{"product_id":"ge-is220ppdah1a-power-distribution-system-pack-mark-vie","title":"GE IS220PPDAH1A Power Distribution System Pack Mark VIe","description":"\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; width: 40%;\"\u003eManufacturer \/ Brand\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eGE (General Electric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eMark VIe Distributed Control System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e\u003cspan style=\"color: #0044cc; font-weight: bold;\"\u003eIS220PPDAH1A\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eFunctional Acronym\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003ePPDA (Power Distribution System Feedback Board)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003ePower Distribution System Feedback I\/O Pack\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eProcessor Board\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eInternal BPPB Processor Card\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eAnalog Inputs \u0026amp; Status LEDs\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e5 Analog Inputs | 8 Diagnostic LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eHost PDM Board Compatibility\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eJPDS, JPDM, JPDG, or JPDC 28V DC Distribution Boards\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eSupported Feedback Boards\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eJPDB, JPDE, JPDF, JPDG, JPDM, JPDS via 50-pin ribbon cables\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eCircuit Protection Coating\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eConformal Coated PCB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eApprox. 0.45 kg (0.99 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe GE \u003cspan style=\"color: #0044cc; font-weight: bold;\"\u003eIS220PPDAH1A\u003c\/span\u003e is a Power Distribution System Feedback (PPDA) I\/O Pack weighing approximately 0.45 kg (0.99 lbs), engineered for General Electric's Mark VIe turbine control and industrial automation systems. Equipped with an internal BPPB processor card and 5 analog inputs, this lightweight module receives feedback from up to six Power Distribution Modules (PDMs). Mounted on JPDS, JPDM, JPDG, or JPDC 28V DC control power distribution boards, it transmits diagnostic data—including ground fault detection, bus voltage levels, and branch circuit fuse conditions—over dual redundant IONet Ethernet interfaces.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive PDM System Monitoring:\u003c\/strong\u003e Provides real-time feedback on ground fault detection, power bus health, branch circuit fuses, and voltage levels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Board Feedback Support:\u003c\/strong\u003e Interconnects with up to six PDM core boards (JPDB, JPDE, JPDF, JPDG, JPDM, JPDS) via 50-pin ribbon cable jumpers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug-and-Play Electronic ID:\u003c\/strong\u003e Utilizes electronic ID hardware verification to automatically identify attached distribution boards and populate IONet feedback data.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Ethernet Redundancy:\u003c\/strong\u003e Connects to dual IONet ports for continuous communication with Mark VIe controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Essentials\u003c\/h2\u003e\n\u003cp\u003eMount the IS220PPDAH1A I\/O pack directly onto the host terminal board (JPDS, JPDM, JPDG, or JPDC) via the DC-62 pin connector and mechanically secure it using the threaded bracket screws. Connect 50-pin ribbon cable jumpers pin-to-pin from connector P2 to additional daisy-chained core boards. Connect ENET1 and ENET2 to the IONet network. The integrated soft-start feature safe-guards internal circuitry from current inrush upon power-up. Configuration and system diagnosis are performed using ToolboxST software.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary function of the GE IS220PPDAH1A I\/O pack?\u003c\/strong\u003e\u003cbr\u003e\nA1: It monitors power distribution conditions (ground faults, bus voltages, fuse status) across up to 6 PDM boards and reports diagnostic data to Mark VIe controllers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Which host power distribution boards are compatible with the IS220PPDAH1A?\u003c\/strong\u003e\u003cbr\u003e\nA2: It mounts directly onto JPDS, JPDM, JPDG, or JPDC 28V DC power distribution boards.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What internal processor board is used in the IS220PPDAH1A?\u003c\/strong\u003e\u003cbr\u003e\nA3: The IS220PPDAH1A version contains an internal BPPB processor board.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52645913886852,"sku":"IS220PPDAH1A","price":162.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IS220PPDAH1A.jpg?v=1786787995","url":"https:\/\/www.etowonauto.com\/ms\/products\/ge-is220ppdah1a-power-distribution-system-pack-mark-vie","provider":"Etowon Auto","version":"1.0","type":"link"}