{"product_id":"ic695pbs301-ge-fanuc-profibus-slave-module-pacsystems","title":"IC695PBS301 | GE Fanuc Profibus Slave Module PACSystems","description":"\u003ch2\u003eGeneral Electric IC695PBS301 PACSystems RX3i Profibus Slave Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IC695PBS301\u003c\/strong\u003e is a Profibus DP Slave module for the PACSystems RX3i series. It provides slave communication over the Profibus DP network. \u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric (GE Fanuc \/ GE Intelligent Platforms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC695PBS301\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Profibus Slave Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog:\u003c\/strong\u003e IC695\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.45 kg (1.0 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Protocol: Profibus DP\u003c\/li\u003e\n\u003cli\u003ePort: 9-pin Sub-D connector\u003c\/li\u003e\n\u003cli\u003eInput Data per Slave: Up to 244 Bytes\u003c\/li\u003e\n\u003cli\u003eOutput Data per Slave: Up to 244 Bytes\u003c\/li\u003e\n\u003cli\u003eSupported Features: DP-V1 Read-Write and Alarm messages\u003c\/li\u003e\n\u003cli\u003eData Exchange: Automatic with master device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupported Baud Rates\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e9.6 kBit\/s\u003c\/li\u003e\n\u003cli\u003e19.2 kBit\/s\u003c\/li\u003e\n\u003cli\u003e93.75 kBit\/s\u003c\/li\u003e\n\u003cli\u003e187.5 kBit\/s\u003c\/li\u003e\n\u003cli\u003e500 kBit\/s\u003c\/li\u003e\n\u003cli\u003e1.5 MBit\/s\u003c\/li\u003e\n\u003cli\u003e3 MBit\/s\u003c\/li\u003e\n\u003cli\u003e6 MBit\/s\u003c\/li\u003e\n\u003cli\u003e12 MBit\/s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Consumption: 440 mA at 3.3 VDC\u003c\/li\u003e\n\u003cli\u003eNumber of Slots: 1 (single slot)\u003c\/li\u003e\n\u003cli\u003eBackplane Support: Universal backplane\u003c\/li\u003e\n\u003cli\u003eBackplane Compatibility: RX3i PCI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLED Indicators\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePROFIBUS OK (Green): Shows power presence and complete backplane reset\u003c\/li\u003e\n\u003cli\u003eNETWORK (Yellow\/Red Bicolor): Green shows telegrams transmitting, Red shows critical communication problems\u003c\/li\u003e\n\u003cli\u003eMOD STATUS (Bicolor): Displays module operating status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFirmware and Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFirmware Upgrades: Indirectly via host controller CPU using WinLoader software utility\u003c\/li\u003e\n\u003cli\u003eWinLoader: Provides updates to Profibus module software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHost Controller: PACSystem RX3i CPU with compatible firmware\u003c\/li\u003e\n\u003cli\u003eBackplane: Universal backplane required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between IC695PBM300 and IC695PBS301?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IC695PBM300 is a Profibus Master module. The \u003cstrong\u003eIC695PBS301\u003c\/strong\u003e is a Profibus Slave module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How much data can this slave module handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003eIC695PBS301\u003c\/strong\u003e supports up to 244 bytes of input data and 244 bytes of output data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the weight of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module weighs approximately 0.45 kg (1.0 lb) and fits a single RX3i backplane slot.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050857398404,"sku":"IC695PBS301","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695PBS301.jpg?v=1775135946","url":"https:\/\/www.etowonauto.com\/kk\/products\/ic695pbs301-ge-fanuc-profibus-slave-module-pacsystems","provider":"Etowon Auto","version":"1.0","type":"link"}