analog output module for RX3i PacSystems series. Features 1-8 single-ended user-selectable channels. High MTBF of 600,000 hours at 25°C with 8ms update interval per channel.\u003c\/p\u003e\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e IC694ALG392\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX3i PacSystems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 1-8 single-ended, user-selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate interval:\u003c\/strong\u003e 8 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory calibration:\u003c\/strong\u003e ±0.625 µA (current), ±0.3125 mV (voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e 600,000 hours at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up time:\u003c\/strong\u003e ≤50 ms after power-on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500V DC channel-to-backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShelf life:\u003c\/strong\u003e 12 months from manufacture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical \u0026amp; environmental\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 120 × 40 × 105 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 210 g (0.21 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity tolerance:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 5g, 10-500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e 30g, 11 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow many channels are configurable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1 to 8 single-ended channels, user-selectable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the update interval?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e8 ms per channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the MTBF rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e600,000 hours at 25°C.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731569284,"sku":"IC694ALG392","price":217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694ALG392-1.jpg?v=1774169693"},{"product_id":"hart-5-0-module-ic695alg728-ge-rx3i-8-channel-analog-output","title":"HART 5.0 Module IC695ALG728 | GE RX3i 8 Channel Analog Output","description":"\u003ch2\u003eGeneral Electric IC695ALG728 PACSystem RX3i Analog Output Module with HART 8 Channels\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IC695ALG728\u003c\/strong\u003e is a PACSystem RX3i analog output module with 8 non-isolated channels. Supports HART protocol version 5.0. Outputs: +\/-10V, 0-10V, 0-20mA, 4-20mA. Resolution up to 15.9 bits. \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number: \u003cspan style=\"color: #2980b9;\"\u003eIC695ALG728\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eBrand: \u003cspan style=\"color: #2980b9;\"\u003eGeneral Electric (GE Fanuc \/ Emerson)\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eSeries: \u003cspan style=\"color: #2980b9;\"\u003ePACSystem RX3i\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eChannels: \u003cspan style=\"color: #2980b9;\"\u003e8 non-isolated\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eHART Protocol: \u003cspan style=\"color: #2980b9;\"\u003eVersion 5.0 supported, 2 modems, 4 outputs per modem\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eVoltage Output: \u003cspan style=\"color: #2980b9;\"\u003e+\/-10V, 0-10V DC\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eCurrent Output: \u003cspan style=\"color: #2980b9;\"\u003e0-20mA, 4-20mA\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eResolution: \u003cspan style=\"color: #2980b9;\"\u003e+\/-10V: 15.9 bits, 0-10V: 14.9 bits, 0-20mA: 15.9 bits, 4-20mA: 15.6 bits\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eOutput Load: \u003cspan style=\"color: #2980b9;\"\u003e850 Ohms max\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eUpdate Rate: \u003cspan style=\"color: #2980b9;\"\u003e8ms without HART, 16ms with HART\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eSettling Time: \u003cspan style=\"color: #2980b9;\"\u003eVoltage: 2ms (0-95%), Current: 23ms without HART, 70ms with HART\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eAccuracy: \u003cspan style=\"color: #2980b9;\"\u003e0.15% at 25°C, 0.30% at 60°C\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: \u003cspan style=\"color: #2980b9;\"\u003e2550V DC for 1 second\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eBackplane Power: \u003cspan style=\"color: #2980b9;\"\u003e380mA max at 3.3V (with HART enabled)\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003ePower Consumption: \u003cspan style=\"color: #2980b9;\"\u003e375mA at 3.3V, 315mA at 24V isolated\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003ePower Dissipation: \u003cspan style=\"color: #2980b9;\"\u003e7.25W max\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eExternal Supply: \u003cspan style=\"color: #2980b9;\"\u003e19.2-30V DC (24V nominal), 250mA max, 190mA typical\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eOutput Protection: \u003cspan style=\"color: #2980b9;\"\u003e-30V for 60s, +30V for 1 hour (current output only)\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eData Format: \u003cspan style=\"color: #2980b9;\"\u003eIEEE 32-bit float or 16-bit integer in 32-bit field\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eMounting: \u003cspan style=\"color: #2980b9;\"\u003eSingle slot, local or distributed RX3i rack\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eWeight: \u003cspan style=\"color: #2980b9;\"\u003e0.3 kg\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003eHow many channels on \u003cstrong\u003eIC695ALG728\u003c\/strong\u003e?\u003c\/h3\u003e\n\u003cp\u003e8 non-isolated analog output channels with HART 5.0 support, 2 modems with 4 outputs each.\u003c\/p\u003e\n\u003ch3\u003eWhat output signals and update rates?\u003c\/h3\u003e\n\u003cp\u003e+\/-10V, 0-10V, 0-20mA, 4-20mA with 14.9-15.9 bit resolution. Update rate 8ms without HART, 16ms with HART.\u003c\/p\u003e\n\u003ch3\u003eWhat is the weight and power requirement?\u003c\/h3\u003e\n\u003cp\u003e0.3 kg, requires 380mA at 3.3V backplane, 315mA at 24V isolated, external 19.2-30V at 250mA max.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731602052,"sku":"IC695ALG728","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695ALG728-2.jpg?v=1772804536"},{"product_id":"ic200alg326-ge-fanuc-plc-current-output-module","title":"IC200ALG326 GE Fanuc PLC Current Output Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200ALG326 VersaMax Analog Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200ALG326\u003c\/strong\u003e is a VersaMax analog output module. It has 8 single-ended current output channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86c1;\"\u003eGE Fanuc IC200ALG326\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 single-ended current outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 4-20 mA (default), 0-20 mA (jumper configurable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 15 bits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 15 ms maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 18 to 30 VDC external.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 50 mA max at 5V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC continuous, 1500 VAC for 1 minute.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLEDs:\u003c\/strong\u003e 2 status indicators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-slot VersaMax module.\u003c\/li\u003e\n\u003cli\u003eExternal 18-30 VDC power supply required.\u003c\/li\u003e\n\u003cli\u003eOutput default is configurable via jumper.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel count?\u003c\/strong\u003e The \u003cstrong\u003eIC200ALG326\u003c\/strong\u003e has 8 current output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput range?\u003c\/strong\u003e 4-20 mA default, configurable to 0-20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate speed?\u003c\/strong\u003e 15 milliseconds maximum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor quotes and support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050731634820,"sku":"IC200ALG326","price":151.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200ALG326-2.jpg?v=1765702278"},{"product_id":"ge-fanuc-90-30-extended-backup-battery-pack-ic693acc302","title":"GE Fanuc 90-30 Extended Backup Battery Pack IC693ACC302","description":"\u003ch2\u003eGE Fanuc IC693ACC302 Series 90-30 Auxiliary Battery Pack\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc \u003cstrong style=\"color: #2e86c1;\"\u003eIC693ACC302\u003c\/strong\u003e is an auxiliary battery pack that extends memory backup for Series 90-30\/90-70 PLCs. It provides reliable RAM retention during power interruptions.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtends memory backup time for critical PLC applications\u003c\/li\u003e\n\u003cli\u003eCompatible with Series 90-30, 90-70, and PACSystems controllers\u003c\/li\u003e\n\u003cli\u003ePanel-mounted design with secure screw installation\u003c\/li\u003e\n\u003cli\u003eFlame-retardant ABS plastic case for safety\u003c\/li\u003e\n\u003cli\u003eIncludes built-in 1-Amp fuse for circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e GE Fanuc \u003cstrong\u003eIC693ACC302\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e \u003cstrong style=\"color: #27ae60;\"\u003e3 Volts DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 15 Ampere-hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup Time:\u003c\/strong\u003e Up to 75 months (CPUs 311-364)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU 374 Backup:\u003c\/strong\u003e 15 months maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShelf Life:\u003c\/strong\u003e 7 years from manufacture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C (32 to 140°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 145.1 × 65 × 39.9 mm (5.7 × 2.5 × 1.5 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Material:\u003c\/strong\u003e Black flame-retardant ABS plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 0.6 m (2 ft) 24 AWG red\/black twisted pair\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Female 2-pin for secure connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Four #8-32 × ½\" flat head screws required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIC693 power supply units\u003c\/li\u003e\n\u003cli\u003eIC693 CPUs models 311-364\u003c\/li\u003e\n\u003cli\u003eIC693 CPU model 374\u003c\/li\u003e\n\u003cli\u003eAll existing IC697 CPUs\u003c\/li\u003e\n\u003cli\u003eSeries 90-30 and 90-70 controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes battery pack and connection cable\u003c\/li\u003e\n\u003cli\u003eShips via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhat is the maximum backup time provided?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIC693ACC302\u003c\/strong\u003e provides up to \u003cstrong style=\"color: #27ae60;\"\u003e75 months\u003c\/strong\u003e backup with compatible CPUs (311-364 series).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhich PLC systems support this battery?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with GE Fanuc Series 90-30, 90-70, PACSystems, and IC693\/IC697 controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow is the battery pack installed?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePanel-mount using four #8-32 screws and connect via the 2-pin connector to the PLC's battery port.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050733142148,"sku":"IC693ACC302","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693ACC302-3.jpg?v=1768023762"},{"product_id":"rx3i-ic695acc302-15ah-lithium-battery-backup-ge","title":"RX3i IC695ACC302 15AH Lithium Battery Backup GE","description":"\u003ch3\u003eGE Fanuc IC695ACC302 Auxiliary Smart Battery Module\u003c\/h3\u003e\n\u003cp\u003eGE Fanuc \u003cstrong\u003eIC695ACC302\u003c\/strong\u003e provides extended RAM backup for PACSystem RX3i and RX7i CPUs with 15AH lithium battery capacity.\u003c\/p\u003e\n\u003ch4\u003eKey Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC695ACC302\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible:\u003c\/strong\u003e RX3i \/ RX7i PACSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 3-Cell Lithium\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 3 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 15.0 AH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLithium:\u003c\/strong\u003e 5.1 grams total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 224 grams\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temp:\u003c\/strong\u003e 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShelf life:\u003c\/strong\u003e 7 years at 20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 5.713\" x 2.559\" x 1.571\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e CE Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConnector Details\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 2.0 ft (0.6m) twisted 22 AWG, 80°C rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Female 4-pin JAE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdapter:\u003c\/strong\u003e 2\" (50mm) 4-pin male to 2-pin female included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity?