{"product_id":"new-abb-07-do-90-s-gjr5250800r202-24v-dc-0-5a-transistor-output","title":"New ABB 07 DO 90-S GJR5250800R202 | 24V DC 0.5A Transistor Output","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e07 DO 90-S (GJR5250800R202)\u003c\/strong\u003e is a safety-critical \u003cstrong\u003eBinary Output Module\u003c\/strong\u003e manufactured by ABB as part of the \u003cstrong\u003eAdvant Controller 31 Safety System (AC31-S)\u003c\/strong\u003e. Engineered for fail-safe automation, this module features 8 electrically isolated channels operating at 24V DC nominal voltage. Delivering up to 0.5A load current per channel and a maximum total module current of 4A, it provides dependable control for safety actuators, contactors, and solenoids. The module incorporates electronic short-circuit protection, inductive interrupt voltage limiting via integrated clamping diodes, and active 0-signal voltage monitoring. Housed in a durable industrial enclosure measuring 120 x 140 x 85 mm with a physical hardware net weight of \u003cstrong\u003e400 g (0.88 lbs)\u003c\/strong\u003e, the 07 DO 90-S guarantees high operational safety across critical process control applications.\u003c\/p\u003e\n\u003cp\u003eAs illustrated in the product image, the unit features a sturdy DIN-rail mount chassis with accessible terminal blocks, diagnostic status LEDs, and clear pinout schematics on the front cover.\u003c\/p\u003e\n\n\u003ch3\u003eCore Technical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFail-Safe 0-Signal Level Monitoring:\u003c\/strong\u003e Continuously monitors off-state voltage levels; if a channel exceeds 8V while in state 0, the module automatically shuts down and trips a safety fault.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Inductive Load Limiting:\u003c\/strong\u003e Features built-in freewheeling diodes to suppress inductive kickback voltage spikes up to a 0.5 Hz switching frequency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Level Electrical Isolation:\u003c\/strong\u003e Provides 800V DC isolation to the internal system bus and 500V DC isolation to the field output circuits for superior noise immunity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Cable Distance Support:\u003c\/strong\u003e Supports long-distance field wiring runs up to 1000 meters with shielded cabling or 600 meters with unshielded cabling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter Attribute\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eFactory Specification Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOrder \/ Catalog Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e07 DO 90-S (GJR5250800R202)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Series \/ System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAdvant Controller 31 Safety System (AC31-S)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e8 Electrically Isolated Binary Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eRated Process Voltage (UP \/ L+)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e24V DC ±5% Ripple (Operating Range: 20.4V to 28.8V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.5A per Channel | 4A Maximum Total Module Current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003e0-Signal Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.3 mA Maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum Lamp Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e5 W Maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSignal Delay (0 → 1 \/ 1 → 0)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e8 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Voltage Level\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0-Signal: 0 to 3V DC | 1-Signal: \u0026gt; UP - 2.5V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eShort-Circuit \u0026amp; Overload Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eElectronic Short-Circuit Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eIsolation Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e800V DC (Bus to Field) \/ 500V DC (Output Group)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e15 W Maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eField Wiring Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1000m Maximum (Shielded) \/ 600m Maximum (Unshielded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePhysical Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e120 mm x 140 mm x 85 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePhysical Hardware Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e400 g (0.88 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCE Safety Certified (S-CE)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCondition \/ Warranty\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eNew \u0026amp; Original in Factory Box | 12-Month Factory Warranty\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Field Maintenance Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the 07 DO 90-S onto standard DIN rail. Connect 24V DC process voltage (UP) and supply voltage (L+) per VDE551 standards. Wire field outputs using conductors up to 2.5 mm² and torque screws to 0.5 Nm max. Ensure supply voltage ramps to 19V within 40ms of power-up.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the channel output capacity?\u003c\/strong\u003e\u003cbr\u003e\nA: Provides 8 channels rated at 0.5A per channel with a 4A total module limit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How does the short-circuit protection work?\u003c\/strong\u003e\u003cbr\u003e\nA: Features electronic short-circuit protection and shuts down if 0-signal voltage exceeds 8V.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What are the isolation and weight specs?\u003c\/strong\u003e\u003cbr\u003e\nA: 800V DC bus isolation, 500V DC output isolation, and a net weight of 400g.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":67648061669508,"sku":"GJR5250800R202","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/GJR5253100R3260.jpg?v=1792852705","url":"https:\/\/www.etowonauto.com\/it\/products\/new-abb-07-do-90-s-gjr5250800r202-24v-dc-0-5a-transistor-output","provider":"Etowon Auto","version":"1.0","type":"link"}