{"product_id":"ge-is215acleh1b-acle-module-mark-vi-ex2100-control","title":"GE IS215ACLEH1B ACLE Module Mark VI EX2100 Control","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eGE Energy IS215ACLEH1B\u003c\/strong\u003e (Functional Acronym: \u003cstrong\u003eACLE\u003c\/strong\u003e) is a high-performance Application Control Layer Module designed for General Electric's Mark VI Speedtronic Gas Turbine Control Systems and EX2100 \/ EX2100e Excitation Control Systems. Engineered for critical industrial control applications, this microprocessor-based controller manages real-time turbine control logic, subsystem coordination, complex communication protocols, and system diagnostics.\u003c\/p\u003e\n\n\u003cp\u003eFeaturing an \"IS215\" domestic special modular assembly prefix, the \u003cstrong style=\"color: #0056b3;\"\u003eIS215ACLEH1B\u003c\/strong\u003e is built with a dual-slot metal faceplate tailored for standard GE VME rack structures and control cabinets. Operating with a 125 V DC input voltage and 24 V DC output, it incorporates a high-speed PCI controller, 128 KB L2 cache, 10BaseT RJ45 Ethernet communication, non-volatile flash memory, and an array of front-panel LED status indicators. Weighing approximately \u003cstrong\u003e0.57 kg (1.25 lbs)\u003c\/strong\u003e, this Grade B functional revision module delivers robust online application loading and real-time control block processing across demanding energy environments.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Microprocessor \u0026amp; PCI Controller Architecture:\u003c\/strong\u003e Equipped with an onboard CPU, PCI controller, and 128 KB Level 2 cache to optimize data transfers and high-speed input\/output processing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Network \u0026amp; Bus Connectivity:\u003c\/strong\u003e Features 10BaseT RJ45 Ethernet (IRQ 5 initialization via BIOS) for seamless communication over ISBus networks, SCADA systems, and central control hubs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Software \u0026amp; Logic Capabilities:\u003c\/strong\u003e Supports online application configuration loading, non-volatile flash memory storage, control block execution, and real-time forcing of I\/O points and internal booleans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVME Rack \u0026amp; Dual-Slot Integration:\u003c\/strong\u003e Engineered with a specialized installation faceplate that occupies two half-slots in standard EX2100 exciter board racks or Innovation Series drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGeneral Electric \/ GE Energy\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eFull Catalog Part Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIS215ACLEH1B\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMark VI Series \/ EX2100 \u0026amp; EX2100e Excitation System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eFunctional Acronym\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eACLE (Application Control Layer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eProduct Description\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eApplication Control Layer Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eInput \/ Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eInput: 125 V DC | Output: 24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCache Architecture\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eLevel 2, 128 KB (Controlled via PCI Controller)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eEthernet Port Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e10BaseT RJ45 Connector (Front Panel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMounting \u0026amp; Rack Form Factor\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eVME Rack Structure \/ Occupies 2 Half-Slots (Faceplate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBoard Dimensions\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e23.495 cm (H) x 10.795 cm (W)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eFunctional Revision\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1 B (Singular B-grade functional revision)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCountry of Manufacture\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eUnited States (USA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eEstimated Shipping Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eApprox. 0.57 kg (1.25 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Handling Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection \u0026amp; Static Safety:\u003c\/strong\u003e Always handle the ACLE board using a grounded wrist strap and static-safe equipment to avoid damaging onboard microprocessors and flash memory ICs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVME Rack Slot Insertion:\u003c\/strong\u003e Align the metal faceplate guide rails carefully into the two half-slots of the EX2100 exciter rack or Innovation drive cabinet before securing the faceplate retaining screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEthernet \u0026amp; Cable Connection:\u003c\/strong\u003e Connect standard RJ45 Ethernet cabling directly to the front-panel 10BaseT port, ensuring correct pin alignment and cable strain relief within the cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the GE IS215ACLEH1B module in turbine control systems?\u003c\/strong\u003e\u003cbr\u003e\nA1: It executes control logic, manages communication networks, enforces safety protocols, and coordinates subsystems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How does the IS215ACLEH1B module mount within the control cabinet?\u003c\/strong\u003e\u003cbr\u003e\nA2: It uses a metal installation faceplate designed to occupy two half-slots in standard EX2100 VME racks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What Ethernet communication interface is featured on the front panel of the IS215ACLEH1B board?\u003c\/strong\u003e\u003cbr\u003e\nA3: It features a 10BaseT RJ45 jack initialized by BIOS, managed via an onboard PCI controller.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52662555410564,"sku":"IS215ACLEH1B","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IS215ACLEH1B-5.jpg?v=1787380617","url":"https:\/\/www.etowonauto.com\/it\/products\/ge-is215acleh1b-acle-module-mark-vi-ex2100-control","provider":"Etowon Auto","version":"1.0","type":"link"}