{"product_id":"allen-bradley-1766-mm1-micrologix-1400-memory-module","title":"Allen-Bradley 1766-MM1 MicroLogix 1400 Memory Module","description":"\u003ch2\u003eAllen-Bradley 1766-MM1 MicroLogix 1400 Memory Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eAllen-Bradley 1766-MM1\u003c\/strong\u003e | Memory module for MicroLogix 1400 controllers, providing 384 KB of additional storage for user programs and data. Protects against accidental deletion or corruption caused by voltage surges, improper operation, and human error. Supports program transfer between controllers, auto-recovery after fault, and write protection. Weight: approximately 20 g (0.7 oz).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1766-MM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMemory Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e384 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesigned For\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Controllers\u003c\/td\u003e\n\u003ctd\u003e1766-L32AWA, 1766-L32AWAA, 1766-L32BWA, 1766-L32BWAA, 1766-L32BXB, 1766-L32BXBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMemory Module slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Loading\u003c\/td\u003e\n\u003ctd\u003eYes (S:1\/11 \"Load Memory Module Always\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Bits\u003c\/td\u003e\n\u003ctd\u003eS:1\/10, S:1\/11, S:1\/12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 20 g (0.7 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAllowable Functions\u003c\/h3\u003e\n\u003cp\u003eStore user programs and data as backup. Transport programs for use with other controllers. Special safety\/security features for press control and other critical applications. Auto-recovery through a power cycle after controller fault. Program comparison. Data file and memory module write protection.\u003c\/p\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInsert the 1766-MM1 directly into the MicroLogix 1400 memory module slot. The controller ships with the memory module port and cover in place. The module can be removed or inserted under power; it is recognized after a power cycle. Configure automatic loading via the controller screen following system prompts, or use bit S:1\/11 to command the controller to load from the memory module. The memory module provides separately allocated storage and does not increase the controller's integrated memory.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003ePrevents accidental deletion or corruption of controller data caused by voltage surges, improper operation, or human error. Reduces unplanned shutdowns and increases process or machine availability. Supports program transfer between controllers for faster commissioning and replication. Auto-recovery after fault restores operation without manual reprogramming. Write protection safeguards critical programs and data. Removal and insertion under power simplifies maintenance and updates.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How much additional memory does this module provide?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 384 KB of user memory for programs and data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Which controllers are compatible?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 1766-L32AWA, 1766-L32AWAA, 1766-L32BWA, 1766-L32BWAA, 1766-L32BXB, and 1766-L32BXBA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Can the module be inserted or removed while the controller is running?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Yes, but the memory module is recognized only after a power cycle of the controller.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67932837838980,"sku":"1766-MM1","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1766-MM1-1.jpg?v=1795268752","url":"https:\/\/www.etowonauto.com\/kk\/products\/allen-bradley-1766-mm1-micrologix-1400-memory-module","provider":"Etowon Auto","version":"1.0","type":"link"}