{"product_id":"ge-multilin-ur6th-i-o-module-digital-input-output-ur-6th","title":"GE Multilin UR6TH I\/O Module | Digital Input Output UR 6TH","description":"\u003ch2\u003e\u003cstrong\u003eGE Multilin UR6TH Universal Relay I\/O Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe GE Multilin \u003cstrong\u003eUR6TH\u003c\/strong\u003e is a digital I\/O interface module for universal relay systems. It provides 8 contact inputs and 4 relay outputs to connect protection relays with field devices. This module operates in extreme temperatures from -40°C to 70°C.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e GE Multilin \u003cstrong\u003eUR6TH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital I\/O Interface Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e 8 contact inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e 24-250V DC\/AC (depending on relay)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Response:\u003c\/strong\u003e \u0026lt;10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Outputs:\u003c\/strong\u003e 4 Form-A (non-monitoring)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Rating:\u003c\/strong\u003e 30V DC\/1A or 250V AC\/5A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Speed:\u003c\/strong\u003e \u0026lt;4 ms activation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24V DC or 48V DC (module dependent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e ~10W max, 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 19-inch rack, 1U height, horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e Approx. 1.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 digital contact inputs for status monitoring\u003c\/li\u003e\n\u003cli\u003e4 Form-A relay outputs for control commands\u003c\/li\u003e\n\u003cli\u003eWide operating voltage range for inputs\u003c\/li\u003e\n\u003cli\u003eCompatible with GE Multilin T60, UR series relays\u003c\/li\u003e\n\u003cli\u003eRugged design for harsh electrical environments\u003c\/li\u003e\n\u003cli\u003eHot-swappable in supported systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for GE Multilin universal relay chassis\u003c\/li\u003e\n\u003cli\u003eMounts horizontally in 19-inch rack (1U space)\u003c\/li\u003e\n\u003cli\u003eIntegrates with power supply, CPU, and other I\/O modules\u003c\/li\u003e\n\u003cli\u003eSystem limit: Max 3 transducer I\/O modules per T60 relay\u003c\/li\u003e\n\u003cli\u003eCommunication: Supports one inter-relay comms link\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x UR6TH I\/O module unit\u003c\/li\u003e\n\u003cli\u003eApproximate shipping weight: 1.8 kg\u003c\/li\u003e\n\u003cli\u003eSecure protective packaging\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is this module used for?\u003c\/strong\u003e\u003cbr\u003eIt interfaces GE Multilin protection relays with field devices like circuit breaker aux contacts (inputs) and trip coils (outputs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan it handle AC and DC signals?\u003c\/strong\u003e\u003cbr\u003eYes, inputs support 24-250V DC or AC depending on the connected relay's configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Form-A output\" mean?\u003c\/strong\u003e\u003cbr\u003eForm-A is a single-pole, normally open (SPST-NO) relay contact.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050878468228,"sku":"UR-6TH","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/UR8AH.jpg?v=1768617353","url":"https:\/\/www.etowonauto.com\/kk\/products\/ge-multilin-ur6th-i-o-module-digital-input-output-ur-6th","provider":"Etowon Auto","version":"1.0","type":"link"}