{"product_id":"schneider-140hli34000-latch-interrupt-module","title":"Schneider 140HLI34000 Latch Interrupt Module","description":"\u003ch2\u003eSchneider Electric Modicon Quantum \u003cstrong\u003e140HLI34000\u003c\/strong\u003e Latch\/Interrupt Module – 16 Fast Isolated Inputs\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e140HLI34000\u003c\/strong\u003e is a latch\/interrupt module from the Schneider Electric Modicon Quantum automation platform. This module features \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e16 fast isolated discrete inputs\u003c\/span\u003e with exceptional response times of \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e130 µs (Off-On) and 30 µs (On-Off)\u003c\/span\u003e. It provides \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e500V isolation between channels\u003c\/span\u003e for reliable operation in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e16 fast isolated discrete inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eResponse time: \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e130 µs Off-On\u003c\/span\u003e, \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e30 µs On-Off\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003e500V AC isolation\u003c\/span\u003e between channels (60s)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e1780V AC isolation\u003c\/span\u003e between channels and bus (60s)\u003c\/li\u003e\n\u003cli\u003eVoltage state 1 guaranteed: \u003cspan style=\"color: #3498db;\"\u003e15-30V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eVoltage state 0 guaranteed: \u003cspan style=\"color: #c41e3a;\"\u003e-3 to 5V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eInternal reverse polarity protection\u003c\/span\u003e at 30V\u003c\/li\u003e\n\u003cli\u003eCertified for \u003cspan style=\"color: #3498db;\"\u003eCSA Class 1 Division 2\u003c\/span\u003e and \u003cspan style=\"color: #c41e3a;\"\u003eFM Class 1 Division 2\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eDNV, GOST, C-tick\u003c\/span\u003e certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon Quantum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003e140HLI34000\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Latch\/Interrupt Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e16\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Input Type:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003eFast isolated\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Input:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e30 V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage State 1 Guaranteed:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e15-30 V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage State 0 Guaranteed:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e-3 to 5 V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent State 1 Guaranteed:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e2-8 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent State 0 Guaranteed:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e≤0.5 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Off-On:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e130 µs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time On-Off:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e30 µs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eInternal at 30V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Between Channels:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e500V AC for 60s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Channels to Bus:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e1780V AC for 60s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Current Requirement:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e400 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e2.0W + (0.3 x number of points on)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Support:\u003c\/strong\u003e Backplane for local architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Format:\u003c\/strong\u003e Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e0 to 60°C\u003c\/span\u003e (32 to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e-40 to 85°C\u003c\/span\u003e (-40 to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e95%\u003c\/span\u003e without condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003eup to 5000 m\u003c\/span\u003e (16404 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance to Electrostatic Discharge:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e4 kV contact\u003c\/span\u003e, \u003cspan style=\"color: #3498db;\"\u003e8 kV air\u003c\/span\u003e (IEC 801-2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance to Electromagnetic Fields:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e9.1 V\/m (10 V\/m)\u003c\/span\u003e 80-2000 MHz (IEC 801-3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Schneider Electric \u003cstrong\u003e140HLI34000\u003c\/strong\u003e latch\/interrupt module\u003c\/li\u003e\n\u003cli\u003e1x installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Dimensions (Unit)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e4.500 cm\u003c\/span\u003e (1.77 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e16.500 cm\u003c\/span\u003e (6.50 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e31.500 cm\u003c\/span\u003e (12.40 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Weight:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e408 g\u003c\/span\u003e (14.392 oz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the part number for this latch\/interrupt module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number is \u003cstrong style=\"color: #c41e3a;\"\u003e140HLI34000\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many inputs does the \u003cstrong\u003e140HLI34000\u003c\/strong\u003e have and what is their response time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt features \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e16 fast isolated inputs\u003c\/span\u003e with response times of \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e130 µs Off-On\u003c\/span\u003e and \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e30 µs On-Off\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What isolation ratings does this module provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e500V AC isolation between channels\u003c\/span\u003e and \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e1780V AC isolation between channels and bus\u003c\/span\u003e (both for 60 seconds).\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51544980422788,"sku":"140HLI34000","price":332.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/140HLI34000.jpg?v=1771484708","url":"https:\/\/www.etowonauto.com\/kk\/products\/schneider-140hli34000-latch-interrupt-module","provider":"Etowon Auto","version":"1.0","type":"link"}