\u003c\/strong\u003e\u003cbr\u003e15.0 AH at 3VDC output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow long does it last?\u003c\/strong\u003e\u003cbr\u003e23-200 days depending on CPU model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen to install?\u003c\/strong\u003e\u003cbr\u003eInstall with CPU powered on for maximum life.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050733174916,"sku":"IC695ACC302","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695ACC302.jpg?v=1772546057"},{"product_id":"ge-fanuc-ic687bem713-rx7i-bus-transmitter-fip-redundancy","title":"GE Fanuc IC687BEM713 Rx7i Bus Transmitter FIP Redundancy","description":"\u003ch2\u003e\u003cstrong\u003eProduct overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc — \u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #b22222;\"\u003eIC687BEM713\u003c\/strong\u003e — \u003cstrong\u003eSeries:\u003c\/strong\u003e Rx7i PACsystem\u003c\/li\u003e\n\u003cli\u003eBus transmitter module for FIP redundant systems\u003c\/li\u003e\n\u003cli\u003eRequires 2 modules per complete redundant system\u003c\/li\u003e\n\u003cli\u003eInstalls in dual backplane redundancy rack — uses 1 VME slot\u003c\/li\u003e\n\u003cli\u003eNet weight: 0.3 kg (0.66 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eElectrical specs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBus voltage: 5 Volts — Current draw: 1.4 Amps\u003c\/li\u003e\n\u003cli\u003eNo DIP switches — software configuration only\u003c\/li\u003e\n\u003cli\u003eParallel programmer interface for high performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 built-in connectors: top for programmer, bottom for RCM\u003c\/li\u003e\n\u003cli\u003eMechanical keying prevents incorrect installation\u003c\/li\u003e\n\u003cli\u003eConnects directly to redundancy communications module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eRedundancy design\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEach rack half needs one \u003cstrong\u003eIC687BEM713\u003c\/strong\u003e plus one RCM\u003c\/li\u003e\n\u003cli\u003eEnables FIP redundancy for fault-tolerant systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackage contents\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC687BEM713\u003c\/strong\u003e bus transmitter module\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many modules per FIP system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: FIP redundant system needs exactly 2 bus transmitter modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Any switches to set?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No — configure everything through software, no DIP switches.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does bottom connector do?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It connects to redundancy communications module (RCM).\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050791370884,"sku":"IC687BEM713","price":201.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC687BEM713-1.jpg?v=1772025572"},{"product_id":"ic693cbk001-ge-fanuc-high-density-3m-plc-wiring-cables","title":"IC693CBK001 GE Fanuc High-Density 3m PLC Wiring Cables","description":"\u003ch2 style=\"color: #1A237E; font-size: 22px; font-weight: bold; margin-bottom: 12px;\"\u003eGE Fanuc IC693CBK001 Cable Kit\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  The \u003cstrong style=\"color: #0D47A1;\"\u003e\u003cspan style=\"color: #0D47A1;\"\u003eGE Fanuc IC693CBK001\u003c\/span\u003e\u003c\/strong\u003e is a high-density, pre-wired cable kit designed for connecting Series 90-30 high-density PLC I\/O modules to external terminal blocks. Featuring two heavy-duty, 3-meter right-angle cables, this kit ensures stable electrical connections and clean routing within industrial enclosures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eKey Advantages\u003c\/h3\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Cable Match:\u003c\/strong\u003e Includes both IC693CBL327 and IC693CBL328 cables for complete high-density module wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpace-Saving Profile:\u003c\/strong\u003e Molded right-angle headers allow tight bend radius execution in dense electrical cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Conductors:\u003c\/strong\u003e Industrial-grade 22 AWG solid copper wire supports stable signal integrity across longer runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; color: #333333; margin-bottom: 15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0; width: 40%;\"\u003eCables Contained\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eIC693CBL327 \u0026amp; IC693CBL328 (Identical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eConnector Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eFujitsu FCN-365S024-AU (24-pin per end)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e3 Meters (10 feet) length \/ 35 x 8 x 2 cm packing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eElectrical Ratings\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e300 V DC\/AC peak voltage \/ 1.2 A per conductor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eCable Construction\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e22 AWG solid copper \/ UL 94V-0 fire-rated insulation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eEnvironment \u0026amp; Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e-20°C to +60°C operating \/ 220 g (0.48 lb) per cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eQuick Installation\u003c\/h3\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Interface:\u003c\/strong\u003e Align the 24-pin Fujitsu female connector to the male faceplate pins on the high-density module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Direction:\u003c\/strong\u003e Orient the right-angle cable exit downward to reduce strain on the faceplate assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block Link:\u003c\/strong\u003e Route the opposite end of the 3-meter harness directly to your remote DIN-rail terminal panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ1: What specific modules require this cable combination?\u003c\/strong\u003e\u003cbr\u003e\n  A1: This kit provides connectivity for 32-point high-density discrete modules (such as IC693MDL655 and similar cards) requiring dual Fujitsu port links.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ2: Can individual conductors handle full PLC group currents?\u003c\/strong\u003e\u003cbr\u003e\n  A2: Each conductor is rated for 1.2 Amps maximum. Total current summing across the card must respect individual module group tolerances.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ3: Is this kit suitable for deployment in high-temperature settings?\u003c\/strong\u003e\u003cbr\u003e\n  A3: Yes, the heavy-duty composition and UL 94V-0 rated insulation run safely across an industrial operating span from -20°C to +60°C.\n\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050791501956,"sku":"IC693CBK001","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693CBK001.jpg?v=1781883629"},{"product_id":"ge-fanuc-ic200cmm020-serial-module","title":"GE Fanuc IC200CMM020 Serial Module","description":"\u003ch2\u003eGE Fanuc Versamax \u003cstrong\u003eIC200CMM020\u003c\/strong\u003e Serial Communication Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200CMM020\u003c\/strong\u003e is a serial communication module from the GE Fanuc Versamax series. This module functions as a \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eModbus master module\u003c\/span\u003e and interfaces with slave devices including controllers, readers, and VFDs. It features both \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eRS-232 and RS-485 ports\u003c\/span\u003e for versatile connectivity.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eSerial communication module\u003c\/span\u003e for Versamax systems\u003c\/li\u003e\n\u003cli\u003eFunctions as \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eModbus master\u003c\/span\u003e with Genius NIU configuration\u003c\/li\u003e\n\u003cli\u003eConnects up to \u003cspan style=\"color: #3498db;\"\u003e2 I\/O stations\u003c\/span\u003e simultaneously\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003eRS-232 port\u003c\/span\u003e and \u003cspan style=\"color: #2e8b57;\"\u003eRS-485 port\u003c\/span\u003e with 15-pin D-type connector\u003c\/li\u003e\n\u003cli\u003eSupports baud rates: \u003cspan style=\"color: #3498db;\"\u003e1200, 2400, 4800, 9600, 19200\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003eFull and half duplex\u003c\/span\u003e operation\u003c\/li\u003e\n\u003cli\u003eCompact design: \u003cspan style=\"color: #2e8b57;\"\u003e4.3 x 2.63 x 1.956 inches\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3498db;\"\u003eLED indicators\u003c\/span\u003e on front for operation status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eIC200CMM020\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription:\u003c\/strong\u003e Serial communication module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eRS-232, RS-485\u003c\/span\u003e (15-pin D-type)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStations Supported:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e2 I\/O stations\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e1200, 2400, 4800, 9600, 19200\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e460mA @ 5V\u003c\/span\u003e, 5mA @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e4.3 x 2.63 x 1.956 inches\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Generic COMM programmer device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArchitecture:\u003c\/strong\u003e Open, indoor use only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x GE Fanuc \u003cstrong\u003eIC200CMM020\u003c\/strong\u003e serial communication module\u003c\/li\u003e\n\u003cli\u003e1x installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eFedEx, UPS, DHL\u003c\/span\u003e express worldwide\u003c\/li\u003e\n\u003cli\u003eShips within \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e24 hours\u003c\/span\u003e from stock\u003c\/li\u003e\n\u003cli\u003eGround shipping available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the part number for this communication module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number is \u003cstrong style=\"color: #c41e3a;\"\u003eIC200CMM020\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What communication ports does the \u003cstrong\u003eIC200CMM020\u003c\/strong\u003e have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt features \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eRS-232 and RS-485 ports\u003c\/span\u003e with a 15-pin D-type connector for the RS-485 interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. How many I\/O stations can this module connect to?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200CMM020\u003c\/strong\u003e can connect up to \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e2 I\/O stations\u003c\/span\u003e simultaneously.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050792550532,"sku":"IC200CMM020","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200CMM020-1.jpg?v=1771393156"},{"product_id":"ge-fanuc-ic697rcm711-redundancy-communications-module","title":"GE Fanuc IC697RCM711 Redundanskommunikasjonsmodul","description":"\u003ch2\u003eProduktoversikt\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc IC697RCM711\u003c\/strong\u003e er en enkeltspors Redundanskommunikasjonsmodul utviklet for høy-tilgjengelighet Series 90-70 PLC-systemer. Med en vekt på omtrent 0,68 kg (1,5 lbs) etablerer denne maskinvaremodulen en dedikert kommunikasjonslenke mellom primær- og backup-kontroller-rack for å synkronisere data og håndtere sømløse hot-standby-overganger. Den opererer på 5 VDC backplane-spenning og har fem aktive LED-indikatorer for sanntidsovervåking av status, noe som sikrer høy systemoppetid i kritiske prosesskontrollapplikasjoner.\u003c\/p\u003e\n\n\u003ch2\u003eKjernefordeler teknisk\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHøy tilgjengelighet med dobbel rack-synkronisering:\u003c\/strong\u003e Kontrollerer sanntidsredundans-håndtrykk mellom primær- og backup-prosessorer for å eliminere systemnedetid ved CPU-feil.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEffektivt strømforbruk på backplane:\u003c\/strong\u003e Trekker kun 0,7 ampere ved 5 VDC, noe som gir god strømreserve for høy-tetthets I\/O-konfigurasjoner i samme rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKlare visuelle diagnoser:\u003c\/strong\u003e Har 5 innebygde LED-indikatorer på frontpanelet for umiddelbar statusoppfølging og feilisolering for lokale ingeniørteam.