{"product_id":"abb-electro-pneumatic-positioner-tzidc-ip65-v18345-1010121001","title":"ABB Electro-Pneumatic Positioner TZIDC IP65 V18345-1010121001","description":"\u003ch2 style=\"color: #2c3e50; border-bottom: none; padding-bottom: 6px;\"\u003eABB \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003eV18345-1010121001\u003c\/span\u003e TZIDC Electro-Pneumatic Positioner\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eABB \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003eV18345-1010121001\u003c\/span\u003e is an intelligent, configurable electro-pneumatic positioner from the TZIDC series with indicator and operator panel. Features varnished aluminum case IP65 (NEMA 4X) for mounting to linear actuators per DIN\/IEC 534\/NAMUR or rotary actuators per VDI\/VDE 3845. Accepts 4-20mA two-wire input with LKS adapter connector plug. Single acting fail safe action. Includes plug-in analog position feedback module 4-20mA. Weight 1.7 kg.\u003c\/p\u003e\n\n\u003ch3\u003eModel Number Decoder\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePosition\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBase\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eV18345\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eTZIDC intelligent, configurable with indicator and operator panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCase\/Mounting\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eVarnished aluminum IP65, DIN\/IEC 534\/NAMUR or VDI\/VDE 3845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInput\/Communication\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e4-20mA two-wire with LKS adapter connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOutput\/Safe Position\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eSingle acting, fail safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eConnections\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCable 1\/2-14 NPT, Air 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOption Modules\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePlug-in analog position feedback 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMech Feedback\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDesign\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eV18345-1010121001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eTZIDC Electro-Pneumatic Positioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eAction\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eSingle Acting, Fail Safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e4 to 20 mA two-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDigital Input\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0 to 5V DC (logic 0), 11 to 30V DC (logic 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDigital Output\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e5 to 11V DC per DIN 19234\/NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eSupply Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1.4 to 6 bar (20 to 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eAir Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e\u0026lt; 0.03 kg\/h (0.015 scfm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eAluminum, epoxy resin varnish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eIP65, NEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e2 threads 1\/2-14 NPT or M20x1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePneumatic Connection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eG 1\/4 or 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMax 1.0 mm² (options), max 2.5 mm² (analog)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHumidity Operational\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e95% annual average, condensation permissible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHumidity Storage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e75% annual average, non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eMount on linear actuators per DIN\/IEC 534\/NAMUR or rotary actuators per VDI\/VDE 3845. Ready for integral mounting. Connect 4-20mA two-wire input with LKS adapter. Wire electrical connection at 1\/2-14 NPT or M20x1.5. Connect air supply at G 1\/4 or 1\/4-18 NPT with 1.4 to 6 bar pressure. Do not expose terminals to strain. Verify IP65 seal after installation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cp\u003eIntelligent configurable positioner with indicator and operator panel. Single acting fail safe action for power failure safety. 4-20mA two-wire input with LKS adapter connector. Plug-in analog position feedback module 4-20mA. Air consumption less than 0.03 kg\/h independent of supply pressure. Aluminum case with epoxy resin varnish. IP65 NEMA 4X protection. Operating temperature 40°C to +85°C. Humidity tolerance 95% with condensation permissible.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the action type and fail position?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Single acting with fail safe action. In case of electrical power failure, the valve moves to its safe position. 4-20mA two-wire input with LKS adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What are the pneumatic and electrical connection sizes?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Electrical 1\/2-14 NPT or M20x1.5. Pneumatic G 1\/4 or 1\/4-18 NPT. Supply pressure 1.4 to 6 bar (20 to 90 psi).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the air consumption and operating temperature?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Air consumption less than 0.03 kg\/h independent of supply pressure. Operating temperature 40°C to +85°C. IP65 NEMA 4X protection.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68128030359684,"sku":"V18345-1010121001","price":146.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18345-1010121001.jpg?v=1795093748","url":"https:\/\/www.etowonauto.com\/ms\/products\/abb-electro-pneumatic-positioner-tzidc-ip65-v18345-1010121001","provider":"Etowon Auto","version":"1.0","type":"link"}