{"product_id":"mtl5031-vibration-sensor-interface-mtl-instruments","title":"MTL5031 Vibration Sensor Interface - MTL Instruments","description":"\u003ch2\u003e\u003cstrong\u003eMTL5031 Vibration Sensor Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL5031\u003c\/strong\u003e from MTL Instruments safely repeats vibration signals from hazardous areas to monitoring systems. This single-channel interface works with 3-wire eddy-current probes and accelerometers located in explosive atmospheres. \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eMTL Instruments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u003cstrong\u003eMTL5031\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eVibration Sensor Interface\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eOne channel\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Sensors:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e3-wire eddy-current probes \u0026amp; accelerometers\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Bandwidth:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e-3dB at 43kHz typical\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Location:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eZone 0, IIC, T4-T6\u003c\/span\u003e hazardous area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDivision Rating:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDivision 1, Group A\u003c\/span\u003e hazardous location\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eMTL5031\u003c\/strong\u003e maintains intrinsic safety for vibration monitoring\u003c\/li\u003e\n\u003cli\u003eIt enables safe operation of sensors in explosive atmospheres\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e10kΩ ±2%\u003c\/span\u003e (Terminals 1 and 2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Supply:\u003c\/strong\u003e Terminals 3 and 1 for sensor power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e-20V to -0.5V\u003c\/span\u003e for \u0026lt;100mV DC error\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Terminals:\u003c\/strong\u003e Terminal 1 (Common), Terminal 2 (Signal)\u003c\/li\u003e\n\u003cli\u003eThe interface provides power for 3-wire vibration sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Impedance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;20Ω\u003c\/span\u003e (Terminals 11 and 12)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminals:\u003c\/strong\u003e Terminal 11 (Signal –ve), Terminal 12 (Signal 0V)\u003c\/li\u003e\n\u003cli\u003eLow output impedance ensures strong signal drive capability\u003c\/li\u003e\n\u003cli\u003eClean signal transmission to monitoring systems in safe areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy \u0026amp; Frequency Response\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Transfer Accuracy:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;±100mV at 20°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Transfer Accuracy:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e±1% (0Hz to 1kHz)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e-5% to +1% (1kHz to 10kHz)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Bandwidth:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e-3dB at 43kHz typical\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Coefficient:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e±50ppm\/°C (10 to 65°C)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhase Response \u0026amp; Timing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Response:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;14µs equivalent delay\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Shift:\u003c\/strong\u003e -1° at 200Hz, -3° at 600Hz, -5° at 1kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Frequency:\u003c\/strong\u003e -50° at 10kHz, -100° at 20kHz\u003c\/li\u003e\n\u003cli\u003eMinimal phase distortion preserves signal integrity for analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e80mA at 24V\u003c\/span\u003e with 22mA transducer load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u0026lt;1.7W\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Terminals:\u003c\/strong\u003e Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Green LED for power monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e Terminal 1 (Common), 2 (Signal), 3 (Transducer Power)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe Area Output:\u003c\/strong\u003e Terminal 11 (Signal –ve), 12 (Signal 0V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Terminal 13 (Supply –ve), 14 (Supply +ve)\u003c\/li\u003e\n\u003cli\u003eClear terminal identification ensures proper sensor connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals 3 to 1:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e26.6V, 94mA, 0.66W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals 2 to 1:\u003c\/strong\u003e Non-energy-storing apparatus specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Limits:\u003c\/strong\u003e ≤1.2V, ≤0.1A, ≤20µJ and ≤25mW\u003c\/li\u003e\n\u003cli\u003eComprehensive safety protection for hazardous area operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat sensors work with the MTL5031?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with 3-wire eddy-current probes and accelerometers for vibration monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the frequency response range?\u003c\/strong\u003e\u003cbr\u003eThe interface maintains ±1% accuracy from 0Hz to 1kHz with 43kHz bandwidth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this interface power the sensors?\u003c\/strong\u003e\u003cbr\u003eYes, it provides transducer supply voltage through terminals 3 and 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this suitable for Zone 0 vibration monitoring?\u003c\/strong\u003e\u003cbr\u003eYes, it carries full certification for Zone 0, IIC, T4-T6 hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":51268250599556,"sku":"MTL5031","price":58.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/MTL5031-2.jpg?v=1762684101","url":"https:\/\/www.etowonauto.com\/kk\/products\/mtl5031-vibration-sensor-interface-mtl-instruments","provider":"Etowon Auto","version":"1.0","type":"link"}