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske spesifikasjoner\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpesifikasjonsdetaljer\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMerke \/ modellnummer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc \/ IC697RCM711\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBruttovekt\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0,68 kg (1,5 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eModultype \/ sporbredde\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eRedundanskommunikasjon \/ enkelt spor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBackplane-krav\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5 VDC driftsspenning \/ 0,7 ampere strømforbruk\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eSerielle grensesnittporter\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2 serielle porter (1 aktiv port via 9-pinners D-sub-kontakt \/ 1 port ubrukt)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eDatahastigheter og avstand\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e9600 bps overføringshastighet \/ maks 500 meter over RS-232 forbindelse\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eProgramvareintegrasjon\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eKobles til MS-DOS konfigurasjonsverktøy\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eChassis-kompatibilitet\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eStandard IC697 PLC-rack (Serie 90-70 systemer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBeskyttelsesgrad\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIP20 (Finger-sikker industriell kapsling)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eTemperaturprofil\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDrift: 0 til 60 °C (32 til 140 °F) \/ Lagring: -40 til 85 °C (-40 til 185 °F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallasjons- og ingeniørveiledning\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInnskubbing i spor:\u003c\/strong\u003e Juster det 0,68 kg tunge kortet med et enkelt åpent spor inne i IC697 PLC-racket. Press fast til modulen sitter godt i bakplanet, og stram festeskruene for å sikre en pålitelig jordingsvei.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSerielle tilkoblinger:\u003c\/strong\u003e Koble mastergrensesnittet via den 9-pinners D-sub serielle kontakten. Sørg for at punkt-til-punkt-skjermingen forblir intakt over den maksimale lengden på 500 meter for å opprettholde en ren 9600 bps-linje uten datatap.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMiljøvedlikehold:\u003c\/strong\u003e Sørg for at kjøleviftene i skapet gir tilstrekkelig luftstrøm rundt IP20-kabinettet for å holde temperaturen under 60 °C (140 °F), for å unngå ytelsesforringelse eller kommunikasjonsavbrudd.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske vanlige spørsmål\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Hvor mange serielle porter brukes aktivt på IC697RCM711-modulen?\u003c\/strong\u003e\u003cbr\u003e\nA1: Modulen har 2 serielle porter, men bare 1 port brukes til den aktive redundansdatakoblingen via den standard 9-pinners D-sub-kontakten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Hva viser de 5 integrerte LED-indikatorene på frontplaten?\u003c\/strong\u003e\u003cbr\u003e\nA2: De viser kritiske maskinvarediagnostikker, overvåker parametere som stabilitet i bakplanstrøm, portkommunikasjonsstatus og aktiv tildeling av rack-rolle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Kan denne maskinvaremodulen tåle fryselagerforhold under lagring?\u003c\/strong\u003e\u003cbr\u003e\nA3: Ja. Selv om driftsgrensen starter ved 0 °C, er enheten trygt vurdert til å tåle uoppvarmede lagertemperaturer så lave som -40 °C (-40 °F).\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050792616068,"sku":"IC697RCM711","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697RCM711.jpg?v=1781358519"},{"product_id":"ge-fanuc-ic695prs015-rx3i-pressure-transducer-module","title":"GE Fanuc | IC695PRS015 RX3i Pressure Transducer Module","description":"\u003ch2\u003eGE Fanuc IC695PRS015 PACSystems RX3i Pressure Transducer Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695PRS015\u003c\/strong\u003e is a pressure transducer module for PACSystems RX3i. It enables communication with up to 15 Honeywell smart pressure sensors. \u003c\/p\u003e\n\u003ch3\u003eCommunication Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePorts: 1 x RJ-45 (RS-485)\u003c\/li\u003e\n\u003cli\u003eCompatible Sensors: Honeywell (LG1237) smart pressure transducers\u003c\/li\u003e\n\u003cli\u003eMaximum Sensors: 15 per module\u003c\/li\u003e\n\u003cli\u003eBaud Rate: 375 kbaud\u003c\/li\u003e\n\u003cli\u003eMaximum Modules per CPU: 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower at 3.3 V DC: 0.7 A\u003c\/li\u003e\n\u003cli\u003ePower at 5 V DC: 0.115 A\u003c\/li\u003e\n\u003cli\u003eMaximum Overvoltage: ±25 V\u003c\/li\u003e\n\u003cli\u003eMinimum Channel to Channel Crosstalk: -55 dB\u003c\/li\u003e\n\u003cli\u003eSlots: 1 (single slot)\u003c\/li\u003e\n\u003cli\u003eBackplane Support: Universal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndependent, isolated serial ports\u003c\/li\u003e\n\u003cli\u003ePort to backplane isolation\u003c\/li\u003e\n\u003cli\u003eFlash memory for firmware upgrades\u003c\/li\u003e\n\u003cli\u003eHot insertion and hot removal support\u003c\/li\u003e\n\u003cli\u003eModule status, identity and fault reporting via LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: 0.3 kg (0.66 lb)\u003c\/li\u003e\n\u003cli\u003eCatalog: IC695\u003c\/li\u003e\n\u003cli\u003eSeries: PACSystems RX3i\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many Honeywell sensors can the IC695PRS015 connect to?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It connects up to 15 Honeywell smart pressure transducer sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many modules can be installed per CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Maximum of 4 pressure transducer modules per main CPU backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the module weight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003eIC695PRS015\u003c\/strong\u003e weighs 0.3 kg (0.66 lb).\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050792648836,"sku":"IC695PRS015","price":193.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695PRS015.jpg?v=1775137830"},{"product_id":"ge-fanuc-ic200chs025-versamax-carrier","title":"GE Fanuc IC200CHS025 VersaMax Carrier","description":"\u003ch2\u003eGE Fanuc Versamax \u003cstrong\u003eIC200CHS025\u003c\/strong\u003e Compact I\/O Carrier\u003c\/h2\u003e\n\u003cp\u003eCompact DIN rail carrier for \u003cspan style=\"color: #e74c3c; font-weight: bold;\"\u003evertical mounting\u003c\/span\u003e of Versamax modules. Features \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003espring-style terminals\u003c\/span\u003e for tool-free wiring connections in tight spaces.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC200CHS025\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e36 IEC spring-style\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Capacity:\u003c\/strong\u003e Single (\u003cspan style=\"color: #c41e3a;\"\u003e14-22 AWG\u003c\/span\u003e) \/ Dual (\u003cspan style=\"color: #2e8b57;\"\u003e18 AWG\u003c\/span\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e264V AC\u003c\/span\u003e (\u003cspan style=\"color: #2e8b57;\"\u003e300V AC transient\u003c\/span\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e163.5 × 66.8 × 70 mm\u003c\/span\u003e (L×W×H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e-40°C to 60°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cp\u003eMount on standard DIN rail with \u003cspan style=\"color: #27ae60; font-weight: bold;\"\u003e2\" vertical clearance\u003c\/span\u003e and \u003cspan style=\"color: #c41e3a;\"\u003e1\" horizontal space\u003c\/span\u003e for airflow. Carrier-to-carrier connectors enable easy expansion.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLatch holes for \u003cspan style=\"color: #c41e3a;\"\u003esecure module attachment\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eKeying dials prevent \u003cspan style=\"color: #2e8b57;\"\u003eincorrect module installation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e74c3c; font-weight: bold;\"\u003eHot-swappable\u003c\/span\u003e module replacement\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cspan style=\"color: #3498db;\"\u003e32 I\/O points\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCarrier-to-carrier \u003cspan style=\"color: #2e8b57;\"\u003emating connectors\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eWorks with all \u003cstrong\u003eVersamax I\/O modules\u003c\/strong\u003e designed for \u003cspan style=\"color: #27ae60; font-weight: bold;\"\u003evertical mounting\u003c\/span\u003e. Ideal for space-limited control panels.\u003c\/p\u003e\n\u003ch3\u003eSafety Certifications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #c41e3a;\"\u003eUL\u003c\/span\u003e, \u003cspan style=\"color: #2e8b57;\"\u003eCE\u003c\/span\u003e, \u003cspan style=\"color: #3498db;\"\u003ecUL\u003c\/span\u003e certified. Designed for reliable operation in industrial environments.\u003c\/p\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x GE Fanuc \u003cstrong\u003eIC200CHS025\u003c\/strong\u003e VersaMax compact I\/O carrier\u003c\/li\u003e\n\u003cli\u003eCarrier unit with spring terminals\u003c\/li\u003e\n\u003cli\u003eInstallation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eBacked by \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e1-year manufacturer warranty\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachine control cabinets\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #27ae60; font-weight: bold;\"\u003eCompact PLC systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eAssembly line automation\u003c\/li\u003e\n\u003cli\u003eHVAC control panels\u003c\/li\u003e\n\u003cli\u003eSpace-limited \u003cspan style=\"color: #c41e3a;\"\u003eindustrial control\u003c\/span\u003e applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Documentation\u003c\/h3\u003e\n\u003cp\u003e\u003ca style=\"background-color: #c41e3a; color: white; padding: 10px 20px; text-decoration: none; border-radius: 5px; display: inline-block; font-weight: bold;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/GE_Fanuc_Automation.pdf?v=1749464348\" target=\"_blank\"\u003e📥 Download Product Datasheet PDF\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eFedEx, UPS, DHL\u003c\/span\u003e express worldwide\u003c\/li\u003e\n\u003cli\u003eShips within \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e24 hours\u003c\/span\u003e from stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the part number for this carrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number is \u003cstrong style=\"color: #c41e3a;\"\u003eIC200CHS025\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What type of terminals does it have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt features \u003cstrong style=\"color: #3498db;\"\u003e36 IEC spring-style terminals\u003c\/strong\u003e for tool-free wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What is the operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe operating temperature range is \u003cstrong style=\"color: #2e8b57;\"\u003e-40°C to 60°C\u003c\/strong\u003e.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050792714372,"sku":"IC200CHS025","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200CHS025.jpg?v=1771335141"},{"product_id":"36-pin-i-o-carrier-ic200chs003-ge-fanuc","title":"36-Pin I\/O Carrier IC200CHS003 | GE Fanuc","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200CHS003 VersaMax Connector-Style I\/O Carrier\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200CHS003\u003c\/strong\u003e is a connector-style carrier for VersaMax I\/O modules. It uses a 36-pin connector for cable-based field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86c1;\"\u003eGE Fanuc IC200CHS003\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Connector-style I\/O carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 36-pin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.63 x 5.25 inches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (7.5x35 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Mounting:\u003c\/strong\u003e Vertical, perpendicular to DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 2 Amps per point, 8 Amps per power\/ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Up to 300 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility \u0026amp; Cabling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Cables:\u003c\/strong\u003e IC200CBL105 (0.5m), IC200CBL110 (1m), IC200CBL120 (2m), IC200CBL230 (3m).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Kit:\u003c\/strong\u003e IC200ACC304 for building custom cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncompatible Modules:\u003c\/strong\u003e IC200MDL144, IC200MDL244, IC200MDD850 (due to isolation requirements).