{"product_id":"schneider-140ddi84100-10-60v-dc-input-module","title":"Schneider 140DDI84100 10-60V DC Input Module","description":"\u003ch2\u003e\u003cstrong\u003eSchneider Electric 140DDI84100 Discrete Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e140DDI84100\u003c\/strong\u003e provides reliable discrete input processing. This Modicon Quantum module handles 16 industrial signals with precision.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e140DDI84100\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Modicon Quantum automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e DC discrete input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Points:\u003c\/strong\u003e 16 discrete inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrouping:\u003c\/strong\u003e 8 channels per group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Type:\u003c\/strong\u003e Positive (sink) input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 10...60 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Voltage:\u003c\/strong\u003e 75 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 200 mA from bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 1 W + (0.62 x active points)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Requirement:\u003c\/strong\u003e 1 input word\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInput Voltage Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12V Input:\u003c\/strong\u003e 5…10 mA DC, State 1: 9-12V, State 0: 0-1.8V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V Input:\u003c\/strong\u003e 6…30 mA DC, State 1: 11-24V, State 0: 0-5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48V Input:\u003c\/strong\u003e 2…15 mA DC, State 1: 34-48V, State 0: 0-10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e60V Input:\u003c\/strong\u003e 1…5 mA DC, State 1: 45-60V, State 0: 0-9V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePerformance Metrics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 4 ms (0→1 and 1→0)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e ≤ 100 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation (Group-Bus):\u003c\/strong\u003e 2500 Vrms DC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation (Group-Group):\u003c\/strong\u003e 700 Vrms DC for 1 minute\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0…60 °C (32…140 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40…85 °C (-40…185 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e ≤ 5000 m (16404 ft)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e UL 508, CSA C22.2 No 142\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e FM Class 1 Division 2, C-tick, CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e 4 kV contact, 8 kV air discharge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRF Immunity:\u003c\/strong\u003e 9.1 V\/m, 80-2000 MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.3 kg (0.7 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Format:\u003c\/strong\u003e Standard Quantum module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e 1 green bus LED, 1 red fault LED, 16 green input LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging Information\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Package:\u003c\/strong\u003e 1 piece per box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Dimensions:\u003c\/strong\u003e 31.21 x 16.64 x 4.64 cm (12.29 x 6.55 x 1.83 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e 0.44 kg (0.97 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulk Package:\u003c\/strong\u003e 7 pieces per carton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulk Dimensions:\u003c\/strong\u003e 40 x 30 x 30 cm (15.75 x 11.81 x 11.81 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulk Weight:\u003c\/strong\u003e 3.749 kg (8.265 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage ranges does this module support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e140DDI84100\u003c\/strong\u003e accepts 10-60V DC inputs. It automatically detects common industrial voltages like 12V, 24V, 48V, and 60V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many input points can I monitor with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module provides 16 discrete input points. These are organized into two groups of 8 channels for efficient wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module suitable for hazardous locations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it carries FM Class 1 Division 2 certification. The module operates safely in potentially explosive industrial environments.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51492579082372,"sku":"140DDI84100","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/140DDI84100-1.jpg?v=1769433340","url":"https:\/\/www.etowonauto.com\/kk\/products\/schneider-140ddi84100-10-60v-dc-input-module","provider":"Etowon Auto","version":"1.0","type":"link"}