{"product_id":"ge-fanuc-plc-connection-cable-ic693cbl319-24-conductor","title":"GE Fanuc PLC Connection Cable IC693CBL319 24-Conductor","description":"\u003ch2 style=\"color: #1976d2; font-weight: bold; font-size: 1.6em; margin-bottom: 15px;\"\u003e\n\u003cspan style=\"color: #1976d2; font-weight: bold;\"\u003eGE Fanuc IC693CBL319\u003c\/span\u003e Series 90-30 I\/O Interface Cable\u003c\/h2\u003e\n\u003cp style=\"font-size: 1em; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003eThe GE Fanuc IC693CBL319 is a high-performance, 3.0-foot (1.0-meter) I\/O interface cable specifically engineered for the Series 90-30 PLC platform. Designed as a Wye-type cable with an integrated shield, it features a 24-pin female connector on one end and a 25-pin D-type terminal block connector on the other. Built with premium 28 AWG copper conductors, a 95% braided shield for exceptional noise suppression, and a flexible, flame-retardant PVC jacket, this interface cable ensures secure and noise-free signal routing in challenging industrial environments.\u003c\/p\u003e\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 0.95em;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333; width: 40%;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eGE Fanuc (Emerson Industrial Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #d32f2f; font-weight: bold;\"\u003eIC693CBL319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003ePLC Series Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eSeries 90-30 PLC Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e3.0 Feet (1.0 Meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eConnector 1: 24-Pin Female | Connector 2: 25-Pin D-Type Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eCable \u0026amp; Wiring Architecture\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eWye Type with integrated shield, 24 total conductors (A1-A12, B1-B12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eConductor Specifications\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e28 AWG Copper Wire (0.32 mm wire diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eShielding Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e95% Braided Shield for electromagnetic interference (EMI) reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eElectrical Ratings\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eOperating Voltage: 300 V AC\/DC | Current Rating: 5 A per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003ePhysical Outer Jacket\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eFlexible PVC Housing | UL VW-1 Flame Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eBending \u0026amp; Weight Profile\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eMinimum Bend Radius: 30 mm | Average Weight: 2.0 lb (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eThermal Operating Range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eOperating: -20°C to +60°C | Storage: -40°C to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eQuick Installation Guide\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003eEnsure that the power supply to the Series 90-30 PLC rack is completely turned off before installing or removing the I\/O interface cable.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003eAlign the 24-pin female connector of the IC693CBL319 cable with the corresponding male port on the PLC module, pressing firmly until seated, and secure any integrated locking screws.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003eRoute the 1.0-meter flexible PVC cable jacket through your enclosure wire ducts, keeping the routing pathway well within the 30 mm minimum bending radius to prevent strain on the internal 28 AWG copper conductors.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003eConnect the 25-pin D-type terminal block connector to the terminal block interface, ensuring the integrated 95% braided shield is properly grounded at the designated chassis grounding point to mitigate electrical noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\u003cstrong\u003eQ1: What is the primary function of the \"Wye\" type cable design in the IC693CBL319 assembly?\u003c\/strong\u003e\u003cbr\u003eA1: The Wye-type configuration splits the internal 24-conductor physical wiring harness into structured signal groups (A1–A12 and B1–B12). This arrangement cleanly distributes logical power and signal paths from a high-density 24-pin PLC module port over to a standardized 25-pin D-sub terminal block interface, simplifying diagnostic mapping and field wiring tasks.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\u003cstrong\u003eQ2: Why is the 95% braided shielding coverage crucial for industrial PLC applications?\u003c\/strong\u003e\u003cbr\u003eA2: Industrial control cabinets are high-noise environments surrounded by electromagnetic interference (EMI) from motor drives, contactors, and high-voltage conduits. The 95% copper braided shield acts as a Faraday cage, diverting high-frequency noise currents directly to ground and keeping sensitive low-voltage I\/O signals clear of distortion.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\u003cstrong\u003eQ3: Can the IC693CBL319 interface cable handle 120 V AC control circuits?\u003c\/strong\u003e\u003cbr\u003eA3: Yes. The cable is electrically rated for an operating voltage of up to 300 V AC\/DC. However, you must ensure that the continuous current passing through any single 28 AWG conductor within the 24-wire bunch does not exceed its maximum thermal rating of 5 A, keeping the installation safe and well within operating specifications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050811818116,"sku":"IC693CBL319","price":174.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693CBL319.jpg?v=1784120176","url":"https:\/\/www.etowonauto.com\/kk\/products\/ge-fanuc-plc-connection-cable-ic693cbl319-24-conductor","provider":"Etowon Auto","version":"1.0","type":"link"}