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is wiring done?\u003c\/strong\u003e The \u003cstrong\u003eIC200CHS003\u003c\/strong\u003e uses pre-made cables (e.g., IC200CBL110) for field connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O module orientation?\u003c\/strong\u003e I\/O modules mount vertically on this carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule weight?\u003c\/strong\u003e 200 grams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor quotes and support: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050793107588,"sku":"IC200CHS003","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200CHS003-5.jpg?v=1765980602"},{"product_id":"ge-ic695cpk400-rx3i-rackless-cpu-1-2ghz","title":"GE IC695CPK400 RX3i Rackless CPU | 1.2GHz","description":"\u003ch2\u003eGE IC695CPK400 – RX3i Rackless CPU with Energy Pack\u003c\/h2\u003e\n\u003cp\u003eThe GE IC695CPK400 is a rackless, high-performance PACSystem RX3i controller with a 1.2 GHz AMD G Series quad-core processor and 64 MB storage. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: GE Fanuc\u003c\/li\u003e\n\u003cli\u003eSeries: RX3i PACSystem\u003c\/li\u003e\n\u003cli\u003ePart Number: IC695CPK400\u003c\/li\u003e\n\u003cli\u003eProcessor: 1.2 GHz AMD G Series Quad-Core\u003c\/li\u003e\n\u003cli\u003eRAM: 64 MB\u003c\/li\u003e\n\u003cli\u003eStorage: 64 MB\u003c\/li\u003e\n\u003cli\u003eEnergy Pack: Included\u003c\/li\u003e\n\u003cli\u003eWeight: 0.9 kg (2.0 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eI\/O capacity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDiscrete I\/O: 32K bits\u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: 32K words\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003eQ: What is the processor of IC695CPK400?\u003c\/p\u003e\n\u003cp\u003eA: 1.2 GHz AMD G Series quad-core.\u003c\/p\u003e\n\u003cp\u003eQ: How much memory does IC695CPK400 have?\u003c\/p\u003e\n\u003cp\u003eA: 64 MB RAM and 64 MB storage.\u003c\/p\u003e\n\u003cp\u003eQ: What is the weight of IC695CPK400?\u003c\/p\u003e\n\u003cp\u003eA: 0.9 kg (2.0 lbs).\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050793336964,"sku":"IC695CPK400","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695CPK400.jpg?v=1774873238"},{"product_id":"ic695pmm335-ge-fanuc-4-axis-motion-controller-module","title":"IC695PMM335 | GE Fanuc 4-Axis Motion Controller Module","description":"\u003ch2\u003eGeneral Electric IC695PMM335 PACSystems RX3i Motion Controller\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IC695PMM335\u003c\/strong\u003e is a multi-axis motion controller for PACSystems RX3i. It controls up to 4 servo axes plus virtual axes. Weight: 0.68 kg (1.5 lb).\u003c\/p\u003e\n\u003ch3\u003eMotion Control Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControlled Axes: Up to 4 servo axes\u003c\/li\u003e\n\u003cli\u003ePosition Loop Update Rate: 500 μs\u003c\/li\u003e\n\u003cli\u003eFSSB Velocity Loop: 125 μs\u003c\/li\u003e\n\u003cli\u003eFSSB Torque Loop: 62.5 μs\u003c\/li\u003e\n\u003cli\u003eMotion Path Planning: 1 ms\u003c\/li\u003e\n\u003cli\u003eMaximum Modules per Rack: 8 (up to 40 axes)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eServo Communication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterface: Fiber Optic FSSB\u003c\/li\u003e\n\u003cli\u003eCommunication Speed: 50 Mb\/s\u003c\/li\u003e\n\u003cli\u003eMax Cable Length: 100m between nodes, 400m per module\u003c\/li\u003e\n\u003cli\u003eEncoder Types: Incremental or Absolute Serial\u003c\/li\u003e\n\u003cli\u003eHigh Speed Position Capture: 2 inputs per axis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt-in I\/O\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral Purpose Inputs: 4 (24VDC, optically isolated)\u003c\/li\u003e\n\u003cli\u003eHigh-Speed Inputs: 2 (24VDC)\u003c\/li\u003e\n\u003cli\u003eGeneral Purpose I\/O: 2 (24VDC, optically isolated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower at 3.3V: 1.1 A\u003c\/li\u003e\n\u003cli\u003ePower at 5V: 0.45 A\u003c\/li\u003e\n\u003cli\u003eSlots: 1 (single slot)\u003c\/li\u003e\n\u003cli\u003eBackplane: Universal only\u003c\/li\u003e\n\u003cli\u003eWeight: 0.68 kg (1.5 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration: Proficy Machine Edition\u003c\/li\u003e\n\u003cli\u003eElectronic CAM profiles, Interrupt routines (3 per module)\u003c\/li\u003e\n\u003cli\u003eData logging, PLCopen compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many axes does the IC695PMM335 control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It controls up to 4 servo axes plus virtual axes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the position loop update rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The position loop updates every 500 μs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the module weight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003eIC695PMM335\u003c\/strong\u003e weighs 0.68 kg (1.5 lb).\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050793369732,"sku":"IC695PMM335","price":146.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695PMM335-1.jpg?v=1775136388"},{"product_id":"ge-ic695acc650-rx3i-pacsystem-conversion-rack-7-12-16-slot","title":"GE IC695ACC650 RX3i PacSystem Conversion Rack 7\/12\/16 Slot","description":"\u003ch3\u003eGE Fanuc IC695ACC650 RX3i Conversion Rack for Series 90-70 Systems\u003c\/h3\u003e\n\u003cp\u003eGE Fanuc \u003cstrong\u003eIC695ACC650\u003c\/strong\u003e is a conversion rack that bridges existing Series 90-70 systems to RX3i PACSystem architecture. It minimizes downtime during system upgrades.\u003c\/p\u003e\n\u003ch4\u003eKey Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC695ACC650\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX3i PacSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with:\u003c\/strong\u003e Series 90-70 systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane sizes:\u003c\/strong\u003e 7-slot, 12-slot, 16-slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.1 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting torque:\u003c\/strong\u003e 2.5 Nm (captive screws)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround lug:\u003c\/strong\u003e 12 AWG minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting orientation:\u003c\/strong\u003e Vertical or horizontal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat systems is this compatible with?\u003c\/strong\u003e\u003cbr\u003eExisting GE Series 90-70 systems migrating to RX3i.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat backplane sizes are supported?\u003c\/strong\u003e\u003cbr\u003e7-slot, 12-slot, and 16-slot backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the mounting torque?\u003c\/strong\u003e\u003cbr\u003e2.5 Nm for captive screws.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050794385540,"sku":"IC695ACC650","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695ACC650-1.jpg?v=1772632789"},{"product_id":"ic693acc317-ge-fanuc-series-90-30-plc-connection-accessory-kit","title":"IC693ACC317 GE Fanuc Series 90-30 PLC Connection Accessory Kit","description":"\u003ch2\u003eGE Fanuc IC693ACC317 Series 90-30 PLC Connector Kit\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc \u003cstrong style=\"color: #2e86c1;\"\u003eIC693ACC317\u003c\/strong\u003e is a connector kit for Series 90-30 PLC systems. This wiring kit provides essential connection components for reliable power and signal transmission in industrial automation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete connector kit for Series 90-30 PLC wiring\u003c\/li\u003e\n\u003cli\u003eAuto-ranging functionality - no jumper settings required\u003c\/li\u003e\n\u003cli\u003eCurrent-limiting protection against short circuits\u003c\/li\u003e\n\u003cli\u003eIncludes 24-pin I\/O connector and 25-pin D-type block\u003c\/li\u003e\n\u003cli\u003eCompatible with all GE Fanuc Series 90-30 CPU models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e GE Fanuc \u003cstrong\u003eIC693ACC317\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit Type:\u003c\/strong\u003e PLC connector kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e \u003cstrong style=\"color: #27ae60;\"\u003e24 Volts DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 24VDC (+10%, -20%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 7.5 mA average\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5 mA internal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e Yes - short circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Requirement:\u003c\/strong\u003e None - auto-ranging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKit Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24-pin I\/O connector for PLC interface\u003c\/li\u003e\n\u003cli\u003eConnection cable for machine\/drive interface\u003c\/li\u003e\n\u003cli\u003e25-pin D-type block connector for terminals\u003c\/li\u003e\n\u003cli\u003eSolder eyelet holder included\u003c\/li\u003e\n\u003cli\u003eRequires mated female 24-pin connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete connector kit with all components\u003c\/li\u003e\n\u003cli\u003eShips via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhat components are included in the IC693ACC317 kit?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIC693ACC317\u003c\/strong\u003e kit includes a 24-pin I\/O connector, connection cable, and 25-pin D-type block connector for complete PLC wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDoes this connector kit require jumper settings?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNo, the kit features \u003cstrong style=\"color: #27ae60;\"\u003eauto-ranging functionality\u003c\/strong\u003e and does not require any jumper configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat voltage does this connector kit support?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIt supports 24VDC operation with a voltage range of +10% to -20% from the nominal 24VDC rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050794516612,"sku":"IC693ACC317","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693ACC317.jpg?v=1768026012"},{"product_id":"ic697alg440-ge-fanuc-series-90-30-analog-input-card","title":"IC697ALG440 GE Fanuc Serie 90-30 Analog Inngangskort","description":"\u003ch2\u003eProduktoversikt\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc IC697ALG440\u003c\/strong\u003e er en høy-tetthets, 16-kanals analog inngangsekspansjonsmodul designet for å øke overvåkingskapasiteten til ditt GE Series 90 industrikontrollsystem. Med en vekt på bare 0,61 kilo (1,34 lbs) og et kompakt format på 4 cm x 21,8 cm x 29,2 cm, fungerer denne modulen som et ekspansjonsgrensesnitt som fanger opp store mengder feltdata. Ved å koble den sømløst med basiskonverteringsmoduler, gjør den det mulig for komplekse kontrollsystemer å overvåke omfattende arrays av 4-20 mA og spenningssendere samtidig.\u003c\/p\u003e\n\n\u003ch2\u003eKjernefordeler\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e16-kanals høy-tetthets ekspansjon:\u003c\/strong\u003e Maksimerer plass i rack ved å samle 16 separate strøminnganger på ett enkelt spor, noe som reduserer totale maskinvareinstallasjonskostnader.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDobbelt signal-kompatibilitet:\u003c\/strong\u003e Bygget for å behandle både standard 4 til 20 mA industrielle strømsløyfer og allsidige -10 til +10 VDC spenningsområder for bred prosess-telemetri.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFabrikkalibrert presisjon:\u003c\/strong\u003e Leveres med en svært stabil fabrikkalibrering satt til 10 Volt ±2 mV, som gir eksepsjonell plug-and-play målenøyaktighet rett ut av esken.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske spesifikasjoner\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpesifikasjonsdetaljer\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMerke \/ Modellnummer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc \/ IC697ALG440\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBruttovekt\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0,61 kilo (1,34 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eModulklassifisering\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAnalog inngangsekspansjonsmodul (Series 90-plattform)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eTotalt antall signalinnganger\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e16 strøm-\/spenningsinngangskanaler\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eStrømsignalområde\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4 til 20 mA sløyfestrømområde\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eSpenningssignalområde\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-10 VDC til +10 VDC område\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eKalibreringsreferansegrense\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFabrikkinnstilt til 10 Volt ±2 mV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eInternt strømforbruk\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e+5 VDC backplane logikk strømforsyningskrav\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eFysiske mål\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4,0 cm (B) x 21,8 cm (D) x 29,2 cm (H)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallasjons- og ingeniørveiledning\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaskinvareparingsoppsett:\u003c\/strong\u003e Skyv det lette 0,61 kg ekspansjonskortet inn i det tildelte sporet rett ved siden av basismodulen for analog konvertering. Sørg for at backplane-kontaktene kobles riktig for å opprettholde pålitelig bussutvidelse.