{"product_id":"ic670mdl642-ge-fanuc-field-control-positive-negative-logic","title":"IC670MDL642 GE Fanuc Controllo di Campo Logica Positiva e Negativa","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eModulo di ingresso logico 125VDC GE Fanuc IC670MDL642\u003c\/h2\u003e\n\n\u003ch3\u003ePanoramica prodotto\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color:#2c6e9e;\"\u003eIC670MDL642\u003c\/strong\u003e è un modulo di ingresso controllo di campo a 16 punti di GE Fanuc. Funziona a 125 Volt DC con logica positiva o negativa selezionabile. Supporta intervallo di tensione di ingresso da 0 a 150 Volt DC. Peso modulo 0,3 kg.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eParametro\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eValore\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMarca\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSerie\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eControllo di campo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eNumero di parte\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eIC670MDL642\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTensione nominale\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e125 Volt DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eIntervallo di tensione di ingresso\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0 a 150 Volt DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eNumero di ingressi\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCorrente di ingresso utente\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e2,5 mA per punto a 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTensione di isolamento\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e250 VAC continuo \/ 1500 VAC per 1 minuto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eImpedenza di ingresso\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e40kΩ minimo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTensione in stato acceso (logica positiva)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e+79 a +150 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTensione in stato acceso (logica negativa)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e-79 a -150 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTensione in stato spento (logica positiva)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0 a +30 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTensione in stato spento (logica negativa)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0 a -30 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCorrente in stato acceso\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0,3 a 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCorrente in stato spento\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0 a 0,5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTempo di risposta accensione\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e6 ms tipico \/ 10 ms massimo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTempo di risposta spegnimento\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e6 ms tipico \/ 20 ms massimo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePeso\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0,3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCaratteristiche principali\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 punti di ingresso con selezione logica positiva o negativa\u003c\/li\u003e\n\u003cli\u003eTensione nominale 125 VDC con intervallo da 0 a 150 VDC\u003c\/li\u003e\n\u003cli\u003eConsumo di corrente 2,5 mA per punto a tensione nominale\u003c\/li\u003e\n\u003cli\u003eIsolamento continuo 250 VAC, 1500 VAC per 1 minuto\u003c\/li\u003e\n\u003cli\u003eImpedenza di ingresso minima 40kΩ\u003c\/li\u003e\n\u003cli\u003eTempo di risposta rapido, tipico 6 ms accensione\/spegnimento\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eNote di installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelezionare la fonte di alimentazione logica esterna per 16 ingressi\u003c\/li\u003e\n\u003cli\u003eLa logica positiva indirizza corrente al bus negativo comune\u003c\/li\u003e\n\u003cli\u003eLa logica negativa riceve corrente dal bus positivo comune\u003c\/li\u003e\n\u003cli\u003eUsare il morsetto assegnato per le connessioni I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDomande frequenti\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Qual è la tensione nominale di IC670MDL642?\u003c\/strong\u003e\u003cbr\u003eA1: La tensione nominale è 125 Volt DC con intervallo operativo da 0 a 150 Volt DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Posso usare sia logica positiva che negativa sullo stesso modulo?\u003c\/strong\u003e\u003cbr\u003eA2: Sì. Il modulo supporta logica positiva o negativa selezionabile in base alle esigenze dell'applicazione.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Qual è il consumo di corrente per punto di ingresso?\u003c\/strong\u003e\u003cbr\u003eA3: 2,5 milliampere per punto a 125 Volt DC tensione nominale.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52140668092548,"sku":"IC670MDL642","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC670MDL642.jpg?v=1781017030","url":"https:\/\/www.etowonauto.com\/it\/products\/ic670mdl642-ge-fanuc-field-control-positive-negative-logic","provider":"Etowon Auto","version":"1.0","type":"link"}