{"product_id":"mtl5049-dual-channel-signal-isolator-mtl-instruments","title":"MTL5049 Dual Channel Signal Isolator - MTL Instruments","description":"\u003ch2\u003e\u003cstrong\u003eMTL5049 Dual Channel Signal Isolator\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL5049\u003c\/strong\u003e from MTL Instruments provides safe signal isolation for hazardous area applications. This dual-channel unit passes two 4-20mA signals from safe-area controllers to loads in explosive atmospheres. It delivers precise signal transfer with complete electrical isolation between areas.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eMTL Instruments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u003cstrong\u003eMTL5049\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDual Channel Signal Isolator\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eTwo independent channels\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e4 to 20mA\u003c\/span\u003e standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e0 to 24mA\u003c\/span\u003e capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e250µs\u003c\/span\u003e to 10% of final value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Location:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eZone 0, IIC, T4-T6\u003c\/span\u003e hazardous area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDivision Rating:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDivision 1, Group A\u003c\/span\u003e hazardous location\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eMTL5049\u003c\/strong\u003e maintains intrinsic safety standards\u003c\/li\u003e\n\u003cli\u003eIt provides safe signal transmission to explosive atmospheres\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e4 to 20mA\u003c\/span\u003e from controllers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e0 to 24mA\u003c\/span\u003e under\/over range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Drop:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;4V at 20mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 1 Input:\u003c\/strong\u003e Terminal 11 (Input –ve), Terminal 12 (Input +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 2 Input:\u003c\/strong\u003e Terminal 8 (Input –ve), Terminal 9 (Input +ve)\u003c\/li\u003e\n\u003cli\u003eLow input voltage drop minimizes impact on controller outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e550Ω maximum\u003c\/span\u003e per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e11V at 20mA\u003c\/span\u003e driving capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026gt;2MΩ\u003c\/span\u003e for minimal loading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 1 Output:\u003c\/strong\u003e Terminal 1 (Output –ve), Terminal 2 (Output +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 2 Output:\u003c\/strong\u003e Terminal 4 (Output –ve), Terminal 5 (Output +ve)\u003c\/li\u003e\n\u003cli\u003eEach channel independently drives hazardous area loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy \u0026amp; Speed\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransfer Accuracy:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eBetter than 20µA at 20°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Drift:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;1µA\/°C\u003c\/span\u003e for stable operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Settles within \u003cspan style=\"color: #2e75b6;\"\u003e250µs\u003c\/span\u003e to 10% of final value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Ripple:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;40µA peak-to-peak\u003c\/span\u003e ensures clean signals\u003c\/li\u003e\n\u003cli\u003eHigh speed and accuracy maintain process control integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e65mA at 24V\u003c\/span\u003e with both channels active\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e1.4W at 24V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Terminals:\u003c\/strong\u003e Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Green LED provides clear power status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 1:\u003c\/strong\u003e Input (Terminals 11-12), Output (Terminals 1-2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 2:\u003c\/strong\u003e Input (Terminals 8-9), Output (Terminals 4-5)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Terminals 13-14 for 20-35V DC input\u003c\/li\u003e\n\u003cli\u003eClear terminal labeling simplifies installation and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e28V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e300Ω\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e93mA\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eUm = 250V rms or DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eComplete isolation ensures safe area protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many signals can the MTL5049 handle?\u003c\/strong\u003e\u003cbr\u003eIt isolates and passes two independent 4-20mA signals simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum load capacity?\u003c\/strong\u003e\u003cbr\u003eEach output channel drives loads up to 550Ω with 11V at 20mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast does the unit respond to signal changes?\u003c\/strong\u003e\u003cbr\u003eIt settles within 250 microseconds to within 10% of final value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this suitable for Zone 0 hazardous areas?\u003c\/strong\u003e\u003cbr\u003eYes, it carries certification for Zone 0, IIC, T4-T6 areas and Division 1, Group A.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":51268247847044,"sku":"MTL5049","price":58.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/MTL5049.jpg?v=1762683472","url":"https:\/\/www.etowonauto.com\/kk\/products\/mtl5049-dual-channel-signal-isolator-mtl-instruments","provider":"Etowon Auto","version":"1.0","type":"link"}