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSkjerming av feltinstrumenter:\u003c\/strong\u003e Koble dine 4-20 mA eller ±10 V instrumenter direkte til modulens terminalblokker. Før all signalkabling gjennom separate jordede industrielle kanaler for å skjerme den høy-tette analoge matrisen mot høystrøms elektromagnetiske forstyrrelser.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTermisk styring:\u003c\/strong\u003e Oppretthold tilstrekkelige luftspalter rundt det 4 cm brede kabinettet. Dens energieffektive design krever lavt strømforbruk, men god konveksjonsluftstrøm inne i kapslingen hjelper til med å forhindre varmeopphopning fra omkringliggende utstyr.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Fungerer IC697ALG440 som en frittstående analog behandlingsmodul?\u003c\/strong\u003e\u003cbr\u003e\nA1: Nei. Denne maskinvaren er klassifisert som en ekspansjonsmodul; den må kobles sammen med en primær basismodul for analog konvertering for å sende digitaliserte instrumenteringssløyfesignaler til prosessoren.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Hvilken fordel gir fabrikkalibreringen på 10V ±2mV under installasjon?\u003c\/strong\u003e\u003cbr\u003e\nA2: Den garanterer svært stabile driftsbaser uten behov for feltkalibrering under oppstart, noe som sparer betydelige ingeniørtimer ved igangkjøring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Kan denne kompakte modulen monteres trygt i trange kapslinger?\u003c\/strong\u003e\u003cbr\u003e\nA3: Ja. Med fysiske mål på 4 cm x 21,8 cm x 29,2 cm passer den kompakte fotavtrykket godt inn i standard dybde industrielle skap samtidig som den gir robust 16-kanals overvåking.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050794582148,"sku":"IC697ALG440","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697ALG440-GE.jpg?v=1781620047"},{"product_id":"ic200pwr001-versamax-power-supply-ge-fanuc-5v-3-3v-output","title":"IC200PWR001 Versamax Power Supply | GE Fanuc 5V\/3.3V Output","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200PWR001 Versamax DC Power Supply Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc \u003cstrong\u003eIC200PWR001\u003c\/strong\u003e is a 24V DC power supply module for the Versamax series. It provides backplane power to CPUs, NIUs, and I\/O modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e GE Fanuc \u003cstrong style=\"color: #d35400;\"\u003eIC200PWR001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax DC Power Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltages:\u003c\/strong\u003e 5 Volts DC \u0026amp; 3.3 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Output Current:\u003c\/strong\u003e 1.5 Amps maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.3V Output:\u003c\/strong\u003e 0.25 Amps maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V Output:\u003c\/strong\u003e 1.5A minus used 3.3V current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e 11 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoldup Time:\u003c\/strong\u003e 10 Milliseconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection \u0026amp; Electrical Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Features:\u003c\/strong\u003e Short circuit, overload, and reverse polarity protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 20A at 24V DC; 25A at 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirement:\u003c\/strong\u003e DC power source must be grounded to earth\/frame ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Options:\u003c\/strong\u003e No extended or isolated power options available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Details \u0026amp; Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (Module Only):\u003c\/strong\u003e 133.4 mm W x 39 mm H (5.25 x 1.54 in) - excludes carrier \u0026amp; DIN rail height\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Use:\u003c\/strong\u003e Main power supply when mounted on NIU or CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary Use:\u003c\/strong\u003e Booster power supply for larger I\/O configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e Available via FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the \u003cstrong\u003eIC200PWR001\u003c\/strong\u003e module used for?\u003c\/strong\u003e\u003cbr\u003eA: It converts 24V DC input to 5V\/3.3V DC to power Versamax system components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What protections does it include?\u003c\/strong\u003e\u003cbr\u003eA: It has built-in protection against short circuits, overloads, and reverse polarity connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can it be used as a booster?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it can serve as either the main supply or a secondary booster supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor pricing and technical support for the \u003cstrong\u003eIC200PWR001\u003c\/strong\u003e, contact us at \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050794942596,"sku":"IC200PWR001","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200_0022_IC200PWR001_1.jpg?v=1768020530"},{"product_id":"ic694mdl734-6-channel-10-8-150vdc-output-ge-fanuc","title":"IC694MDL734 6-Channel 10.8-150VDC Output GE Fanuc","description":"\u003ch2\u003eGE Fanuc IC694MDL734 Positive \u0026amp; Negative-Logic Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL734\u003c\/strong\u003e delivers six versatile outputs (10.8–150 V DC) with hot‑swap capability, robust isolation and diagnostic LEDs for rapid status checks.\u003c\/p\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 6 isolated channels sourcing from positive or sinking to negative bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e10.8–150 V DC\u003c\/span\u003e (125 V DC rated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e1 A per point\u003c\/span\u003e, 3 A total common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 7 A per 100 ms at 2% duty cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 5–7 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC continuous, 1500 VAC for 1 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Draw:\u003c\/strong\u003e 90 mA from 5 V bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 5%–95% non‑condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude Rating:\u003c\/strong\u003e –500 to 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 12.7 × 101.6 × 115 mm (W × H × D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 150 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050794975364,"sku":"IC694MDL734","price":208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL734.jpg?v=1774337281"},{"product_id":"ic694mdl758-ge-fanuc-rx3i-output-module-32-channel-0-5a","title":"IC694MDL758 GE Fanuc RX3i Output Module 32 Channel 0.5A","description":"\u003ch2 style=\"color: #004080; font-weight: bold;\"\u003eGE Fanuc IC694MDL758 RX3i Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eGE Fanuc \u003cstrong\u003eIC694MDL758\u003c\/strong\u003e RX3i PACSystems discrete output module. 32 positive logic outputs in two isolated groups of 16. 12-24 VDC range, 0.5A per point, 8A per group. \u003c\/p\u003e\n\u003ch3 style=\"color: #004080;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL758\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e RX3i PACSystem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Discrete output module, positive logic (sourcing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 32 (two isolated groups of 16)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 12-24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 10.2-28.8 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 0.5A per point, 8.0A per group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Rating:\u003c\/strong\u003e 5.4 A for 10 ms (no ESCP trip)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 0.5 ms maximum (on and off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Draw:\u003c\/strong\u003e 250 mA maximum at 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5 kg (1.1 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #004080;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Output configuration?\u003c\/strong\u003e\u003cbr\u003eA: 32 positive logic outputs in 2 isolated groups of 16, 12-24 VDC, 0.5A per point, 8A per group.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Protection features?\u003c\/strong\u003e\u003cbr\u003eA: Integrated short-circuit protection (ESCP) per group with fault reporting to CPU. Field power loss detection also reported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Power and weight?\u003c\/strong\u003e\u003cbr\u003eA: 250mA backplane draw at 5V DC. Weight 0.5kg. Requires external user-supplied power. Compatible with IC694TBB032\/TBS032 terminal blocks.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eContact: \u003ca style=\"color: #004080; font-weight: bold;\" href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050795008132,"sku":"IC694MDL758","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC694MDL758.jpg?v=1774070998"},{"product_id":"ic693mdl732-ge-fanuc-discrete-12-24v-dc-0-5a-output-module","title":"IC693MDL732 GE Fanuc diskret 12\/24V DC 0,5A utgangsmodul","description":"\u003ch2\u003eProduktoversikt\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL732\u003c\/strong\u003e er en 8-punkts diskret sourcing utgangsmodul utviklet for det klassiske Series 90-30 programmerbare logikkontroller (PLC) økosystemet, opprinnelig utviklet av GE Fanuc (nå støttet av Emerson Automation Solutions). Modulen er konstruert for å kontrollere lavstrøms DC-feltlaster og opererer ved nominell driftsspenning på 12\/24V DC innenfor et aktivt driftsspenn. Med en ren sourcing (positiv logikk) utgangsprofil, bytter dette \u003cstrong style=\"color: #0056b3;\"\u003e0,18 kg (0,40 lbs)\u003c\/strong\u003e maskinvarekortet strøm direkte fra den positive forsyningsskinnen til felt-sidelaster, og gir en pålitelig grensesnitt for moderne industrielle utstyrskontrollsløyfer.\u003c\/p\u003e\n\n\u003ch2\u003eKjerne tekniske fordeler\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePositiv logikk sourcing-oppsett:\u003c\/strong\u003e Designet med standard sourcing-egenskaper der last-enheten kobles direkte mellom den negative DC-strømbussen og modulens utgangsterminal, noe som forhindrer utilsiktet lastaktivering ved tilfeldige jordfeil.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStabil strømfordelingsnode:\u003c\/strong\u003e Gir åtte uavhengige utgangspunkter med maksimal kontinuerlig strøm på 0,5 ampere per kanal, støttet av en intern bussstruktur som håndterer opptil 2,0 ampere toppstrøm per felles kretsring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHøy innrusningskapasitetsmatrise:\u003c\/strong\u003e Konstruert med robuste transistorbrytere i fast tilstand som kan absorbere plutselige transiente innrusningsstrømmer opptil 4,78 ampere i 10 millisekunder, og forhindrer feilutløsning ved tenning av induktive laster.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRaske kontrollresponssykluser:\u003c\/strong\u003e Leverer en svært responsiv utførelsesprofil med maksimal påslåingstid på 2,0 millisekunder og avslagstid på 2,0 millisekunder, som sikrer stramme og forutsigbare maskinsekvenssløyfer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske spesifikasjoner\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpesifikasjonsdetaljer\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModellkatalognummer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIC693MDL732\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduktserier\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc \/ Emerson Series 90-30 PLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eUtgangssignalkonfigurasjon\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDiskret sourcing transistorutgang (positiv logikk)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eTotalt aktive utgangspunkter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8 punkter arrangert i en enkelt isolert gruppe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eNominell driftsspenning\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e12 til 24V DC nominell belastningsforsyningslinje\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMaksimal utgangsstrøm (per punkt)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMaksimal kontinuerlig belastningsterskel på 0,5 ampere\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMaksimal utgangsstrøm (per felles)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMaksimal belastning på 2,0 ampere over delt returpunkt\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModulens strømbehov fra bakplanet\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMaksimalt 50 milliampere fra den interne 5V DC chassis-skinnen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMaksimal transient innstrømsbelastning\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4,78 ampere overspenningsgrense opprettholdt i opptil 10 millisekunder\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMekanisk netto masse\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0,18 kg (ca. 0,40 lbs) slank profilkort\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduktets livssyklusbetegnelse\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eStøttenode for utgått\/utdatert eldre maskinvare\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrielle løsninger\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePneumatisk magnetventilstyring:\u003c\/strong\u003e Aktiverer lavwattmanifoldmagnetventiler og retningskontrollventiler på automatiserte monteringslinjer med submillisekund presisjon.