{"product_id":"fc-usi-0001-honeywell-safety-system-interface","title":"FC-USI-0001 | Honeywell Safety System Interface","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell FC-USI-0001 Universal Safety Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eFC-USI-0001\u003c\/strong\u003e is a Universal Safety Interface module. It connects \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003esafety field devices to control systems\u003c\/strong\u003e\u003c\/span\u003e with high integrity.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eBasic Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eFC-USI-0001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Universal Safety Interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Industrial safety systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e FC Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 8 configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types:\u003c\/strong\u003e Digital or analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Input:\u003c\/strong\u003e 24V DC sink\/source\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input:\u003c\/strong\u003e 4-20 mA or 0-10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Accuracy:\u003c\/strong\u003e ±0.1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;20 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOutput Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 4 configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Types:\u003c\/strong\u003e Digital or analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e 24V DC, 0.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e 4-20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Short circuit protected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSettling Time:\u003c\/strong\u003e \u0026lt;5 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e SIL 2 capable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Coverage:\u003c\/strong\u003e \u0026gt;90%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Detection:\u003c\/strong\u003e Continuous self-test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe State:\u003c\/strong\u003e Configurable per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Monitoring:\u003c\/strong\u003e Open\/short detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross Channel:\u003c\/strong\u003e Isolation between groups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24V DC ±20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 4W typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1500V field to logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Isolation:\u003c\/strong\u003e 500V group to group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e Industrial environment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -20 to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temp:\u003c\/strong\u003e -40 to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 2g, 10-150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e 10g, 11ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 130 x 95 x 55 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.4 kg (0.88 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail TS35\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors:\u003c\/strong\u003e Spring clamp terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e 24-14 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Green LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e Green\/Red LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault:\u003c\/strong\u003e Red LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Status:\u003c\/strong\u003e 12 green LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic:\u003c\/strong\u003e Via bus communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eFC-USI-0001\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003eTerminal connectors (pre-installed)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting clip\u003c\/li\u003e\n\u003cli\u003eConfiguration guide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePower off before installation\u003c\/li\u003e\n\u003cli\u003eMount on TS35 DIN rail\u003c\/li\u003e\n\u003cli\u003eConnect 24V DC supply\u003c\/li\u003e\n\u003cli\u003eConfigure channels via software\u003c\/li\u003e\n\u003cli\u003eWire field devices accordingly\u003c\/li\u003e\n\u003cli\u003eVerify LED status after power-up\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat devices connect to this module?\u003c\/strong\u003e\u003cbr\u003eSafety sensors, E-stops, light curtains, and safety relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens on fault?\u003c\/strong\u003e\u003cbr\u003eOutputs go to safe state, fault LED lights.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it SIL rated?\u003c\/strong\u003e\u003cbr\u003eYes, SIL 2 capable for safety applications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51535856107652,"sku":"FC-USI-0001","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-USI-0001-2.jpg?v=1771058526","url":"https:\/\/www.etowonauto.com\/kk\/products\/fc-usi-0001-honeywell-safety-system-interface","provider":"Etowon Auto","version":"1.0","type":"link"}