{"product_id":"combination-i-o-ge-fanuc-ic693mar590-8-input-8-output","title":"Combination I\/O GE Fanuc IC693MAR590 8-Input 8-Output","description":"\u003ch2 style=\"color: #1A237E; font-size: 22px; font-weight: bold; margin-bottom: 12px;\"\u003eGE Fanuc IC693MAR590 AC Input \/ Relay Output Combination Module\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  The \u003cstrong style=\"color: #0D47A1;\"\u003e\u003cspan style=\"color: #0D47A1;\"\u003eGE Fanuc IC693MAR590\u003c\/span\u003e\u003c\/strong\u003e is a high-reliability combination I\/O module designed for the Series 90-30 Programmable Logic Controller (PLC) architecture. Featuring 8 120V AC input channels and 8 normally-open relay output channels within a single slot, this unit optimizes rack space while delivering control capabilities for automated processing systems. Weighing just 0.3 kg (0.75 lbs), it installs easily into any standard 5-slot or 10-slot Series 90-30 baseplate.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eKey Performance Advantages\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  Engineered for industrial environments, the IC693MAR590 provides enhanced durability and long service life. Its 8 input circuits are arranged in a single group with an ON-state voltage threshold of 74 to 132 V AC and a 6 mA minimum operating current. On the output side, 8 isolated relay contacts handle maximum load currents up to 2 Amps per point with a 5 Amp inrush capacity, making it suitable for controlling motor starters, solenoids, indicators, and control valves. With a relay response time of 15 milliseconds, it delivers fast, reliable switching for real-time automation feedback loops.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; color: #333333; margin-bottom: 15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0; width: 40%;\"\u003eManufacturer \u0026amp; Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eGE Fanuc \/ Series 90-30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eIC693MAR590\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eChannel Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e8 Inputs (1 group) \/ 8 Relay Outputs (2 groups of 4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eON-State Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e74 to 132 Volts AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eOFF-State Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e0 to 20 Volts AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eON-State Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e6 milliAmps (minimum)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eMax Load Capacity \u0026amp; Inrush\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e2 Amps per output \/ 5 Amps maximum inrush\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eOutput Response Time\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e15 milliseconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eModule Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e0.3 kg (0.75 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eInstallation \u0026amp; Operation Notes\u003c\/h3\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Compatibility:\u003c\/strong\u003e Installs into any available I\/O slot of a Series 90-30 5-slot or 10-slot baseplate.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Guidelines:\u003c\/strong\u003e Utilize the red-coded door card to log circuit wiring and signal tags for quick identification during maintenance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Protection:\u003c\/strong\u003e Ensure field loads do not exceed the 2A continuous rating per channel or 5A peak inrush. Suppress inductive load spikes across relay contacts where necessary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ1: What type of devices can be driven by the relay outputs on the IC693MAR590?\u003c\/strong\u003e\u003cbr\u003e\n  A1: The module can drive AC or DC loads including solenoids, indicator lamps, contactors, and small motor starters up to 2 Amps per channel.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ2: What is the ON\/OFF voltage range for the AC inputs?\u003c\/strong\u003e\u003cbr\u003e\n  A2: Inputs register as ON between 74 and 132 V AC and OFF between 0 and 20 V AC.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ3: How fast does the relay output respond to PLC state changes?\u003c\/strong\u003e\u003cbr\u003e\n  A3: The relay output features a fast response time of 15 milliseconds.\n\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050827939972,"sku":"IC693MAR590","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693MAR590-2.jpg?v=1785048501","url":"https:\/\/www.etowonauto.com\/kk\/products\/combination-i-o-ge-fanuc-ic693mar590-8-input-8-output","provider":"Etowon Auto","version":"1.0","type":"link"}