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLokale statusindikatorer:\u003c\/strong\u003e Driver kontrollpanelpilotlys, etterligningspaneler og hørbare feilsignaler i distribuert prosesseringsinfrastruktur.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotorstartergrensesnitt:\u003c\/strong\u003e Fungerer som et mellomliggende signalpunkt for å aktivere lavspenningsspoler på mekaniske motorkontaktorer eller hjelpereléer for maskiner.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOppgradering av eldre systemer:\u003c\/strong\u003e Fungerer som en nøyaktig erstatningsdel for å holde eldre Series 90-30 produksjonsceller i drift uten problemer, og unngår kostbare komplette systemoppgraderinger.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKabling og installasjon\u003c\/h2\u003e\n\u003ch3\u003eProtokoll for isolering av chassis\u003c\/h3\u003e\n\u003cp\u003eIsoler alle primære innkommende anleggslinjekilder og sekundære hjelpesløyfer for 12\/24V DC feltforsyning før du setter inn eller fjerner modulen. Håndtering av levende komponenter kan føre til kontaktbroer, utløse utilsiktede utgangssignaler i aktive logikksekvenser eller forårsake elektrisk skade på bakplanet.\u003c\/p\u003e\n\n\u003ch3\u003eInnsetting i chassis-sokkel\u003c\/h3\u003e\n\u003cp\u003eIC693MDL732-modulen er fullt kompatibel med enhver standard I\/O-sokkel på en GE Fanuc Series 90-30 5-sokkel eller 10-sokkel baseplate. Skyv kortkanten rett inn i plastkanalguidene, trykk fast til bakre kontakt sitter i bakplanet, og sjekk at de øvre og nedre mekaniske låsene klikker helt på plass.\u003c\/p\u003e\n\n\u003ch3\u003eParametere for feltkabling og sammenkobling\u003c\/h3\u003e\n\u003cp\u003eÅpne terminaldøren med fronthengsel og koble din eksterne 12\/24V DC strømkilde tilbake til modulens dedikerte felles inngangspunkt. Led de individuelle signallinjene ut fra de åtte terminalpinnene direkte til den positive siden av dine belastningsenheter, og sørg for at den negative returledningen fra hver belastning kobles tilbake til din hoved DC negative jordingslist.\u003c\/p\u003e\n\n\u003ch3\u003eOverspenningsbeskyttelse og sikringskompatibilitet\u003c\/h3\u003e\n\u003cp\u003eSiden IC693MDL732-modulen ikke inkluderer interne sikkerhetssikringer, anbefales det sterkt å installere et eksternt sikringsnettverk (vanligvis vurdert til 2,0 til 2,5 ampere tregt) på den primære 24V DC strømtilførselen. Når du bryter induktive laster som solenoider eller spoler, koble en ekstern dempingsdiode over lastterminalene for å forhindre at bak-EMF spenningspiker skader utgangstransistorene.\u003c\/p\u003e\n\n\u003ch2\u003eIngeniørmessige fordeler\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLavt strømforbruk fra bakplan:\u003c\/strong\u003e Trekker kun 50 milliampere fra 5V DC bakplansskinnen når alle punkter er fullt aktive, noe som frigjør mer strøm til komplekse CPU-moduler eller nettverkskort med høyt forbruk i samme rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHøyt synlige status-LED-er:\u003c\/strong\u003e Har en dedikert rekke med lyse grønne LED-indikatorer øverst på frontplaten, som gir sanntids visuell bekreftelse av hver utgangskanals PÅ\/AV-status for rask feilsøking i felt uten laptop.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKompakt vekt på 0,18 kg:\u003c\/strong\u003e Den lette fysiske vekten på 0,18 kg reduserer belastningen på chassis-skinner, noe som gjør det mulig å pakke flere moduler tett sammen i kompakte eller utsvingbare kapslingspaneler.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eForutsigbar isolasjon i av-stilling:\u003c\/strong\u003e Begrenser lekkasjestrøm i av-stilling til maksimalt 1 milliampere, noe som sikrer at feltreléer med høy impedans eller sensitive elektroniske innganger kobler ut pålitelig uten å sitte fast i PÅ-stilling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTekniske FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Hva skjer hvis en utgangslinje opplever en kortslutning til jord?\u003c\/strong\u003e\u003cbr\u003e\nA1: Fordi IC693MDL732 ikke har interne sikringer, vil en ubeskyttet kortslutning til jord overstige transistorens grense på 0,5A og raskt brenne ut kanalen. For å beskytte modulen må du installere en ekstern sikring eller en strømlimiterende enhet på strømledningen som forsyner utgangsfelles.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Kan jeg trygt styre et AC-drevet indikatorlys med denne modulen?\u003c\/strong\u003e\u003cbr\u003e\nA2: Nei. IC693MDL732 bruker interne halvleder DC-transistorer som fungerer strengt innenfor et spenningsområde på 12 til 24V DC. Forsøk på å føre vekselstrøm (AC) gjennom disse terminalene vil hindre modulen i å slå seg av og forårsake umiddelbar, permanent skade på kretskortet.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Hvorfor er det maksimale spenningsfallet på 1 Volt i på-tilstand viktig for systemingeniørarbeid?\u003c\/strong\u003e\u003cbr\u003e\nA3: Når en utgangskanal er fullt aktiv, forårsaker intern halvledermotstand et lite spenningsfall på opptil 1V DC over transistoren. Dette betyr at hvis feltforsyningen din leverer 12,0V DC ved felles terminal, vil spenningen ved utgangspinnen være omtrent 11,0V DC; kontroller at dine feltaktuatorer kan fungere pålitelig ved denne litt lavere spenningen.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050795827332,"sku":"IC693MDL732","price":137.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693MDL732.jpg?v=1782140055"},{"product_id":"ge-fanuc-ic200chs102-versamax-expansion-base","title":"GE Fanuc IC200CHS102 VersaMax Expansion Base","description":"\u003ch2\u003eGE Fanuc Versamax \u003cstrong\u003eIC200CHS102\u003c\/strong\u003e Disconnect-Style Interposing I\/O Terminal Expansion Base\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200CHS102\u003c\/strong\u003e is a disconnect-style interposing I\/O terminal expansion base from the GE Fanuc Versamax product line. This expansion base works with the \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eIC200CHS101 main base\u003c\/span\u003e to provide disconnect options for field devices connected to I\/O modules with \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eB-type terminals\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eExpansion base\u003c\/span\u003e for disconnect-style interposing I\/O terminals\u003c\/li\u003e\n\u003cli\u003eRequired for I\/O modules with \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eB-type terminals\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e36 box-style terminals\u003c\/span\u003e for power inputs and field I\/O wiring\u003c\/li\u003e\n\u003cli\u003eTwo groups of terminals: \u003cspan style=\"color: #c41e3a;\"\u003eY1 to Y8\u003c\/span\u003e and \u003cspan style=\"color: #2e8b57;\"\u003eZ1 to Z8\u003c\/span\u003e for 2-wire devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3498db; font-weight: bold;\"\u003eJ2 connector\u003c\/span\u003e for ribbon cable attachment to IC200CHS101 base\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cspan style=\"color: #c41e3a;\"\u003eribbon cable\u003c\/span\u003e for connecting to IC200CHS101\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eIP54 enclosure rating\u003c\/span\u003e recommended for protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC200CHS102\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Disconnect-style interposing I\/O terminals, expansion base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e36 box-style terminals\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Groups:\u003c\/strong\u003e Y1-Y8 and Z1-Z8 for 2-wire devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e-40 to 60°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e-40 to 85°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e5 to 95%\u003c\/span\u003e non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eIP54\u003c\/span\u003e (recommended steel enclosure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Rating:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e1G at 57 Hz to 150 Hz\u003c\/span\u003e, 0.012 inches peak-to-peak at 10-57 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e J2 for ribbon cable to IC200CHS101\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x GE Fanuc \u003cstrong\u003eIC200CHS102\u003c\/strong\u003e expansion base\u003c\/li\u003e\n\u003cli\u003e1x ribbon cable for connecting to IC200CHS101\u003c\/li\u003e\n\u003cli\u003e1x installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eFedEx, UPS, DHL\u003c\/span\u003e express worldwide\u003c\/li\u003e\n\u003cli\u003eShips within \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e24 hours\u003c\/span\u003e from stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the part number for this expansion base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number is \u003cstrong style=\"color: #c41e3a;\"\u003eIC200CHS102\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. When is the IC200CHS102 required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is required for I\/O modules with \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eB-type terminals\u003c\/span\u003e. For A-type terminals, use the IC200CHS101 main base.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. How many terminals does it have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt has \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e36 box-style terminals\u003c\/span\u003e including Y1-Y8 and Z1-Z8 groups for 2-wire devices.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050796187780,"sku":"IC200CHS102","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200CHS102.jpg?v=1771336557"},{"product_id":"ge-ic200chs101-interposing-terminal-base","title":"GE IC200CHS101 Interposing Terminal Base","description":"\u003ch2\u003eGE Fanuc Versamax \u003cstrong\u003eIC200CHS101\u003c\/strong\u003e Disconnect-Style Interposing I\/O Terminals\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200CHS101\u003c\/strong\u003e is a disconnect-style interposing I\/O terminal module from the GE Fanuc Versamax product line. This module provides an \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003einterface between field wiring\u003c\/span\u003e and a connector-style I\/O carrier. \u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eIndividual knife-switch disconnects\u003c\/span\u003e for each signal and return terminal\u003c\/li\u003e\n\u003cli\u003eAllows \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eindividual I\/O points\u003c\/span\u003e to be taken offline without changing system wiring\u003c\/li\u003e\n\u003cli\u003eProvides connections for \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003eA1 to A18 terminals\u003c\/span\u003e (A side of Versamax connector)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003eJ1 connector\u003c\/span\u003e for interfacing with connector-style I\/O carriers via cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eJ2 connector\u003c\/span\u003e for connecting to IC200CHS102 disconnect base\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cspan style=\"color: #3498db;\"\u003eIC200CBL105, IC200CBL110, and IC200CBL120\u003c\/span\u003e cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC200CHS101\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Disconnect-style interposing I\/O terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid Copper Wire Size:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e0.2 to 4.0 mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStranded Copper Wire Size:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0.2 to 2.5 mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Wire (rigid\/flexible):\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e0.2 to 1.5 mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStranded with ferrules (no plastic sleeve):\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e0.25 to 0.75 mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0.5 to 0.6 Nm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Cables:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003eIC200CBL105, IC200CBL110, IC200CBL120\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Clearance - Horizontal:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e1 inch\u003c\/span\u003e minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Clearance - Vertical:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e2 inches\u003c\/span\u003e minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e115 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e65 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e126 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Dimensions:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e115 x 65 x 126 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x GE Fanuc \u003cstrong\u003eIC200CHS101\u003c\/strong\u003e disconnect-style interposing I\/O terminal module\u003c\/li\u003e\n\u003cli\u003e1x installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eFedEx, UPS, DHL\u003c\/span\u003e express worldwide\u003c\/li\u003e\n\u003cli\u003eShips within \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e24 hours\u003c\/span\u003e from stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the part number for this disconnect module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number is \u003cstrong style=\"color: #c41e3a;\"\u003eIC200CHS101\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What is the function of the IC200CHS101?