{"product_id":"honeywell-fx-usi-0002-universal-safety-interface","title":"Honeywell FX-USI-0002 Universal Safety Interface","description":"\u003ch2\u003eUniversal Safety Interface with 4 Communication Channels\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FX-USI-0002\u003c\/strong\u003e Universal Safety Interface enables Ethernet and serial communication with external devices. \u003c\/p\u003e\n\u003ch2\u003eCommunication \u0026amp; Safety Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #b22222;\"\u003eFour independent communication channels\u003c\/span\u003e for versatile connectivity options\u003c\/li\u003e\n\u003cli\u003eBuilt-in hardware firewall safeguards safety functions within Safety Manager\u003c\/li\u003e\n\u003cli\u003eMotorola 8270 communication processor powers efficient data exchange\u003c\/li\u003e\n\u003cli\u003eSupports EUCN protocol (\u003cstrong\u003eFX-USI-0002\u003c\/strong\u003e and \u003cstrong\u003eFE-USI-0002\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMemory Architecture\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlash memory:\u003c\/strong\u003e 8 Mbyte for system and application programs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal SRAM:\u003c\/strong\u003e 8 Mbyte with Error Detecting and Correcting logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShared RAM:\u003c\/strong\u003e 256 kilobyte for data exchange with Control Processor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEEPROM:\u003c\/strong\u003e Stores MAC addresses and hardware revision numbers\u003c\/li\u003e\n\u003cli\u003eUpdate flash content without removing the module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCommunication Interfaces\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTwo dual-speed fast Ethernet transceivers for high-speed network\u003c\/li\u003e\n\u003cli\u003eTwo general-purpose serial communication controller channels\u003c\/li\u003e\n\u003cli\u003eVersatile serial communication capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eFX-USI-0002\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e \u003cspan style=\"color: #b22222;\"\u003eCE, TUV, UL, CSA, FM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V supply voltage:\u003c\/strong\u003e 5V DC ±5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V supply current:\u003c\/strong\u003e 1.2A maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to +70°C (+23°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 10-95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 176 × 35.2 × 212 mm (H × W × D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.7 kg\u003c\/li\u003e\n\u003cli\u003eCompact form factor for Controller chassis installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility Note\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFX-USI-0002\u003c\/strong\u003e replaces \u003cstrong\u003eFC-USI-0001\u003c\/strong\u003e, \u003cstrong\u003eFC-USI-0002\u003c\/strong\u003e, and \u003cstrong\u003eFE-USI-0002\u003c\/strong\u003e from Safety Manager R140 and higher\u003c\/li\u003e\n\u003cli\u003eDrop-in replacement for existing installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation \u0026amp; Packaging\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePlugs directly into Controller chassis\u003c\/li\u003e\n\u003cli\u003eIncludes module with front-panel connectors\u003c\/li\u003e\n\u003cli\u003eReady for Ethernet and serial cable connection\u003c\/li\u003e\n\u003cli\u003eShipping: FedEx, UPS, DHL worldwide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between FX-USI-0002 and previous versions?\u003c\/strong\u003e \u003cbr\u003eA: \u003cstrong\u003eFX-USI-0002\u003c\/strong\u003e replaces \u003cstrong\u003eFC-USI-0001\u003c\/strong\u003e, \u003cstrong\u003eFC-USI-0002\u003c\/strong\u003e, and \u003cstrong\u003eFE-USI-0002\u003c\/strong\u003e from R140 onward. It offers enhanced memory and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this module work as a firewall?\u003c\/strong\u003e \u003cbr\u003eA: Yes. The \u003cstrong\u003eUSI-0002\u003c\/strong\u003e includes a hardware firewall that protects safety functions from unauthorized network access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What protocols does FX-USI-0002 support?\u003c\/strong\u003e \u003cbr\u003eA: It supports EUCN protocol. The module handles Ethernet and serial communication for external device connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573262647428,"sku":"FC-USI-0002","price":602.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-USI-0002-1.jpg?v=1772360407","url":"https:\/\/www.etowonauto.com\/kk\/products\/honeywell-fx-usi-0002-universal-safety-interface","provider":"Etowon Auto","version":"1.0","type":"link"}