{"product_id":"bently-nevada-330851-02-000-080-50-00-cn-25mm-probe","title":"Bently Nevada 330851-02-000-080-50-00-CN 25mm Probe","description":"\u003ch2\u003eBently Nevada 330851-02-000-080-50-00-CN 25mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eBently Nevada 330851-02-000-080-50-00-CN\u003c\/strong\u003e | 3300 XL 25mm Proximity Probe with M30x2 threading and 80mm stainless steel case. Provides 0.787 V\/mm (20 mV\/mil) output over a 12.7 mm (500 mils) linear range [citation:2]. Engineered for differential expansion, shaft position, and vibration monitoring on steam turbines, compressors, and large rotating machinery [citation:10]. CN suffix denotes country-specific certifications.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e12.7 mm (500 mils) linear measurement range. 0.787 V\/mm (20 mV\/mil) scale factor. M30x2 industrial threading (Option 02). 80mm AISI 304 stainless steel case (Option 080). 5.0m (16.4 ft) FluidLoc cable without armor (Option 50-00). PEEK probe tip material [citation:2]. Recommended installation torque 68 N·m [citation:7]. Operating temperature -35°C to +200°C [citation:8]. Weight approx. 280g (9.9 oz) for 80mm case with 5m cable. Country-specific CN certification.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330851-02-000-080-50-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProbe Case Type (Option 02)\u003c\/td\u003e\n\u003ctd\u003eM30x2 thread\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eUnthreaded Length (Option 000)\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOverall Case Length (Option 080)\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTotal Length (Option 50)\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eArmor Option (Option 00)\u003c\/td\u003e\n\u003ctd\u003eNo armor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAgency Approval (Option CN)\u003c\/td\u003e\n\u003ctd\u003eCountry-specific certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (500 mils) [citation:2]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) [citation:2]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ω [citation:2]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProbe DC Resistance\u003c\/td\u003e\n\u003ctd\u003e7.5Ω ±0.8Ω at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e61 mm (2.4 in) diameter [citation:2]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePEEK (Polyetheretherketone) [citation:2]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel (SST) [citation:2]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75Ω triaxial PFA FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecommended Torque\u003c\/td\u003e\n\u003ctd\u003e68 N·m (50 ft·lb) [citation:7]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMaximum Torque\u003c\/td\u003e\n\u003ctd\u003e163 N·m (120 ft·lb) [citation:7]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35°C to +200°C (-31°F to +392°F) [citation:8]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-term Temperature\u003c\/td\u003e\n\u003ctd\u003e+250°C (482°F) max for \u0026lt;24 hours [citation:7]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing (with connector protection) [citation:8]\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight (80mm case, 5m cable)\u003c\/td\u003e\n\u003ctd\u003eApprox. 280g (9.9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Code Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330851-02-000-080-50-00-CN\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e330851\u003c\/strong\u003e – 3300 XL 25mm Proximity Probe.\u003cbr\u003e\u003cstrong\u003e02\u003c\/strong\u003e – Probe Case Type: M30x2 thread.\u003cbr\u003e\u003cstrong\u003e000\u003c\/strong\u003e – Unthreaded Length: 0 mm.\u003cbr\u003e\u003cstrong\u003e080\u003c\/strong\u003e – Overall Case Length: 80 mm.\u003cbr\u003e\u003cstrong\u003e50\u003c\/strong\u003e – Total Length: 5.0 m (16.4 ft).\u003cbr\u003e\u003cstrong\u003e00\u003c\/strong\u003e – Armor Option: No armor.\u003cbr\u003e\u003cstrong\u003eCN\u003c\/strong\u003e – Country-specific certifications.\u003c\/p\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMount probe using M30x2 threading. Apply recommended torque of 68 N·m (50 ft·lb), not to exceed 163 N·m (120 ft·lb) [citation:7]. Ensure minimum target size of 61 mm (2.4 in) diameter [citation:2]. Maintain operating temperature within -35°C to +200°C range [citation:8]. For differential expansion applications, mount probes on same collar or complementary ramps [citation:10]. Use Proximitor Sensor calibrated to AISI 4140 steel target [citation:4].\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e12.7 mm linear range provides extensive measurement capability for differential expansion monitoring. PEEK tip and AISI 304 stainless steel construction withstand harsh turbine environments [citation:2]. FluidLoc cable prevents oil leakage through cable interior. M30x2 threading supports heavy industrial mounting. Direct replacement for 7200 25mm and 35mm DE integral systems without monitor recalibration [citation:2]. CN certification enables installation in country-specific hazardous areas [citation:8].\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the linear measurement range of the 25mm probe?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 12.7 mm (500 mils) from 0.787 V\/mm (20 mV\/mil) output [citation:2].\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the recommended installation torque?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 68 N·m (50 ft·lb) recommended, 163 N·m (120 ft·lb) maximum [citation:7].\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Can this probe replace older 7200 series transducers?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Yes, the 3300 XL 25mm probe directly replaces standard 7200 25mm and 35mm DE integral systems without requiring monitor configuration changes [citation:2].\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050757161092,"sku":"330851-02-000-080-50-00-CN","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330851-02-000-080-50-00-CN.jpg?v=1787837290","url":"https:\/\/www.etowonauto.com\/kk\/products\/bently-nevada-330851-02-000-080-50-00-cn-25mm-probe","provider":"Etowon Auto","version":"1.0","type":"link"}