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eindividual knife-switch disconnects\u003c\/span\u003e for each signal and return terminal, allowing individual I\/O points to be taken offline without rewiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What cables are compatible with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompatible cables include \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003eIC200CBL105, IC200CBL110, and IC200CBL120\u003c\/span\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050796220548,"sku":"IC200CHS101","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200CHS101-3.jpg?v=1771335982"},{"product_id":"ic200mdl140-versamax-120v-module-ge-fanuc","title":"IC200MDL140 VersaMax 120V Module GE Fanuc","description":"\u003ch2\u003eGE Fanuc VersaMax \u003cstrong\u003eIC200MDL140\u003c\/strong\u003e Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200MDL140\u003c\/strong\u003e is an 8-point discrete input module from the GE Fanuc VersaMax Modular I\/O and Control System. This module features \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e8 individually-isolated inputs\u003c\/span\u003e operating at \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e120 Volts AC\u003c\/span\u003e with a range of 0-132V AC. \u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e8 individually-isolated discrete inputs\u003c\/span\u003e in one group\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e120V AC nominal voltage\u003c\/span\u003e (0-132V AC operating range)\u003c\/li\u003e\n\u003cli\u003eOn-state range: \u003cspan style=\"color: #3498db;\"\u003e70-132V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOff-state range: \u003cspan style=\"color: #c41e3a;\"\u003e0-20V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57;\"\u003ePositive logic \/ sourcing inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eMaximum backplane current: \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e55 mA @5V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInput impedance: \u003cspan style=\"color: #c41e3a;\"\u003e8.6 kΩ @60Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum response time (on): \u003cspan style=\"color: #2e8b57;\"\u003e1 cycle\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3498db;\"\u003e16 individually numbered LEDs\u003c\/span\u003e for input status + 1 power LED\u003c\/li\u003e\n\u003cli\u003eDimensions: \u003cspan style=\"color: #c41e3a;\"\u003e110 x 66.8 x 50.0 mm\u003c\/span\u003e (4.3 x 2.63 x 1.956 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eIC200MDL140\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription:\u003c\/strong\u003e Discrete Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Versamax I\/O and Control System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e8 discrete inputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e120 Volts AC nominal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e0-132V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e70-132V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e0-20V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Rating:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e55 mA @5V max\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e8.6 kΩ @60Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Response Time (On):\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e1 cycle\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003eNone (single group of 8)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Power:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eYes - from backplane\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation:\u003c\/strong\u003e Versamax I\/O Carriers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x GE Fanuc \u003cstrong\u003eIC200MDL140\u003c\/strong\u003e discrete input module\u003c\/li\u003e\n\u003cli\u003e1x installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eFedEx Priority Overnight\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eUPS 2-Day Air\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #3498db; font-weight: bold;\"\u003eDHL Express Worldwide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eGround shipping available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many inputs does the \u003cstrong\u003eIC200MDL140\u003c\/strong\u003e have and what is their configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt has \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e8 individually-isolated discrete inputs\u003c\/span\u003e arranged in a single group, operating as positive logic\/sourcing inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the voltage range and power requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt operates at \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e120V AC nominal\u003c\/span\u003e (0-132V AC range) with on-state 70-132V AC. Power is drawn from the backplane at \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e55 mA @5V max\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module support hot swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, when installed on a Versamax I\/O carrier with snap-in design, it supports \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003ehot module insertion and removal\u003c\/span\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050796318852,"sku":"IC200MDL140","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200MDL140.jpg?v=1771642732"},{"product_id":"input-module-ge-ic200mdl644-32-point-ttl-compatible","title":"Input Module GE IC200MDL644 32-Point TTL Compatible","description":"\u003ch2\u003eGE Fanuc VersaMax \u003cstrong\u003eIC200MDL644\u003c\/strong\u003e 32-Point Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200MDL644\u003c\/strong\u003e is a high-density 32-point discrete input module from the GE Fanuc VersaMax series featuring \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e32 input points\u003c\/span\u003e arranged in \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e4 groups of 8\u003c\/span\u003e. \u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eGE Fanuc\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eSeries:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003eVersaMax\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eIC200MDL644\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eModule ID:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e80088008\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eProduct Type:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003eDiscrete Input Module\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eNumber of Inputs:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e32 points\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eInput Groups:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e4 groups of 8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eSupported Logic:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003ePositive and Negative\u003c\/span\u003e (negative logic TTL compatible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eInput Voltage Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0-15 Volts DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eNominal Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e5\/12 Volts DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eInput Impedance:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e2.4K Ohms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eUser Input Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e1.8 mA @5VDC, 4.9 mA @12VDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eOn-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e4.2 to 15 Volts DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eOff-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e0 to 2.6 Volts DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eConfigurable Filter Times:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0 ms, 1.0 ms, 7.0 ms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eBackplane Current:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e5 Volts @ 140 mA max\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eExternal Power Supply:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003eNone required\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIsolation Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eGroup-to-Group Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e250 VAC continuous\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eGroup-to-Group (1 min):\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e1500 VAC for 1 minute\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003ePoint-to-Point Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003eNone\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x GE Fanuc \u003cstrong\u003eIC200MDL644\u003c\/strong\u003e discrete input module\u003c\/li\u003e\n\u003cli\u003e1x installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the part number for this VersaMax high-density input module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number is \u003cstrong style=\"color: #c41e3a;\"\u003eIC200MDL644\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What are the key specifications of the \u003cstrong\u003eIC200MDL644\u003c\/strong\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt features \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e32 inputs in 4 groups of 8, 5\/12VDC nominal (0-15VDC range), 2.4KΩ impedance, configurable filters (0\/1\/7ms), and 140mA backplane current\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is this module TTL compatible?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, when configured for \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003enegative logic operation, the IC200MDL644 is compatible with TTL devices\u003c\/span\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050796351620,"sku":"IC200MDL644","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200MDL644.jpg?v=1771838516"},{"product_id":"ge-fanuc-ic693mdl646-series-90-30-16-pt-discrete-input","title":"GE Fanuc IC693MDL646 Series 90-30 16-punkts diskret inngang","description":"\u003ch2\u003eProduktoversikt\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #2c3e50;\"\u003eGE Fanuc IC693MDL646\u003c\/strong\u003e (nå støttet under Emerson Automation) er en premium, høy-tetthet \u003cstrong style=\"color: #2c3e50;\"\u003e16-kanals 24VDC hurtigresponssignal diskret inngangsmodul\u003c\/strong\u003e utviklet for Series 90-30 PLC maskinvareplattform. I motsetning til standard DC-inngangskort som har tregere linjefiltreringssykluser, er IC693MDL646 spesielt bygget for høyhastighets automatiserte prosesser som krever lav latens tilstandssporing og mikrosekund signal-synkronisering. Med en fleksibel \u003cstrong style=\"color: #2c3e50;\"\u003e0 til +30V DC inngangsområde\u003c\/strong\u003e tilbyr modulen en svært allsidig intern konfigurasjon som støtter både \u003cstrong style=\"color: #2c3e50;\"\u003epositiv og negativ logikk (Sink eller Source ledningsføring)\u003c\/strong\u003e oppsett. Innkapslet i en standard 90-30 slot formfaktor som veier \u003cstrong style=\"color: #2c3e50;\"\u003e0,55 kg (1,21 lbs)\u003c\/strong\u003e, kobler den raskt skiftende felttelemetri med PLC-behandlingskjerner.\u003c\/p\u003e\n\n\u003ch2\u003eKjerne tekniske fordeler\u003c\/h2\u003e\n\u003ch3\u003eUltralav 1 ms maskinvarefiltreringsforsinkelse\u003c\/h3\u003e\n\u003cp\u003eDet karakteristiske arkitekturforbedringen til IC693MDL646 er dens ultrarask maskinvare signalfiltreringskrets. Den har en overgangsresponstid som er betydelig raskere enn generelle innganger, og minimerer inngangspropageringsforsinkelse ned til omtrent 1 millisekund. Dette muliggjør umiddelbar fangst av transientpulser, hurtigbevegelige delindikatorer og kantdeteksjonsendringer som typiske inngangskort overser.\u003c\/p\u003e\n\n\u003ch3\u003eTo-veis Sink\/Source isolasjon\u003c\/h3\u003e\n\u003cp\u003eDe 16 inngangskanalene er strukturert for å gi feltteknikere absolutt ledningsfleksibilitet. Ved å dele terminalkonfigurasjonene på isolerte felles referansepunkter, kan modulen enkelt blandes med NPN (Sink) eller PNP (Source) industrielle feltsensorer, proxybrytere og elektroniske kontrollreléer uten å legge til eksterne signalbehandlingsblokker.\u003c\/p\u003e\n\n\u003ch3\u003eRigid industriell bakplaneintegrasjon\u003c\/h3\u003e\n\u003cp\u003eOptimalisert for tett støyimmunitet innen overfylte motorstyringssentre, grensesnittet modulen rent gjennom den standard Series 90-30 parallelle bakplanet. Den trekker nominell strøm direkte fra systemets strømforsyningschassis, og opprettholder lavt strømforbruk samtidig som den opprettholder stabil høyhastighetsskanningsfrekvens under kontinuerlige belastningsendringer.\u003c\/p\u003e\n\n\u003ch2\u003eTekniske spesifikasjoner\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2; border-bottom: 2px solid #ddd;\"\u003e\n      \u003cth style=\"padding: 10px; text-align: left; border: 1px solid #ddd;\"\u003eParameterkode\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; text-align: left; border: 1px solid #ddd;\"\u003eSpesifikasjonsdetaljer\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eProdusent \/ merke\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eGE Fanuc \/ Emerson Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eKatalog maskinvare nummer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eIC693MDL646 (Series 90-30)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eModulfunksjon\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e16-punkts hurtig respons DC diskret inngang\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eVurdert driftsspenning\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e24 Volt DC nominell (maks inngangsområde: 30V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003ePå-tilstand spenningsvindu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e11,5 VDC til 30 VDC akseptabel spenningsgrense\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eAv-tilstand spenningsgrense\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e0 VDC til +5 VDC (Sikrer ren logikkutkobling)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMinimum på-tilstand strøm\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e3,2 mA minimum drivkrav per aktivt punkt\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eSignalovergangsforsinkelse\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e~1 ms maskinvarefiltervurdering for umiddelbar sporing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eFeltlednings-type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePositiv eller negativ logikk (sink\/source konfigurasjonsvalg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eNetto fraktvekt\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e0,55 kg (1,21 lbs) kompakt layoutdesign\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallasjon og vedlikehold\u003c\/h2\u003e\n\u003ch3\u003eChassis-monterings- og spakengasjement\u003c\/h3\u003e\n\u003cp\u003eFor å installere IC693MDL646, velg en ledig I\/O-plass på Series 90-30 baseplate-chassiset. Sett kroken på nederste bakre kant av modulen inn i den nederste sporjusteringskanalen på baseplaten. Drei modulen oppover mot bakplan-kontaktens styreskinner, og trykk fast på øvre kant til modulen klikker og låses sikkert i den øvre strukturelle festeklipsen.\u003c\/p\u003e\n\n\u003ch3\u003eTerminalblokk felttermineringsarkitektur\u003c\/h3\u003e\n\u003cp\u003eFelt-signaler termineres direkte på den standard avtakbare terminalblokken festet til fronten av inngangsmodulen. Bruk høykvalitets kobberledere som matcher de fysiske layoutparametrene, og før lavspente 24VDC sensorsignaler bort fra tunge trefase AC induktive kraftlinjer for å beskytte signalintegriteten og forhindre utilsiktede emf-krysspratfeil.\u003c\/p\u003e\n\n\u003ch3\u003eSink- og Source-felles tilkoblingsruting\u003c\/h3\u003e\n\u003cp\u003eVed implementering av positiv logikk (sink) konfigurasjoner, koble de felles terminalene på frontkabelkontakten til den negative skinnen på din eksterne 24VDC strømforsyning. Omvendt, hvis du bruker negativ logikk (source) ledningstopologier med NPN-sensorer, koble de tilsvarende interne modulfelles direkte til den positive spenningsskinnen på strømforsyningen.\u003c\/p\u003e\n\n\u003ch2\u003eIngeniørmessige fordeler\u003c\/h2\u003e\n\u003ch3\u003eOptimalisert for høyhastighets deteksjonsmatriser\u003c\/h3\u003e\n\u003cp\u003eDen 1 ms maskinvarefiltreringskapasiteten gjør IC693MDL646 til den ideelle løsningen for registreringsmerkessensorer, pakkeverifiseringsmatriser, deler sorteringssløyfer og synkroniseringskretser der typiske PLC-skanningsinngangspropagasjonstider ville skapt prosesssporingsavvik.\u003c\/p\u003e\n\n\u003ch3\u003eHøy kanaltetthet i strukturelt fotavtrykk\u003c\/h3\u003e\n\u003cp\u003eVed å plassere 16 distinkte høyhastighets inngangskanaler i en enkelt fysisk Series 90-30-kabinettbredde sparer systemingeniører verdifull plass på DIN-skinnerammen, noe som eliminerer behovet for å stable flere lavdensitetskort og reduserer skapets konstruksjonslayout.\u003c\/p\u003e\n\n\u003ch3\u003eLangsiktig bevaring av legacy livssyklus\u003c\/h3\u003e\n\u003cp\u003eVed å opprettholde full bakoverkompatibilitet på tvers av hele Series 90-30-økosystemet, fungerer dette originale maskinvarekortet som en sømløs, plug-and-play vedlikeholdsreserve for nedgraderte moduler, og eliminerer behovet for komplekse logikkendringer eller omprogrammering av logikksystemet.\u003c\/p\u003e\n\n\u003ch2\u003eTekniske FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Kan IC693MDL646 akseptere høyhastighets pulstog fra digitale roterende enkodere?\u003c\/strong\u003e\u003cbr\u003e\nA1: Selv om IC693MDL646 har et raskt 1 ms filterrespons som er ideelt for rask nærhetssvitsjing og diskret sporing, er det ikke en dedikert høyhastighets teller-modul. For ultrahøyfrekvente multi-kHz kvadratur-enkoder tilbakemeldingssløyfer bør en dedikert bevegelsesmodul (som IC693APU300) integreres.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Hva skjer hvis en inngangsspenning stiger til 32VDC over en lengre driftsperiode?\u003c\/strong\u003e\u003cbr\u003e\nA2: Modulen er presisjonskonstruert for en kontinuerlig maksimal driftsspenning på 30VDC. Langvarige spenningsnivåer som overskrider dette området vil generere overflødig lokal termisk belastning i de interne opto-isolator motstandsnettverkene, noe som potensielt kan redusere modulens levetid eller forårsake permanente kanalfail.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Krever denne modulen spesialtilpassede programvareregisterendringer for å aktivere hurtig responstilstand?\u003c\/strong\u003e\u003cbr\u003e\nA3: Nei. De raske responsegenskapene til IC693MDL646 er hardkodet i dens interne komponentarkitektur. Når den er konfigurert som en standard 16-punkts inngangsmodul i ditt maskinvarekonfigurasjonsverktøy (som Proficy Machine Edition), er den lavlatente maskinvarefiltreringen umiddelbart funksjonell.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050796417156,"sku":"IC693MDL646","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693MDL646-1.jpg?v=1782137614"},{"product_id":"module-ge-ic200mdl144-discrete-input-ac","title":"Module GE IC200MDL144 Discrete Input AC","description":"\u003ch2\u003eGE Fanuc VersaMax \u003cstrong\u003eIC200MDL144\u003c\/strong\u003e 4-Channel Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200MDL144\u003c\/strong\u003e is a 4-channel discrete input module from the GE Fanuc VersaMax I\/O and Control System featuring \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e4 individually-isolated inputs\u003c\/span\u003e with \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e240 Volts AC operating voltage\u003c\/span\u003e. This module provides \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e2000V AC point-to-point isolation\u003c\/span\u003e for 1 minute and draws \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e30 mA maximum backplane current\u003c\/span\u003e at 5V DC.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e4 individually-isolated discrete inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e240V AC nominal voltage\u003c\/span\u003e (0-264V AC operating range)\u003c\/li\u003e\n\u003cli\u003eFrequency: \u003cspan style=\"color: #3498db;\"\u003e47-63 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #c41e3a;\"\u003ePositive logic\/sourcing-type inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eMaximum backplane current: \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e30 mA @5V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum on-state current: \u003cspan style=\"color: #3498db;\"\u003e7.0 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn-state voltage: \u003cspan style=\"color: #c41e3a;\"\u003e155-264V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOff-state voltage: \u003cspan style=\"color: #2e8b57;\"\u003e0-40V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum response time (on): \u003cspan style=\"color: #3498db;\"\u003e1 cycle\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e2000V AC point-to-point isolation\u003c\/span\u003e (1 minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e500V AC continuous isolation\u003c\/span\u003e (inputs to ground)\u003c\/li\u003e\n\u003cli\u003eDimensions: \u003cspan style=\"color: #3498db;\"\u003e110 x 66.8 x 50.0 mm\u003c\/span\u003e (4.3 x 2.63 x 1.956 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eIC200MDL144\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription:\u003c\/strong\u003e Discrete Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Versamax I\/O and Control System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e4 discrete inputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003ePositive logic \/ sourcing-type\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e240 Volts AC nominal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0-264V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e47-63 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e155-264V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0-40V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum On-State Current:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e7.0 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Response Time (On):\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e1 cycle\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Rating:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e30 mA @5V max\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003eYes - individually isolated\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoint-to-Point Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e2000V AC for 1 minute\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e500V AC continuous\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Power:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003eYes - from backplane\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation:\u003c\/strong\u003e Versamax I\/O Carriers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many inputs does the \u003cstrong\u003eIC200MDL144\u003c\/strong\u003e have and what is their configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt has \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e4 individually-isolated discrete inputs\u003c\/span\u003e that are positive logic\/sourcing type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the voltage range and power requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt operates at \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e240V AC nominal\u003c\/span\u003e (0-264V AC, 47-63 Hz) and draws \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e30 mA @5V from backplane\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What isolation ratings does this module provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e2000V AC point-to-point isolation for 1 minute\u003c\/span\u003e and \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e500V AC continuous isolation between inputs and ground\u003c\/span\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050796449924,"sku":"IC200MDL144","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200MDL144.jpg?v=1771643606"}],"url":"https:\/\/www.etowonauto.com\/nb\/collections\/general-electric.oembed?page=57","provider":"Etowon Auto","version":"1.0","type":"link"}